-- ********************************************************************** -- * IEEE 802.11 MIB -- ********************************************************************** IEEE802dot11-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Counter32, Counter64, Unsigned32, TimeTicks, Gauge32 FROM SNMPv2-SMI DisplayString , MacAddress, RowStatus, TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF ifIndex, InterfaceIndex FROM IF-MIB; -- ********************************************************************** -- * MODULE IDENTITY -- ********************************************************************** ieee802dot11 MODULE-IDENTITY LAST-UPDATED "202102290000Z" ORGANIZATION "IEEE Std 802.11" CONTACT-INFO "Chair: Dorothy V. Stanley Postal: 29W120 Lost Meadows Lane Warrenville, Illinois 60555 USA Tel: +001 630 363 1389 E-mail: dstanley@ieee.org Editor: Robert Stacey E-mail: rjstacey@ieee.org" DESCRIPTION "The MIB module for IEEE 802.11 entities. iso(1).member-body(2).us(840).ieee802dot11(10036)" REVISION "202102290000Z" DESCRIPTION "IEEE Std 802.11-2020 Note that not all objects within this MIB are referenced by a group, and not all groups are referenced by a MODULE-COMPLIANCE statement. Some existing groups and the dot11Compliance MODULE-COMPLIANCE have been modified since the previous revision of this standard." REVISION "201612140000Z" DESCRIPTION "IEEE Std 802.11-2016. Note that not all objects within this MIB are referenced by a group, and not all groups are referenced by a MODULE-COMPLIANCE statement. Some existing groups and the dot11Compliance MODULE-COMPLIANCE have been modified since the previous revision of this standard. Implementations should not claim compliance to dot11Compliance." ::= { us 10036 } -- ********************************************************************** -- * Tree Definition -- ********************************************************************** member-body OBJECT IDENTIFIER ::= { iso 2 } us OBJECT IDENTIFIER ::= { member-body 840 } -- ********************************************************************** -- * Major sections -- ********************************************************************** -- Station ManagemenT (SMT) Attributes -- DEFINED AS "The SMT object class provides the necessary support -- at the station to manage the processes in the station such that -- the station may work cooperatively as a part of an IEEE 802.11 -- network." dot11smt OBJECT IDENTIFIER ::= { ieee802dot11 1 } -- dot11smt GROUPS -- dot11StationConfigTable ::= { dot11smt 1 } -- dot11AuthenticationAlgorithmsTable ::= { dot11smt 2 } -- dot11WEPDefaultKeysTable ::= { dot11smt 3 } -- dot11WEPKeyMappingsTable ::= { dot11smt 4 } -- dot11PrivacyTable ::= { dot11smt 5 } -- dot11SMTnotification ::= { dot11smt 6 } -- dot11MultiDomainCapabilityTable ::= { dot11smt 7 } -- dot11SpectrumManagementTable ::= { dot11smt 8 } -- dot11RSNAConfigTable ::= { dot11smt 9 } -- dot11RSNAConfigPairwiseCiphersTable ::= { dot11smt 10 } -- dot11RSNAConfigAuthenticationSuitesTable ::= { dot11smt 11 } -- dot11RSNAStatsTable ::= { dot11smt 12 } -- dot11OperatingClassesTable ::= { dot11smt 13 } -- dot11RadioMeasurement ::= { dot11smt 14 } -- dot11FastBSSTransitionConfigTable ::= { dot11smt 15 } -- dot11LCIDSETable ::= { dot11smt 16 } -- dot11HTStationConfigTable ::= { dot11smt 17 } -- dot11WirelessMgmtOptionsTable ::= { dot11smt 18 } -- dot11LocationServicesNextIndex ::= { dot11smt 19 } -- dot11LocationServicesTable ::= { dot11smt 20 } -- dot11WirelessMGTEventTable ::= { dot11smt 21 } -- dot11WirelessNetworkManagement ::= { dot11smt 22 } -- dot11MeshSTAConfigTable ::= { dot11smt 23 } -- dot11MeshHWMPConfigTable ::= { dot11smt 24 } -- dot11RSNAConfigPasswordValueTable ::= { dot11smt 25 } -- dot11RSNAConfigDLCGroupTable ::= { dot11smt 26 } -- dot11DMGSTAConfigTable ::= { dot11smt 27 } -- dot11AVOptionsTable ::= { dot11smt 28 } -- dot11AVConfigTable ::= { dot11smt 29 } -- dot11APCTable ::= { dot11smt 30 } -- dot11VHTStationConfigTable ::= { dot11smt 31 } -- dot11TVHTStationConfigTable ::= { dot11smt 32 } -- dot11STALCITable ::= { dot11smt 33 } -- dot11FILSConfigTable ::= { dot11smt 35 } -- dot11STALCIConfigTable ::= { dot11smt 36 } -- dot11STACivicLocationConfigTable ::= { dot11smt 37 } -- dot11CDMGSTAConfigTable ::= { dot11smt 39 } -- dot11CMMGSTAConfigTable ::= { dot11smt 40 } -- dot11GLKLinkMetricsTable ::= ( dot11smt 41 ) -- MAC Attributes -- DEFINED AS "The MAC object class provides the necessary support -- for the access control, generation, and verification of frame -- check sequences (FCSs), and proper delivery of valid data to -- upper layers." dot11mac OBJECT IDENTIFIER ::= { ieee802dot11 2 } -- MAC GROUPS -- dot11OperationTable ::= { dot11mac 1 } -- dot11CountersTable ::= { dot11mac 2 } -- dot11GroupAddressesTable ::= { dot11mac 3 } -- dot11EDCATable ::= { dot11mac 4 } -- dot11QAPEDCATable ::= { dot11mac 5 } -- dot11QosCountersTable ::= { dot11mac 6 } -- dot11ResourceInfoTable ::= { dot11mac 7 } -- dot11DMGOperationTable ::= { dot11mac 8 } -- dot11DMGCountersTable ::= { dot11mac 9 } -- dot11BSSStatisticsTable ::= { dot11mac 10 } -- dot11CDMGOperationTable ::= { dot11mac 11 } -- Resource Type ID dot11res OBJECT IDENTIFIER ::= { ieee802dot11 3 } dot11resAttribute OBJECT IDENTIFIER ::= { dot11res 1 } -- PHY Attributes -- DEFINED AS "The PHY object class provides the necessary support -- for required PHY operational information that may vary from PHY -- to PHY and from STA to STA to be communicated to upper layers." dot11phy OBJECT IDENTIFIER ::= { ieee802dot11 4 } -- PHY GROUPS -- dot11PhyOperationTable ::= { dot11phy 1 } -- dot11PhyAntennaTable ::= { dot11phy 2 } -- dot11PhyTxPowerTable ::= { dot11phy 3 } -- dot11PhyDSSSTable ::= { dot11phy 5 } -- dot11RegDomainsSupportedTable ::= { dot11phy 7 } -- dot11AntennasListTable ::= { dot11phy 8 } -- dot11SupportedDataRatesTxTable ::= { dot11phy 9 } -- dot11SupportedDataRatesRxTable ::= { dot11phy 10 } -- dot11PhyOFDMTable ::= { dot11phy 11 } -- dot11PhyHRDSSSTable ::= { dot11phy 12 } -- dot11HoppingPatternTable ::= { dot11phy 13 } -- dot11PhyERPTable ::= { dot11phy 14 } -- dot11PhyHTTable ::= { dot11phy 15 } -- dot11SupportedHTMCSTxTable ::= { dot11phy 16 } -- dot11SupportedHTMCSRxTable ::= { dot11phy 17 } -- dot11TransmitBeamformingConfigTable ::= { dot11phy 18 } -- dot11PHYDMGTable ::= { dot11phy 19 } -- dot11DMGBeamformingConfigTable ::= { dot11phy 22 } -- dot11PHYCDMGTable ::= { dot11phy 29 } -- dot11PHYCMMGTable ::= { dot11phy 30 } -- ********************************************************************** -- * Textual conventions for 802 definitions -- ********************************************************************** WEPKeytype ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the type of WEP key." SYNTAX OCTET STRING (SIZE (5)) TSFType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the type of TSF." SYNTAX OCTET STRING (SIZE (8)) -- ********************************************************************** -- * MIB attribute OBJECT-TYPE definitions follow -- ********************************************************************** -- ********************************************************************** -- * dot11StationConfig TABLE -- ********************************************************************** dot11StationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11StationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Station Configuration attributes. In tabular form to allow for multiple instances on an agent." ::= { dot11smt 1 } dot11StationConfigEntry OBJECT-TYPE SYNTAX Dot11StationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11StationConfigTable. It is possible for there to be multiple IEEE 802.11 interfaces on one agent, each with its unique MAC address. The relationship between an IEEE 802.11 interface and an interface in the context of the Internet-standard MIB is one-to-one. As such, the value of an ifIndex object instance can be directly used to identify corresponding instances of the objects defined herein. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11StationConfigTable 1 } Dot11StationConfigEntry ::= SEQUENCE { dot11StationID MacAddress, dot11MediumOccupancyLimit Unsigned32, dot11CFPollable TruthValue, dot11CFPPeriod Unsigned32, dot11CFPMaxDuration Unsigned32, dot11AuthenticationResponseTimeout Unsigned32, dot11PrivacyOptionImplemented TruthValue, dot11PowerManagementMode INTEGER, dot11DesiredSSID OCTET STRING, dot11DesiredBSSType INTEGER, dot11OperationalRateSet OCTET STRING, dot11BeaconPeriod Unsigned32, dot11DTIMPeriod Unsigned32, dot11AssociationResponseTimeout Unsigned32, dot11DisassociateReason Unsigned32, dot11DisassociateStation MacAddress, dot11DeauthenticateReason Unsigned32, dot11DeauthenticateStation MacAddress, dot11AuthenticateFailStatus Unsigned32, dot11AuthenticateFailStation MacAddress, dot11MultiDomainCapabilityImplemented TruthValue, dot11MultiDomainCapabilityActivated TruthValue, dot11CountryString OCTET STRING, dot11SpectrumManagementImplemented TruthValue, dot11SpectrumManagementRequired TruthValue, dot11RSNAOptionImplemented TruthValue, dot11RSNAPreauthenticationImplemented TruthValue, dot11OperatingClassesImplemented TruthValue, dot11OperatingClassesRequired TruthValue, dot11QosOptionImplemented TruthValue, dot11ImmediateBlockAckOptionImplemented TruthValue, dot11DelayedBlockAckOptionImplemented TruthValue, dot11DirectOptionImplemented TruthValue, dot11APSDOptionImplemented TruthValue, dot11QAckOptionImplemented TruthValue, dot11QBSSLoadImplemented TruthValue, dot11QueueRequestOptionImplemented TruthValue, dot11TXOPRequestOptionImplemented TruthValue, dot11MoreDataAckOptionImplemented TruthValue, dot11AssociateInNQBSS TruthValue, dot11DLSAllowedInQBSS TruthValue, dot11DLSAllowed TruthValue, dot11AssociateStation MacAddress, dot11AssociateID Unsigned32, dot11AssociateFailStation MacAddress, dot11AssociateFailStatus Unsigned32, dot11ReassociateStation MacAddress, dot11ReassociateID Unsigned32, dot11ReassociateFailStation MacAddress, dot11ReassociateFailStatus Unsigned32, dot11RadioMeasurementImplemented TruthValue, dot11RadioMeasurementActivated TruthValue, dot11RMMeasurementNavSync Unsigned32, dot11RMMeasurementPilotPeriod Unsigned32, dot11RMLinkMeasurementActivated TruthValue, dot11RMNeighborReportActivated TruthValue, dot11RMParallelMeasurementsActivated TruthValue, dot11RMRepeatedMeasurementsActivated TruthValue, dot11RMBeaconPassiveMeasurementActivated TruthValue, dot11RMBeaconActiveMeasurementActivated TruthValue, dot11RMBeaconTableMeasurementActivated TruthValue, dot11RMBeaconMeasurementReportingConditionsActivated TruthValue, dot11RMFrameMeasurementActivated TruthValue, dot11RMChannelLoadMeasurementActivated TruthValue, dot11RMNoiseHistogramMeasurementActivated TruthValue, dot11RMStatisticsMeasurementActivated TruthValue, dot11RMLCIMeasurementActivated TruthValue, dot11RMLCIAzimuthActivated TruthValue, dot11RMTransmitStreamCategoryMeasurementActivated TruthValue, dot11RMTriggeredTransmitStreamCategoryMeasurementActivated TruthValue, dot11RMAPChannelReportActivated TruthValue, dot11RMMIBActivated TruthValue, dot11RMMaxMeasurementDuration Unsigned32, dot11RMNonOperatingChannelMaxMeasurementDuration Unsigned32, dot11RMMeasurementPilotTransmissionInformationActivated TruthValue, dot11RMMeasurementPilotActivated Unsigned32, dot11RMNeighborReportTSFOffsetActivated TruthValue, dot11RMRCPIMeasurementActivated TruthValue, dot11RMRSNIMeasurementActivated TruthValue, dot11RMBSSAverageAccessDelayActivated TruthValue, dot11RMBSSAvailableAdmissionCapacityActivated TruthValue, dot11RMAntennaInformationActivated TruthValue, dot11FastBSSTransitionImplemented TruthValue, dot11LCIDSEImplemented TruthValue, dot11LCIDSERequired TruthValue, dot11DSERequired TruthValue, dot11ExtendedChannelSwitchActivated TruthValue, dot11RSNAProtectedManagementFramesActivated TruthValue, dot11RSNAUnprotectedManagementFramesAllowed TruthValue, dot11AssociationSAQueryMaximumTimeout Unsigned32, dot11AssociationSAQueryRetryTimeout Unsigned32, dot11HighThroughputOptionImplemented TruthValue, dot11RSNAPBACRequired TruthValue, dot11PSMPOptionImplemented TruthValue, dot11TunneledDirectLinkSetupImplemented TruthValue, dot11TDLSPeerUAPSDBufferSTAActivated TruthValue, dot11TDLSPeerPSMActivated TruthValue, dot11TDLSPeerUAPSDIndicationWindow Unsigned32, dot11TDLSChannelSwitchingActivated TruthValue, dot11TDLSPeerSTAMissingAckRetryLimit Unsigned32, dot11TDLSResponseTimeout Unsigned32, dot11OCBActivated TruthValue, dot11TDLSNavSync Unsigned32, dot11TDLSDiscoveryRequestWindow Unsigned32, dot11TDLSACDeterminationInterval Unsigned32, dot11WirelessManagementImplemented TruthValue, dot11BssMaxIdlePeriod Unsigned32, dot11BssMaxIdlePeriodOptions OCTET STRING, dot11TIMBroadcastInterval Unsigned32, dot11TIMBroadcastOffset Integer32, dot11TIMBroadcastHighRateTIMRate Unsigned32, dot11TIMBroadcastLowRateTIMRate Unsigned32, dot11StatsMinTriggerTimeout Unsigned32, dot11RMCivicMeasurementActivated TruthValue, dot11RMIdentifierMeasurementActivated TruthValue, dot11TimeAdvertisementDTIMInterval Unsigned32, dot11TimeAdvertisementTimeError OCTET STRING, dot11TimeAdvertisementTimeValue OCTET STRING, dot11RM3rdPartyMeasurementActivated TruthValue, dot11InterworkingServiceImplemented TruthValue, dot11InterworkingServiceActivated TruthValue, dot11QosMapImplemented TruthValue, dot11QosMapActivated TruthValue, dot11EBRImplemented TruthValue, dot11EBRActivated TruthValue, dot11ESNetwork TruthValue, dot11SSPNInterfaceImplemented TruthValue, dot11SSPNInterfaceActivated TruthValue, dot11HESSID MacAddress, dot11EASImplemented TruthValue, dot11EASActivated TruthValue, dot11MSGCFImplemented TruthValue, dot11MSGCFActivated TruthValue, dot11MeshActivated TruthValue, dot11RejectUnadmittedTraffic TruthValue, dot11BSSBroadcastNullCount Unsigned32, dot11QMFActivated TruthValue, dot11QMFReconfigurationActivated TruthValue, dot11QMFPolicyChangeTimeout Unsigned32, dot11RobustAVStreamingImplemented TruthValue, dot11MultibandImplemented TruthValue, dot11DynamicEIFSActivated TruthValue, dot11VHTOptionImplemented TruthValue, dot11OperatingModeNotificationImplemented TruthValue, dot11TVHTOptionImplemented TruthValue, dot11ChannelScheduleManagementActivated TruthValue, dot11ContactVerificationSignalActivated TruthValue, dot11ContactVerificationSignalInterval Unsigned32, dot11NetworkChannelControlActivated TruthValue, dot11RLSSActivated TruthValue, dot11WhiteSpaceMapActivated TruthValue, dot11WSSTAType INTEGER, dot11GeolocationCapabilityActivated TruthValue, dot11GDDActivated TruthValue, dot11GDDEnablementTimeLimit Unsigned32, dot11GDDEnablementFailHoldTime Unsigned32, dot11GDDEnablementValidityTimer Unsigned32, dot11MaxMSDULength INTEGER, dot11ExtendedSpectrumManagementImplemented TruthValue, dot11EstimatedServiceParametersInboundOptionImplemented TruthValue, dot11EstimatedServiceParametersOutboundOptionImplemented TruthValue, dot11VHTExtendedNSSBWCapable TruthValue, dot11FutureChannelGuidanceActivated TruthValue, dot11FILSActivated TruthValue, dot11S1GOptionImplemented TruthValue, dot11RSNAOperatingChannelValidationActivated TruthValue, dot11GLKImplemented TruthValue, dot11GLKRequired TruthValue, dot11EPDImplemented TruthValue, dot11EPDRequired TruthValue, dot11GLKLinkRateSamples Unsigned32, dot11GLKLinkRateWindowSize Unsigned32, dot11GLKLinkRateWmin Unsigned32, dot11GLKLinkRateWavg Unsigned32, dot11GLKLinkRateWgeo Unsigned32, dot11GLKLinkRateScaling Unsigned32, dot11GLKLinkRateHysteresis Unsigned32, dot11GLKGCRImplemented TruthValue, dot11SolicitedPADActivated TruthValue, dot11UnsolicitedPADActivated TruthValue, dot11MACPrivacyActivated TruthValue, dot11GASExtensionImplemented TruthValue, dot11LocallyAdministeredMACConfig Unsigned32, dot11BeaconProtectionEnabled TruthValue, dot11MSCSActivated TruthValue, dot11LocalMACAddressPolicyActivated TruthValue, dot11BSSMaxIdlePeriodIndicationByNonAPSTA TruthValue } dot11StationID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive. The purpose of dot11StationID is to allow a manager to identify a station for its own purposes. This attribute provides for that eventuality while keeping the true MAC address independent. Its syntax is MAC address, and the default value is the STA's assigned, unique MAC address." ::= { dot11StationConfigEntry 1 } dot11MediumOccupancyLimit OBJECT-TYPE SYNTAX Unsigned32 (0..1000) UNITS "TUs" MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation." DEFVAL { 100 } ::= { dot11StationConfigEntry 2 } dot11CFPollable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a capability variable. Its value is determined by device capabilities. When this attribute is true, it indicates that the STA is able to respond to a CF-Poll with a Data frame within a SIFS. This attribute is false if the STA is not able to respond to a CF-Poll with a Data frame within a SIFS." ::= { dot11StationConfigEntry 3 } dot11CFPPeriod OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. In an AP, it is written by the MAC when it receives an MLME-START.request primitive. In a non-AP STA, it is written by the MAC when it receives an updated CF Parameter Set in a Beacon frame. The attribute describes the number of DTIM intervals between the start of CFPs. It is modified by MLME-START.request primitive." ::= { dot11StationConfigEntry 4 } dot11CFPMaxDuration OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "TUs" MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. In an AP, it is written by the MAC when it receives an MLME-START.request primitive. In a non-AP STA, it is written by the MAC when it receives an updated CF Parameter Set in a Beacon frame. The attribute describes the maximum duration of the CFP that may be generated by the PCF. It is modified by MLME-START.request primitive." ::= { dot11StationConfigEntry 5 } dot11AuthenticationResponseTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated, as redundant in purpose with the AuthenticateFailureTimeout parameter provided in an MLME-AUTHENTICATE.request. This is a control variable. It is written by an external management entity. Changes take effect for the next Authentication frame. This attribute specifies the number of time units (TUs) that a responding STA should wait for the next frame in the authentication sequence." ::= { dot11StationConfigEntry 6 } dot11PrivacyOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the IEEE 802.11 WEP option is implemented." ::= { dot11StationConfigEntry 7 } dot11PowerManagementMode OBJECT-TYPE SYNTAX INTEGER { active(1), powersave(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an MLME-POWERMGT.request primitive is received. This attribute specifies the power management mode of the STA. When equal to active, it indicates that the station is not in power save (PS) mode. When equal to powersave, it indicates that the station is in power save mode. The power management mode is transmitted in all frames according to the rules in 9.2.4.1.8." ::= { dot11StationConfigEntry 8 } dot11DesiredSSID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-SCAN.request primitive. This attribute reflects the service set identifier (SSID) used in the SSID parameter of the most recent MLME-SCAN.request primitive. This value may be modified by an external management entity and used by the local SME to make decisions about the Scanning process." ::= { dot11StationConfigEntry 9 } dot11DesiredBSSType OBJECT-TYPE SYNTAX INTEGER { infrastructure(1), independent(2), any(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-SCAN.request primitive. This attribute specifies the type of BSS the station uses when scanning for a BSS with which to synchronize. This value is used to filter Probe Response frames and Beacon frames. When equal to infrastructure, the station synchronizes only with a BSS in which the Capability Information field has the ESS subfield equal to 1. When equal to independent, the station synchronizes only with a BSS whose Capability Information field has the IBSS subfield equal to 1. When equal to any, the station may synchronize to either type of BSS." ::= { dot11StationConfigEntry 10 } dot11OperationalRateSet OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..126)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when joining or establishing a BSS. This attribute specifies the set of non-HT data rates at which the station is able to receive data. Each octet contains a value representing a rate. Each rate is within the range 2 to 127, corresponding to data rates in increments of 500 kb/s from 1 Mb/s to 63.5 Mb/s, and is supported (as indicated in the supported rates table) for receiving data. This value is reported in transmitted Beacon, Probe Request, Probe Response, Association Request, Association Response, Reassociation Request, and Reassociation Response frames, and is used to determine whether a BSS with which the station might synchronize is suitable. It is also used when starting a BSS, as specified in 6.3.4." ::= { dot11StationConfigEntry 11 } dot11BeaconPeriod OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. For non-DMG STAs, this attribute specifies the number of TUs that a station uses for scheduling Beacon transmissions. For DMG STAs, this attribute specifies the number of TUs that a station uses for scheduling BTI and/or ATI in the beacon interval. This value is transmitted in Beacon and Probe Response frames." ::= { dot11StationConfigEntry 12 } dot11DTIMPeriod OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies the number of beacon intervals that elapse between transmission of Beacon frames containing a TIM element whose DTIM Count field is 0. This value is transmitted in the DTIM Period field of Beacon frames." ::= { dot11StationConfigEntry 13 } dot11AssociationResponseTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of TU that a requesting STA should wait for a response to a transmitted (Re)Association Request frame." ::= { dot11StationConfigEntry 14 } dot11DisassociateReason OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA disassociates. This attribute holds the most recently transmitted Reason Code in a Disassociation frame. If no Disassociation frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 15 } dot11DisassociateStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA disassociates. This attribute holds the MAC address from the Address 1 field of the most recently transmitted Disassociation frame. If no Disassociation frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 16 } dot11DeauthenticateReason OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA deauthenticates. This attribute holds the most recently transmitted Reason Code in a Deauthentication frame. If no Deauthentication frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 17 } dot11DeauthenticateStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA deauthenticates. This attribute holds the MAC address from the Address 1 field of the most recently transmitted Deauthentication frame. If no Deauthentication frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 18 } dot11AuthenticateFailStatus OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA fails to authenticate. This attribute holds the most recently transmitted Status Code in a failed Authentication frame. If no failed Authentication frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 19 } dot11AuthenticateFailStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA fails to authenticate. This attribute holds the MAC address from the Address 1 field of the most recently transmitted failed Authentication frame. If no failed Authentication frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 20 } dot11MultiDomainCapabilityImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting multiple regulatory domains. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 21 } dot11MultiDomainCapabilityActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive. This attribute, when true, indicates that the capability of the station to operate in multiple regulatory domains is enabled." DEFVAL { false } ::= { dot11StationConfigEntry 22 } dot11CountryString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME. Changes take effect for the next MLME-START.request primitive. This attribute identifies the country or noncountry entity in which the station is operating. If it is a country, the first two octets of this string is the two character country code as described in document ISO 3166-1. The third octet is one of the following: 1. an ASCII space character, if the regulations under which the station is operating encompass all environments for the current frequency band in the country, 2. an ASCII 'O' character, if the regulations under which the station is operating are for an outdoor environment only, or 3. an ASCII 'I' character, if the regulations under which the station is operating are for an indoor environment only. 4. an ASCII 'X' character, if the station is operating under a noncountry entity. The first two octets of the noncountry entity is two ASCII 'XX' characters. 5. the hexadecimal representation of the Operating Class table number currently in use, from the set of tables defined in Annex E, e.g., Table E-1 is represented as x'01'." ::= { dot11StationConfigEntry 23 } dot11SpectrumManagementImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting spectrum management. The capability is disabled otherwise." ::= { dot11StationConfigEntry 24 } dot11SpectrumManagementRequired OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive. A STA uses the defined TPC and DFS procedures if this attribute is true; otherwise it does not use the defined TPC and DFS procedures." DEFVAL { false } ::= { dot11StationConfigEntry 25 } dot11RSNAOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This variable indicates whether the entity is an RSNA STA." ::= { dot11StationConfigEntry 26 } dot11RSNAPreauthenticationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This variable indicates whether the entity supports RSNA preauthentication. This cannot be true unless dot11RSNAOptionImplemented is true." ::= { dot11StationConfigEntry 27 } dot11OperatingClassesImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting operating classes. The capability is disabled otherwise." ::= { dot11StationConfigEntry 28 } dot11OperatingClassesRequired OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive. A STA uses the defined operating classes procedures if this attribute is true." DEFVAL { false } ::= { dot11StationConfigEntry 29 } dot11QosOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting QoS. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 30} dot11ImmediateBlockAckOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting immediate block ack. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 31} dot11DelayedBlockAckOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting delayed block ack. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 32 } dot11DirectOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of sending and receiving frames from a non-AP STA in the BSS. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 33 } dot11APSDOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute is available only at an AP. When true, this attribute indicates that the AP implementation is capable of delivering data and polls to stations using APSD." ::= { dot11StationConfigEntry 34 } dot11QAckOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of interpreting the CF-Ack bit in a received frame with the Type subfield equal to Data even if the frame is not directed to the QoS station. The capability is disabled, otherwise. A STA is capable of interpreting the CF-Ack bit in a received Data frame if that station is the recipient of the Data frame, regardless of the value of this MIB attribute." ::= { dot11StationConfigEntry 35 } dot11QBSSLoadImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute is available only at an AP. This attribute, when true, indicates that the AP implementation is capable of generating and transmitting the BSS load element in the Beacon and Probe Response frames. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 36 } dot11QueueRequestOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute is available only at an AP. This attribute, when true, indicates that the AP is capable of processing the Queue Size field in QoS Control field of QoS Data frames. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 37 } dot11TXOPRequestOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute is available only at an AP. This attribute, when true, indicates that the AP is capable of processing the TXOP Duration requested field in QoS Control field of QoS Data frames. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 38 } dot11MoreDataAckOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of interpreting the More Data bit in the Ack frames. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 39 } dot11AssociateInNQBSS OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the station may associate in a non-QoS BSS. When false, this attribute indicates that the station does not associate in a non-QoS BSS." DEFVAL { true } ::= { dot11StationConfigEntry 40 } dot11DLSAllowedInQBSS OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute available at the AP, when true, indicates that STAs may set up DLS and communicate using DLS with other STAs in the BSS. When false, this attribute indicates that the stations do not set up DLS nor communicate with other STAs using DLS in the BSS." DEFVAL { true } ::= { dot11StationConfigEntry 41 } dot11DLSAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute available at non-AP STAs, when true, indicates that the STA may set up DLS or accept DLS Requests, and communicate with other STAs in the BSS using DLS. When false, this attribute indicates that the STA does not set up DLS nor accept DLS, nor communicate with other STAs in the BSS using DLS." DEFVAL { true } ::= { dot11StationConfigEntry 42} dot11AssociateStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA associates. This attribute indicates the MAC address from the Address 1 field of the most recently transmitted Association Response frame. If no Association Response frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 43 } dot11AssociateID OBJECT-TYPE SYNTAX Unsigned32 (0..2007) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA associates. This attribute indicates the Association ID from the most recently transmitted Association Response frame. If no Association Response frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 44 } dot11AssociateFailStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA fails to associate. This attribute indicates the MAC address from the Address 1 field of the most recently transmitted failed Association Response frame. If no failed Association Response frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 45 } dot11AssociateFailStatus OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA fails to associate. This attribute indicates the most recently transmitted Status Code in a failed Association Response frame. If no failed Association Response frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 46 } dot11ReassociateStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA reassociates. This attribute indicates the MAC address from the Address 1 field of the most recently transmitted Reassociation Response frame. If no Reassociation Response frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 47 } dot11ReassociateID OBJECT-TYPE SYNTAX Unsigned32 (0..2007) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA reassociates. This attribute indicates the Association ID from the most recently transmitted Reassociation Response frame. If no Reassociation Response frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 48 } dot11ReassociateFailStation OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA fails to reassociate. This attribute indicates the MAC address from the Address 1 field of the most recently transmitted failed Reassociation Response frame. If no failed Reassociation Response frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 49 } dot11ReassociateFailStatus OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA fails to reassociate. This attribute indicates the most recently transmitted Status Code in a failed Reassociation Response frame. If no failed Reassociation Response frame has been transmitted, the value of this attribute is 0." ::= { dot11StationConfigEntry 50 } dot11RadioMeasurementImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting Radio Measurement. Otherwise it is not capable of performing Radio Measurement." ::= { dot11StationConfigEntry 51 } dot11RadioMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when any of the MIB attributes listed in 9.4.2.44 is equal to true. Changes take effect with the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that one or more of the Radio Measurement Activated Capabilities MIB attributes, listed in 9.4.2.44, are equal to true. A STA may use the defined Radio Measurement procedures if this attribute is true." DEFVAL { false } ::= { dot11StationConfigEntry 52 } dot11RMMeasurementNavSync OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The value of ProbeDelay to be used when making a beacon type measurement with measurement mode active." ::= { dot11StationConfigEntry 53 } dot11RMMeasurementPilotPeriod OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of TUs that a station uses for scheduling Measurement Pilot frame transmissions. This value is transmitted in Measurement Pilot frames. The default period is 25% of dot11BeaconPeriod." ::= { dot11StationConfigEntry 54 } dot11RMLinkMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Link Measurement is enabled. A value of false indicates the station has no Link Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 55 } dot11RMNeighborReportActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for neighbor report is enabled. false indicates the station has no neighbor report capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 56 } dot11RMParallelMeasurementsActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Parallel Measurements is enabled. false indicates the station has no Parallel Measurements capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 57 } dot11RMRepeatedMeasurementsActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Repeated Measurements is enabled. false indicates the station has no Repeated Measurements capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 58 } dot11RMBeaconPassiveMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Beacon Passive Measurement is enabled. false indicates the station has no Beacon Passive Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 59 } dot11RMBeaconActiveMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Beacon Active Measurement is enabled. false indicates the station has no Beacon Active Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 60 } dot11RMBeaconTableMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Beacon Table Measurement is enabled. false indicates the station has no Beacon Table Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 61 } dot11RMBeaconMeasurementReportingConditionsActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Beacon Measurement Reporting Conditions is enabled. false indicates the station has no Beacon Measurement Reporting Conditions capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 62 } dot11RMFrameMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Frame Measurement is enabled. false indicates the station has no Frame Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 63 } dot11RMChannelLoadMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Channel Load Measurement is enabled. false indicates the station has no Channel Load Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 64 } dot11RMNoiseHistogramMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Noise Histogram Measurement is enabled. false indicates the station has no Noise Histogram Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 65 } dot11RMStatisticsMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Statistics Measurement is enabled. false indicates the station has no Statistics Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 66 } dot11RMLCIMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for LCI Measurement is enabled. false indicates the station has no LCI Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 67 } dot11RMLCIAzimuthActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for LCI Azimuth Measurement is enabled. false indicates the station has no LCI Azimuth Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 68 } dot11RMTransmitStreamCategoryMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Transmit Stream/Category Measurement is enabled. false indicates the station has no Transmit Stream/Category Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 69 } dot11RMTriggeredTransmitStreamCategoryMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Triggered Transmit Stream/Category Measurement is enabled. false indicates the station has no Triggered Transmit Stream/Category Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 70 } dot11RMAPChannelReportActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for AP Channel Report is enabled. false indicates the station has no AP Channel Report capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 71 } dot11RMMIBActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for RM MIB is enabled. false indicates the station has no RM MIB capability or that the capability is present but is disabled. See RM MIB details." DEFVAL { false } ::= { dot11StationConfigEntry 72 } dot11RMMaxMeasurementDuration OBJECT-TYPE SYNTAX Unsigned32 (0 .. 7) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum measurement duration for operating channel measurements, where Max Measurement Duration in TUs = (2 ^ (dot11RMMaxMeasurementDuration - 4)) * BeaconInterval Further details are provided in 11.10.4" ::= { dot11StationConfigEntry 73 } dot11RMNonOperatingChannelMaxMeasurementDuration OBJECT-TYPE SYNTAX Unsigned32 (0 .. 7) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute indicates the maximum measurement duration for nonoperating channel measurements, where Non-OpMax Measurement Duration in TUs = (2 ^ (dot11RMNonOperatingChannelMaxMeasurementDuration - 4)) * BeaconInterval Further details are provided in 11.10.4" ::= { dot11StationConfigEntry 74 } dot11RMMeasurementPilotTransmissionInformationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Measurement Pilot Transmission information is enabled. false indicates the station has no Measurement Pilot Transmission information capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 75 } dot11RMMeasurementPilotActivated OBJECT-TYPE SYNTAX Unsigned32 (0 .. 7) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the station capability for Measurement Pilot. The value 0 indicates the station has no Measurement Pilot capability or that the capability is present but is disabled. Activated values 1-7 are defined in Table 11-10." DEFVAL { 0 } ::= { dot11StationConfigEntry 76 } dot11RMNeighborReportTSFOffsetActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Neighbor Report TSF Offset is enabled. false indicates the station has no Neighbor Report TSF Offset capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 77 } dot11RMRCPIMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for RCPI Measurement is enabled. false indicates the station has no RCPI Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 78 } dot11RMRSNIMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for RSNI Measurement is enabled. false indicates the station has no RSNI Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 79 } dot11RMBSSAverageAccessDelayActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for BSS Average Access Delay is enabled. false indicates the station has no BSS Average Access Delay capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 80 } dot11RMBSSAvailableAdmissionCapacityActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for BSS Available Admission Capacity is enabled. false indicates the station has no BSS Available Admission Capacity capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 81 } dot11RMAntennaInformationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Antenna information is enabled. false indicates the station has no Antenna information capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 82 } dot11FastBSSTransitionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This object indicates if the entity is fast BSS transition capable." ::= { dot11StationConfigEntry 83 } dot11LCIDSEImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting LCI DSE. The capability is disabled, otherwise." ::= { dot11StationConfigEntry 84 } dot11LCIDSERequired OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME. A STA uses the Dependent Station Enablement procedures if this attribute is true." DEFVAL { false } ::= { dot11StationConfigEntry 85 } dot11DSERequired OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME. This attribute, when true, indicates that the station operation is dependent on enablement from enabling STAs. This attribute, when false, indicates that the station operation does not depend on enablement from STAs." DEFVAL { false } ::= { dot11StationConfigEntry 86 } dot11ExtendedChannelSwitchActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized for operation in a band defined by an Operating Class. This attribute, when true, indicates that the capability of the station to perform extended channel switching is enabled." DEFVAL { false } ::= { dot11StationConfigEntry 87 } --********************************************************** --* Management frame protection MIBs --********************************************************** dot11RSNAProtectedManagementFramesActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable indicates whether this STA enables management frame protection." DEFVAL { false } ::= { dot11StationConfigEntry 88} dot11RSNAUnprotectedManagementFramesAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable indicates whether this STA supports RSNA STAs which do not provide management frame protection." DEFVAL { true } ::= { dot11StationConfigEntry 89} --********************************************************** --* SA Query Procedure MIBs --********************************************************** dot11AssociationSAQueryMaximumTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of TUs that an AP can wait, from the scheduling of the first SA Query Request to allow association process to be started without starting additional SA Query procedure if a successful SA Query Response is not received." DEFVAL { 1000 } ::= { dot11StationConfigEntry 90} dot11AssociationSAQueryRetryTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of TUs that an AP waits between issuing two subsequent MLME-SA-QUERY.request primitive primitives." DEFVAL { 201 } ::= { dot11StationConfigEntry 91} dot11HighThroughputOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates whether the entity is HT capable." ::= { dot11StationConfigEntry 92} dot11RSNAPBACRequired OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable indicates whether this STA requires the Protection of block ack agreements." DEFVAL { false } ::= { dot11StationConfigEntry 93} dot11PSMPOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting PSMP." ::= { dot11StationConfigEntry 94 } dot11TunneledDirectLinkSetupImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. This attribute, when true, indicates that the STA implementation is capable of supporting tunneled direct-link setup." ::= { dot11StationConfigEntry 95 } dot11TDLSPeerUAPSDBufferSTAActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. This attribute, when true, indicates that the STA implementation is capable of supporting TPU." ::= { dot11StationConfigEntry 96 } dot11TDLSPeerPSMActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. This attribute, when true, indicates that the STA implementation is capable of supporting TDLS peer PSM." ::= { dot11StationConfigEntry 97 } dot11TDLSPeerUAPSDIndicationWindow OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. This attribute indicates the minimum interval in Beacon Intervals between successive Peer Traffic Indication frames." DEFVAL { 1 } ::= { dot11StationConfigEntry 98 } dot11TDLSChannelSwitchingActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. This attribute, when true, indicates that the STA implementation is capable of supporting TDLS Channel Switching." ::= { dot11StationConfigEntry 99 } dot11TDLSPeerSTAMissingAckRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. This attribute indicates the number of times the TDLS STA may retry a frame for which it does not receive an Ack frame from TDLS peer STA in power save mode after the TDLS peer STA does not receive an Ack frame to an individually addressed MPDU sent with the EOSP subfield equal to 1 or to an individually addressed MPDU that initiated a channel switch." DEFVAL { 3 } ::= { dot11StationConfigEntry 100 } dot11TDLSResponseTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..255) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. This attribute indicates the amount of time the STA waits before timing out a TDLS setup request." DEFVAL { 5 } ::= { dot11StationConfigEntry 101 } dot11OCBActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. A STA uses the defined outside the context of a BSS procedures if and only if this attribute is true." DEFVAL { false } ::= { dot11StationConfigEntry 102 } dot11TDLSNavSync OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. This attribute indicates the amount of time the STA waits before transmitting on a new channel, in the absence of traffic on the channel that causes a CCA state to be created." DEFVAL { 1000 } ::= { dot11StationConfigEntry 103 } dot11TDLSDiscoveryRequestWindow OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. This attribute indicates the minimum number of DTIM intervals between successive TDLS Discovery Request frames." DEFVAL { 2 } ::= { dot11StationConfigEntry 104 } dot11TDLSACDeterminationInterval OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. This attribute indicates the number of seconds during which the lowest AC of transmitted traffic is determined." DEFVAL { 1 } ::= { dot11StationConfigEntry 105 } dot11WirelessManagementImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting one or more wireless network management services." ::= { dot11StationConfigEntry 106} dot11BssMaxIdlePeriod OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "1000 TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. At an AP, this attribute indicates that the time period that passes before an AP disassociates an inactive non-AP STA. This value may be overriden by the AP based on the non-AP STA indication, if any, in the (Re)Association Request frame. The (overriden, if needed) value is transmitted in the (Re)Association Response frame. At a non-AP STA, this attribute indicates the requested time before which the AP should not disassociate the inactive non-AP STA due to inactivity. This value might be transmitted in the (Re)Association Request frame." ::= { dot11StationConfigEntry 107} dot11BssMaxIdlePeriodOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the options associated with the BSS max idle capability. This value is transmitted in the Association Response and Reassociation Response frames." ::= { dot11StationConfigEntry 108} dot11TIMBroadcastInterval OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the number of beacon periods between TIM frame transmissions. A value of 0 disables TIM Broadcast for the requesting station." DEFVAL { 0 } ::= { dot11StationConfigEntry 109} dot11TIMBroadcastOffset OBJECT-TYPE SYNTAX Integer32 (-214748364..214748363) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the offset with a tolerance of +/- 4 microseconds relative to the TBTT for which a TIM frame is scheduled for transmission." DEFVAL { 0 } ::= { dot11StationConfigEntry 110} dot11TIMBroadcastHighRateTIMRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "0.5 Mb/s" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the rate used to transmit the high data rate TIM frame. A value of 0 indicates that the high data rate TIM frame is not transmitted." DEFVAL { 0 } ::= { dot11StationConfigEntry 111} dot11TIMBroadcastLowRateTIMRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "0.5 Mb/s" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the rate used to transmit the low data rate TIM frame. A value of 0 indicates that the low data rate TIM frame is not transmitted." DEFVAL { 0 } ::= { dot11StationConfigEntry 112} dot11StatsMinTriggerTimeout OBJECT-TYPE SYNTAX Unsigned32 (10..7200) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum allowable value for Triggered Timeout. A Triggered STA Statistics report is generated by the STA after the timeout if none of the trigger conditions are satisfied." DEFVAL { 10 } ::= { dot11StationConfigEntry 113 } dot11RMCivicMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Location Civic Measurement is enabled. false indicates the station has no Location Civic Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 114 } dot11RMIdentifierMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for location identifier measurement is enabled. false indicates the station has no Location Identifier Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 115 } dot11TimeAdvertisementDTIMInterval OBJECT-TYPE SYNTAX Unsigned32 (1..255) UNITS "dtims" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the interval in number of DTIMS when the Time Advertisement element is included in Beacon frames." DEFVAL { 1 } ::= { dot11StationConfigEntry 116 } dot11InterworkingServiceImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute when true, indicates the STA is capable of interworking with external networks. A STA setting this to true implements Interworking Service. When this is false, the STA does not implement Interworking Service." ::= { dot11StationConfigEntry 117 } dot11InterworkingServiceActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute when true, indicates the capability of the STA to interwork with external networks is enabled. The capability is disabled otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 118 } dot11QosMapImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute available at STAs, when true, indicates the STA is capable of supporting the QoS Map procedures. When this is false, the STA does not implement QoS Map procedures." ::= { dot11StationConfigEntry 119 } dot11QosMapActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates the capability of the STA to support QoS Map procedures is enabled. The capability is disabled otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 120 } dot11EBRImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute available at STAs, when true, indicates the STA is capable of supporting Expedited Bandwidth Request procedures. When this is false, the STA does not implement Expedited Bandwidth Request procedures." ::= { dot11StationConfigEntry 121 } dot11EBRActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates the capability of the STA to support Expedited Bandwidth Request procedures is enabled. The capability is disabled otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 122 } dot11ESNetwork OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The emergency services access network type equal to true indicates that the BSS is used exclusively for the purposes of accessing emergency services. This object is not used by non-AP STAs." ::= { dot11StationConfigEntry 123 } dot11SSPNInterfaceImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute when true, indicates the AP is capable of SSPN Interface service. When this is false, the STA does not implement SSPN Interface Service. This object is not used by non-AP STAs." ::= { dot11StationConfigEntry 124 } dot11SSPNInterfaceActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates the capability of the AP to provide SSPN Interface service is enabled. The capability is disabled, otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 125 } dot11HESSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect for the next MLME-START.request primitive. This attribute is used by an AP and is the 6-octet homogeneous ESS identifier field, whose value is set to one of the BSSIDs in the ESS. It is required that the same value of HESSID be used for all BSSs in the homogeneous ESS." ::= { dot11StationConfigEntry 126 } dot11EASImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute when true, indicates the STA is capable of emergency alert system notification with external networks. A STA setting this to true implements emergency alert system notification. When this is false, the STA does not implement emergency alert system notification." ::= { dot11StationConfigEntry 127 } dot11EASActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute when true, indicates the STA is capable of supporting emergency alert system. The capability is disabled otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 128 } dot11MSGCFImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute when true, indicates the non-AP STA is capable of supporting the MSGCF procedures defined in 6.4. When false, the non-AP STA does not implement MSGCF procedures. This object is not used by APs." ::= { dot11StationConfigEntry 129 } dot11MSGCFActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates the capability of the non-AP STA to provide the MSGCF is enabled. The capability is disabled, otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 130 } dot11TimeAdvertisementTimeError OBJECT-TYPE SYNTAX OCTET STRING (SIZE(5)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the Time Error value as defined in the Time Advertisement element Time Error field when the Time Capabilities field is set to 2. This field is included in the Time Advertisement element in Beacon and Probe Response frames." DEFVAL { ''H } ::= { dot11StationConfigEntry 131 } dot11TimeAdvertisementTimeValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the TimeAdvertisement Time Value as defined in the Time Advertisement element Time Value field when the Time Capabilities field is set to 2. The format is defined in Table 9-192 and is included in the Time Advertisement element in Beacon and Probe Response frames." ::= { dot11StationConfigEntry 132 } dot11RM3rdPartyMeasurementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that dot11RadioMeasurementActivated is true and that the station capability for Third Party Location Measurement is enabled. false indicates the station has no Third Party Location Measurement capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 133 } dot11RejectUnadmittedTraffic OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect at the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute when true indicates the STA rejects MA-UNITDATA.requests whose requested priority corresponds to an AC for which admission control is mandatory and for which there is not an admitted TSPEC." DEFVAL { false } ::= {dot11StationConfigEntry 134} dot11BSSBroadcastNullCount OBJECT-TYPE SYNTAX Unsigned32 (1..64) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated because this attribute is not referenced in IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of group addressed (QoS) Null frames an IBSS STA transmits before it changes power management modes." DEFVAL { 3 } ::= {dot11StationConfigEntry 135} dot11MeshActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. When this object is true, this indicates that the STA is a mesh STA. Configuration variables for mesh operation are found in the dot11MeshSTAConfigTable." ::= { dot11StationConfigEntry 136 } dot11QMFActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. In an AP changes take effect for the next MLME-START.request primitive. In a non-AP STA that is not associated and is not an IBSS STA, changes take effect as soon as practical in the implementation. In a non-AP STA that is associated, changes take effect at the end of the lifetime of the association. For a STA that is an IBSS STA, changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute indicates whether the entity is QMF enabled or disabled." DEFVAL { false } ::= { dot11StationConfigEntry 137 } dot11QMFReconfigurationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. The purpose of dot11QMFReconfigurationActivated is to allow an SME to accept a QMF Policy Change request from another STA and respond with a QMF Policy frame." DEFVAL { false } ::= { dot11StationConfigEntry 138 } dot11QMFPolicyChangeTimeout OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum number of TUs that a STA waits to receive a response to a QMF Policy Change request before declaring that the request has failed and also the number of TUs that a STA waits after it has received a rejection to a QMF Policy Change request before issuing a repeat QMF Policy Change request to the same destination STA." DEFVAL { 5000 } ::= { dot11StationConfigEntry 139 } dot11RobustAVStreamingImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation supports robust AV streaming." ::= { dot11StationConfigEntry 140 } dot11VHTOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates whether the entity is VHT capable." ::= { dot11StationConfigEntry 141} dot11OperatingModeNotificationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates whether the entity is Operating Mode Notification Capable." ::= { dot11StationConfigEntry 142} dot11TVHTOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates whether the entity is TVHT capable." ::= { dot11StationConfigEntry 143} dot11MultibandImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Multi-band Support Activated This attribute, when true, indicates that the STA is capable of operating in multiple bands. Otherwise, it is false." ::= { dot11StationConfigEntry 144 } dot11ChannelScheduleManagementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when the device is initialized for operation in a band defined by an Operating Class. This attribute, when true, indicates that the STA implementation is capable of supporting Channel Schedule Management Announcement. The capability is disabled, otherwise." DEFVAL { false } ::= { dot11StationConfigEntry 145 } dot11ContactVerificationSignalActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive primitive. This attribute, when true, indicates that the system capability for contact verification signal is activated. false indicates that the STA has contact verification signal capability, but it is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 146 } dot11ContactVerificationSignalInterval OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. dot11ContactVerificationSignalInterval indicates the maximum number of seconds that a GDD dependent STA may wait to receive the Contact Verification Signal frame before stopping operation in TVWS. Unless another value is mandated by regulatory authorities, the value is 60 seconds." DEFVAL { 60 } ::= { dot11StationConfigEntry 147 } dot11NetworkChannelControlActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when the device is initialized for operation in a band defined by an Operating Class. This attribute, when true, indicates that the STA implementation is capable of supporting network channel control. The capability is disabled, otherwise." DEFVAL { false } ::= { dot11StationConfigEntry 148 } dot11RLSSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as possible in the device. This attribute, when true, indicates that the RLQP capability is activated. The capability is disabled, otherwise." DEFVAL { false } ::= { dot11StationConfigEntry 149 } dot11WhiteSpaceMapActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that the STA capability for white space map is activated. false indicates the STA has no white space map capability or that the capability is present but is disabled." DEFVAL { false } ::= { dot11StationConfigEntry 150 } dot11WSSTAType OBJECT-TYPE SYNTAX INTEGER {gddap(1), gddnonapsta(2), gddfixedsta(3), reserved(4)} MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when the device is initialized for operation in a band that requires Geolocation Database Control. This attribute specifies the type of STA mode for the purpose of channel availability query requirements. This value is used to set the desired channel availability query request parameters in using GAS frames carrying Channel Availability Query element of RLQP. When set to gddap, the STA indicates that it operates as a personal/portable AP after channel availability query. When set to gddnonapsta, the STA indicates that it operates as a personal/portable non-AP STA after channel availability query. When set to gddfixedsta, the STA indicates that it operates as a fixed STA after channel availability query. When set to any other values, its use is reserved, and remains unspecified." ::= { dot11StationConfigEntry 151} dot11GeolocationCapabilityActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the has obtained its device location information in geospatial coordinates for its position using its geolocation capability, as required for its device class, otherwise this is false." DEFVAL { false } ::= { dot11StationConfigEntry 152 } dot11GDDActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when the device is initialized for operation in a band that requires Geolocation Database Dependent behavior. This attribute, when true, indicates that the STA capability for operation with Geolocation Database Dependent behavior is activated. The capability is disabled, otherwise." DEFVAL { false } ::= { dot11StationConfigEntry 153 } dot11GDDEnablementTimeLimit OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when the device is initialized. Changes take effect as soon as practical in the implementation. dot11GDDEnablementTimeLimit indicates the maximum number of seconds that a GDD dependent STA may transmit in a frequency band under the control of a geolocation database while attaining GDD enablement with a GDD enabling STA. Unless another value is mandated by regulatory authorities, the value is 32 seconds." DEFVAL { 32 } ::= { dot11StationConfigEntry 155 } dot11GDDEnablementFailHoldTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when the device is initialized. Changes take effect as soon as practical in the implementation. dot11GDDEnablementFailHoldTime indicates the number of seconds that a GDD dependent STA shall not transmit in a frequency band under control of a geolocation database when it fails to attain GDD enablement with an GDD enabling STA within dot11GDDEnablementTimeLimit seconds. Unless another value is mandated by regulatory authorities, the value is 512 seconds." DEFVAL { 512 } ::= { dot11StationConfigEntry 156 } dot11GDDEnablementValidityTimer OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the SME when the device is initialized. Changes take effect as soon as practical in the implementation. dot11GDDEnablementValidityTimer indicates the number of seconds that a GDD dependent STA remains in GDDEnabled state. Unless another value is mandated by regulatory authorities, the value is 60 seconds." DEFVAL { 60 } ::= { dot11StationConfigEntry 157 } dot11MaxMSDULength OBJECT-TYPE SYNTAX INTEGER { normal(2304), long(7920) } UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum supported MSDU size. This is 7920 octets for a DMG STA and 2304 octets for a non-DMG STA." ::= { dot11StationConfigEntry 162 } dot11DynamicEIFSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute indicates whether the entity uses a dynamic value for EIFS based on properties of the PPDU that causes the EIFS, or a fixed value." ::= { dot11StationConfigEntry 158 } dot11S1GOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates whether the entity is S1G Capable." ::= { dot11StationConfigEntry 159 } dot11FILSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that FILS is enabled." DEFVAL {false} ::= { dot11StationConfigEntry 160 } dot11ExtendedSpectrumManagementImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the non-VHT station implementation is capable of supporting extended spectrum management. The capability is disabled at the non-VHT station otherwise." ::= { dot11StationConfigEntry 161 } dot11EstimatedServiceParametersInboundOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the IEEE 802.11 Estimated Service Parameters Inbound option is implemented." ::= { dot11StationConfigEntry 163 } dot11VHTExtendedNSSBWCapable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the VHT extended NSS BW support option is implemented. dot11VHTExtendedNSSBWCapable might be false when dot11VHTOptionImplemented is false." ::= { dot11StationConfigEntry 165 } dot11FutureChannelGuidanceActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates the capability of the STA to support Future channel guidance procedures is enabled. The capability is disabled otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 166 } dot11SolicitedPADActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute when true, indicates that the capability of the STA to operate solicited PAD with external networks is enabled. The capability is disabled otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 167 } dot11UnsolicitedPADActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute when true, indicates that the capability of the STA to operate unsolicited PAD with external networks is enabled. The capability is disabled otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 168 } dot11GLKImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When true, this attribute indicates a GLK capable STA. When false, it indicates a non-GLK capable STA. This is a capability variable." ::= { dot11StationConfigEntry 169 } dot11GLKRequired OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When true, this attribute indicates a STA that will not accept associations from or peer with a non-GLK capable STA. When false, it indicates a STA that will peer with or accept associations from a non-GLK capable STA. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation." ::= { dot11StationConfigEntry 170 } dot11EPDImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When true, this attribute indicates a STA that supports the receipt and transmission of EPD MSDUs. When false, it indicates a STA that does not support EPD. This is a capability variable." ::= { dot11StationConfigEntry 171 } dot11EPDRequired OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "When true, this attribute indicates a STA that will only associate, direct link, or peer with a STA supporting EPD. When false, it indicates a STA that will associate, direct link, or peer with a STA that does not support EPD. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation." ::= { dot11StationConfigEntry 172 } dot11GLKLinkRateSamples OBJECT-TYPE SYNTAX Unsigned32 (2..257) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the number of data bit rate sample windows in the array of such values used in the determination of the data rate metrics for general links. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation." DEFVAL { 8 } ::= { dot11StationConfigEntry 173 } dot11GLKLinkRateWindowSize OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "The size of the data bit rate sample window duration in units of 16 TUs. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation." DEFVAL { 8 } ::= { dot11StationConfigEntry 174 } dot11GLKLinkRateWmin OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the relative weight given to the minimum bit rate observed in the data rate sample windows on a general link or peering. A larger value means more weight or influence for the minimum observed bit rate. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. It is used in the determination of the data rate metrics for general links." DEFVAL { 50 } ::= { dot11StationConfigEntry 175 } dot11GLKLinkRateWavg OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the relative weight given to the arithmetic mean bit rate observed in the data rate sample windows on a general link or peering. A larger value means more weight or influence for the arithmetic mean observed bit rate. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. It is used in the determination of the data rate metrics for general links." DEFVAL { 50 } ::= { dot11StationConfigEntry 176 } dot11GLKLinkRateWgeo OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the relative weight given to the geometric mean of the bit rates observed in the data rate sample windows on a general link or peering. A larger value means more weight or influence for the geometric mean of the observed bit rates. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. It is used in the determination of the data rate metrics for general links." DEFVAL { 50 } ::= { dot11StationConfigEntry 177 } dot11GLKLinkRateScaling OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is used to scale the data rate reported appropriately depending on the use of that rate and how pessimistically data rates are being determined. A scaling of 16 would produce a data rate suitable for use in IEEE 802.1Q protocols with no pessimism. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation." DEFVAL { 10 } ::= { dot11StationConfigEntry 178 } dot11GLKLinkRateHysteresis OBJECT-TYPE SYNTAX Unsigned32 (1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "This value is used to apply hysteresis to the data rate reported for a general link. If it contains 256, then any change in rate is immediately reported. The smaller its value, the larger the change that occurs before that change is reported. