Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

[802SEC] Responses to IEEE 802.1 comments on IEEE 802.3cx PAR and CSD (resend with corrected subject line)



Resend of email with 802.11 corrected to 802.1 in the subject line.

-----

Hi Glenn,

Thank you very much for the IEEE 802.1 comments, please see responses below.

Best regards,
  David

-----

IEEE P802.3cx Item 5.2.b: The suggestion to change '... in support of ITU-T Recommendation G.8273.2 'Class C' and 'Class D' system time error performance requirements."' To read '... with the target being ITU-T Recommendation G.8273.2 'Class C' and 'Class D' system time error performance requirements."' was not made since the ITU specification are system level specifications with IEEE 802.3 PHY layer being a small portion of the overall timing budget for these specifications.

IEEE P802.3cx Item 8.1: The suggested addition of ITU-T G.8275.1 was made.

IEEE P802.3cx CSD Broad Market Potential: The text 'as they move to higher-rate interfaces' was deleted from the end to the sentence in the second item as suggested.

IEEE P802.3cx CSD Compatibility: The typo was corrected.

An updated draft PAR and draft CSD are available at <https://mentor.ieee.org/802-ec/dcn/19/ec-19-0160-01-00EC-ieee-p802-3cx-draft-par-response.pdf> and <https://mentor.ieee.org/802-ec/dcn/19/ec-19-0161-01-00EC-ieee-p802-3cx-draft-csd-response.pdf> respectively with the above changes marked in strikeout and underscore.

-----

From: ***** IEEE 802 Executive Committee List ***** [mailto:STDS-802-SEC@ieee.org] On Behalf Of Glenn Parsons
Sent: 12 November 2019 22:25
To: STDS-802-SEC@LISTSERV.IEEE.ORG
Subject: [802SEC] 802.1 PAR comments on P802.3cx

Colleagues,

802.1 has comments on the P802.3cx PAR (and no comments on the others)

http://www.ieee802.org/1/files/public/docs2019/admin-PAR-comments-802-3cx-1119-v01.pdf

Cheers,
Glenn.

--
Glenn Parsons
Chair, IEEE 802.1 WG
glenn.parsons@ericsson.com
+1-613-963-8141

________________________________________
To unsubscribe from the STDS-802-SEC list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-SEC&A=1 

----------
This email is sent from the 802 Executive Committee email reflector.  This list is maintained by Listserv.