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation." DEFVAL { 200 } ::= { dot11StationConfigEntry 179 } dot11GLKGCRImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "When true, this attribute indicates a GLK-GCR capable STA. When false, this attribute indicates a GLK capable STA that does not support GLK-GCR or a STA that is not GLK capable. This is a capability variable." ::= { dot11StationConfigEntry 180 } dot11GASExtensionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA is capable of operating in GAS extension in GAS frame exchanges. Otherwise, it is false." ::= { dot11StationConfigEntry 183 } dot11MACPrivacyActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute when true, indicates that the STA enables MAC privacy considerations. The capability is disabled otherwise." DEFVAL {false} ::= { dot11StationConfigEntry 184 } dot11LocallyAdministeredMACConfig OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute identifies an addressing plan to use for when associating with the BSS. 0: local addresses comply with the Structured Local Address Plan as defined in IEEE Std 802c-2017 1: local addresses are constructed according to vendor-specific local address plan." DEFVAL {0} ::= { dot11StationConfigEntry 185 } dot11EstimatedServiceParametersOutboundOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the IEEE 802.11 Estimated Service Parameters Outbound option is implemented." ::= { dot11StationConfigEntry 191 } dot11RSNAOperatingChannelValidationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable indicates whether this STA has enabled operating channel validation in an RSNA." DEFVAL {false} ::= { dot11StationConfigEntry 192 } dot11BeaconProtectionEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable indicates whether beacon protection is enabled. If dot11BeaconProtectionEnabled is true for an AP, beacon protection is enabled on transmission. If dot11BeaconProtectionEnabled is true for a non-AP STA and the STA receives a BIGTK from the AP with which it is associated, beacon protection is enabled on reception. Otherwise, beacon protection is disabled." DEFVAL {false} ::= { dot11StationConfigEntry 195 } dot11MSCSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC or an external management entity. Changes take effect as soon as practical in the implementation. This variable indicates whether support for Mirrored SCS is enabled on the STA." DEFVAL {false} ::= { dot11StationConfigEntry 197 } dot11LocalMACAddressPolicyActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates the presence of a local MAC address policy to be advertised." DEFVAL {false} ::= { dot11StationConfigEntry 188 } dot11BSSMaxIdlePeriodIndicationByNonAPSTA OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute is only present for a non-S1G STA. This attribute, when true at a non-AP STA, indicates that the STA might include the BSS Max Idle Period element in (Re)Association Request frames. This attribute, when true at an AP, indicates that the AP might consider the value of the Max Idle Period subfield in the BSS Max Idle Period element in the (Re)Association Request frame in setting the Max Idle Period subfield in the BSS Max Idle Period element in the (Re)Association Response frame." ::= { dot11StationConfigEntry 200 } -- ********************************************************************** -- * End of dot11StationConfig TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11AuthenticationAlgorithms TABLE -- ********************************************************************** dot11AuthenticationAlgorithmsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11AuthenticationAlgorithmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This (conceptual) table of attributes is a set of all of the authentication algorithms and whether they are activated." ::= { dot11smt 2 } dot11AuthenticationAlgorithmsEntry OBJECT-TYPE SYNTAX Dot11AuthenticationAlgorithmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the Authentication Algorithms Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11AuthenticationAlgorithmIndex} ::= { dot11AuthenticationAlgorithmsTable 1 } Dot11AuthenticationAlgorithmsEntry ::= SEQUENCE { dot11AuthenticationAlgorithmIndex Unsigned32, dot11AuthenticationAlgorithm INTEGER, dot11AuthenticationAlgorithmActivated TruthValue } dot11AuthenticationAlgorithmIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the Authentication Algorithms Table." ::= { dot11AuthenticationAlgorithmsEntry 1 } dot11AuthenticationAlgorithm OBJECT-TYPE SYNTAX INTEGER { openSystem(1), sharedKey(2), fastBSSTransition(3), simultaneousAuthEquals(4), filsSharedKeyWithoutPFS(5), filsSharedKeyWithPFS(6), filsPublicKey(7)} MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute is the authentication algorithm described by this entry in the table. The following values can be used here Value = 1: Open system Value = 2: Shared key Value = 3: Fast BSS transition (FT) Value = 4: Simultaneous authentication of equals (SAE) Value = 5: FILS Shared Key authentication without PFS Value = 6: FILS Shared Key authentication with PFS Value = 7: FILS Public Key authentication A given value shall not be used more than once." ::= { dot11AuthenticationAlgorithmsEntry 2 } dot11AuthenticationAlgorithmActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, enables the acceptance of the authentication algorithm described in the corresponding table entry in authentication frames received that have odd authentication transactions sequence numbers. The value of this attribute is true when the value of dot11AuthenticationAlgorithm is openSystem and false otherwise." ::= { dot11AuthenticationAlgorithmsEntry 3 } -- ********************************************************************** -- * End of dot11AuthenticationAlgorithms TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11WEPDefaultKeys TABLE -- ********************************************************************** dot11WEPDefaultKeysTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WEPDefaultKeysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual table for WEP default keys. This table contains the four WEP default secret key values corresponding to the four possible Key ID values. The WEP default secret keys are logically WRITE-ONLY. Attempts to read the entries in this table return unsuccessful status and values of null or 0. The default value of each WEP default key is null." ::= { dot11smt 3 } dot11WEPDefaultKeysEntry OBJECT-TYPE SYNTAX Dot11WEPDefaultKeysEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the WEP Default Keys Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11WEPDefaultKeyIndex } ::= { dot11WEPDefaultKeysTable 1 } Dot11WEPDefaultKeysEntry ::= SEQUENCE { dot11WEPDefaultKeyIndex Unsigned32, dot11WEPDefaultKeyValue WEPKeytype } dot11WEPDefaultKeyIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the WEP Default Keys Table. The value of this variable is equal to the WEPDefaultKeyID + 1" ::= { dot11WEPDefaultKeysEntry 1 } dot11WEPDefaultKeyValue OBJECT-TYPE SYNTAX WEPKeytype MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. A WEP default secret key value." ::= { dot11WEPDefaultKeysEntry 2 } -- ********************************************************************** -- * End of dot11WEPDefaultKeys TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11WEPKeyMappings TABLE -- ********************************************************************** dot11WEPKeyMappingsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WEPKeyMappingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual table for WEP Key Mappings. The MIB supports the ability to share a separate WEP key for each RA/TA pair. The Key Mappings Table contains zero or one entries for each MAC address and contains two fields for each entry: WEPOn and the corresponding WEP key. The WEP key mappings are logically WRITE-ONLY. Attempts to read the entries in this table return unsuccessful status and values of null or 0. The default value for all WEPOn fields is false." ::= { dot11smt 4 } dot11WEPKeyMappingsEntry OBJECT-TYPE SYNTAX Dot11WEPKeyMappingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the WEP Key Mappings Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11WEPKeyMappingIndex } ::= { dot11WEPKeyMappingsTable 1 } Dot11WEPKeyMappingsEntry ::= SEQUENCE { dot11WEPKeyMappingIndex Unsigned32, dot11WEPKeyMappingAddress MacAddress, dot11WEPKeyMappingWEPOn TruthValue, dot11WEPKeyMappingValue WEPKeytype, dot11WEPKeyMappingStatus RowStatus } dot11WEPKeyMappingIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the WEP Key Mappings Table." ::= { dot11WEPKeyMappingsEntry 1 } dot11WEPKeyMappingAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The MAC address of the STA for which the values from this key mapping entry are to be used." ::= { dot11WEPKeyMappingsEntry 2 } dot11WEPKeyMappingWEPOn OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Boolean as to whether WEP is to be used when communicating with the dot11WEPKeyMappingAddress STA." ::= { dot11WEPKeyMappingsEntry 3 } dot11WEPKeyMappingValue OBJECT-TYPE SYNTAX WEPKeytype MAX-ACCESS read-create STATUS current DESCRIPTION "A WEP secret key value." ::= { dot11WEPKeyMappingsEntry 4 } dot11WEPKeyMappingStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status column used for creating, modifying, and deleting instances of the columnar objects in the WEP key mapping Table." DEFVAL { active } ::= { dot11WEPKeyMappingsEntry 5 } -- ********************************************************************** -- * End of dot11WEPKeyMappings TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11Privacy TABLE -- ********************************************************************** dot11PrivacyTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PrivacyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group containing attributes concerned with IEEE 802.11 Privacy. Created as a table to allow multiple instantiations on an agent." ::= { dot11smt 5 } dot11PrivacyEntry OBJECT-TYPE SYNTAX Dot11PrivacyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PrivacyTable Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PrivacyTable 1 } Dot11PrivacyEntry ::= SEQUENCE { dot11PrivacyInvoked TruthValue, dot11WEPDefaultKeyID Unsigned32, dot11WEPKeyMappingLengthImplemented Unsigned32, dot11ExcludeUnencrypted TruthValue, dot11WEPICVErrorCount Counter32, dot11WEPExcludedCount Counter32, dot11RSNAActivated TruthValue, dot11RSNAPreauthenticationActivated TruthValue } dot11PrivacyInvoked OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. When this attribute is true, it indicates that some level of security is invoked for transmitting Data frames. For WEP-only clients, the security mechanism used is WEP. For RSNA non-AP STAs, an additional variable dot11RSNAActivated indicates whether RSNA is enabled. If dot11RSNAActivated is false or the MIB attribute does not exist, the security mechanism invoked is WEP; if dot11RSNAActivated is true, RSNA security mechanisms invoked are configured in the dot11RSNAConfigTable." DEFVAL { false } ::= { dot11PrivacyEntry 1 } dot11WEPDefaultKeyID OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the use of the first, second, third, or fourth element of the WEPDefaultKeys array when equal to values of zero, one, two, or three." DEFVAL { 0 } ::= { dot11PrivacyEntry 2 } dot11WEPKeyMappingLengthImplemented OBJECT-TYPE SYNTAX Unsigned32 (10..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The maximum number of tuples that dot11WEPKeyMappings can hold." ::= { dot11PrivacyEntry 3 } dot11ExcludeUnencrypted OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. When this attribute is true, the STA does not indicate at the MAC service interface received MSDUs that have the Protected Frame subfield of the Frame Control field equal to 0. When this attribute is false, the STA may accept MSDUs that have the Protected Frame subfield of the Frame Control field equal to 0." DEFVAL { false } ::= { dot11PrivacyEntry 4 } dot11WEPICVErrorCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an ICV error is detected. This counter increments when a frame is received with the Protected Frame subfield of the Frame Control field equal to 1 and the value of the ICV as received in the frame does not match the ICV value that is calculated for the contents of the received frame. ICV errors for TKIP are not counted in this variable but in dot11RSNAStatsTKIPICVErrors." ::= { dot11PrivacyEntry 5 } dot11WEPExcludedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a bad frame is received. This counter increments when a frame is received with the Protected Frame subfield of the Frame Control field equal to 0 and the value of dot11ExcludeUnencrypted causes that frame to be discarded." ::= { dot11PrivacyEntry 6 } dot11RSNAActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. When this object is true, this indicates that RSNA is enabled on this entity. Configuration variables for RSNA operation are found in the dot11RSNAConfigTable. This object requires that dot11PrivacyInvoked also be equal to true." ::= { dot11PrivacyEntry 7 } dot11RSNAPreauthenticationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. When this object is true, this indicates that RSNA preauthentication is enabled on this entity. This object requires that dot11RSNAActivated also be equal to true." ::= { dot11PrivacyEntry 8 } -- ********************************************************************** -- * End of dot11Privacy TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11SMTnotification Objects -- ********************************************************************** dot11SMTnotification OBJECT IDENTIFIER ::= { dot11smt 6 } dot11Disassociate NOTIFICATION-TYPE OBJECTS { ifIndex, dot11DisassociateReason, dot11DisassociateStation } STATUS current DESCRIPTION "The disassociate notification is sent when the STA sends a Disassociation frame. The value of the notification includes the MAC address of the MAC to which the Disassociation frame was sent and the reason for the disassociation. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= { dot11SMTnotification 0 1 } dot11Deauthenticate NOTIFICATION-TYPE OBJECTS { ifIndex, dot11DeauthenticateReason, dot11DeauthenticateStation } STATUS current DESCRIPTION "The deauthenticate notification is sent when the STA sends a Deauthentication frame. The value of the notification includes the MAC address of the MAC to which the Deauthentication frame was sent and the reason for the deauthentication. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= { dot11SMTnotification 0 2 } dot11AuthenticateFail NOTIFICATION-TYPE OBJECTS { ifIndex, dot11AuthenticateFailStatus, dot11AuthenticateFailStation } STATUS current DESCRIPTION "The authenticate failure notification is sent when the STA sends an Authentication frame with a status code other than SUCCESS. The value of the notification includes the MAC address of the MAC to which the Authentication frame was sent and the reason for the authentication failure. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= { dot11SMTnotification 0 3 } dot11Associate NOTIFICATION-TYPE OBJECTS { ifIndex, dot11AssociateStation, dot11AssociateID} STATUS current DESCRIPTION "The associate notification is sent when the STA sends an Association Response frame with a status code equal to SUCCESS. The value of the notification includes the MAC address of the MAC to which the Association Response frame was sent and the Association ID. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= { dot11SMTnotification 0 4 } dot11AssociateFailed NOTIFICATION-TYPE OBJECTS { ifIndex, dot11AssociateFailStatus, dot11AssociateFailStation } STATUS current DESCRIPTION "The associate failed notification is sent when the STA sends an Association Response frame with a status code other than SUCCESS. The value of the notification includes the MAC address of the MAC to which the Association Response frame was sent and the reason for the association failure. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= { dot11SMTnotification 0 5 } dot11Reassociate NOTIFICATION-TYPE OBJECTS { ifIndex, dot11ReassociateStation, dot11ReassociateID} STATUS current DESCRIPTION "The reassociate notification is sent when the STA sends a Reassociation Response frame with a status code equal to SUCCESS. The value of the notification includes the MAC address of the MAC to which the Reassociation Response frame was sent and the Reassociation ID. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= { dot11SMTnotification 0 6 } dot11ReassociateFailed NOTIFICATION-TYPE OBJECTS { ifIndex, dot11ReassociateFailStatus, dot11ReassociateStation } STATUS current DESCRIPTION "The reassociate failed notification is sent when the STA sends a Reassociation Response frame with a status code other than SUCCESS. The value of the notification includes the MAC address of the MAC to which the Reassociation Response frame was sent and the reason for the reassociation failure. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." ::= { dot11SMTnotification 0 7 } -- ********************************************************************** -- * End of dot11SMTnotification Objects -- ********************************************************************** -- ********************************************************************** -- * dot11MultiDomainCapability TABLE -- ********************************************************************** dot11MultiDomainCapabilityTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11MultiDomainCapabilityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This (conceptual) table of attributes for cross-domain mobility." ::= { dot11smt 7 } dot11MultiDomainCapabilityEntry OBJECT-TYPE SYNTAX Dot11MultiDomainCapabilityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the Multiple Domain Capability Table. IfIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB are indexed by ifIndex." INDEX { ifIndex, dot11MultiDomainCapabilityIndex } ::= { dot11MultiDomainCapabilityTable 1 } Dot11MultiDomainCapabilityEntry ::= SEQUENCE { dot11MultiDomainCapabilityIndex Unsigned32, dot11FirstChannelNumber Unsigned32, dot11NumberofChannels Unsigned32, dot11MaximumTransmitPowerLevel Integer32 } dot11MultiDomainCapabilityIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the multidomain Capability Table." ::= { dot11MultiDomainCapabilityEntry 1 } dot11FirstChannelNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the value of the lowest channel number in the subband for the associated domain country string." DEFVAL { 0 } ::= { dot11MultiDomainCapabilityEntry 2 } dot11NumberofChannels OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the value of the total number of channels allowed in the subband for the associated domain country string." DEFVAL { 0 } ::= { dot11MultiDomainCapabilityEntry 3 } dot11MaximumTransmitPowerLevel OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum transmit power allowed in the subband for the associated domain country string." DEFVAL { 0 } ::= { dot11MultiDomainCapabilityEntry 4 } -- ******************************************************************** -- * End of dot11MultiDomainCapability TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11SpectrumManagement TABLE -- ******************************************************************** dot11SpectrumManagementTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11SpectrumManagementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "(Conceptual) table of attributes for spectrum management" ::= {dot11smt 8} dot11SpectrumManagementEntry OBJECT-TYPE SYNTAX Dot11SpectrumManagementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the Spectrum Management Table. IfIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB are indexed by ifIndex." INDEX {ifIndex, dot11SpectrumManagementIndex} ::= { dot11SpectrumManagementTable 1 } Dot11SpectrumManagementEntry ::= SEQUENCE { dot11SpectrumManagementIndex Unsigned32, dot11ChannelSwitchTime Unsigned32, dot11PowerCapabilityMaxImplemented Integer32, dot11PowerCapabilityMinImplemented Integer32 } dot11SpectrumManagementIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the Spectrum Management Table." ::= { dot11SpectrumManagementEntry 1 } -- value 2 is reserved dot11ChannelSwitchTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates assumed channel switch time. The minimum value of this attribute is 1 TU." DEFVAL { 2 } ::= { dot11SpectrumManagementEntry 3 } dot11PowerCapabilityMaxImplemented OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum transmit Power Capability of this station." ::= { dot11SpectrumManagementEntry 4 } dot11PowerCapabilityMinImplemented OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the minimum transmit Power Capability of this station." ::= { dot11SpectrumManagementEntry 5 } -- ****************************************************************** -- * End of dot11SpectrumManagement TABLE -- ****************************************************************** -- ******************************************************************** -- * dot11RSNAConfig TABLE (RSNA and TSN) -- ******************************************************************** dot11RSNAConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RSNAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table containing RSNA configuration objects." ::= { dot11smt 9 } dot11RSNAConfigEntry OBJECT-TYPE SYNTAX Dot11RSNAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11RSNAConfigTable." INDEX { ifIndex } ::= { dot11RSNAConfigTable 1 } Dot11RSNAConfigEntry ::= SEQUENCE { dot11RSNAConfigVersion Unsigned32, dot11RSNAConfigPairwiseKeysImplemented Unsigned32, dot11RSNAConfigGroupCipher OCTET STRING, dot11RSNAConfigGroupRekeyMethod INTEGER, dot11RSNAConfigGroupRekeyTime Unsigned32, dot11RSNAConfigGroupRekeyPackets Unsigned32, dot11RSNAConfigGroupRekeyStrict TruthValue, dot11RSNAConfigPSKValue OCTET STRING, dot11RSNAConfigPSKPassPhrase DisplayString, dot11RSNAConfigGroupUpdateCount Unsigned32, dot11RSNAConfigPairwiseUpdateCount Unsigned32, dot11RSNAConfigGroupCipherSize Unsigned32, dot11RSNAConfigPMKLifetime Unsigned32, dot11RSNAConfigPMKReauthThreshold Unsigned32, dot11RSNAConfigNumberOfPTKSAReplayCounters Unsigned32, dot11RSNAConfigSATimeout Unsigned32, dot11RSNAAuthenticationSuiteSelected OCTET STRING, dot11RSNAPairwiseCipherSelected OCTET STRING, dot11RSNAGroupCipherSelected OCTET STRING, dot11RSNAPMKIDUsed OCTET STRING, dot11RSNAAuthenticationSuiteRequested OCTET STRING, dot11RSNAPairwiseCipherRequested OCTET STRING, dot11RSNAGroupCipherRequested OCTET STRING, dot11RSNATKIPCounterMeasuresInvoked Unsigned32, dot11RSNA4WayHandshakeFailures Unsigned32, dot11RSNAConfigNumberOfGTKSAReplayCounters Unsigned32, dot11RSNAConfigSTKKeysImplemented Unsigned32, dot11RSNAConfigSTKCipher OCTET STRING, dot11RSNAConfigSTKRekeyTime Unsigned32, dot11RSNAConfigSMKUpdateCount Unsigned32, dot11RSNAConfigSTKCipherSize Unsigned32, dot11RSNAConfigSMKLifetime Unsigned32, dot11RSNAConfigSMKReauthThreshold Unsigned32, dot11RSNAConfigNumberOfSTKSAReplayCounters Unsigned32, dot11RSNAPairwiseSTKSelected OCTET STRING, dot11RSNASMKHandshakeFailures Unsigned32, dot11RSNASAERetransPeriod Unsigned32, dot11RSNASAEAntiCloggingThreshold Unsigned32, dot11RSNASAESync Unsigned32, dot11RSNAStatsGCMPReplays Unsigned32, dot11RSNAStatsRobustMgmtGCMPReplays Unsigned32 } -- dot11RSNAConfigEntry 1 has been deprecated. dot11RSNAConfigVersion OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The highest RSNA version this entity supports. See 9.4.2.8." ::= { dot11RSNAConfigEntry 2 } dot11RSNAConfigPairwiseKeysImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This object indicates how many pairwise keys the entity supports for RSNA." ::= { dot11RSNAConfigEntry 3 } dot11RSNAConfigGroupCipher OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object indicates the group cipher suite selector the entity uses. The group cipher suite in the RSNE takes its value from this variable. It consists of an OUI or CID (the first 3 octets) and a cipher suite identifier (the last octet)." ::= { dot11RSNAConfigEntry 4 } dot11RSNAConfigGroupRekeyMethod OBJECT-TYPE SYNTAX INTEGER { disabled(1), timeBased(2), packetBased(3), timepacketBased(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object selects a mechanism for rekeying the RSNA GTK. The default is time-based, once per day. Rekeying the GTK is applicable only to an entity acting in the Authenticator role." DEFVAL { timeBased } ::= { dot11RSNAConfigEntry 5 } dot11RSNAConfigGroupRekeyTime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The time after which the RSNA GTK is refreshed. The timer starts at the moment the GTK was set using the MLME-SETKEYS.request primitive." DEFVAL { 86400 } -- once per day ::= { dot11RSNAConfigEntry 6 } dot11RSNAConfigGroupRekeyPackets OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "1000 packets" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. A packet count after which the RSNA GTK is refreshed. The packet counter starts at the moment the GTK was set using the MLME-SETKEYS.request primitive and it counts all packets encrypted using the current GTK." ::= { dot11RSNAConfigEntry 7 } dot11RSNAConfigGroupRekeyStrict OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object signals that the GTK be refreshed whenever a STA leaves the BSS that possesses the GTK." ::= { dot11RSNAConfigEntry 8 } dot11RSNAConfigPSKValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The PSK for when RSNA in PSK mode is the selected AKM suite. In that case, the PMK obtains its value from this object. This object is logically write-only. Reading this variable returns unsuccessful status or null or 0." ::= { dot11RSNAConfigEntry 9 } dot11RSNAConfigPSKPassPhrase OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The PSK, for when RSNA in PSK mode is the selected AKM suite, is configured by dot11RSNAConfigPSKValue. An alternative manner of setting the PSK uses the password-to-key algorithm defined in J.4. This variable provides a means to enter a pass-phrase. When this object is written, the RSNA entity uses the password-to-key algorithm specified in J.4 to derive a preshared and populate dot11RSNAConfigPSKValue with this key. This object is logically write-only. Reading this variable returns unsuccessful status or null or 0." ::= { dot11RSNAConfigEntry 10 } -- dot11RSNAConfigEntry 11 and dot11RSNAConfigEntry 12 have been -- deprecated. dot11RSNAConfigGroupUpdateCount OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The number of times message 1 in the RSNA group key handshake is retried per GTK handshake attempt." DEFVAL { 3 } ::= { dot11RSNAConfigEntry 13 } dot11RSNAConfigPairwiseUpdateCount OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The number of times message 1 and message 3 in the RSNA 4-way handshake are retried per 4-way handshake attempt." DEFVAL { 3 } ::= { dot11RSNAConfigEntry 14 } dot11RSNAConfigGroupCipherSize OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) UNITS "bits" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object indicates the length of the group cipher key." ::= { dot11RSNAConfigEntry 15 } dot11RSNAConfigPMKLifetime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The maximum lifetime of a PMK in the PMKSA cache." DEFVAL { 43200 } ::= { dot11RSNAConfigEntry 16 } dot11RSNAConfigPMKReauthThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..100) UNITS "percentage" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The percentage of the PMK lifetime that should expire before an IEEE 802.1X reauthentication occurs." DEFVAL { 70 } ::= { dot11RSNAConfigEntry 17 } dot11RSNAConfigNumberOfPTKSAReplayCounters OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Specifies the number of PTKSA replay counters per association: 0 -> 1 replay counter, 1 -> 2 replay counters, 2 -> 4 replay counters, 3 -> 16 replay counters" ::= { dot11RSNAConfigEntry 18 } dot11RSNAConfigSATimeout OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The maximum time a security association takes to set up." DEFVAL { 60 } ::= { dot11RSNAConfigEntry 19 } dot11RSNAAuthenticationSuiteSelected OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME when a security association is established. The selector of the last AKM suite negotiated." ::= { dot11RSNAConfigEntry 20 } dot11RSNAPairwiseCipherSelected OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME when a security association is established. The selector of the last pairwise cipher negotiated." ::= { dot11RSNAConfigEntry 21 } dot11RSNAGroupCipherSelected OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME when a security association is established. The selector of the last group cipher negotiated." ::= { dot11RSNAConfigEntry 22 } dot11RSNAPMKIDUsed OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME when a security association is established. The selector of the last PMKID used in the last 4-way handshake." ::= { dot11RSNAConfigEntry 23 } dot11RSNAAuthenticationSuiteRequested OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME when a security association is established. The selector of the last AKM suite requested." ::= { dot11RSNAConfigEntry 24 } dot11RSNAPairwiseCipherRequested OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME when a security association is established. The selector of the last pairwise cipher requested." ::= { dot11RSNAConfigEntry 25 } dot11RSNAGroupCipherRequested OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME when a security association is established. The selector of the last group cipher requested." ::= { dot11RSNAConfigEntry 26 } dot11RSNATKIPCounterMeasuresInvoked OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. Counts the number of times that a TKIP MIC failure occurred two times within 60 s and TKIP countermeasures were invoked. This attribute counts both local and remote MIC failure events reported to this STA. It increments every time TKIP countermeasures are invoked" ::= { dot11RSNAConfigEntry 27 } dot11RSNA4WayHandshakeFailures OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME when the condition described below occurs. Counts the number of 4-way handshake failures." ::= { dot11RSNAConfigEntry 28 } dot11RSNAConfigNumberOfGTKSAReplayCounters OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Specifies the number of GTKSA replay counters per association: 0 -> 1 replay counter, 1 -> 2 replay counters, 2 -> 4 replay counters, 3 -> 16 replay counters" ::= { dot11RSNAConfigEntry 29 } dot11RSNAConfigSTKKeysImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a capability variable. Its value is determined by device capabilities. This object indicates how many STKs the entity supports for RSNA." ::= { dot11RSNAConfigEntry 30 } dot11RSNAConfigSTKCipher OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object specifies the ciphersuite used by the STK for a DLS link." ::= { dot11RSNAConfigEntry 31} dot11RSNAConfigSTKRekeyTime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "seconds" MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The time after which an RSNA STK is refreshed. The timer starts at the moment the STK was set using the MLME-SETKEYS.request primitive." DEFVAL { 86400 } -- once per day ::= { dot11RSNAConfigEntry 32 } dot11RSNAConfigSMKUpdateCount OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The number of times message 1 in the RSNA SMK handshake is retried per SMK handshake attempt." DEFVAL { 3 } ::= { dot11RSNAConfigEntry 33 } dot11RSNAConfigSTKCipherSize OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) UNITS "bits" MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object indicates the length of the STK cipher key." ::= { dot11RSNAConfigEntry 34 } dot11RSNAConfigSMKLifetime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "seconds" MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated because mechanisms for use of cached SMKSAs are not defined. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The maximum lifetime of an SMK in the SMKSA cache." DEFVAL { 43200 } ::= { dot11RSNAConfigEntry 35 } dot11RSNAConfigSMKReauthThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated because mechanisms for use of cached SMKSAs are not defined. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the number of seconds for which an SMK authentication is valid. If a new SMK authentication is not completed successfully before the number of seconds indicated by this attribute elapse, from the prior authentication, the STA deletes the SMKSA." ::= { dot11RSNAConfigEntry 36 } dot11RSNAConfigNumberOfSTKSAReplayCounters OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a capability variable. Its value is determined by device capabilities. Specifies the number of STKSA replay counters per association: 0 -> 1 replay counter, 1 -> 2 replay counters, 2 -> 4 replay counters, 3 -> 16 replay counters" ::= { dot11RSNAConfigEntry 37 } dot11RSNAPairwiseSTKSelected OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the RSNA Key Management entity in the SME when a security association is established. The selector of the last STK cipher negotiated." ::= { dot11RSNAConfigEntry 38 } dot11RSNASMKHandshakeFailures OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the RSNA Key Management entity in the SME when the condition described below occurs. Counts the number of SMK handshake failures." ::= { dot11RSNAConfigEntry 39 } dot11RSNASAERetransPeriod OBJECT-TYPE SYNTAX Unsigned32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when establishing or becoming a member of a BSS. Changes take effect for the next MLME-START.request or MLME-JOIN.request primitive. This object specifies the initial retry timeout used by the SAE authentication and key establishment protocol." DEFVAL { 2000 } ::= { dot11RSNAConfigEntry 40 } dot11RSNASAEAntiCloggingThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This object specifies the maximum number of SAE protocol instances allowed to simultaneously be in either Committed or Confirmed state." ::= { dot11RSNAConfigEntry 41 } dot11RSNASAESync OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This object specifies the maximum number of synchronization errors that are allowed to happen prior to disassociation of the offending SAE peer." ::= { dot11RSNAConfigEntry 42 } -- ******************************************************************** -- * End of dot11RSNAConfig TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11RSNAConfigPairwiseCiphers TABLE -- ******************************************************************** dot11RSNAConfigPairwiseCiphersTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RSNAConfigPairwiseCiphersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table lists the pairwise ciphers supported by this entity. It allows enabling and disabling of each pairwise cipher by network management. The pairwise cipher suite list in the RSNE is formed using the information in this table." ::= { dot11smt 10 } dot11RSNAConfigPairwiseCiphersEntry OBJECT-TYPE SYNTAX Dot11RSNAConfigPairwiseCiphersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table entry, indexed by the interface index (or all interfaces) and the pairwise cipher." INDEX { ifIndex, dot11RSNAConfigPairwiseCipherIndex } ::= { dot11RSNAConfigPairwiseCiphersTable 1 } Dot11RSNAConfigPairwiseCiphersEntry ::= SEQUENCE { dot11RSNAConfigPairwiseCipherIndex Unsigned32, dot11RSNAConfigPairwiseCipherImplemented OCTET STRING, dot11RSNAConfigPairwiseCipherActivated TruthValue, dot11RSNAConfigPairwiseCipherSizeImplemented Unsigned32 } dot11RSNAConfigPairwiseCipherIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary index into the dot11RSNAConfigPairwiseCiphersTable." ::= { dot11RSNAConfigPairwiseCiphersEntry 1 } dot11RSNAConfigPairwiseCipherImplemented OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The selector of a supported pairwise cipher. It consists of an OUI or CID (the first 3 octets) and a cipher suite identifier (the last octet)." ::= { dot11RSNAConfigPairwiseCiphersEntry 2 } dot11RSNAConfigPairwiseCipherActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object enables or disables the pairwise cipher." ::= { dot11RSNAConfigPairwiseCiphersEntry 3 } dot11RSNAConfigPairwiseCipherSizeImplemented OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) UNITS "bits" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This object indicates the length of the pairwise cipher key. This should be 256 for TKIP and 128 or 256 for CCMP and 128 or 256 for GCMP." ::= { dot11RSNAConfigPairwiseCiphersEntry 4 } -- ******************************************************************** -- * End of dot11RSNAConfigPairwiseCiphers TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11RSNAConfigAuthenticationSuites TABLE -- ******************************************************************** dot11RSNAConfigAuthenticationSuitesTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RSNAConfigAuthenticationSuitesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table lists the AKM suites supported by this entity. Each AKM suite can be individually enabled and disabled. The AKM suite list in the RSNE is formed using the information in this table." ::= { dot11smt 11 } dot11RSNAConfigAuthenticationSuitesEntry OBJECT-TYPE SYNTAX Dot11RSNAConfigAuthenticationSuitesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (row) in the dot11RSNAConfigAuthenticationSuitesTable." INDEX { dot11RSNAConfigAuthenticationSuiteIndex } ::= { dot11RSNAConfigAuthenticationSuitesTable 1 } Dot11RSNAConfigAuthenticationSuitesEntry ::= SEQUENCE { dot11RSNAConfigAuthenticationSuiteIndex Unsigned32, dot11RSNAConfigAuthenticationSuiteImplemented OCTET STRING, dot11RSNAConfigAuthenticationSuiteActivated TruthValue } dot11RSNAConfigAuthenticationSuiteIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used as an index into the dot11RSNAConfigAuthenticationSuitesTable." ::= { dot11RSNAConfigAuthenticationSuitesEntry 1 } dot11RSNAConfigAuthenticationSuiteImplemented OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The selector of an AKM suite. It consists of an OUI or CID (the first 3 octets) and a cipher suite identifier (the last octet)." ::= { dot11RSNAConfigAuthenticationSuitesEntry 2 } dot11RSNAConfigAuthenticationSuiteActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable indicates whether the corresponding AKM suite is enabled/disabled." ::= { dot11RSNAConfigAuthenticationSuitesEntry 3 } -- ******************************************************************** -- * End of dot11RSNAConfigAuthenticationSuites TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11RSNAStats TABLE -- ******************************************************************** dot11RSNAStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RSNAStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains per-STA statistics in an RSN. The entry with dot11RSNAStatsSTAAddress equal to FF-FF-FF-FF-FF-FF contains statistics for group addressed traffic." ::= { dot11smt 12 } dot11RSNAStatsEntry OBJECT-TYPE SYNTAX Dot11RSNAStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11RSNAStatsTable." INDEX { ifIndex, dot11RSNAStatsIndex } ::= { dot11RSNAStatsTable 1 } Dot11RSNAStatsEntry ::= SEQUENCE { dot11RSNAStatsIndex Unsigned32, dot11RSNAStatsSTAAddress MacAddress, dot11RSNAStatsVersion Unsigned32, dot11RSNAStatsSelectedPairwiseCipher OCTET STRING, dot11RSNAStatsTKIPICVErrors Counter32, dot11RSNAStatsTKIPLocalMICFailures Counter32, dot11RSNAStatsTKIPRemoteMICFailures Counter32, dot11RSNAStatsCCMPReplays Counter32, dot11RSNAStatsCCMPDecryptErrors Counter32, dot11RSNAStatsTKIPReplays Counter32, dot11RSNAStatsCMACReplays Counter32, dot11RSNAStatsRobustMgmtCCMPReplays Counter32, dot11RSNAStatsBIPMICErrors Counter32 } dot11RSNAStatsIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An auxiliary index into the dot11RSNAStatsTable." ::= { dot11RSNAStatsEntry 1 } dot11RSNAStatsSTAAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME. The MAC address of the STA to which the statistics in this conceptual row belong." ::= { dot11RSNAStatsEntry 2 } dot11RSNAStatsVersion OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME. The RSNA version with which the STA associated." ::= { dot11RSNAStatsEntry 3 } dot11RSNAStatsSelectedPairwiseCipher OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the RSNA Key Management entity in the SME. The pairwise cipher suite Selector (as defined in 9.4.2.24.2) used during association, in transmission order." ::= { dot11RSNAStatsEntry 4 } dot11RSNAStatsTKIPICVErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. Counts the number of TKIP ICV errors encountered when decrypting packets for the STA." ::= { dot11RSNAStatsEntry 5 } dot11RSNAStatsTKIPLocalMICFailures OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. Counts the number of MIC failures encountered when checking the integrity of packets received from the STA at this entity." ::= { dot11RSNAStatsEntry 6 } dot11RSNAStatsTKIPRemoteMICFailures OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. Counts the number of MIC failures encountered by the STA identified by dot11StatsSTAAddress and reported back to this entity." ::= { dot11RSNAStatsEntry 7 } dot11RSNAStatsCCMPReplays OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. The number of received CCMP MPDUs discarded by the replay mechanism." ::= { dot11RSNAStatsEntry 8 } dot11RSNAStatsCCMPDecryptErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. The number of received MPDUs discarded by the CCMP decryption algorithm." ::= { dot11RSNAStatsEntry 9 } dot11RSNAStatsTKIPReplays OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. Counts the number of TKIP replay errors detected." ::= { dot11RSNAStatsEntry 10 } dot11RSNAStatsCMACReplays OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. The number of received MPDUs discarded by the CMAC replay errors." ::= { dot11RSNAStatsEntry 12 } dot11RSNAStatsRobustMgmtCCMPReplays OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. The number of received robust Management frames discarded due to CCMP replay errors" ::= {dot11RSNAStatsEntry 13} dot11RSNAStatsBIPMICErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. The number of received MMPDUs discarded due to BIP MIC errors" ::= {dot11RSNAStatsEntry 14} -- ******************************************************************** -- * End of dot11RSNAStats TABLE -- ******************************************************************** -- ********************************************************************** -- * dot11OperatingClasses TABLE -- ********************************************************************** dot11OperatingClassesTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11OperatingClassesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "(Conceptual) table of attributes for operating classes" ::= {dot11smt 13} dot11OperatingClassesEntry OBJECT-TYPE SYNTAX Dot11OperatingClassesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the Operating Classes Table. IfIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB are indexed by ifIndex." INDEX {ifIndex, dot11OperatingClassesIndex} ::= { dot11OperatingClassesTable 1 } Dot11OperatingClassesEntry ::= SEQUENCE { dot11OperatingClassesIndex Unsigned32, dot11OperatingClass Unsigned32, dot11CoverageClass Unsigned32 } dot11OperatingClassesIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the Operating Classes Table." ::= { dot11OperatingClassesEntry 1 } dot11OperatingClass OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity when the device is initialized. This attribute indicates the operating class to be used." DEFVAL { 0 } ::= { dot11OperatingClassesEntry 2 } dot11CoverageClass OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity when the device is initialized. This attribute indicates the coverage class to be used." DEFVAL { 0 } ::= { dot11OperatingClassesEntry 3 } -- ******************************************************************** -- * End of dot11OperatingClasses TABLE -- ******************************************************************** -- ********************************************************************** -- * dot11BeaconRssi TABLE -- ********************************************************************** dot11BeaconRssiTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11BeaconRssiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "(Conceptual) table of attributes for received Beacon RSSI." ::= {dot11smt 38} dot11BeaconRssiEntry OBJECT-TYPE SYNTAX Dot11BeaconRssiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the received Beacon RSSI table." INDEX { dot11BeaconRssiIndex } ::= { dot11BeaconRssiTable 1 } Dot11BeaconRssiEntry ::= SEQUENCE { dot11BeaconRssiIndex Unsigned32, dot11BeaconMACAddress MacAddress, dot11BeaconRssi Integer32} dot11BeaconRssiIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the received Beacon Rssi table." ::= { dot11BeaconRssiEntry 1 } dot11BeaconMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving a Beacon frame. This attribute indicates the MAC address of the AP from which the beacon used for Beacon RSSI measurement was transmitted." ::= { dot11BeaconRssiEntry 2 } dot11BeaconRssi OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving a Beacon frame. This attribute indicates the received signal strength of Beacon frames received on the channel, averaged (in linear domain) over all active receive chains. This may be time-averaged over recent history by a vendor-specific smoothing function." ::= { dot11BeaconRssiEntry 3 } -- ******************************************************************** -- * End of dot11BeaconRssi TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11FastBSSTransitionConfig TABLE -- ******************************************************************** dot11FastBSSTransitionConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11FastBSSTransitionConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table containing fast BSS transition configuration objects." ::= { dot11smt 15 } dot11FastBSSTransitionConfigEntry OBJECT-TYPE SYNTAX Dot11FastBSSTransitionConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11FastBSSTransitionConfigTable." INDEX { ifIndex } ::= { dot11FastBSSTransitionConfigTable 1 } Dot11FastBSSTransitionConfigEntry ::= SEQUENCE { dot11FastBSSTransitionActivated TruthValue, dot11FTMobilityDomainID OCTET STRING, dot11FTOverDSActivated TruthValue, dot11FTResourceRequestSupported TruthValue, dot11FTR0KeyHolderID OCTET STRING, dot11FTR0KeyLifetime Unsigned32, dot11FTR1KeyHolderID OCTET STRING, dot11FTReassociationDeadline Unsigned32 } dot11FastBSSTransitionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. When this object is true, this indicates that fast BSS transition (FT) is enabled on this entity. The entity advertises the FT-related elements in its Beacon and Probe Response frames. This object requires that dot11FastBSSTransitionImplemented also be equal to true." ::= { dot11FastBSSTransitionConfigEntry 1 } dot11FTMobilityDomainID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the Mobility Domain identifier (MDID) of this entity. The MDID is used to indicate a group of APs, within an ESS, between which a STA can use fast BSS transition services. Fast BSS transitions are allowed only between APs that have the same MDID and are within the same ESS. They are not allowed between APs with different MDIDs or in different ESSs. Since fast BSS transition services are defined only within the scope of an ESS, there is no requirement that MDIDs be unique across ESSs." ::= { dot11FastBSSTransitionConfigEntry 2 } dot11FTOverDSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. When this object is true, this indicates that fast BSS transition via the over-the-DS protocol as described in Clause 13 is enabled on this AP entity." ::= { dot11FastBSSTransitionConfigEntry 3 } dot11FTResourceRequestSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. When this object is true, this indicates that the fast BSS transition (FT) resource request procedures of 13.10 are supported on this AP entity." ::= { dot11FastBSSTransitionConfigEntry 4 } dot11FTR0KeyHolderID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..48)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the PMK-R0 key holder identifier (R0KH-ID) of the Authenticator of this AP. NOTE: Backend protocol might allow longer NAS Client identifiers (e.g., RADIUS allows up to 253-octet NAS-Identifier), but if used with fast BSS transition, the maximum length is limited to 48 octets. Subclause 13.2.2 requires that the same value is used for the NAS Client identifier and dot11FTR0KeyHolderID." ::= { dot11FastBSSTransitionConfigEntry 5 } dot11FTR0KeyLifetime OBJECT-TYPE SYNTAX Unsigned32 (60..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the default lifetime of the PMK-R0, in seconds, when a Session-Timeout attribute is not provided during the EAP authentication. This attribute also applies when the PMK-R0 is derived from a PSK." DEFVAL { 1209600 } ::= { dot11FastBSSTransitionConfigEntry 6 } dot11FTR1KeyHolderID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the PMK-R1 key holder identifier (R1KH-ID) of the Authenticator of this AP. It is equal to a MAC address of the entity holding the PMK-R1 in the Authenticator." ::= { dot11FastBSSTransitionConfigEntry 7 } dot11FTReassociationDeadline OBJECT-TYPE SYNTAX Unsigned32 (1000..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of TUs that this target AP entity caches a PTKSA and reserves any specified resources for a STA while waiting for a reassociation from that STA. It is assumed that this value is administered consistently across the mobility domain." DEFVAL { 1000 } ::= { dot11FastBSSTransitionConfigEntry 8 } -- ********************************************************************* -- * End of dot11FastBSSTransitionConfig TABLE -- ********************************************************************* -- ******************************************************************** -- * dot11LCIDSE TABLE -- ******************************************************************** dot11LCIDSETable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11LCIDSEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains conceptual table of attributes for Dependent Station Enablement." ::= { dot11smt 16 } dot11LCIDSEEntry OBJECT-TYPE SYNTAX Dot11LCIDSEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11LCIDSETable Indexed by dot11LCIDSEIndex." INDEX { dot11LCIDSEIndex } ::= { dot11LCIDSETable 1 } Dot11LCIDSEEntry ::= SEQUENCE { dot11LCIDSEIndex Unsigned32, dot11LCIDSEIfIndex InterfaceIndex, dot11LCIDSECurrentOperatingClass Unsigned32, dot11LCIDSELatitudeUncertainty Unsigned32, dot11LCIDSELatitudeInteger Integer32, dot11LCIDSELatitudeFraction Integer32, dot11LCIDSELongitudeUncertainty Unsigned32, dot11LCIDSELongitudeInteger Integer32, dot11LCIDSELongitudeFraction Integer32, dot11LCIDSEAltitudeType INTEGER, dot11LCIDSEAltitudeUncertainty Unsigned32, dot11LCIDSEAltitude Integer32, dot11LCIDSEDatum Unsigned32, dot11RegLocAgreement TruthValue, dot11RegLocDSE TruthValue, dot11DependentSTA TruthValue, dot11DependentEnablementIdentifier Unsigned32, dot11DSEEnablementTimeLimit Unsigned32, dot11DSEEnablementFailHoldTime Unsigned32, dot11DSERenewalTime Unsigned32, dot11DSETransmitDivisor Unsigned32 } dot11LCIDSEIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for LCI DSE elements in dot11LCIDSETable, greater than 0." ::= { dot11LCIDSEEntry 1 } dot11LCIDSEIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Each IEEE 802.11 interface is represented by an ifEntry. Interface Tables in this MIB are indexed by ifIndex." ::= { dot11LCIDSEEntry 2 } dot11LCIDSECurrentOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Current Operating Class is 8 bits indicating the particular Operating Class in use by the radio." ::= { dot11LCIDSEEntry 3 } dot11LCIDSELatitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Latitude uncertainty is defined in IETF RFC 6225." ::= { dot11LCIDSEEntry 4 } dot11LCIDSELatitudeInteger OBJECT-TYPE SYNTAX Integer32 (-359..359) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Latitude is represented as a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of the latitude." ::= { dot11LCIDSEEntry 5 } dot11LCIDSELatitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Latitude is represented a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of the latitude." ::= { dot11LCIDSEEntry 6 } dot11LCIDSELongitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Longitude uncertainty is defined in IETF RFC 6225." ::= { dot11LCIDSEEntry 7 } dot11LCIDSELongitudeInteger OBJECT-TYPE SYNTAX Integer32 (-359..359) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Longitude is represented a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of the longitude." ::= { dot11LCIDSEEntry 8 } dot11LCIDSELongitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Longitude is represented a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of the longitude." ::= { dot11LCIDSEEntry 9 } dot11LCIDSEAltitudeType OBJECT-TYPE SYNTAX INTEGER { meters(1), floors(2), hagm(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Altitude Type is 4 bits encoding the type of altitude. Codes defined are: meters : in 2s complement fixed-point 22-bit integer part with 8-bit fraction floors : in 2s complement fixed-point 22-bit integer part with 8-bit fraction hagm : Height Above Ground in meters, in 2s complement fixed-point 22-bit integer part with 8-bit fraction. " DEFVAL { 3 } ::= { dot11LCIDSEEntry 10 } dot11LCIDSEAltitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Altitude resolution is 6 bits indicating the number of valid bits in the altitude." ::= { dot11LCIDSEEntry 11 } dot11LCIDSEAltitude OBJECT-TYPE SYNTAX Integer32 (-536870912..536870911) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Altitude is a 30-bit value defined by the Altitude type field. The field is encoded as a 2s complement fixed-point 22-bit integer part with 8-bit fraction." ::= { dot11LCIDSEEntry 12 } -- reserved: 13. was dot11LCIDSEAltitudeFraction dot11LCIDSEDatum OBJECT-TYPE SYNTAX Unsigned32 (1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. Datum is a 3-bit value encoding the horizontal and vertical references used for the coordinates given in this LCI. IETF RFC 6225 defines the values of Datum. Type 1 is WGS-84, the coordinate system used by GPS. Type 2 is NAD83 with NAVD88 vertical reference. Type 3 is NAD83 with Mean Lower Low Water vertical datum. All other types are reserved." DEFVAL { 1 } ::= { dot11LCIDSEEntry 14 } dot11RegLocAgreement OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a DSE Enablement frame is received. RegLocAgreement reports the Enabling STA's Agreement status. false indicates it is operating away from national borders and outside national policy zones. true indicates it is operating by agreement near national borders or inside national policy zones." DEFVAL { false } ::= { dot11LCIDSEEntry 15 } dot11RegLocDSE OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a DSE Enablement frame is received. RegLocDSE reports the Enabling STA's DSE status. false indicates Dependent STAs are not enabled. true indicates Dependent STA operation is enabled." DEFVAL { false } ::= { dot11LCIDSEEntry 16 } dot11DependentSTA OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a DSE Enablement frame is received. This attribute reports the Dependent STA status of the STA that sent the Beacon or Probe Response frame(s) with this information. false indicates that STA is not operating as a Dependent STA. true indicates that STA is operating as a Dependent STA." DEFVAL { true } ::= { dot11LCIDSEEntry 17 } dot11DependentEnablementIdentifier OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a DSE Enablement frame is received. This attribute reports the Dependent STA identifier assigned by the enabling STA to the dependent station." DEFVAL { 0 } ::= { dot11LCIDSEEntry 18 } dot11DSEEnablementTimeLimit OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. dot11DSEEnablementTimeLimit indicates the maximum number of seconds that a dependent STA may transmit in a DSE frequency band while attaining enablement with an enabling STA. Unless another value is mandated by regulatory authorities, the value is 32 seconds." DEFVAL { 32 } ::= { dot11LCIDSEEntry 19 } dot11DSEEnablementFailHoldTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. dot11DSEEnablementFailHoldTime indicates the number of seconds that a dependent STA must not transmit in a DSE frequency band when it fails to attain enablement with an enabling STA within dot11DSEEnablementTimeLimit seconds. Unless another value is mandated by regulatory authorities, the value is 512 seconds." DEFVAL { 512 } ::= { dot11LCIDSEEntry 20} dot11DSERenewalTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. dot11DSERenewalTime indicates the maximum number of seconds that a dependent STA may operate in a DSE frequency band without receiving and decoding an enabling signal from its enabling STA. Unless another value is mandated by regulatory authorities, the value is 60 seconds." DEFVAL { 60 } ::= { dot11LCIDSEEntry 21} dot11DSETransmitDivisor OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. dot11DSETransmitDivisor indicates the value used by a dependent STA when operating in a DSE frequency band and transmitting. The dependent STA sends an Action frame when the sum of dot11TransmittedFragmentCount, dot11GroupTransmittedFrameCount and dot11ReceivedFragmentCount modulo dot11DSETransmitDivisor equals 0." DEFVAL { 256 } ::= { dot11LCIDSEEntry 22} -- ******************************************************************** -- * End of dot11LCIDSE TABLE -- ******************************************************************** -- ********************************************************************** -- * dot11HTStationConfig TABLE -- ********************************************************************** dot11HTStationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11HTStationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Station Configuration attributes. In tabular form to allow for multiple instances on an agent." ::= { dot11smt 17 } dot11HTStationConfigEntry OBJECT-TYPE SYNTAX Dot11HTStationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the dot11HTStationConfig Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11HTStationConfigTable 1 } Dot11HTStationConfigEntry ::= SEQUENCE { dot11HTOperationalMCSSet OCTET STRING, dot11MIMOPowerSave INTEGER, dot11NDelayedBlockAckOptionImplemented TruthValue, dot11MaxAMSDULength INTEGER, dot11STBCControlFrameOptionImplemented TruthValue, dot11LsigTxopProtectionOptionImplemented TruthValue, dot11MaxRxAMPDUFactor Unsigned32, dot11MinimumMPDUStartSpacing Unsigned32, dot11PCOOptionImplemented TruthValue, dot11TransitionTime Unsigned32, dot11MCSFeedbackOptionImplemented INTEGER, dot11HTControlFieldSupported TruthValue, dot11RDResponderOptionImplemented TruthValue, dot11SPPAMSDUCapable TruthValue, dot11SPPAMSDURequired TruthValue, dot11FortyMHzOptionImplemented TruthValue } dot11HTOperationalMCSSet OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..127)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute shall specify the set of MCS at which the station may transmit data. Each octet contains a value representing a rate. Each MCS shall be within the range 1 to 127, and shall be supported for receiving data. This value is reported in transmitted Beacon, Probe Request, Probe Response, Association Request, Association Response, Reassociation Request, and Reassociation Response frames, and is used to determine whether a BSS with which the station might synchronize is suitable. It is also used when starting a BSS, as specified in 11.3." ::= { dot11HTStationConfigEntry 1 } dot11MIMOPowerSave OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2), mimo(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY when the power save condition changes. This is an 8-bit integer value that identifies the configured power save state of MIMO." ::= { dot11HTStationConfigEntry 2 } dot11NDelayedBlockAckOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting the No Acknowledgment option of the delayed block ack." ::= { dot11HTStationConfigEntry 3 } dot11MaxAMSDULength OBJECT-TYPE SYNTAX INTEGER { short(3839), long(7935) } UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum supported size of an A-MSDU." ::= { dot11HTStationConfigEntry 4 } dot11STBCControlFrameOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of processing the received Control frames that are STBC frames." ::= { dot11HTStationConfigEntry 5 } dot11LsigTxopProtectionOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting L-SIG TXOP protection option." ::= { dot11HTStationConfigEntry 6 } dot11MaxRxAMPDUFactor OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum length of A-MPDU that the STA can receive. The Maximum Rx A-MPDU defined by this field is equal to 2 ^ (13+dot11MaxRxAMPDUFactor) -1 octets." ::= { dot11HTStationConfigEntry 7 } dot11MinimumMPDUStartSpacing OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the minimum time between the start of adjacent MPDUs within an A-MPDU. This time is measured at the PHY SAP; the number of octets between the start of two consecutive MPDUs in A-MPDU shall be equal or greater than (dot11MinimumMPDUStartSpacing*PHY-bit-rate)/8. The encoding of the minimum time to this attribute is: 0 - no restriction 1 - 1/4 microsecond 2 - 1/2 microsecond 3 - 1 microsecond 4 - 2 microseconds 5 - 4 microseconds 6 - 8 microseconds 7 - 16 microseconds" ::= { dot11HTStationConfigEntry 8 } dot11PCOOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting PCO." ::= { dot11HTStationConfigEntry 9 } dot11TransitionTime OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates that the maximum transition time within which the STA can switch between 20 MHz channel width and 40 MHz channel width with a high probability. The encoding of the transition time to this attribute is: 0 - no transition 1 - 400 microseconds 2 - 1500 microseconds 3 - 5000 microseconds" ::= { dot11HTStationConfigEntry 10 } dot11MCSFeedbackOptionImplemented OBJECT-TYPE SYNTAX INTEGER { none(0), unsolicited (2), both (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the MCS feed back capability supported by the station implementation." ::= { dot11HTStationConfigEntry 11 } dot11HTControlFieldSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of receiving HT Control field." ::= { dot11HTStationConfigEntry 12 } dot11RDResponderOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable operating as an RD responder." ::= { dot11HTStationConfigEntry 13 } dot11SPPAMSDUCapable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of protecting the A-MSDU bit (Bit 7) in the QoS Control field when dot11RSNAActivated is true." ::= { dot11HTStationConfigEntry 14 } dot11SPPAMSDURequired OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the STA is configured to disallow (i.e., not to send or receive) PP A-MSDUs when dot11RSNAActivated is true." DEFVAL { false } ::= { dot11HTStationConfigEntry 15 } dot11FortyMHzOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA is capable of transmitting and receiving on a 40 MHz channel using a 40 MHz mask." ::= { dot11HTStationConfigEntry 16 } -- ********************************************************************** -- * End of dot11HTStationConfig TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11WirelessMgmtOptions TABLE -- ********************************************************************** dot11WirelessMgmtOptionsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WirelessMgmtOptionsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Wireless Management attributes. In tabular form to allow for multiple instances on an agent. This table only applies to the interface if dot11WirelessManagementImplemented is equal to true in the dot11StationConfigTable." ::= { dot11smt 18 } dot11WirelessMgmtOptionsEntry OBJECT-TYPE SYNTAX Dot11WirelessMgmtOptionsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WirelessMgmtOptionsTable. For all Wireless Management features, an Activated MIB attribute is used to activate/enable or deactivate/disable the corresponding feature. An Implemented MIB attribute is used for an optional feature to indicate whether the feature is implemented. A mandatory feature does not have a corresponding Implemented MIB attribute. It is possible for there to be multiple IEEE 802.11 interfaces on one agent, each with its unique MAC address. The relationship between an IEEE 802.11 interface and an interface in the context of the Internet-standard MIB is one-to-one. As such, the value of an ifIndex object instance can be directly used to identify corresponding instances of the objects defined herein. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11WirelessMgmtOptionsTable 1 } Dot11WirelessMgmtOptionsEntry ::= SEQUENCE { dot11LocationActivated TruthValue, dot11FMSImplemented TruthValue, dot11FMSActivated TruthValue, dot11EventsActivated TruthValue, dot11DiagnosticsActivated TruthValue, dot11MultiBSSIDImplemented TruthValue, dot11MultiBSSIDActivated TruthValue, dot11TFSImplemented TruthValue, dot11TFSActivated TruthValue, dot11WNMSleepModeImplemented TruthValue, dot11WNMSleepModeActivated TruthValue, dot11TIMBroadcastImplemented TruthValue, dot11TIMBroadcastActivated TruthValue, dot11ProxyARPImplemented TruthValue, dot11ProxyARPActivated TruthValue, dot11BSSTransitionActivated TruthValue, dot11QoSTrafficCapabilityImplemented TruthValue, dot11QoSTrafficCapabilityActivated TruthValue, dot11ACStationCountImplemented TruthValue, dot11ACStationCountActivated TruthValue, dot11CoLocIntfReportingImplemented TruthValue, dot11CoLocIntfReportingActivated TruthValue, dot11MotionDetectionImplemented TruthValue, dot11MotionDetectionActivated TruthValue, dot11TODImplemented TruthValue, dot11TODActivated TruthValue, dot11TimingMsmtImplemented TruthValue, dot11TimingMsmtActivated TruthValue, dot11ChannelUsageImplemented TruthValue, dot11ChannelUsageActivated TruthValue, dot11TriggerSTAStatisticsActivated TruthValue, dot11SSIDListImplemented TruthValue, dot11SSIDListActivated TruthValue, dot11MulticastDiagnosticsActivated TruthValue, dot11LocationTrackingImplemented TruthValue, dot11LocationTrackingActivated TruthValue, dot11DMSImplemented TruthValue, dot11DMSActivated TruthValue, dot11UAPSDCoexistenceImplemented TruthValue, dot11UAPSDCoexistenceActivated TruthValue, dot11WNMNotificationImplemented TruthValue, dot11WNMNotificationActivated TruthValue, dot11UTCTSFOffsetImplemented TruthValue, dot11UTCTSFOffsetActivated TruthValue, dot11FineTimingMsmtRespActivated TruthValue, dot11FineTimingMsmtInitActivated TruthValue, dot11LciCivicInNeighborReport TruthValue, dot11RMFineTimingMsmtRangeRepImplemented TruthValue, dot11RMFineTimingMsmtRangeRepActivated TruthValue, dot11RMLCIConfigured TruthValue, dot11RMCivicConfigured TruthValue } dot11LocationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide location is enabled. The capability is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 1 } dot11FMSImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting FMS when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 2 } dot11FMSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide FMS is enabled. The capability is disabled, otherwise" DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 3 } dot11EventsActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide Event Reporting is enabled. The capability is disabled, otherwise" DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 4 } dot11DiagnosticsActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide Diagnostic Reporting is enabled. The capability is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 5 } dot11MultiBSSIDImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting Multiple BSSID when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 6 } dot11MultiBSSIDActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as dot11MultiBSSIDActivated has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide Multi BSSID is enabled. The capability is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 7 } dot11TFSImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting TFS when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 8 } dot11TFSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that TFS is enabled. TFS is disabled otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 9 } dot11WNMSleepModeImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting WNM sleep mode when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 10 } dot11WNMSleepModeActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that WNM sleep mode is enabled. WNM sleep mode is disabled otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 11 } dot11TIMBroadcastImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting TIM Broadcast when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 12} dot11TIMBroadcastActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that TIM broadcast is enabled. TIM broadcast is disabled otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 13} dot11ProxyARPImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting the proxy ARP service, when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 14 } dot11ProxyARPActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the AP to provide the proxy ARP service is enabled. The capability is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 15 } dot11BSSTransitionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Decrepated as unnecessary; dot11BSSTransitionActivated is used instead. This is a capability variable. Its value is determined by device capabilities. This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting BSS transition management, when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 16 } dot11BSSTransitionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide BSS transition is enabled. The capability is disabled, otherwise. " DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 17 } dot11QoSTrafficCapabilityImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting QoS traffic capability when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 18 } dot11QoSTrafficCapabilityActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide QoS traffic capability is enabled. QoS traffic capability is disabled otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 19 } dot11ACStationCountImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting AC Station Count when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 20 } dot11ACStationCountActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide AC Station Count is enabled. AC Station Count is disabled otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 21 } dot11CoLocIntfReportingImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting Colocated Interference Reporting. The capability is disabled, otherwise." ::= { dot11WirelessMgmtOptionsEntry 22 } dot11CoLocIntfReportingActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to support Colocated Interference Reporting is enabled. The capability is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 23 } dot11MotionDetectionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting motion detection when dot11WirelessManagementImplemented is equal to true. " ::= { dot11WirelessMgmtOptionsEntry 24 } dot11MotionDetectionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability to support motion detection is enabled." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 25 } dot11TODImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting Time Of Departure for Clause 15 transmitted frames, Clause 17 transmitted frames, Clause 16 transmitted frames, Clause 18 transmitted frames and Clause 19 transmitted frames when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 26 } dot11TODActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability to support Time Of Departure frames for transmitted Clause 15, Clause 17, Clause 16, Clause 18 and Clause 19 frames is enabled." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 27 } dot11TimingMsmtImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting Timing Measurement capability when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 28 } dot11TimingMsmtActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect at the next occurrence of an MLME-START.request or MLME-JOIN.request primitive. This attribute, when true, indicates that the station capability for Timing Measurement is enabled. false indicates the station has no Timing Measurement capability or that the capability is present but is disabled." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 29 } dot11ChannelUsageImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting Channel Usage when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 30 } dot11ChannelUsageActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that Channel Usage is enabled. Channel Usage is disabled otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 31 } dot11TriggerSTAStatisticsActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide triggered STA statistics is enabled. The capability is disabled otherwise" DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 32 } dot11SSIDListImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting the SSID List capability when dot11WirelessManagementImplemented is true." ::= { dot11WirelessMgmtOptionsEntry 33 } dot11SSIDListActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to support the SSID List capability is enabled. The capability is disabled, otherwise" DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 34 } dot11MulticastDiagnosticsActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide multicast diagnostic reporting is enabled. The capability is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 35 } dot11LocationTrackingImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting Location Track when dot11WirelessManagementImplemented is true." ::= { dot11WirelessMgmtOptionsEntry 36 } dot11LocationTrackingActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide Location Track is enabled. The capability is disabled otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 37 } dot11DMSImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting DMS when dot11WirelessManagementImplemented is true." ::= { dot11WirelessMgmtOptionsEntry 38 } dot11DMSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that DMS is enabled. DMS is disabled otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 39 } dot11UAPSDCoexistenceImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the Station implementation is capable of supporting U-APSD coexistence when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 40} dot11UAPSDCoexistenceActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that U-APSD coexistence is enabled. U-APSD coexistence is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 41} dot11WNMNotificationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting WNM notification when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 42} dot11WNMNotificationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the capability of the station to provide WNM notification is enabled. The capability is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 43} dot11UTCTSFOffsetImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the Station implementation is capable of supporting UTC TSF Offset advertisement when dot11WirelessManagementImplemented is equal to true." ::= { dot11WirelessMgmtOptionsEntry 44} dot11UTCTSFOffsetActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that UTC TSF Offset advertisement is enabled at the station. The capability is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 45} dot11FineTimingMsmtRespActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect at the next occurrence of an MLME-START.request or MLME-JOIN.request primitive. This attribute, when true, indicates that the station capability for Fine Timing Measurement as a responder is enabled. false indicates the station has no Fine Timing Measurement capability as a responder or that the capability is present but is disabled." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 47 } dot11LciCivicInNeighborReport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the station includes LCI and civic location subelements in the neighbor report without regard to either dot11FineTimingMsmtRespActivated or dot11FineTimingMsmtInitActivated." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 48 } dot11RMFineTimingMsmtRangeRepImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting fine timing measurement range reporting." ::= { dot11WirelessMgmtOptionsEntry 49} dot11RMFineTimingMsmtRangeRepActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that fine timing measurement range reporting is enabled at the station. The capability is disabled, otherwise." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 50} dot11FineTimingMsmtInitActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect at the next occurrence of an MLME-START.request or MLME-JOIN.request primitive. This attribute, when true, indicates that the station capability for Fine Timing Measurement as an initiator is enabled. false indicates the station has no Fine Timing Measurement capability as an initiator or that the capability is present but is disabled." DEFVAL { false} ::= { dot11WirelessMgmtOptionsEntry 51 } dot11RMLCIConfigured OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity, which sets it to true when the external management entity configures a dot11STALCITable entry. It is written by the SME, which sets it to false when an external management entity configures dot11STACivicLocation and dot11STACivicLocationType. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that that the station is configured with an LCI location (LCI is not Unknown). false indicates the station is not configured with an LCI location or the configured LCI Location is set to Unknown (as defined in 9.4.2.21.10)." DEFVAL { false } ::= { dot11WirelessMgmtOptionsEntry 52 } dot11RMCivicConfigured OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity, which sets it to true when the external management entity configures dot11STACivicLocation and dot11STACivicLocationType. It is written by the SME, which sets it to false when an external management entity configures a dot11STALCITable entry. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the station is configured with a civic location (civic location is not Unknown). false indicates the station is not configured with an civic location or the configured civic Location is set to Unknown (as defined in 9.4.2.21.13)." DEFVAL { false } ::= { dot11WirelessMgmtOptionsEntry 53 } -- ******************************************************************** -- * dot11LocationServices TABLE -- ******************************************************************** dot11LocationServicesNextIndex OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies a hint for the next value of dot11LocationServicesIndex to be used in a row creation attempt for dot11LocationServicesTable. If no new rows can be created for some reason, such as memory, processing requirements, etc, the SME shall set this attribute to 0. It shall update this attribute to a proper value other than 0 as soon as it is capable of receiving new measurement requests. The nextIndex is not necessarily sequential nor monotonically increasing." ::= { dot11smt 19 } dot11LocationServicesTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11LocationServicesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains conceptual table of attributes for WNM LocationServices." ::= { dot11smt 20 } dot11LocationServicesEntry OBJECT-TYPE SYNTAX Dot11LocationServicesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11LocationServicesTable Indexed by dot11LocationServicesIndex." INDEX { dot11LocationServicesIndex } ::= { dot11LocationServicesTable 1 } Dot11LocationServicesEntry ::= SEQUENCE { dot11LocationServicesIndex Unsigned32, dot11LocationServicesMACAddress MacAddress, dot11LocationServicesLIPIndicationMulticastAddress MacAddress, dot11LocationServicesLIPReportIntervalUnits INTEGER, dot11LocationServicesLIPNormalReportInterval Unsigned32, dot11LocationServicesLIPNormalFramesperChannel Unsigned32, dot11LocationServicesLIPInMotionReportInterval Unsigned32, dot11LocationServicesLIPInMotionFramesperChannel Unsigned32, dot11LocationServicesLIPBurstInterframeInterval Unsigned32, dot11LocationServicesLIPTrackingDuration Unsigned32, dot11LocationServicesLIPEssDetectionInterval Unsigned32, dot11LocationServicesLocationIndicationChannelList OCTET STRING, dot11LocationServicesLocationIndicationBroadcastDataRate Unsigned32, dot11LocationServicesLocationIndicationOptionsUsed OCTET STRING, dot11LocationServicesLocationIndicationIndicationParameters OCTET STRING, dot11LocationServicesLocationStatus Unsigned32 } dot11LocationServicesIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This attribute contains an auxiliary index into the dot11LocationServicesTable." ::= { dot11LocationServicesEntry 1 } dot11LocationServicesMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute is the MAC address of the STA reporting location information." ::= { dot11LocationServicesEntry 2 } dot11LocationServicesLIPIndicationMulticastAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute is the destination address to which the Location Track Notification frames are sent in a BSS that is not an IBSS; see 9.4.2.70.2 and 11.21.4.1." ::= { dot11LocationServicesEntry 3 } dot11LocationServicesLIPReportIntervalUnits OBJECT-TYPE SYNTAX INTEGER { hours(0), minutes(1), seconds(2), milliseconds(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute contains the Location Indication Parameters Report Interval Units value." ::= { dot11LocationServicesEntry 4 } dot11LocationServicesLIPNormalReportInterval OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute contains the time interval, expressed in the units indicated in the Report Interval Units field, at which the reporting STA is expected to transmit one or more Location Track Notification frames if either dot11MotionDetectionActivated is false or the STA is stationary. The STA does not transmit Location Track Notification frames when the Normal Report Interval is 0." ::= { dot11LocationServicesEntry 5 } dot11LocationServicesLIPNormalFramesperChannel OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute contains the number of Location Track Notification frames per channel sent or expected to be sent by the STA at each Normal Report Interval." ::= { dot11LocationServicesEntry 6 } dot11LocationServicesLIPInMotionReportInterval OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute contains the time interval, expressed in the units indicated in the Report Interval Units field, at which the STA reports its location by sending a Location Track Notification frame when the reporting STA is in motion. If dot11MotionDetectionActivated is false, this field is set to 0." ::= { dot11LocationServicesEntry 7} dot11LocationServicesLIPInMotionFramesperChannel OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute contains the number of Location Track Notification frames per channel sent or expected to be sent by the STA at each In-Motion Report Interval. If dot11MotionDetectionActivated is false, this field is set to 0." ::= { dot11LocationServicesEntry 8 } dot11LocationServicesLIPBurstInterframeInterval OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute contains the target time interval between the transmissions of each of the Normal or In-Motion frames on the same channel. The Burst Inter-frame interval value is set to 0 to indicate that frames will be transmitted with no target inter-frame delay." ::= { dot11LocationServicesEntry 9 } dot11LocationServicesLIPTrackingDuration OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "minutes" MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute contains the amount of time that a STA sends the Location Track Notification frames. The duration starts as soon as the STA sends a Location Configuration Response frame with a Location Status value of Success. If the Tracking Duration value is a nonzero value the STA will send Location Track Notification frames, based on the Normal and In-Motion Report Interval field values, until the duration ends. If the Tracking Duration is 0 the STA will continuously send Location Track Notification frames as defined by Normal and In-Motion Report Interval field values until transmission is terminated based on 11.21.4.2 procedures." ::= { dot11LocationServicesEntry 10} dot11LocationServicesLIPEssDetectionInterval OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "minutes" MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute contains the interval that a STA checks for beacons transmitted by one or more APs belonging to the same ESS that configured the STA. If no beacons from the ESS are received for this period, the STA terminates transmission of Location Track Notification frames as described in 11.21.4.2 procedures. The ESS Detection Interval field is not used when the ESS Detection Interval field value is set to 0." ::= { dot11LocationServicesEntry 11} dot11LocationServicesLocationIndicationChannelList OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2..254)) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute contains one or more Operating Class and Channel octet pairs." ::= { dot11LocationServicesEntry 12} dot11LocationServicesLocationIndicationBroadcastDataRate OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute specifies the target data rate at which the STA transmits Location Track Notification frames. The Broadcast Target Data Rate field format is specified by the Rate Identification field defined in 9.4.1.32. A value of 0 indicates the STA transmits Location Track Notification frames at a rate chosen by the STA transmitting the Location Track Notification frames." DEFVAL { 0 } ::= { dot11LocationServicesEntry 13} dot11LocationServicesLocationIndicationOptionsUsed OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the location configuration options used for transmitting Location Track Notification frames." ::= { dot11LocationServicesEntry 14} dot11LocationServicesLocationIndicationIndicationParameters OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the location Indication Parameters used for transmitting Location Track Notification frames." ::= { dot11LocationServicesEntry 15} dot11LocationServicesLocationStatus OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains the Location Status value as indicated in Table 9-197, Event Report Status." ::= { dot11LocationServicesEntry 16 } -- ******************************************************************** -- * End of dot11LocationServices TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WirelessMGTEvent TABLE -- ******************************************************************** dot11WirelessMGTEventTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WirelessMGTEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of WIRELESS Management reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment the EventIndex for new reports being written in the table." ::= { dot11smt 21 } dot11WirelessMGTEventEntry OBJECT-TYPE SYNTAX Dot11WirelessMGTEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WirelessMGTEventTable Indexed by dot11WirelessMGTEventIndex." INDEX { dot11WirelessMGTEventIndex } ::= { dot11WirelessMGTEventTable 1 } Dot11WirelessMGTEventEntry ::= SEQUENCE { dot11WirelessMGTEventIndex Unsigned32, dot11WirelessMGTEventMACAddress MacAddress, dot11WirelessMGTEventType INTEGER, dot11WirelessMGTEventStatus INTEGER, dot11WirelessMGTEventTSF TSFType, dot11WirelessMGTEventUTCOffset OCTET STRING, dot11WirelessMGTEventTimeError OCTET STRING, dot11WirelessMGTEventTransitionSourceBSSID MacAddress, dot11WirelessMGTEventTransitionTargetBSSID MacAddress, dot11WirelessMGTEventTransitionTime Unsigned32, dot11WirelessMGTEventTransitionReason INTEGER, dot11WirelessMGTEventTransitionResult Unsigned32, dot11WirelessMGTEventTransitionSourceRCPI Unsigned32, dot11WirelessMGTEventTransitionSourceRSNI Unsigned32, dot11WirelessMGTEventTransitionTargetRCPI Unsigned32, dot11WirelessMGTEventTransitionTargetRSNI Unsigned32, dot11WirelessMGTEventRSNATargetBSSID MacAddress, dot11WirelessMGTEventRSNAAuthenticationType OCTET STRING, dot11WirelessMGTEventRSNAEAPMethod OCTET STRING, dot11WirelessMGTEventRSNAResult Unsigned32, dot11WirelessMGTEventRSNARSNElement OCTET STRING, dot11WirelessMGTEventPeerSTAAddress MacAddress, dot11WirelessMGTEventPeerOperatingClass Unsigned32, dot11WirelessMGTEventPeerChannelNumber Unsigned32, dot11WirelessMGTEventPeerSTATxPower Integer32, dot11WirelessMGTEventPeerConnectionTime Unsigned32, dot11WirelessMGTEventPeerPeerStatus Unsigned32, dot11WirelessMGTEventWNMLog OCTET STRING } dot11WirelessMGTEventIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains an auxiliary index into the dot11WirelessMGTEventTable." ::= { dot11WirelessMGTEventEntry 1 } dot11WirelessMGTEventMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the MAC address of the STA providing the Event report." ::= { dot11WirelessMGTEventEntry 2 } dot11WirelessMGTEventType OBJECT-TYPE SYNTAX INTEGER { transition(0), rsna(1), peerToPeer(2), wnmLog(3), vendorSpecific(221) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the request type of this WNM Event request." ::= { dot11WirelessMGTEventEntry 3 } dot11WirelessMGTEventStatus OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains the status value included in the Event report." ::= { dot11WirelessMGTEventEntry 4 } dot11WirelessMGTEventTSF OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains the value of the Event TSF field." ::= { dot11WirelessMGTEventEntry 5 } dot11WirelessMGTEventUTCOffset OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the UTC Offset Time Value optionally included in the Event report." ::= { dot11WirelessMGTEventEntry 6} dot11WirelessMGTEventTimeError OBJECT-TYPE SYNTAX OCTET STRING (SIZE(5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains the value of the Event Time Error field optionally included in the Event report." ::= { dot11WirelessMGTEventEntry 7} dot11WirelessMGTEventTransitionSourceBSSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains the value of the Source BSSID field in a Transition event report." ::= { dot11WirelessMGTEventEntry 8} dot11WirelessMGTEventTransitionTargetBSSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains the value of the Target BSSID field in a Transition event report." ::= { dot11WirelessMGTEventEntry 9} dot11WirelessMGTEventTransitionTime OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the transition time for the reported transition event in TUs. The Transition time is defined as the time difference between the starting time and the ending time of a transition between APs, even if the transition results in remaining on the same AP. Start and end times for a transition event are defined in 11.21.2.2" ::= { dot11WirelessMGTEventEntry 10} dot11WirelessMGTEventTransitionReason OBJECT-TYPE SYNTAX INTEGER { unspecified(0), excessiveFrameLossRatesPoorConditions(1), excessiveDelayForCurrentTrafficStreams(2), insufficientQosCapacityForCurrentTrafficStreams(3), firstAssociationToEss(4), loadBalancing(5), betterApFound(6), deauthenticatedDisassociatedFromPreviousAp(7), certificateToken(8), apFailedIeee8021XEapAuthentication(9), apFailed4wayHandshake(10), excessiveDataMICFailures(11), exceededFrameTransmissionRetryLimit(12), ecessiveBroadcastDisassociations(13), excessiveBroadcastDeauthentications(14), previousTransitionFailed(15) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the reason for the reported BSS transition event. The format for this list of reasons is further detailed in 9.4.2.67.2." ::= { dot11WirelessMGTEventEntry 11} dot11WirelessMGTEventTransitionResult OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the result of the attempted transition and is set to one of the status codes specified in Table 9-50." ::= { dot11WirelessMGTEventEntry 12 } dot11WirelessMGTEventTransitionSourceRCPI OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the received channel power of the most recently measured PPDU containing a frame from the Source BSSID before the STA reassociates to the Target BSSID. The Source RCPI is a logarithmic function of the received signal power, as defined in 9.4.2.37." ::= { dot11WirelessMGTEventEntry 13 } dot11WirelessMGTEventTransitionSourceRSNI OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the received signal-to-noise indication of the most recently measured frame from the Source BSSID before the STA reassociates to the Target BSSID. The Source RSNI is a logarithmic function of the signal-to-noise ratio, as defined in 9.4.2.40." ::= { dot11WirelessMGTEventEntry 14 } dot11WirelessMGTEventTransitionTargetRCPI OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the received channel power of the first measured PPDU containing a frame from the Target BSSID just after STA reassociates to the Target BSSID. If association with target BSSID failed, the Target RCPI field indicates the received channel power of the most recently measured PPDU containing a frame from the Target BSSID. The Target RCPI is a logarithmic function of the received signal power, as defined 9.4.2.37." ::= { dot11WirelessMGTEventEntry 15 } dot11WirelessMGTEventTransitionTargetRSNI OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the received signal-to-noise indication of the first measured frame just after STA reassociates to the Target BSSID. If association with target BSSID failed, the Target RSNI field indicates the received signal-to-noise indication of the most recently measured frame from the Target BSSID. The Target RSNI is a logarithmic function of the signal-to-noise ratio, as defined in 9.4.2.40." ::= { dot11WirelessMGTEventEntry 16 } dot11WirelessMGTEventRSNATargetBSSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains the value of the Target BSSID field in an RSNA event report." ::= { dot11WirelessMGTEventEntry 17 } dot11WirelessMGTEventRSNAAuthenticationType OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the AKM suite, as defined in Table 9-151. The first three octets indicate the OUI or CID. The last octet indicates the suite type." ::= { dot11WirelessMGTEventEntry 18 } dot11WirelessMGTEventRSNAEAPMethod OBJECT-TYPE SYNTAX OCTET STRING(SIZE (1..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a value that identifies the EAP Method. When the Authentication Type field is set to the value of either 00-0F-AC:1 (Authentication negotiated over IEEE Std 802.1X or using PMKSA caching as defined in 12.6.10.3) or 00-0F-AC:3 (AKM suite selector for fast BSS transition as defined in 12.7.1.6), the EAP Method field contains the IANA assigned EAP type defined at http://www.iana.org/assignments/eap-numbers. The EAP type contains either the legacy type (1 octet) or the expanded type (1-octet type = 254, 3-octet Vendor ID, 4-octet Vendor-Type). The EAP Method field is set to 0 otherwise." ::= { dot11WirelessMGTEventEntry 19 } dot11WirelessMGTEventRSNAResult OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the result of the RSNA event and is set to one of the status codes specified in Table 9-50." ::= { dot11WirelessMGTEventEntry 20} dot11WirelessMGTEventRSNARSNElement OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..257)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains the entire contents of the negotiated RSNE at the time of the authentication attempt. The format of the RSNE is defined in 9.4.2.24." ::= { dot11WirelessMGTEventEntry 21} dot11WirelessMGTEventPeerSTAAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the MAC address of the peer STA or IBSS BSSID is equal to the indicated MAC address. If this event is for a peer-to-peer link in an infrastructure BSS, this field contains the MAC address of the peer STA. If this event is for a peer-to-peer link in an IBSS, this field contains the BSSID." ::= { dot11WirelessMGTEventEntry 22 } dot11WirelessMGTEventPeerOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the channel set for this peer-to-peer link event report. Country, Operating Class, and Channel Number together specify the channel frequency and spacing for this measurement request. Valid values of Operating Class are shown in Annex E." ::= { dot11WirelessMGTEventEntry 23 } dot11WirelessMGTEventPeerChannelNumber OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the current operating channel for this peer-to-peer event report. The Channel Number is defined only within the indicated Operating Class as shown in Annex E." ::= { dot11WirelessMGTEventEntry 24 } dot11WirelessMGTEventPeerSTATxPower OBJECT-TYPE SYNTAX Integer32 (-128..127) UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the STA transmit power used for the peer-to-peer link. The STA Tx Power field indicates the target transmit power at the antenna connector with a tolerance of +/-5 dB for the lowest basic rate of the reporting STA. A value of -128 indicates that the value is unknown." ::= { dot11WirelessMGTEventEntry 25 } dot11WirelessMGTEventPeerConnectionTime OBJECT-TYPE SYNTAX Unsigned32 (0..16777215) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a value representing the connection time for the reported peer-to-peer link event. If the Peer Status is 0, this field indicates the duration of the Direct Link. If the Peer Status is 1, this field indicates the time difference from the time the Direct Link was established to the time at which the reporting STA generated the event report. If the Peer Status is 2, this field indicates the duration of the IBSS membership. If the Peer Status is 3, this field indicates the time difference from the time the STA joined the IBSS to the time at which the reporting STA generated the event report. See 11.21.2.4." ::= { dot11WirelessMGTEventEntry 26 } dot11WirelessMGTEventPeerPeerStatus OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Peer link connection status as indicated in Table 9-199. See 9.4.2.67.4." ::= { dot11WirelessMGTEventEntry 27 } dot11WirelessMGTEventWNMLog OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..2284)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute contains the entire syslog message, consisting of the PRI, HEADER, and MSG portion of a WNM log message as described in IETF RFC 5424. The TAG field of the MSG portion of the message is a 17-octet string containing the ASCII representation of the STA MAC address using hexadecimal notation with colons between octets. The octet containing the Individual/Group bit occurs last, and that bit is in the least significant position within that octet. See 11.21.2.5." ::= { dot11WirelessMGTEventEntry 28 } -- ******************************************************************** -- * End of dot11WirelessMGTEvent TABLE -- ******************************************************************** -- ********************************************************************** -- * IEEE 802.11 RM and WNM Interface MIB -- ********************************************************************** -- * The primary interface to the radio measurements and Wireless -- * Network Management functions is meant to be real-time information -- * obtained through the request/response mechanisms of RM and WNM. -- * A secondary interface to the measurements and management functions -- * is through retention of information in this MIB. Non-SNMP requests -- * for information are obtained via object IDs (OIDs) through the NDIS -- * or wireless interfaces in the operating systems. SNMP requests for -- * information are obtained via SNMP SETs and GETs (see IETF RFC 1157 [B23]). -- * dot11RMRequest and dot11RMReport Usage -- * -- * The dot11RMRequest and dot11RMReport portions of the RM MIB -- * provide access to the Radio Measurement service. By performing -- * SET operations on the various dot11RMRequest MIB objects, -- * radio measurements may be initiated directly on the local STA or -- * on any peer station within the same BSS. Subsequently, by -- * performing GET operations on the various dot11RMReport MIB -- * objects the results of the requested measurements may be -- * retrieved. -- * -- * In the diagram below, a radio measurement could be initiated -- * for STA x by performing a MIB.set operation on the RM MIB of -- * STA x and specifying the MAC address of STA x in -- * dot11RMRqstTargetAdd. Additionally, it is possible to have STA x -- * request a measurement from STA y by performing a MIB.set operation -- * on the SME MIB of STA x and specifying the MAC address of STA y in -- * dot11RMRqstTargetAdd. In both cases the result of the measurements -- * can be retrieved by performing a MIB.get operation on the RM MIB -- * of STA x upon completion of the measurement. -- * -- * -- * MIB.Set MIB.Set -- * or or -- * MIB.Get MIB.Get -- * +========|=========+ +========|=========+ -- * | SME | | | SME | | -- * | \ / | | \ / | -- * | +=========+ | | +=========+ | -- * | | RM and | | | | RM and | | -- * | | WNM MIB | | | | WNM MIB | | -- * | | | | | | | | -- * | | | | | | | | -- * | +=========+ | | +=========+ | -- * | | | | -- * | / \ | | / \ | -- * | | MREQUEST | | | MREQUEST | -- * +====+=============+ +====+=============+ -- * | | MREPORT | | | MREPORT | -- * | \ / MEASURE | Action frames | \ / MEASURE | -- * | | <==Measurement Request==> | | -- * | | <==Measurement Report===> | | -- * | MLME | | MLME | -- * +==================+ +==================+ -- * STA x STA y -- * -- * Each STA maintains a single dot11RMRequestTable in the SME MIB -- * used to initiate RM Measurement Requests. Each dot11RMRequestEntry -- * in the table represents an individual Measurement Request that -- * makes up a complete Measurement Request frame. -- * Multiple Measurement Requests may be concatenated into a single -- * Measurement Request frame by setting the same -- * dot11RMRqstToken value into multiple dot11RMRequestEntrys. -- * -- * Each row, dot11RMRequestEntry, of the dot11RMRequestTable -- * provides read-create access for the initiation of a measurement -- * request. The dot11RMRequestNextIndex object can be used to -- * determine which is the next available row. Each row corresponding to -- * one measurement in the sequence is created with a dot11RMRqstRowStatus -- * equal to notInService. Once the dot11RMRequestEntry(s) have been -- * created for a desired measurement sequence the corresponding -- * dot11RMRqstRowStatus(s) objects are set to active to indicate that -- * the SME can trigger the appropriate MLME primitives. Upon processing -- * the request, the SME returns the corresponding dot11RMRqstRowStatus(s) -- * object to notInService and are now available for additional -- * measurement requests. -- * -- * After a radio measurement is complete the RM populates the RMReport -- * objects with the results of the measurement. Each STA maintains a set -- * of RMReport tables, one corresponding to each measurement type. The -- * results of the entire measurement sequence are spread across the tables -- * based on the type of measurements requested. Each xxxReportEntry -- * within a xxxReportTable contains a xxxRprtRqstToken that corresponds -- * to the original dot11RMRqstToken in the measurement request. So the -- * results of the measurement can be collected by searching the appropriate -- * xxxReportTables and retrieve any reports with the matching request -- * token. -- * -- * Similar structures and mechanisms are used for WNM -- * Request and Reports. The WNM MIB definitions follow the RM MIB definitions -- * in this Annex. -- ********************************************************************** -- ******************************************************************** -- * Radio Measurement Interface MIB -- ******************************************************************** dot11RadioMeasurement OBJECT IDENTIFIER ::= { dot11smt 14 } -- ******************************************************************** -- * Radio Measurement Requests -- ******************************************************************** dot11RMRequest OBJECT IDENTIFIER ::= { dot11RadioMeasurement 1 } -- ******************************************************************** -- * dot11RMRequest TABLE -- ******************************************************************** dot11RMRequestNextIndex OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when able to accept a new request. Identifies a hint for the next value of dot11RMRqstIndex to be used in a row creation attempt for dot11RMRequestTable. If no new rows can be created for some reason, such as memory, processing requirements, etc., the SME sets this attribute to 0. It updates this attribute to a proper value other than 0 as soon as it is capable of receiving new measurement requests. The nextIndex is not necessarily sequential nor monotonically increasing." ::= { dot11RMRequest 1 } dot11RMRequestTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RMRequestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This group contains the current list of requests for RM reports to be issued and have been issued until removed. A network manager adds an RM request by creating a row with createAndWait row status and then filling in the request parameters/attributes. The request becomes active to be issued when the row status is set to Active. The columnar objects or attributes other than the rowStatus are not written if the rowStatus is Active. The request rows can be deleted, if commanded by a network manager via changing the value of dot11RMRqstRowStatus to Destroy. This may leave orphaned rows if a manager crashes and forgets which rows are being used by it. One recommended way to manage orphaned or finished rows is to delete rows if their dot11RMRqstRowStatus remains other than Active for longer than a period (recommend at least 5 minutes, IETF RFC 2579). Or another recommended way is to delete older rows as needed based on their dot11RMRqstTimeStamp values. This can be done by the agent as well as the manager. " ::= { dot11RMRequest 2 } dot11RMRequestEntry OBJECT-TYPE SYNTAX Dot11RMRequestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11RMRequestTable Indexed by dot11RMRqstIndex." INDEX { dot11RMRqstIndex } ::= { dot11RMRequestTable 1 } Dot11RMRequestEntry ::= SEQUENCE { dot11RMRqstIndex Unsigned32, dot11RMRqstRowStatus RowStatus, dot11RMRqstToken OCTET STRING, dot11RMRqstRepetitions Unsigned32, dot11RMRqstIfIndex InterfaceIndex, dot11RMRqstType INTEGER, dot11RMRqstTargetAdd MacAddress, dot11RMRqstTimeStamp TimeTicks, dot11RMRqstChanNumber Unsigned32, dot11RMRqstOperatingClass Unsigned32, dot11RMRqstRndInterval Unsigned32, dot11RMRqstDuration Unsigned32, dot11RMRqstParallel TruthValue, dot11RMRqstEnable TruthValue, dot11RMRqstRequest TruthValue, dot11RMRqstReport TruthValue, dot11RMRqstDurationMandatory TruthValue, dot11RMRqstBeaconRqstMode INTEGER, dot11RMRqstBeaconRqstDetail INTEGER, dot11RMRqstFrameRqstType INTEGER, dot11RMRqstBssid MacAddress, dot11RMRqstSSID OCTET STRING, dot11RMRqstBeaconReportingCondition INTEGER, dot11RMRqstBeaconThresholdOffset Integer32, dot11RMRqstSTAStatRqstGroupID INTEGER, dot11RMRqstLCIRqstSubject INTEGER, dot11RMRqstLCIAzimuthType INTEGER, dot11RMRqstLCIAzimuthResolution Unsigned32, dot11RMRqstPauseTime Unsigned32, dot11RMRqstTransmitStreamPeerQSTAAddress MacAddress, dot11RMRqstTransmitStreamTrafficIdentifier Unsigned32, dot11RMRqstTransmitStreamBin0Range Unsigned32, dot11RMRqstTrigdQoSAverageCondition TruthValue, dot11RMRqstTrigdQoSConsecutiveCondition TruthValue, dot11RMRqstTrigdQoSDelayCondition TruthValue, dot11RMRqstTrigdQoSAverageThreshold Unsigned32, dot11RMRqstTrigdQoSConsecutiveThreshold Unsigned32, dot11RMRqstTrigdQoSDelayThresholdRange Unsigned32, dot11RMRqstTrigdQoSDelayThreshold Unsigned32, dot11RMRqstTrigdQoSMeasurementCount Unsigned32, dot11RMRqstTrigdQoSTimeout Unsigned32, dot11RMRqstChannelLoadReportingCondition INTEGER, dot11RMRqstChannelLoadReference Unsigned32, dot11RMRqstNoiseHistogramReportingCondition INTEGER, dot11RMRqstAnpiReference Unsigned32, dot11RMRqstAPChannelReport OCTET STRING, dot11RMRqstSTAStatPeerSTAAddress MacAddress, dot11RMRqstFrameTransmitterAddress MacAddress, dot11RMRqstVendorSpecific OCTET STRING, dot11RMRqstSTAStatTrigMeasCount Unsigned32, dot11RMRqstSTAStatTrigTimeout Unsigned32, dot11RMRqstSTAStatTrigCondition OCTET STRING, dot11RMRqstSTAStatTrigSTAFailedCntThresh Unsigned32, dot11RMRqstSTAStatTrigSTAFCSErrCntThresh Unsigned32, dot11RMRqstSTAStatTrigSTAMultRetryCntThresh Unsigned32, dot11RMRqstSTAStatTrigSTAFrameDupeCntThresh Unsigned32, dot11RMRqstSTAStatTrigSTARTSFailCntThresh Unsigned32, dot11RMRqstSTAStatTrigSTAAckFailCntThresh Unsigned32, dot11RMRqstSTAStatTrigSTARetryCntThresh Unsigned32, dot11RMRqstSTAStatTrigQoSTrigCondition OCTET STRING, dot11RMRqstSTAStatTrigQoSFailedCntThresh Unsigned32, dot11RMRqstSTAStatTrigQoSRetryCntThresh Unsigned32, dot11RMRqstSTAStatTrigQoSMultRetryCntThresh Unsigned32, dot11RMRqstSTAStatTrigQoSFrameDupeCntThresh Unsigned32, dot11RMRqstSTAStatTrigQoSRTSFailCntThresh Unsigned32, dot11RMRqstSTAStatTrigQoSAckFailCntThresh Unsigned32, dot11RMRqstSTAStatTrigQoSDiscardCntThresh Unsigned32, dot11RMRqstSTAStatTrigRsnaTrigCondition OCTET STRING, dot11RMRqstSTAStatTrigRsnaCMACICVErrCntThresh Unsigned32, dot11RMRqstSTAStatTrigRsnaCMACReplayCntThresh Unsigned32, dot11RMRqstSTAStatTrigRsnaRobustCCMPReplayCntThresh Unsigned32, dot11RMRqstSTAStatTrigRsnaTKIPICVErrCntThresh Unsigned32, dot11RMRqstSTAStatTrigRsnaTKIPReplayCntThresh Unsigned32, dot11RMRqstSTAStatTrigRsnaCCMPDecryptErrCntThresh Unsigned32, dot11RMRqstSTAStatTrigRsnaCCMPReplayCntThresh Unsigned32 } dot11RMRqstIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for RM Request elements in dot11RMRequestTable, greater than 0." ::= { dot11RMRequestEntry 1 } dot11RMRqstRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement, and by the SME when accepting a measurement request. The Row Status column of the current row, used for tracking status of an individual request. When this attribute is set to Active, AND a measurement request can be unambiguously created based on the parameters in the row, then the MLME may proceed to issue the request to its intended targets when appropriate. If not, this attribute may be set to Not-ready immediately to indicate parametric errors. However, it is the network managers responsibility to correct the error. If the request is successfully issued to the target STA, then the rowStatus is set to notInService." ::= { dot11RMRequestEntry 2 } dot11RMRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when the table entry is created, i.e., when requesting a measurement.. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates a unique string to identify a group of rows to be issued as parallel or sequential measurements. To guarantee the uniqueness of this token across multiple network managers, it is recommended that this token be prefixed with the IP address of the network manager creating this row. This token is not necessarily equivalent to the measurement tokens in RM request frames. If this attribute is an empty string, then this row of request is independent from other requests." DEFVAL { "" } ::= { dot11RMRequestEntry 3 } dot11RMRqstRepetitions OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the requested number of repetitions for all of the Measurement Request elements in this frame. A value of 0 in the Number of Repetitions field indicates Measurement Request elements are executed once without repetition." ::= { dot11RMRequestEntry 4 } dot11RMRqstIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. The ifIndex on which this row of the RM Request is to be issued." ::= { dot11RMRequestEntry 5 } dot11RMRqstType OBJECT-TYPE SYNTAX INTEGER { channelLoad(3), noiseHistogram(4), beacon(5), frame(6), staStatistics(7), lci(8), transmitStream(9), pause(255) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the measurement type of this RM request row." ::= { dot11RMRequestEntry 6 } dot11RMRqstTargetAdd OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. The MAC address of STA for this row of RM Request is to be issued to. If this attribute matches the MAC address of the dot11RMRqstIfIndex, then measurement request is for this STA itself to carry out." ::= { dot11RMRequestEntry 7 } dot11RMRqstTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by the SME when dot11RMRqstRowStatus is set to Active. This attribute indicates the sysUpTime Value the last time when dot11RMRqstRowStatus is set to active or when this row is created the first time." ::= { dot11RMRequestEntry 8 } dot11RMRqstChanNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. The target STA channel number on which to perform the measurements indicated in this request. The Channel Number is defined only within the indicated Operating Class for this measurement request. This attribute is ignored if dot11RMRqstType = STA Statistics, LCI, Transmit Stream/Category Measurement, or Measurement Pause. However, even in that case, the manager should set this attribute to the current channel for this interface, so that the row can be set to active when ready with all attributes indicated." ::= { dot11RMRequestEntry 9 } dot11RMRqstOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the channel set for this measurement request. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement request. Valid values of Operating Class are shown in Annex E." ::= { dot11RMRequestEntry 10 } dot11RMRqstRndInterval OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the upper bound of the random delay to be used prior to making the measurement. See 11.10.3. This attribute is ignored if dot11RMRqstType = STA Statistics, LCI, Transmit Stream/Category Measurement or Measurement Pause." DEFVAL { 0 } ::= { dot11RMRequestEntry 11 } dot11RMRqstDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the preferred or mandatory measurement duration for this Measurement Request. This attribute is ignored if dot11RMRqstType = LCI or Measurement Pause." DEFVAL { 0 } ::= { dot11RMRequestEntry 12 } dot11RMRqstParallel OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the parallel bit for this Measurement Request element. This attribute, when false, indicates that the measurement is performed in sequence. This attribute, when true, indicates that this measurement should start at the same time as the measurement described by the next Measurement Request element in the next row if the next row indicates the same value for dot11RMRqstToken." DEFVAL { false } ::= { dot11RMRequestEntry 13 } dot11RMRqstEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the enable bit for this Measurement Request element." DEFVAL { false } ::= { dot11RMRequestEntry 14 } dot11RMRqstRequest OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the request bit for this Measurement Request element. This attribute, when true, indicates that this STA accepts measurement requests from the target STA." DEFVAL { false } ::= { dot11RMRequestEntry 15 } dot11RMRqstReport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the report bit for this Measurement Request element. This attribute, when true, indicates that the target STA may enable autonomous measurement reports to the requesting STA." DEFVAL { false } ::= { dot11RMRequestEntry 16 } dot11RMRqstDurationMandatory OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the duration mandatory bit for this Measurement Request element. This attribute, when true, indicates that the indicated Measurement Duration is a mandatory duration for this measurement. This attribute, when false, indicates that the indicated Measurement Duration is a maximum duration for this measurement." DEFVAL { false } ::= { dot11RMRequestEntry 17 } dot11RMRqstBeaconRqstMode OBJECT-TYPE SYNTAX INTEGER { passive(0), active(1), beaconTable(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the Measurement Mode for this Beacon request. This attribute is valid only if the dot11RMRqstType is 5, indicating a Beacon request, and is ignored otherwise." DEFVAL { 0 } ::= { dot11RMRequestEntry 18 } dot11RMRqstBeaconRqstDetail OBJECT-TYPE SYNTAX INTEGER { noBody(0), fieldsAndRequestedElements(1), allBody(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. dot11RMRqstBeaconRqstDetail indicates the Reporting Detail for Beacon request. This attribute is valid only if the dot11RMRqstType is 5, indicating a Beacon request, and is ignored otherwise." DEFVAL { 2 } ::= { dot11RMRequestEntry 19 } dot11RMRqstFrameRqstType OBJECT-TYPE SYNTAX INTEGER { frameCountRep(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. dot11RMRqstFrameRqstType indicates the Frame Request Type for the Frame request. This attribute is valid only if the dot11RMRqstType is 6, indicating a Frame request, and is ignored otherwise." DEFVAL { 1 } ::= { dot11RMRequestEntry 20 } dot11RMRqstBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. BSSID indicates the BSSID of the BSS of the particular AP for which this measurement is requested. The BSSID is set to the wildcard BSSID when the measurement is to be performed on the BSS(s) of any AP(s) on the indicated channel. This attribute is valid only if the dot11RMRqstType is 5, indicating a Beacon request, and is ignored otherwise." DEFVAL { 'FFFFFFFFFFFF'H } ::= { dot11RMRequestEntry 21 } dot11RMRqstSSID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the SSID for the measurement. Zero-length MIB element for SSID indicates the wildcard SSID. The SSID is set to the wildcard SSID when the measurement is to be performed on all ESSs/IBSSs on the indicated channel. This attribute is valid only if the dot11RMRqstType is 5, indicating a Beacon request, and is ignored otherwise." DEFVAL { ''H } ::= { dot11RMRequestEntry 22 } dot11RMRqstBeaconReportingCondition OBJECT-TYPE SYNTAX INTEGER { afterEveryMeasurement(0), rcpiAboveAbsoluteThreshold(1), rcpiBelowAbsoluteThreshold(2), rsniAboveAbsoluteThreshold(3), rsniBelowAbsoluteThreshold(4), rcpiAboveOffsetThreshold(5), rcpiBelowOffsetThreshold(6), rsniAboveOffsetThreshold(7), rsniBelowOffsetThreshold(8), rcpiInBound(9), rsniInBound(10) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates when the Beacon Measurement results are to be reported to the requesting STA. This attribute is valid only if the dot11RMRqstType is 5, indicating a Beacon request, and is ignored otherwise." REFERENCE "IEEE Std 802.11-2020, Table 9-105, Reporting Condition values for Beacon request" DEFVAL {0} ::= { dot11RMRequestEntry 23 } dot11RMRqstBeaconThresholdOffset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. Threshold/Offset provides either the threshold value or the offset value to be used for conditional reporting. For indicated reporting conditions 1-4, the integer range is (0..255). For indicated reporting conditions 5-10, the integer range is (-127..+127). This attribute is valid only if the dot11RMRqstType is 5, indicating a Beacon request, and is ignored otherwise." DEFVAL { 0 } ::= { dot11RMRequestEntry 24 } dot11RMRqstSTAStatRqstGroupID OBJECT-TYPE SYNTAX INTEGER { dot11CountersTable(0), dot11MacStatistics(1), dot11QosCountersTableforUP0(2), dot11QosCountersTableforUP1(3), dot11QosCountersTableforUP2(4), dot11QosCountersTableforUP3(5), dot11QosCountersTableforUP4(6), dot11QosCountersTableforUP5(7), dot11QosCountersTableforUP6(8), dot11QosCountersTableforUP7(9), bSSAverageAccessDelays(10), dot11CountersGroup3Tablefor31(11), dot11CountersGroup3Tablefor32(12), dot11CountersGroup3Tablefor33(13), dot11CountersGroup3Tablefor34(14), dot11CountersGroup3Tablefor35(15), dot11RSNAStatsTable(16)} MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. The attribute indicates the group identity for this Measurement Request element. This attribute is valid only if the dot11RMRqstType is 7, indicating a STA statistics request, and is ignored otherwise." DEFVAL { 0 } ::= { dot11RMRequestEntry 25 } dot11RMRqstLCIRqstSubject OBJECT-TYPE SYNTAX INTEGER { local(0), remote(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. The attribute indicates the subject of the LCI request. This attribute is valid only if the dot11RMRqstType is 8, indicating an LCI request, and is ignored otherwise." DEFVAL { 0 } ::= { dot11RMRequestEntry 26 } -- 27 to 29 are reserved dot11RMRqstLCIAzimuthType OBJECT-TYPE SYNTAX INTEGER { frontSurfaceofSta(0), radioBeam(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the azimuth reference for the LCI Azimuth measurement request. This attribute is valid only if the dot11RMRqstType is 8, indicating an LCI request, and is ignored otherwise." DEFVAL{ 0 } ::= { dot11RMRequestEntry 30 } dot11RMRqstLCIAzimuthResolution OBJECT-TYPE SYNTAX Unsigned32 (0..15) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute is 4 bits indicating the number of valid bits in the fixed-point value of Azimuth of the LCI Azimuth measurement request. This attribute is valid only if the dot11RMRqstType is 8, indicating an LCI request, and is ignored otherwise." ::= { dot11RMRequestEntry 31 } dot11RMRqstPauseTime OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "10 TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the time period for which measurements are suspended or paused. Measurement Pause requests are used to provide time delays between the execution times of measurement request elements in a Measurement Request frame. This attribute is valid only if the dot11RMRqstType is 255, indicating an pause request, and is ignored otherwise." DEFVAL { 0 } ::= { dot11RMRequestEntry 32 } dot11RMRqstTransmitStreamPeerQSTAAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the peer STA address to be measured for a Transmit Stream/Category Measurement measurement. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." ::= { dot11RMRequestEntry 33 } dot11RMRqstTransmitStreamTrafficIdentifier OBJECT-TYPE SYNTAX Unsigned32 (0..16) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the TC, or TS to be measured for a Transmit Stream/Category Measurement measurement. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." ::= { dot11RMRequestEntry 34 } dot11RMRqstTransmitStreamBin0Range OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the delay range for bin 0 of the transmit delay histogram. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." ::= { dot11RMRequestEntry 35 } dot11RMRqstTrigdQoSAverageCondition OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute, when true, indicates a request for triggered reporting with trigger based on the number of discarded MSDUs reaching the dot11RMRqstTrigdQoSAverageThreshold when averaged over dot11RMRqstTrigdQoSMeasurementCount consecutive MSDUs. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." DEFVAL { false } ::= { dot11RMRequestEntry 36 } dot11RMRqstTrigdQoSConsecutiveCondition OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute, when true, indicates a request for triggered reporting with trigger based on the consecutive number of MSDUs discarded reaching dot11RMRqstTrigdQoSConsecutiveThreshold. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." DEFVAL { false } ::= { dot11RMRequestEntry 37 } dot11RMRqstTrigdQoSDelayCondition OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute, when true, indicates a request for triggered reporting with trigger based on the consecutive number of MSDUs that experience a transmit delay greater than dot11RMRqstTrigdQoSDelayThresholdRange reaching dot11RMRqstTrigdQoSDelayThreshold. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." DEFVAL { false } ::= { dot11RMRequestEntry 38 } dot11RMRqstTrigdQoSAverageThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the trigger threshold for triggered Transmit Stream/Category Measurement based on average MSDUs discarded. Trigger occurs if the number of MSDUs discarded over the moving average number of transmitted MSDUs in dot11RMRqstTrigdQoSMeasurementCount reaches this threshold. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." DEFVAL { 10 } ::= { dot11RMRequestEntry 39 } dot11RMRqstTrigdQoSConsecutiveThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the trigger threshold for triggered Transmit Stream/Category Measurement based on consecutive MSDUs discarded. Trigger occurs if the consecutive number of MSDUs discarded reaches this threshold. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." DEFVAL { 5 } ::= { dot11RMRequestEntry 40 } dot11RMRqstTrigdQoSDelayThresholdRange OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the minimum transmit delay for delayed MSDU counts. Trigger occurs if the a consecutive number of MSDUs experience a transmit delay greater than or equal to the lower bound of the bin of the Transmit Delay Histogram given by the value of this attribute + 2, e.g.,if this attribute is 1 the lower bound of bin 3. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." DEFVAL { 1 } ::= { dot11RMRequestEntry 41 } dot11RMRqstTrigdQoSDelayThreshold OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the number of consecutive delayed MSDUs needed for trigger. Trigger occurs if the consecutive number of MSDUs that experience a transmit delay greater than dot11RMRqstTrigdQoSDelayThresholdRange reaches this value. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." DEFVAL { 20 } ::= { dot11RMRequestEntry 42 } dot11RMRqstTrigdQoSMeasurementCount OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the number of MSDUs to be used as a moving average count in the average error threshold and in determining the scope of the reported Transmit Stream/Category measurement in a triggered measurement report. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." DEFVAL { 100 } ::= { dot11RMRequestEntry 43 } dot11RMRqstTrigdQoSTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..255) UNITS "100 TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the timeout interval during which a measuring STA does not generate further triggered Transmit Stream/Category measurement reports after a trigger condition has been met and a report generated. This attribute is valid only if the dot11RMRqstType is 9, indicating a transmit stream/category request, and is ignored otherwise." DEFVAL { 20 } ::= { dot11RMRequestEntry 44 } dot11RMRqstChannelLoadReportingCondition OBJECT-TYPE SYNTAX INTEGER { afterEveryMeasurement(0), chanLoadAboveReference(1), chanLoadBelowReference(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates when the Channel Load Measurement results are to be reported to the requesting STA. This attribute is valid only if the dot11RMRqstType is 3, indicating a Channel Load request, and is ignored otherwise." DEFVAL {0} ::= { dot11RMRequestEntry 45 } dot11RMRqstChannelLoadReference OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "1/255" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the channel load reporting condition reference value. The measured Channel Load is compared to this reference value and a report is issued if the reporting condition is satisfied. The reference value is in the same units as Channel Load and represents the fractional time of the measurement duration during which the STA determined the channel to be busy. This attribute is valid only if the dot11RMRqstType is 3, indicating a Channel Load request, and is ignored otherwise." DEFVAL { 5 } ::= { dot11RMRequestEntry 46 } dot11RMRqstNoiseHistogramReportingCondition OBJECT-TYPE SYNTAX INTEGER { afterEveryMeasurement(0), aNPIAboveReference(1), aNPIBelowReference(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates when the Noise Histogram Measurement results are to be reported to the requesting STA. This attribute is valid only if the dot11RMRqstType is 4, indicating a Noise Histogram request, and is ignored otherwise." DEFVAL {0} ::= { dot11RMRequestEntry 47 } dot11RMRqstAnpiReference OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the noise histogram reporting condition ANPI reference value. The measured ANPI is compared to this reference value and a report is issued if the indicated reporting condition is satisfied. ANPIval = Floor((ANPIpower in dBm + 110)*2), for ANPI in the range -110 dBm to 0 dBm. ANPIval = 220 for ANPI > 0 dBm. ANPIval = 255 when ANPI is not available. This attribute is valid only if the dot11RMRqstType is 4, indicating a Noise Histogram request, and is ignored otherwise." DEFVAL { 5 } ::= { dot11RMRequestEntry 48 } dot11RMRqstAPChannelReport OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the specific channels to be used for the requested beacon measurements. Each octet indicates a different channel within the indicated Operating Class. This list of channels is the Channel List field in the AP Channel Report element described in 9.4.2.35. This attribute is valid only if the dot11RMRqstType is 5, indicating a Beacon request, and is ignored otherwise." DEFVAL { ''H } ::= { dot11RMRequestEntry 49 } dot11RMRqstSTAStatPeerSTAAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the peer STA address to be measured for a STA statistics request. This attribute is valid only if the dot11RMRqstType is 7, indicating a statistics request, and is ignored otherwise." ::= { dot11RMRequestEntry 50 } dot11RMRqstFrameTransmitterAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates the Transmitter Address (TA) of the frames to be counted in this Frame request. This attribute is valid only if the dot11RMRqstType is 6, indicating a Frame request, and is ignored otherwise." ::= { dot11RMRequestEntry 51 } dot11RMRqstVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute provides an envelope for any optional vendor specific subelements which may be included in a Measurement Request element. This attribute is valid for all requests." DEFVAL { ''H } ::= { dot11RMRequestEntry 52 } dot11RMRqstSTAStatTrigMeasCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the number of MSDUs or MPDUs over which the trigger criterion is applied. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 53 } dot11RMRqstSTAStatTrigTimeout OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "100 TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the interval during which a measuring STA does not generate further triggered STA Statistics reports after a trigger condition has been met. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics)." DEFVAL { 0 } ::= { dot11RMRequestEntry 54 } dot11RMRqstSTAStatTrigCondition OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the trigger values used when requesting triggered STA Statistics reporting. The format of the STA Counter Trigger Condition field is shown in Figure 9-193." ::= { dot11RMRequestEntry 55 } dot11RMRqstSTAStatTrigSTAFailedCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11FailedCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 0 (dot11CountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 56 } dot11RMRqstSTAStatTrigSTAFCSErrCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11FCSErrorCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 0 (dot11CountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 57 } dot11RMRqstSTAStatTrigSTAMultRetryCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11MultipleRetryCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 0 (dot11CountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 58 } dot11RMRqstSTAStatTrigSTAFrameDupeCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11FrameDuplicateCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 0 (dot11CountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 59 } dot11RMRqstSTAStatTrigSTARTSFailCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11RTSFailureCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 0 (dot11CountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 60 } dot11RMRqstSTAStatTrigSTAAckFailCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11AckFailureCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 0 (dot11CountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 61 } dot11RMRqstSTAStatTrigSTARetryCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11RetryCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 0 (dot11CountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 62 } dot11RMRqstSTAStatTrigQoSTrigCondition OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the trigger values used when requesting triggered QoS STA Statistics reporting. The format of the STA Counter Trigger Condition field is shown in Figure 9-195." ::= { dot11RMRequestEntry 63 } dot11RMRqstSTAStatTrigQoSFailedCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11QosFailedCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 2 to 9 (dot11QosCountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 64 } dot11RMRqstSTAStatTrigQoSRetryCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11QosRetryCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 2 to 9 (dot11QosCountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 65 } dot11RMRqstSTAStatTrigQoSMultRetryCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11QosMultipleRetryCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 2 to 9 (dot11QosCountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 66 } dot11RMRqstSTAStatTrigQoSFrameDupeCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11QosFrameDuplicateCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 2 to 9 (dot11QosCountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 67 } dot11RMRqstSTAStatTrigQoSRTSFailCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11QosRTSFailureCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 2 to 9 (dot11QosCountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 68 } dot11RMRqstSTAStatTrigQoSAckFailCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11QosAckFailureCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 2 to 9 (dot11QosCountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 69 } dot11RMRqstSTAStatTrigQoSDiscardCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11QosDiscardedFrameCount value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 2 to 9 (dot11QosCountersTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 70 } dot11RMRqstSTAStatTrigRsnaTrigCondition OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the trigger values used when requesting triggered RSNA STA Statistics reporting. The format of the STA Counter Trigger Condition field is shown in Figure 9-197." ::= { dot11RMRequestEntry 71 } dot11RMRqstSTAStatTrigRsnaCMACICVErrCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11RSNAStatsBIPMICErrors value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 16 (dot11RSNAStatsTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 72 } dot11RMRqstSTAStatTrigRsnaCMACReplayCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11RSNAStatsCMACReplays value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 16 (dot11RSNAStatsTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 73 } dot11RMRqstSTAStatTrigRsnaRobustCCMPReplayCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11RSNAStatsRobustMgmtCCMPReplays value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 16 (dot11RSNAStatsTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 74 } dot11RMRqstSTAStatTrigRsnaTKIPICVErrCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11RSNAStatsTKIPICVErrors value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 16 (dot11RSNAStatsTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 75 } dot11RMRqstSTAStatTrigRsnaTKIPReplayCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11RSNAStatsTKIPReplays value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 16 (dot11RSNAStatsTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 76 } dot11RMRqstSTAStatTrigRsnaCCMPDecryptErrCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11RSNAStatsCCMPDecryptErrors value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 16 (dot11RSNAStatsTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 77 } dot11RMRqstSTAStatTrigRsnaCCMPReplayCntThresh OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates that a STA Statistics report should be generated (triggered) when the dot11RSNAStatsCCMPReplays value has increased more than the threshold value indicated here. The counter increase is measured over the last n MSDUs or MPDUs, where n is the value of dot11RMRqstSTAStatTrigMeasCount. This attribute is valid only if dot11RMRqstType is 7 (STA Statistics), and if dot11RMRqstSTAStatRqstGroupID is 16 (dot11RSNAStatsTable) and if the value of the attribute is not equal to 0." DEFVAL { 0 } ::= { dot11RMRequestEntry 78 } -- ********************************************************************** -- * End of dot11RMRequest TABLE -- ********************************************************************** -- ******************************************************************** -- * Radio Measurement Reports -- * Report tables contain measurement reports received by this STA or -- * results of measurements performed by this STA. -- ******************************************************************** dot11RMReport OBJECT IDENTIFIER ::= { dot11RadioMeasurement 2 } -- ******************************************************************** -- * dot11ChannelLoadReport TABLE -- ******************************************************************** dot11ChannelLoadReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11ChannelLoadReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current list of Channel Load reports that have been received by the MLME. The report tables are maintained as a FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11RMReport 1 } dot11ChannelLoadReportEntry OBJECT-TYPE SYNTAX Dot11ChannelLoadReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11ChannelLoadReportTable Indexed by dot11ChannelLoadRprtIndex." INDEX { dot11ChannelLoadRprtIndex } ::= { dot11ChannelLoadReportTable 1 } Dot11ChannelLoadReportEntry ::= SEQUENCE { dot11ChannelLoadRprtIndex Unsigned32, dot11ChannelLoadRprtRqstToken OCTET STRING, dot11ChannelLoadRprtIfIndex InterfaceIndex, dot11ChannelLoadMeasuringSTAAddr MacAddress, dot11ChannelLoadRprtChanNumber Unsigned32, dot11ChannelLoadRprtOperatingClass Unsigned32, dot11ChannelLoadRprtActualStartTime TSFType, dot11ChannelLoadRprtMeasurementDuration Unsigned32, dot11ChannelLoadRprtChannelLoad Unsigned32, dot11ChannelLoadRprtVendorSpecific OCTET STRING, dot11ChannelLoadRprtMeasurementMode INTEGER } dot11ChannelLoadRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Channel Load report elements in dot11ChannelLoadReportTable, greater than 0." ::= { dot11ChannelLoadReportEntry 1 } dot11ChannelLoadRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the request token that was indicated in the Measurement request that generated this measurement report. This should be an exact match to the original dot11RMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple measurement reports." ::= { dot11ChannelLoadReportEntry 2 } dot11ChannelLoadRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The ifIndex of the interface over which this ChannelLoad Report was received." ::= { dot11ChannelLoadReportEntry 3 } dot11ChannelLoadMeasuringSTAAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The MAC address of the measuring STA for this row of the Channel Load report." ::= { dot11ChannelLoadReportEntry 4 } dot11ChannelLoadRprtChanNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel number used for this Channel Load report. The Channel Number is defined only within the indicated Operating Class for this measurement report." ::= { dot11ChannelLoadReportEntry 5 } dot11ChannelLoadRprtOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel set for this measurement report. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement report. Valid values of Operating Class are shown in Annex E." ::= { dot11ChannelLoadReportEntry 6 } dot11ChannelLoadRprtActualStartTime OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the TSF value at the time when the measurement started." ::= { dot11ChannelLoadReportEntry 7 } dot11ChannelLoadRprtMeasurementDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the duration over which the ChannelLoad Report was measured." ::= { dot11ChannelLoadReportEntry 8 } dot11ChannelLoadRprtChannelLoad OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "1/255" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. Channel Load contains the fractional duration over which the measuring STA determined the channel to be busy during the measurement duration." ::= { dot11ChannelLoadReportEntry 9 } dot11ChannelLoadRprtVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute provides an envelope for any optional vendor specific subelements which may be included in a measurement report element." DEFVAL { ''H } ::= { dot11ChannelLoadReportEntry 10 } dot11ChannelLoadRprtMeasurementMode OBJECT-TYPE SYNTAX INTEGER { success(0), incapableBit(1), refusedBit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the outcome status for the measurement request which generated this measurement report; status is indicated using the following reason codes: 1 indicates this STA is incapable of generating the report, 2 indicates this STA is refusing to generate the report, 0 indicates the STA successfully carried out the measurement request." DEFVAL { 0 } ::= { dot11ChannelLoadReportEntry 11 } -- ******************************************************************** -- * End of dot11ChannelLoadReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11NoiseHistogramReport TABLE -- ******************************************************************** dot11NoiseHistogramReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11NoiseHistogramReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current list of Noise Histogram reports that have been received by the MLME. The report tables are maintained as a FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11RMReport 2 } dot11NoiseHistogramReportEntry OBJECT-TYPE SYNTAX Dot11NoiseHistogramReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11NoiseHistogramReportTable Indexed by dot11NoiseHistogramRprtIndex." INDEX { dot11NoiseHistogramRprtIndex } ::= { dot11NoiseHistogramReportTable 1 } Dot11NoiseHistogramReportEntry ::= SEQUENCE { dot11NoiseHistogramRprtIndex Unsigned32, dot11NoiseHistogramRprtRqstToken OCTET STRING, dot11NoiseHistogramRprtIfIndex InterfaceIndex, dot11NoiseHistogramMeasuringSTAAddr MacAddress, dot11NoiseHistogramRprtChanNumber Unsigned32, dot11NoiseHistogramRprtOperatingClass Unsigned32, dot11NoiseHistogramRprtActualStartTime TSFType, dot11NoiseHistogramRprtMeasurementDuration Unsigned32, dot11NoiseHistogramRprtAntennaID Unsigned32, dot11NoiseHistogramRprtANPI Unsigned32, dot11NoiseHistogramRprtIPIDensity0 Unsigned32, dot11NoiseHistogramRprtIPIDensity1 Unsigned32, dot11NoiseHistogramRprtIPIDensity2 Unsigned32, dot11NoiseHistogramRprtIPIDensity3 Unsigned32, dot11NoiseHistogramRprtIPIDensity4 Unsigned32, dot11NoiseHistogramRprtIPIDensity5 Unsigned32, dot11NoiseHistogramRprtIPIDensity6 Unsigned32, dot11NoiseHistogramRprtIPIDensity7 Unsigned32, dot11NoiseHistogramRprtIPIDensity8 Unsigned32, dot11NoiseHistogramRprtIPIDensity9 Unsigned32, dot11NoiseHistogramRprtIPIDensity10 Unsigned32, dot11NoiseHistogramRprtVendorSpecific OCTET STRING, dot11NoiseHistogramRprtMeasurementMode INTEGER} dot11NoiseHistogramRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Noise Histogram elements in dot11NoiseHistogramReportTable, greater than 0." ::= { dot11NoiseHistogramReportEntry 1 } dot11NoiseHistogramRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the request token that was indicated in the measurement request that generated this measurement report. This should be an exact match to the original dot11RMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple measurement reports." ::= { dot11NoiseHistogramReportEntry 2 } dot11NoiseHistogramRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The ifIndex of the interface over which this Noise Histogram report was received. " ::= { dot11NoiseHistogramReportEntry 3 } dot11NoiseHistogramMeasuringSTAAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The MAC address of the measuring STA for this row of Noise Histogram report." ::= { dot11NoiseHistogramReportEntry 4 } dot11NoiseHistogramRprtChanNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel number used for this Noise Histogram report. The Channel Number is defined only within the indicated Operating Class for this measurement report." ::= { dot11NoiseHistogramReportEntry 5 } dot11NoiseHistogramRprtOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel set for this measurement report. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement report. Valid values of Operating Class are shown in Annex E." ::= { dot11NoiseHistogramReportEntry 6 } dot11NoiseHistogramRprtActualStartTime OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the TSF value at the time when the measurement started." ::= { dot11NoiseHistogramReportEntry 7 } dot11NoiseHistogramRprtMeasurementDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the duration over which the Noise Histogram report was measured." ::= { dot11NoiseHistogramReportEntry 8 } dot11NoiseHistogramRprtAntennaID OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the identifying number for the antenna(s) or DMG antenna(s) used for this measurement." ::= { dot11NoiseHistogramReportEntry 9 } dot11NoiseHistogramRprtANPI OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the Average Noise Power Indicator (ANPI) for this Noise Histogram measurement. The ANPI value represents the average noise plus interference power on the measured channel at the antenna connector during the measurement duration. To calculate ANPI, the STA measures and uses IPI in the indicated channel when NAV is equal to 0 (when virtual CS mechanism indicates idle channel) except during frame transmission or reception." ::= { dot11NoiseHistogramReportEntry 10 } dot11NoiseHistogramRprtIPIDensity0 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: Power <= -92 dBm." ::= { dot11NoiseHistogramReportEntry 11 } dot11NoiseHistogramRprtIPIDensity1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -92 dBm < Power <= -9 dBm." ::= { dot11NoiseHistogramReportEntry 12 } dot11NoiseHistogramRprtIPIDensity2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -89 dBm < Power <= -86 dBm." ::= { dot11NoiseHistogramReportEntry 13 } dot11NoiseHistogramRprtIPIDensity3 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -86 dBm < Power <= -83 dBm." ::= { dot11NoiseHistogramReportEntry 14 } dot11NoiseHistogramRprtIPIDensity4 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -83 dBm < Power <= -80 dBm." ::= { dot11NoiseHistogramReportEntry 15 } dot11NoiseHistogramRprtIPIDensity5 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -80 dBm < Power <= -75 dBm." ::= { dot11NoiseHistogramReportEntry 16 } dot11NoiseHistogramRprtIPIDensity6 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -75 dBm < Power <= -70 dBm." ::= { dot11NoiseHistogramReportEntry 17 } dot11NoiseHistogramRprtIPIDensity7 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -70 dBm < Power <= -65 dBm." ::= { dot11NoiseHistogramReportEntry 18 } dot11NoiseHistogramRprtIPIDensity8 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -65 dBm < Power <= -60 dBm." ::= { dot11NoiseHistogramReportEntry 19 } dot11NoiseHistogramRprtIPIDensity9 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -60 dBm < Power <= -55 dBm." ::= { dot11NoiseHistogramReportEntry 20 } dot11NoiseHistogramRprtIPIDensity10 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measured IPI density for non-IEEE-802.11 signals with measured power satisfying the condition: -55 dBm < Power." ::= { dot11NoiseHistogramReportEntry 21 } dot11NoiseHistogramRprtVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute provides an envelope for any optional vendor specific subelements which may be included in a measurement report element." DEFVAL { ''H } ::= { dot11NoiseHistogramReportEntry 22 } dot11NoiseHistogramRprtMeasurementMode OBJECT-TYPE SYNTAX INTEGER { success(0), incapableBit(1), refusedBit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the outcome status for the measurement request which generated this measurement report; status is indicated using the following reason codes: 1 indicates this STA is incapable of generating the report, 2 indicates this STA is refusing to generate the report, 0 indicates the STA successfully carried out the measurement request." DEFVAL { 0 } ::= { dot11NoiseHistogramReportEntry 23 } -- ******************************************************************** -- * End of dot11NoiseHistogramReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11BeaconReport TABLE -- ******************************************************************** dot11BeaconReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11BeaconReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current list of Beacon reports that have been received by the MLME. The report tables are maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11RMReport 3 } dot11BeaconReportEntry OBJECT-TYPE SYNTAX Dot11BeaconReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11BeaconReportTable Indexed by dot11BeaconRprtIndex." INDEX { dot11BeaconRprtIndex } ::= { dot11BeaconReportTable 1 } Dot11BeaconReportEntry ::= SEQUENCE { dot11BeaconRprtIndex Unsigned32, dot11BeaconRprtRqstToken OCTET STRING, dot11BeaconRprtIfIndex InterfaceIndex, dot11BeaconMeasuringSTAAddr MacAddress, dot11BeaconRprtChanNumber Unsigned32, dot11BeaconRprtOperatingClass Unsigned32, dot11BeaconRprtActualStartTime TSFType, dot11BeaconRprtMeasurementDuration Unsigned32, dot11BeaconRprtPhyType INTEGER, dot11BeaconRprtReportedFrameType INTEGER, dot11BeaconRprtRCPI Unsigned32, dot11BeaconRprtRSNI Unsigned32, dot11BeaconRprtBSSID MacAddress, dot11BeaconRprtAntennaID Unsigned32, dot11BeaconRprtParentTSF TSFType, dot11BeaconRprtReportedFrameBody OCTET STRING, dot11BeaconRprtVendorSpecific OCTET STRING, dot11BeaconRprtMeasurementMode INTEGER} dot11BeaconRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Beacon reports in dot11BeaconReportTable, greater than 0." ::= { dot11BeaconReportEntry 1 } dot11BeaconRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the request token that was indicated in the measurement request that generated this measurement report. This should be an exact match to the original dot11RMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple measurement reports." ::= { dot11BeaconReportEntry 2 } dot11BeaconRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The ifIndex of the interface over which this Beacon report was received." ::= { dot11BeaconReportEntry 3 } dot11BeaconMeasuringSTAAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The MAC address of the measuring STA for this row of Beacon report." ::= { dot11BeaconReportEntry 4 } dot11BeaconRprtChanNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel number used for this Beacon report. The Channel Number is defined only within the indicated Operating Class for this measurement report." ::= { dot11BeaconReportEntry 5 } dot11BeaconRprtOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel set for this measurement report. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement report. Valid values of Operating Class are shown in Annex E." ::= { dot11BeaconReportEntry 6 } dot11BeaconRprtActualStartTime OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the TSF value at the time when the measurement started." ::= { dot11BeaconReportEntry 7 } dot11BeaconRprtMeasurementDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the duration over which the Beacon report was measured." ::= { dot11BeaconReportEntry 8 } dot11BeaconRprtPhyType OBJECT-TYPE SYNTAX INTEGER { dsss(2), ofdm(4), hrdsss(5), erp(6), ht(7), dmg(8), vht(9), tvht(10), s1g(11), cdmg(12), cmmg(13)} MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the PHY Type for this row of Beacon report." ::= { dot11BeaconReportEntry 9 } dot11BeaconRprtReportedFrameType OBJECT-TYPE SYNTAX INTEGER { beaconOrProbeResponse(0), measurementPilot(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the frame type reported in dot11BeaconRprtReportedFrameBody" ::= { dot11BeaconReportEntry 10 } dot11BeaconRprtRCPI OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the received channel power of the PPDU containing a Beacon or Probe Response frame as defined 9.4.2.37. RCPIval = Floor((RCPIpower in dBm + 110)*2), for RCPI in the range -110 dBm to 0 dBm. RCPIval = 220 for RCPI > 0 dBm. RCPIval = 255 when RCPI is not available." ::= { dot11BeaconReportEntry 11 } dot11BeaconRprtRSNI OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the received signal-to-noise ratio of the beacon or Probe Response frame. RSNI is the received signal-to-noise plus interference ratio derived from the measured RCPI for the received frame and from the measured ANPI for the channel used to receive the frame. RSNI is calculated by the ratio of the received signal power (RCPI - ANPI) over the noise plus interference power (ANPI) where RSNI = [(ratio(dB) + 10) * 2], for ratios in the range -10 dB to +118 dB." ::= { dot11BeaconReportEntry 12 } dot11BeaconRprtBSSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the BSSID field of the beacon for this row of Beacon report." ::= { dot11BeaconReportEntry 13 } dot11BeaconRprtAntennaID OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the identifying number for the antenna(s) or DMG antenna used for this measurement." ::= { dot11BeaconReportEntry 14 } dot11BeaconRprtParentTSF OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the TSF value of the serving measuring STA's TSF value at the time the measuring STA received the Beacon or Probe Response frame." ::= { dot11BeaconReportEntry 15 } dot11BeaconRprtReportedFrameBody OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the fields and elements from the frame body of the Beacon, Measurement Pilot or Probe Response frame being received. All reported TIM elements are truncated to 4 octets." ::= { dot11BeaconReportEntry 16 } dot11BeaconRprtVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute provides an envelope for any optional vendor specific subelements which may be included in a measurement report element." DEFVAL { ''H } ::= { dot11BeaconReportEntry 17 } dot11BeaconRprtMeasurementMode OBJECT-TYPE SYNTAX INTEGER { success(0), incapableBit(1), refusedBit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the outcome status for the measurement request which generated this measurement report; status is indicated using the following reason codes: 1 indicates this STA is incapable of generating the report, 2 indicates this STA is refusing to generate the report, 0 indicates the STA successfully carried out the measurement request." DEFVAL { 0 } ::= { dot11BeaconReportEntry 18 } -- ******************************************************************** -- * End of dot11BeaconReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11FrameReport TABLE -- ******************************************************************** dot11FrameReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11FrameReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current list of Frame reports that have been received by the MLME. The report tables are maintained as a FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11RMReport 4 } dot11FrameReportEntry OBJECT-TYPE SYNTAX Dot11FrameReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11FrameReportTable Indexed by dot11FrameRprtIndex." INDEX { dot11FrameRprtIndex } ::= { dot11FrameReportTable 1 } Dot11FrameReportEntry ::= SEQUENCE { dot11FrameRprtIndex Unsigned32, dot11FrameRprtIfIndex InterfaceIndex, dot11FrameRprtRqstToken Unsigned32, dot11FrameRprtChanNumber Unsigned32, dot11FrameRprtOperatingClass Unsigned32, dot11FrameRprtActualStartTime TSFType, dot11FrameRprtMeasurementDuration Unsigned32, dot11FrameRprtTransmitSTAAddress MacAddress, dot11FrameRprtBSSID MacAddress, dot11FrameRprtPhyType INTEGER, dot11FrameRprtAvgRCPI Unsigned32, dot11FrameRprtLastRSNI Unsigned32, dot11FrameRprtLastRCPI Unsigned32, dot11FrameRprtAntennaID Unsigned32, dot11FrameRprtNumberFrames Unsigned32, dot11FrameRprtVendorSpecific OCTET STRING, dot11FrameRptMeasurementMode INTEGER} dot11FrameRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Frame reports in dot11FrameReportTable, greater than 0." ::= { dot11FrameReportEntry 1 } dot11FrameRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The ifIndex of the interface over which this Frame report was received." ::= { dot11FrameReportEntry 2 } dot11FrameRprtRqstToken OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. INDEX for Frame requests in dot11FrameRequestTable that corresponds to this row of frame report. Since a single Frame request can generate multiple rows in the frame report table, one per BSSID, this dot11FrameRprtRqstToken indicates which request this particular row indicates. If this row of report is received without a particular request, this attribute should be 0" ::= { dot11FrameReportEntry 3 } dot11FrameRprtChanNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel number used for this Frame report. The Channel Number is defined only within the indicated Operating Class for this measurement report." ::= { dot11FrameReportEntry 4 } dot11FrameRprtOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel set for this measurement report. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement report. Valid values of Operating Class are shown in Annex E." ::= { dot11FrameReportEntry 5 } dot11FrameRprtActualStartTime OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the TSF value at the time when measurement started." ::= { dot11FrameReportEntry 6 } dot11FrameRprtMeasurementDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the duration over which the Frame report was measured" ::= { dot11FrameReportEntry 7 } dot11FrameRprtTransmitSTAAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The MAC address of STA for this row of Frame report that it has been received from." ::= { dot11FrameReportEntry 8 } dot11FrameRprtBSSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the BSSID of the BSS of the STA that transmitted this frame." ::= { dot11FrameReportEntry 9 } dot11FrameRprtPhyType OBJECT-TYPE SYNTAX INTEGER { dsss(2), ofdm(4), hrdsss(5), erp(6), ht(7), dmg(8), vht(9), tvht(10), s1g(11), cdmg(12), cmmg(13)} MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the PHY used for frame reception in this row of the frame report." ::= { dot11FrameReportEntry 10 } dot11FrameRprtAvgRCPI OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the average value for the received channel power of all of the PPDUs containing the frames received and counted in this frame report entry as defined 9.4.2.37. RCPIval = Floor((RCPIpower in dBm + 110)*2), for RCPI in the range -110 dBm to 0 dBm. RCPIval = 220 for RCPI > 0 dBm. RCPIval = 255 when RCPI is not available." ::= { dot11FrameReportEntry 11 } dot11FrameRprtLastRSNI OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the received signal-to-noise ratio of the received frame. RSNI is the received signal-to-noise plus interference ratio derived from the RCPI for the received frame and from the most recent ANPI value measured on the channel used to receive the frame. RSNI may be calculated by the ratio of the received signal power (RCPI - ANPI) over the noise plus interference power (ANPI) where RSNI = [(ratio(dB) + 10) * 2], for ratios in the range -10 dB to +118 dB. Other measurement techniques are allowed." ::= { dot11FrameReportEntry 12 } dot11FrameRprtLastRCPI OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the received channel power of the most recently measured PPDU containing the frame in this frame report entry as defined 9.4.2.37. RCPIval = Floor((RCPIpower in dBm + 110)*2), for RCPI in the range -110 dBm to 0 dBm. RCPIval = 220 for RCPI > 0 dBm. RCPIval = 255 when RCPI is not available." ::= { dot11FrameReportEntry 13 } dot11FrameRprtAntennaID OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the identifying number for the antenna(s) or DMG antenna used for this measurement." ::= { dot11FrameReportEntry 14 } dot11FrameRprtNumberFrames OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the number of received frames in the Measurement Report frame for this row of the Frame report." ::= { dot11FrameReportEntry 15 } dot11FrameRprtVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute provides an envelope for any optional vendor specific subelements which may be included in a measurement report element." DEFVAL { ''H } ::= { dot11FrameReportEntry 16 } dot11FrameRptMeasurementMode OBJECT-TYPE SYNTAX INTEGER { success(0), incapableBit(1), refusedBit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the outcome status for the measurement request which generated this measurement report; status is indicated using the following reason codes: 1 indicates this STA is incapable of generating the report, 2 indicates this STA is refusing to generate the report, 0 indicates the STA successfully carried out the measurement request." DEFVAL { 0 } ::= { dot11FrameReportEntry 17 } -- ******************************************************************** -- * End of dot11FrameReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11STAStatisticsReport TABLE -- ******************************************************************** dot11STAStatisticsReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11STAStatisticsReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current list of STA Statistics reports that have been received by the MLME. The report tables are maintained as a FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11RMReport 5 } dot11STAStatisticsReportEntry OBJECT-TYPE SYNTAX Dot11STAStatisticsReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11STAStatisticsReportTable Indexed by dot11STAStatisticsReportIndex." INDEX { dot11STAStatisticsReportIndex } ::= { dot11STAStatisticsReportTable 1 } Dot11STAStatisticsReportEntry ::= SEQUENCE { dot11STAStatisticsReportIndex Unsigned32, dot11STAStatisticsReportToken OCTET STRING, dot11STAStatisticsIfIndex InterfaceIndex, dot11STAStatisticsSTAAddress MacAddress, dot11STAStatisticsMeasurementDuration Unsigned32, dot11STAStatisticsGroupID INTEGER, dot11STAStatisticsTransmittedFragmentCount Counter32, dot11STAStatisticsGroupTransmittedFrameCount Counter32, dot11STAStatisticsFailedCount Counter32, dot11STAStatisticsRetryCount Counter32, dot11STAStatisticsMultipleRetryCount Counter32, dot11STAStatisticsFrameDuplicateCount Counter32, dot11STAStatisticsRTSSuccessCount Counter32, dot11STAStatisticsRTSFailureCount Counter32, dot11STAStatisticsAckFailureCount Counter32, dot11STAStatisticsQosTransmittedFragmentCount Counter32, dot11STAStatisticsQosFailedCount Counter32, dot11STAStatisticsQosRetryCount Counter32, dot11STAStatisticsQosMultipleRetryCount Counter32, dot11STAStatisticsQosFrameDuplicateCount Counter32, dot11STAStatisticsQosRTSSuccessCount Counter32, dot11STAStatisticsQosRTSFailureCount Counter32, dot11STAStatisticsQosAckFailureCount Counter32, dot11STAStatisticsQosReceivedFragmentCount Counter32, dot11STAStatisticsQosTransmittedFrameCount Counter32, dot11STAStatisticsQosDiscardedFrameCount Counter32, dot11STAStatisticsQosMPDUsReceivedCount Counter32, dot11STAStatisticsQosRetriesReceivedCount Counter32, dot11STAStatisticsReceivedFragmentCount Counter32, dot11STAStatisticsGroupReceivedFrameCount Counter32, dot11STAStatisticsFCSErrorCount Counter32, dot11STAStatisticsTransmittedFrameCount Counter32, dot11STAStatisticsAPAverageAccessDelay Unsigned32, dot11STAStatisticsAverageAccessDelayBestEffort Unsigned32, dot11STAStatisticsAverageAccessDelayBackground Unsigned32, dot11STAStatisticsAverageAccessDelayVideo Unsigned32, dot11STAStatisticsAverageAccessDelayVoice Unsigned32, dot11STAStatisticsStationCount Integer32, dot11STAStatisticsChannelUtilization Unsigned32, dot11STAStatisticsVendorSpecific OCTET STRING, dot11STAStatisticsRprtMeasurementMode INTEGER, dot11STAStatisticsRSNAStatsBIPMICErrors Counter32, dot11STAStatisticsRSNAStatsCMACReplays Counter32, dot11STAStatisticsRSNAStatsRobustMgmtCCMPReplays Counter32, dot11STAStatisticsRSNAStatsTKIPICVErrors Counter32, dot11STAStatisticsRSNAStatsTKIPReplays Counter32, dot11STAStatisticsRSNAStatsCCMPDecryptErrors Counter32, dot11STAStatisticsRSNAStatsCCMPReplays Counter32, dot11STAStatisticsReportingReasonSTACounters OCTET STRING, dot11STAStatisticsReportingReasonQosCounters OCTET STRING, dot11STAStatisticsReportingReasonRsnaCounters OCTET STRING, dot11STAStatisticsTransmittedAMSDUCount Counter32, dot11STAStatisticsFailedAMSDUCount Counter32, dot11STAStatisticsRetryAMSDUCount Counter32, dot11STAStatisticsMultipleRetryAMSDUCount Counter32, dot11STAStatisticsTransmittedOctetsInAMSDUCount Counter64, dot11STAStatisticsAMSDUAckFailureCount Counter32, dot11STAStatisticsReceivedAMSDUCount Counter32, dot11STAStatisticsReceivedOctetsInAMSDUCount Counter64, dot11STAStatisticsTransmittedAMPDUCount Counter32, dot11STAStatisticsTransmittedMPDUsInAMPDUCount Counter32, dot11STAStatisticsTransmittedOctetsInAMPDUCount Counter64, dot11STAStatisticsAMPDUReceivedCount Counter32, dot11STAStatisticsMPDUInReceivedAMPDUCount Counter32, dot11STAStatisticsReceivedOctetsInAMPDUCount Counter64, dot11STAStatisticsAMPDUDelimiterCRCErrorCount Counter32, dot11STAStatisticsImplicitBARFailureCount Counter32, dot11STAStatisticsExplicitBARFailureCount Counter32, dot11STAStatisticsChannelWidthSwitchCount Counter32, dot11STAStatisticsTwentyMHzFrameTransmittedCount Counter32, dot11STAStatisticsFortyMHzFrameTransmittedCount Counter32, dot11STAStatisticsTwentyMHzFrameReceivedCount Counter32, dot11STAStatisticsFortyMHzFrameReceivedCount Counter32, dot11STAStatisticsPSMPUTTGrantDuration Counter32, dot11STAStatisticsPSMPUTTUsedDuration Counter32, dot11STAStatisticsGrantedRDGUsedCount Counter32, dot11STAStatisticsGrantedRDGUnusedCount Counter32, dot11STAStatisticsTransmittedFramesInGrantedRDGCount Counter32, dot11STAStatisticsTransmittedOctetsInGrantedRDGCount Counter64, dot11STAStatisticsDualCTSSuccessCount Counter32, dot11STAStatisticsDualCTSFailureCount Counter32, dot11STAStatisticsBeamformingFrameCount Counter32, dot11STAStatisticsSTBCCTSSuccessCount Counter32, dot11STAStatisticsSTBCCTSFailureCount Counter32, dot11STAStatisticsnonSTBCCTSSuccessCount Counter32, dot11STAStatisticsnonSTBCCTSFailureCount Counter32, dot11STAStatisticsAverageMSDUSizeVideo Unsigned32, dot11STAStatisticsAverageMSDUSizeVoice Unsigned32, dot11STAStatisticsAverageBitrateVideo Unsigned32, dot11STAStatisticsAverageBitrateVoice Unsigned32 } dot11STAStatisticsReportIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for STA Statistics reports in dot11STAStatisticsReportTable, greater than 0." ::= { dot11STAStatisticsReportEntry 1 } dot11STAStatisticsReportToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the token that was indicated in the measurement request that generated this measurement report. This should be an exact match to the original dot11RMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple measurement reports." ::= { dot11STAStatisticsReportEntry 2 } dot11STAStatisticsIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. Identifies the Interface that this row of STA Statistics report has been received on" ::= { dot11STAStatisticsReportEntry 3 } dot11STAStatisticsSTAAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The MAC address of the STA that returned this STA Statistics report." ::= { dot11STAStatisticsReportEntry 4 } dot11STAStatisticsMeasurementDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the duration over which the STA Statistics was measured. The value 0 for this attribute indicates that the reported statistics are a current snapshot of the statistics variables. A nonzero value for this attribute indicates that the reported statistics contain the difference in the corresponding statistics variables over the indicated duration." ::= { dot11STAStatisticsReportEntry 5 } dot11STAStatisticsGroupID OBJECT-TYPE SYNTAX INTEGER { dot11CountersTable(0), dot11MacStatistics(1), dot11QosCountersTableforUP0(2), dot11QosCountersTableforUP1(3), dot11QosCountersTableforUP2(4), dot11QosCountersTableforUP3(5), dot11QosCountersTableforUP4(6), dot11QosCountersTableforUP5(7), dot11QosCountersTableforUP6(8), dot11QosCountersTableforUP7(9), bSSAverageAccessDelays(10), dot11CountersGroup3Tablefor31(11), dot11CountersGroup3Tablefor32(12), dot11CountersGroup3Tablefor33(13), dot11CountersGroup3Tablefor34(14), dot11CountersGroup3Tablefor35(15), dot11RSNAStatsTable(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the value of dot11RMRqstSTAStatRqstGroupID returned from the STA in this STA Statistics report." DEFVAL { 0 } ::= { dot11STAStatisticsReportEntry 6 } dot11STAStatisticsTransmittedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11TransmittedFragmentCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 0 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 7 } dot11STAStatisticsGroupTransmittedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11GroupTransmittedFrameCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 0 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 8 } dot11STAStatisticsFailedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11FailedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 0 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 9 } dot11STAStatisticsRetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RetryCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 1 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 10 } dot11STAStatisticsMultipleRetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11MultipleRetryCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 1 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 11 } dot11STAStatisticsFrameDuplicateCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11FrameDuplicateCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 1 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 12 } dot11STAStatisticsRTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RTSSuccessCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 1 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 13 } dot11STAStatisticsRTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RTSFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 1 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 14 } dot11STAStatisticsAckFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11AckFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 1 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 15 } dot11STAStatisticsQosTransmittedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosTransmittedFragmentCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 16 } dot11STAStatisticsQosFailedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosFailedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 17 } dot11STAStatisticsQosRetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosRetryCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 18 } dot11STAStatisticsQosMultipleRetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosMultipleRetryCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 19 } dot11STAStatisticsQosFrameDuplicateCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosFrameDuplicateCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 20 } dot11STAStatisticsQosRTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosRTSSuccessCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 21 } dot11STAStatisticsQosRTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosRTSFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 22 } dot11STAStatisticsQosAckFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosAckFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 23 } dot11STAStatisticsQosReceivedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosReceivedFragmentCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 24 } dot11STAStatisticsQosTransmittedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosTransmittedFrameCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 25 } dot11STAStatisticsQosDiscardedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosDiscardedFrameCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 26 } dot11STAStatisticsQosMPDUsReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosMPDUsReceivedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 27 } dot11STAStatisticsQosRetriesReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11QosRetriesReceivedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 28 } dot11STAStatisticsReceivedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11ReceivedFragmentCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 0 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 29 } dot11STAStatisticsGroupReceivedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11GroupReceivedFrameCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 0 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 30 } dot11STAStatisticsFCSErrorCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11FCSErrorCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 0 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 31 } dot11STAStatisticsTransmittedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11TransmittedFrameCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 0 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 32 } dot11STAStatisticsAPAverageAccessDelay OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of the AP Average Access Delay (AAD) returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced access delay value over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 10 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 33 } dot11STAStatisticsAverageAccessDelayBestEffort OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of the Average Access Delay (AAD) for the Best Effort Access Category returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced access delay value over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 10 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 34 } dot11STAStatisticsAverageAccessDelayBackground OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of the Average Access Delay (AAD) for the Background Access Category returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced access delay value over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 10 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 35 } dot11STAStatisticsAverageAccessDelayVideo OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of the Average Access Delay (AAD) for the Video Access Category returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced access delay value over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 10 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 36 } dot11STAStatisticsAverageAccessDelayVoice OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of the Average Access Delay (AAD) for the Voice Access Category returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced access delay value over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 10 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 37 } dot11STAStatisticsStationCount OBJECT-TYPE SYNTAX Integer32 (-255..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11AssociatedStationCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 10 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 38 } dot11STAStatisticsChannelUtilization OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "1/255" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of the Channel Utilization returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the Channel Utilization value over the indicated duration. The Channel Utilization is the time fraction during which the AP sensed the channel busy. This attribute is valid only if the dot11STAStatisticsGroupID is 10 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 39 } dot11STAStatisticsVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute provides an envelope for any optional vendor specific subelements which may be included in a measurement report element." DEFVAL { ''H } ::= { dot11STAStatisticsReportEntry 40 } dot11STAStatisticsRprtMeasurementMode OBJECT-TYPE SYNTAX INTEGER { success(0), incapableBit(1), refusedBit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the outcome status for the measurement request which generated this measurement report; status is indicated using the following reason codes: 1 indicates this STA is incapable of generating the report, 2 indicates this STA is refusing to generate the report, 0 indicates the STA successfully carried out the measurement request." DEFVAL { 0 } ::= { dot11STAStatisticsReportEntry 41 } dot11STAStatisticsRSNAStatsBIPMICErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RSNAStatsBIPMICErrors returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 16 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 42 } dot11STAStatisticsRSNAStatsCMACReplays OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RSNAStatsCMACReplays returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 16 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 43 } dot11STAStatisticsRSNAStatsRobustMgmtCCMPReplays OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RSNAStatsRobustMgmtCCMPReplays returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 16 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 44 } dot11STAStatisticsRSNAStatsTKIPICVErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RSNAStatsTKIPICVErrors returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 16 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 45 } dot11STAStatisticsRSNAStatsTKIPReplays OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RSNAStatsTKIPReplays returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 16 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 46 } dot11STAStatisticsRSNAStatsCCMPDecryptErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RSNAStatsCCMPDecryptErrors returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 16 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 47 } dot11STAStatisticsRSNAStatsCCMPReplays OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is 0, this attribute indicates the value of dot11RSNAStatsCCMPReplays returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 16 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 48 } dot11STAStatisticsReportingReasonSTACounters OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the trigger reason(s) for this Statistics report. Each bit indicates a different trigger condition. When the bit is set to 1, it indicates that the listed trigger threshold has been exceeded: B0 (least significant bit): dot11Failed, B1: dot11FCSError, B2: dot11MultipleRetry, B3: dot11FrameDuplicate, B4: dot11RTSFailure, B5: dot11AckFailureCount, B6: dot11Retry, B7: Reserved. This attribute is valid only if the dot11STAStatisticsGroupID is 0 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 49 } dot11STAStatisticsReportingReasonQosCounters OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the trigger reason(s) for this Statistics report. Each bit indicates a different trigger condition. When the bit is set to 1, it indicates that the listed trigger threshold has been exceeded: B0 (least significant bit): dot11QoSFailed, B1: dot11QoSRetry, B2: dot11QoSMultipleRetry, B3: dot11QoSFrameDuplicate, B4: dot11QoSRTSFailure, B5: dot11QoSAckFailure, B6: dot11QoSDiscarded, B7: Reserved. This attribute is valid only if the dot11STAStatisticsGroupID is 2-9 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 50 } dot11STAStatisticsReportingReasonRsnaCounters OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the trigger reason(s) for this Statistics report. Each bit indicates a different trigger condition. When the bit is set to 1, it indicates that the listed trigger threshold has been exceeded: B0 (least significant bit): dot11RSNAStatsBIPMICErrors, B1: dot11RSNAStatsCMACReplays, B2: dot11RSNAStatsRobustMgmtCCMPReplays, B3: dot11RSNAStatsTKIPICVErrors, B4: dot11RSNAStatsCCMPReplays, B5: dot11RSNAStatsCCMPDecryptErrors, B6: dot11RSNAStatsCCMPReplays, B7: Reserved. This attribute is valid only if the dot11STAStatisticsGroupID is 16 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 51 } dot11STAStatisticsTransmittedAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11TransmittedAMSDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 11 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 52 } dot11STAStatisticsFailedAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11FailedAMSDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 11 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 53 } dot11STAStatisticsRetryAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11RetryAMSDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 11 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 54 } dot11STAStatisticsMultipleRetryAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11MultipleRetryAMSDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 11 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 55 } dot11STAStatisticsTransmittedOctetsInAMSDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11TransmittedOctetsInAMSDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 11 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 56 } dot11STAStatisticsAMSDUAckFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11AMSDUAckFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 11 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 57 } dot11STAStatisticsReceivedAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11ReceivedAMSDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 11 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 58 } dot11STAStatisticsReceivedOctetsInAMSDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11ReceivedOctetsInAMSDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 11 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 59 } dot11STAStatisticsTransmittedAMPDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11TransmittedAMPDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 12 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 60 } dot11STAStatisticsTransmittedMPDUsInAMPDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11TransmittedMPDUsInAMPDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 12 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 61 } dot11STAStatisticsTransmittedOctetsInAMPDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11TransmittedOctetsInAMPDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 12 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 62 } dot11STAStatisticsAMPDUReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11AMPDUReceivedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 12 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 63 } dot11STAStatisticsMPDUInReceivedAMPDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11MPDUInReceivedAMPDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 12 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 64 } dot11STAStatisticsReceivedOctetsInAMPDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11ReceivedOctetsInAMPDUCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 12 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 65 } dot11STAStatisticsAMPDUDelimiterCRCErrorCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11AMPDUDelimiterCRCErrorCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 12 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 66 } dot11STAStatisticsImplicitBARFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11ImplicitBARFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 13 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 67 } dot11STAStatisticsExplicitBARFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11ExplicitBARFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 13 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 68 } dot11STAStatisticsChannelWidthSwitchCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11ChannelWidthSwitchCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 13 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 69 } dot11STAStatisticsTwentyMHzFrameTransmittedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11TwentyMHzFrameTransmittedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 13 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 70 } dot11STAStatisticsFortyMHzFrameTransmittedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11FortyMHzFrameTransmittedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 13 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 71 } dot11STAStatisticsTwentyMHzFrameReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11TwentyMHzFrameReceivedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 13 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 72 } dot11STAStatisticsFortyMHzFrameReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11FortyMHzFrameReceivedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 13 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 73 } dot11STAStatisticsPSMPUTTGrantDuration OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11PSMPUTTGrantDuration returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 13 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 74 } dot11STAStatisticsPSMPUTTUsedDuration OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11PSMPUTTUsedDuration returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 13 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 75 } dot11STAStatisticsGrantedRDGUsedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11GrantedRDGUsedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 14 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 76 } dot11STAStatisticsGrantedRDGUnusedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11GrantedRDGUnusedCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 14 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 77 } dot11STAStatisticsTransmittedFramesInGrantedRDGCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11TransmittedFramesInGrantedRDGCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 14 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 78 } dot11STAStatisticsTransmittedOctetsInGrantedRDGCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11TransmittedOctetsInGrantedRDGCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 14 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 79 } dot11STAStatisticsDualCTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11DualCTSSuccessCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 14 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 80 } dot11STAStatisticsDualCTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11DualCTSFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 14 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 81 } dot11STAStatisticsBeamformingFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11BeamformingFrameCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 15 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 84 } dot11STAStatisticsSTBCCTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11STBCCTSSuccessCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 15 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 85 } dot11STAStatisticsSTBCCTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11STBCCTSFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 15 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 86 } dot11STAStatisticsnonSTBCCTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11nonSTBCCTSSuccessCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 15 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 87 } dot11STAStatisticsnonSTBCCTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of dot11nonSTBCCTSFailureCount returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced dot11 variable over the indicated duration. This attribute is valid only if the dot11STAStatisticsGroupID is 15 and is ignored otherwise." ::= { dot11STAStatisticsReportEntry 88 } dot11STAStatisticsAverageMSDUSizeVideo OBJECT-TYPE SYNTAX Unsigned32 (0..7935) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed or by an external management entity. Changes from an external management entity take effect as soon as practical in the implementation. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of the Average MSDU size for the Video Access Category returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced size over the indicated duration. Changes by an external management entity are ignored when dot11STAStatisticsMeasurementDuration is nonzero." DEFVAL { 1401 } ::= { dot11STAStatisticsReportEntry 89 } dot11STAStatisticsAverageMSDUSizeVoice OBJECT-TYPE SYNTAX Unsigned32 (0..7935) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed or by an external management entity. Changes from an external management entity take effect as soon as practical in the implementation. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of the Average MSDU size for the Voice Access Category returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced size over the indicated duration. Changes by an external management entity are ignored when dot11STAStatisticsMeasurementDuration is nonzero." DEFVAL { 365 } ::= { dot11STAStatisticsReportEntry 90 } dot11STAStatisticsAverageBitrateVideo OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed or by an external management entity. Changes from an external management entity take effect as soon as practical in the implementation. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of the Average PHY bit rate of MPDUs transmitted and received using the Video Access Category returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced size over the indicated duration. Changes by an external management entity are ignored when dot11STAStatisticsMeasurementDuration is nonzero." ::= { dot11STAStatisticsReportEntry 91 } dot11STAStatisticsAverageBitrateVoice OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed or by an external management entity. Changes from an external management entity take effect as soon as practical in the implementation. If dot11STAStatisticsMeasurementDuration is zero, this attribute indicates the value of the Average PHY bit rate of MPDUs transmitted and received using the Voice Access Category returned from the STA in this STA Statistics report. If dot11STAStatisticsMeasurementDuration indicates a nonzero value, this attribute indicates the difference in the referenced size over the indicated duration. Changes by an external management entity are ignored when dot11STAStatisticsMeasurementDuration is nonzero." ::= { dot11STAStatisticsReportEntry 92 } -- ******************************************************************** -- * End of dot11STAStatisticsReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11LCIReport TABLE -- ******************************************************************** dot11LCIReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11LCIReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current list of LCI reports that have been received by the MLME. The report tables are maintained as a FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11RMReport 6 } dot11LCIReportEntry OBJECT-TYPE SYNTAX Dot11LCIReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11LCIReportTable Indexed by dot11LCIReportIndex." INDEX { dot11LCIReportIndex } ::= { dot11LCIReportTable 1 } Dot11LCIReportEntry ::= SEQUENCE { dot11LCIReportIndex Unsigned32, dot11LCIReportToken OCTET STRING, dot11LCIIfIndex InterfaceIndex, dot11LCISTAAddress MacAddress, dot11LCILatitudeUncertainty Unsigned32, dot11LCILatitudeInteger Integer32, dot11LCILatitudeFraction Integer32, dot11LCILongitudeUncertainty Unsigned32, dot11LCILongitudeInteger Integer32, dot11LCILongitudeFraction Integer32, dot11LCIAltitudeType INTEGER, dot11LCIAltitudeUncertainty Unsigned32, dot11LCIAltitude Integer32, dot11LCIDatum Unsigned32, dot11LCIAzimuthType INTEGER, dot11LCIAzimuthResolution Unsigned32, dot11LCIAzimuth Integer32, dot11LCIVendorSpecific OCTET STRING, dot11LCIRprtMeasurementMode INTEGER} dot11LCIReportIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for LCI reports in dot11LCIReportTable, greater than 0." ::= { dot11LCIReportEntry 1 } dot11LCIReportToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the token that was indicated in the measurement request that generated this measurement report. This should be an exact match to the original dot11RMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple measurement reports." ::= { dot11LCIReportEntry 2 } dot11LCIIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. Identifies the Interface that this row of LCI report has been received on" ::= { dot11LCIReportEntry 3 } dot11LCISTAAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The MAC address of the STA that returned this LCI report." ::= { dot11LCIReportEntry 4 } dot11LCILatitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the latitude uncertainty as 6 bits." ::= { dot11LCIReportEntry 5 } dot11LCILatitudeInteger OBJECT-TYPE SYNTAX Integer32 (-359..359) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the latitude as a 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of Latitude." ::= { dot11LCIReportEntry 6 } dot11LCILatitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the latitude as a 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of Latitude." ::= { dot11LCIReportEntry 7 } dot11LCILongitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the longitude uncertainty as 6 bits." ::= { dot11LCIReportEntry 8 } dot11LCILongitudeInteger OBJECT-TYPE SYNTAX Integer32 (-359..359) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the longitude as a 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of Longitude." ::= { dot11LCIReportEntry 9 } dot11LCILongitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the longitude as a 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of Longitude." ::= { dot11LCIReportEntry 10 } dot11LCIAltitudeType OBJECT-TYPE SYNTAX INTEGER { meters(1), floors(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the altitude Type. Codes defined are: meters : in 2s complement fixed-point 22-bit integer part with 8-bit fraction floors : in 2s complement fixed-point 22-bit integer part with 8-bit fraction. " ::= { dot11LCIReportEntry 11 } dot11LCIAltitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the altitude resolution as 6 bits indicating the number of valid bits in the altitude." ::= { dot11LCIReportEntry 12 } dot11LCIAltitude OBJECT-TYPE SYNTAX Integer32 (-536870912..536870911) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the altitude as a 30-bit value defined by the Altitude type field. The field is encoded as a 2s complement fixed-point 22-bit integer part with 8-bit fraction." ::= { dot11LCIReportEntry 13 } -- reserved: 14. Was dot11LCIAltitudeFraction. dot11LCIDatum OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the datum as an 8-bit value encoding the horizontal and vertical references used for the coordinates given in this LCI." ::= { dot11LCIReportEntry 15 } dot11LCIAzimuthType OBJECT-TYPE SYNTAX INTEGER { frontSurfaceOfSTA(0), radioBeam(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the azimuth Type as a one bit attribute encoding the type of Azimuth. Codes defined are: front surface of STA : in 2s complement fixed-point 9-bit integer; and radio beam : in 2s complement fixed-point 9-bit integer" ::= { dot11LCIReportEntry 16 } dot11LCIAzimuthResolution OBJECT-TYPE SYNTAX Unsigned32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the azimuth Resolution as 4 bits indicating the number of valid bits in the azimuth." ::= { dot11LCIReportEntry 17 } dot11LCIAzimuth OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the azimuth as a 9-bit value defined by the Azimuth Type field.The field is encoded as a 2s complement fixed-point 9-bit integer horizontal angle in degrees from true north." ::= { dot11LCIReportEntry 18 } dot11LCIVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute provides an envelope for any optional vendor specific subelements which may be included in a measurement report element." DEFVAL { ''H } ::= { dot11LCIReportEntry 19 } dot11LCIRprtMeasurementMode OBJECT-TYPE SYNTAX INTEGER { success(0), incapableBit(1), refusedBit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the outcome status for the measurement request which generated this measurement report; status is indicated using the following reason codes: 1 indicates this STA is incapable of generating the report, 2 indicates this STA is refusing to generate the report, 0 indicates the STA successfully carried out the measurement request." DEFVAL { 0 } ::= { dot11LCIReportEntry 20 } -- ******************************************************************** -- * End of dot11LCIReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11TransmitStreamReport TABLE -- ******************************************************************** dot11TransmitStreamReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11TransmitStreamReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current list of Transmit Delay Metrics reports that have been received by the MLME. The report tables are maintained as a FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11RMReport 7 } dot11TransmitStreamReportEntry OBJECT-TYPE SYNTAX Dot11TransmitStreamReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11TransmitStreamReportTable Indexed by dot11TransmitStreamRprtIndex." INDEX { dot11TransmitStreamRprtIndex } ::= { dot11TransmitStreamReportTable 1 } Dot11TransmitStreamReportEntry ::= SEQUENCE { dot11TransmitStreamRprtIndex Unsigned32, dot11TransmitStreamRprtRqstToken OCTET STRING, dot11TransmitStreamRprtIfIndex InterfaceIndex, dot11TransmitStreamMeasuringSTAAddr MacAddress, dot11TransmitStreamRprtActualStartTime TSFType, dot11TransmitStreamRprtMeasurementDuration Unsigned32, dot11TransmitStreamRprtPeerSTAAddress MacAddress, dot11TransmitStreamRprtTID Unsigned32, dot11TransmitStreamRprtAverageQueueDelay Unsigned32, dot11TransmitStreamRprtAverageTransmitDelay Unsigned32, dot11TransmitStreamRprtTransmittedMSDUCount Unsigned32, dot11TransmitStreamRprtMSDUDiscardedCount Unsigned32, dot11TransmitStreamRprtMSDUFailedCount Unsigned32, dot11TransmitStreamRprtMultipleRetryCount Unsigned32, dot11TransmitStreamRprtCFPollsLostCount Unsigned32, dot11TransmitStreamRprtBin0Range Unsigned32, dot11TransmitStreamRprtDelayHistogram OCTET STRING, dot11TransmitStreamRprtReason INTEGER, dot11TransmitStreamRprtVendorSpecific OCTET STRING, dot11TransmitStreamRprtMeasurementMode INTEGER} dot11TransmitStreamRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Transmit Delay Metrics Report elements in dot11TransmitStreamReportTable, greater than 0." ::= { dot11TransmitStreamReportEntry 1 } dot11TransmitStreamRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the request token that was indicated in the measurement request that generated this measurement report. This should be an exact match to the original dot11RMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple measurement reports." ::= { dot11TransmitStreamReportEntry 2 } dot11TransmitStreamRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The ifIndex of the interface on which this TransmitStream Report was received." ::= { dot11TransmitStreamReportEntry 3 } dot11TransmitStreamMeasuringSTAAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The MAC address of the measuring STA for this row of Transmit Delay Metrics report." ::= { dot11TransmitStreamReportEntry 4 } dot11TransmitStreamRprtActualStartTime OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the TSF value at the time when the measurement started or for a triggered Transmit Stream/Category Measurement report the TSF value at the reporting QoS STA when the trigger condition was met." ::= { dot11TransmitStreamReportEntry 5 } dot11TransmitStreamRprtMeasurementDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the duration over which the Transmit Delay Metrics Report was measured. In a triggered Transmit Stream/Category Measurement report, metrics are reported over a number of transmitted MSDUs rather than a duration, hence Measurement Duration is equal to 0." ::= { dot11TransmitStreamReportEntry 6 } dot11TransmitStreamRprtPeerSTAAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The MAC address present in the Address 1 field of the measured Data frames for this row of Transmit Stream/Category Measurement report." ::= { dot11TransmitStreamReportEntry 7 } dot11TransmitStreamRprtTID OBJECT-TYPE SYNTAX Unsigned32 (0..16) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the TC or TS for which traffic is to be measured. Values 0 to 15 are defined. Values 16-255 are reserved." ::= { dot11TransmitStreamReportEntry 8 } dot11TransmitStreamRprtAverageQueueDelay OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the average delay of the frames (MSDUs) that are passed to the MAC during the measurement duration for the indicated destination and the indicated Traffic Identifier. Queue Delay is measured from the time the MSDU is passed to the MAC until the transmission starts." ::= { dot11TransmitStreamReportEntry 9 } dot11TransmitStreamRprtAverageTransmitDelay OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the average delay of the frames (MSDUs) that are successfully transmitted during the measurement duration for the indicated destination and the indicated Traffic Identifier. Delay is measured from the time the MSDU is passed to the MAC until the Ack frame is received from the intermediate destination." ::= { dot11TransmitStreamReportEntry 10} dot11TransmitStreamRprtTransmittedMSDUCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the number of MSDUs to the peer STA for the TC, or TS given by the Traffic Identifier successfully transmitted in the measurement duration." ::= {dot11TransmitStreamReportEntry 11} dot11TransmitStreamRprtMSDUDiscardedCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the number of MSDUs to the peer STA for the TC, or TS given by the Traffic Identifier discarded due either to the number of transmit attempts exceeding dot11ShortRetryLimit as appropriate, or due to the MSDU lifetime having been reached." ::= {dot11TransmitStreamReportEntry 12} dot11TransmitStreamRprtMSDUFailedCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the number of MSDUs to the peer STA for the TC, or TS given by the Traffic Identifier discarded during the measurement duration due to the number of transmit attempts exceeding dot11ShortRetryLimit as appropriate." ::= {dot11TransmitStreamReportEntry 13} dot11TransmitStreamRprtMultipleRetryCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the number of MSDUs for the TC, or TS given by the Traffic Identifier that are successfully transmitted after more than one retransmission attempt." ::= {dot11TransmitStreamReportEntry 14} dot11TransmitStreamRprtCFPollsLostCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the number of QoS (+)CF-Poll frames transmitted to the peer STA where there was no response from the QoS STA." ::= {dot11TransmitStreamReportEntry 15} dot11TransmitStreamRprtBin0Range OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the delay range for Bin 0 of the delay histogram." ::= { dot11TransmitStreamReportEntry 16 } dot11TransmitStreamRprtDelayHistogram OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the histogram of delay of the frames (MSDUs) that are successfully transmitted during the measurement duration for the indicated Traffic Identifier and the indicated destination. Delay is measured from the time the MSDU is passed to the MAC until the Ack frame is received from the intermediate destination, in units of TUs." ::= { dot11TransmitStreamReportEntry 17 } dot11TransmitStreamRprtReason OBJECT-TYPE SYNTAX INTEGER { averageTrigger(0), consecutiveTrigger(1), delayTrigger(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the Reason field indicating the reason that the measuring QoS STA sent the Transmit Stream/Category measurement report." DEFVAL { 0 } ::= { dot11TransmitStreamReportEntry 18 } dot11TransmitStreamRprtVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute provides an envelope for any optional vendor specific subelements which may be included in a measurement report element." DEFVAL { ''H } ::= { dot11TransmitStreamReportEntry 19 } dot11TransmitStreamRprtMeasurementMode OBJECT-TYPE SYNTAX INTEGER { success(0), incapableBit(1), refusedBit(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the outcome status for the measurement request which generated this measurement report; status is indicated using the following reason codes: 1 indicates this STA is incapable of generating the report, 2 indicates this STA is refusing to generate the report, 0 indicates the STA successfully carried out the measurement request." DEFVAL { 0 } ::= { dot11TransmitStreamReportEntry 20 } -- ******************************************************************** -- * End of dot11TransmitStreamReport TABLE -- ******************************************************************** -- ******************************************************************** -- * Radio Measurement Configuration Information -- ******************************************************************** dot11RMConfig OBJECT IDENTIFIER ::= { dot11RadioMeasurement 3 } -- ******************************************************************** -- * dot11APChannelReport TABLE -- ******************************************************************** dot11APChannelReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11APChannelReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "AP Channel Report information, in tabular form." ::= { dot11RMConfig 1 } dot11APChannelReportEntry OBJECT-TYPE SYNTAX Dot11APChannelReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11APChannelReportTable. Each entry in the table is indexed by dot11APChannelReportIndex." INDEX { dot11APChannelReportIndex } ::= { dot11APChannelReportTable 1 } Dot11APChannelReportEntry ::= SEQUENCE { dot11APChannelReportIndex Unsigned32, dot11APChannelReportIfIndex InterfaceIndex, dot11APChannelReportOperatingClass Unsigned32, dot11APChannelReportChannelList OCTET STRING} dot11APChannelReportIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for AP channel report entry in dot11APChannelReportTable, greater than 0." ::= { dot11APChannelReportEntry 1 } dot11APChannelReportIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The ifIndex for this row of the AP channel report." ::= { dot11APChannelReportEntry 2 } dot11APChannelReportOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel set for this AP Channel report. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement report. Valid values of Operating Class are shown in Annex E." ::= { dot11APChannelReportEntry 3 } dot11APChannelReportChannelList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute lists the specific channels in this AP Channel report. Each octet indicates a different channel within the indicated Operating Class. This list of channels is the Channel List field in the AP Channel Report element described in 9.4.2.35. " DEFVAL { ''H } ::= { dot11APChannelReportEntry 4 } -- ******************************************************************** -- * End of dot11APChannelReportTable TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11RMNeighborReport TABLE -- ******************************************************************** dot11RMNeighborReportNextIndex OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies the next available index for managing the neighbor report table. If this attribute is 0, it indicates that the neighbor report feature is not configurable via SNMP, or the table is full and new rows cannot be accepted." ::= { dot11RMConfig 2 } dot11RMNeighborReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RMNeighborReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains pertinent information on a collection of BSSIDs that are candidates to which STAs can roam. The rows are created using createAndWait method and fill in the attributes. When the rowStatus is set to active, the row can be included in Neighbor Report elements. If there is an error, the rowStatus is set to notReady by SME. Since this table contains all Neighbor Report element entries for all interfaces enabled with the neighbor report feature, it is possible to have too many entries for one interface, while still remaining under the MaxTableSize. In that situation, SME includes neighbor report entries only with lower dot11RMNeighborReportIFIndex up to the maximum possible number of entries for a particular interface identified by ifIndex. SME sets the rowStatus to notInService for those rows that cannot be included in the Neighbor Report element for that interface." ::= { dot11RMConfig 3 } dot11RMNeighborReportEntry OBJECT-TYPE SYNTAX Dot11RMNeighborReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11RMNeighborReportTable" INDEX { dot11RMNeighborReportIndex } ::= { dot11RMNeighborReportTable 1 } Dot11RMNeighborReportEntry ::= SEQUENCE { dot11RMNeighborReportIndex Unsigned32, dot11RMNeighborReportIfIndex InterfaceIndex, dot11RMNeighborReportBSSID MacAddress, dot11RMNeighborReportAPReachability INTEGER, dot11RMNeighborReportSecurity TruthValue, dot11RMNeighborReportCapSpectrumMgmt TruthValue, dot11RMNeighborReportCapQoS TruthValue, dot11RMNeighborReportCapAPSD TruthValue, dot11RMNeighborReportCapRM TruthValue, dot11RMNeighborReportCapDelayBlockAck TruthValue, dot11RMNeighborReportCapImmediateBlockAck TruthValue, dot11RMNeighborReportKeyScope TruthValue, dot11RMNeighborReportOperatingClass Unsigned32, dot11RMNeighborReportChannelNumber Unsigned32, dot11RMNeighborReportPhyType INTEGER, dot11RMNeighborReportNeighborTSFInfo OCTET STRING, dot11RMNeighborReportPilotInterval Unsigned32, dot11RMNeighborReportPilotMultipleBSSID OCTET STRING, dot11RMNeighborReportRMEnabledCapabilities OCTET STRING, dot11RMNeighborReportVendorSpecific OCTET STRING, dot11RMNeighborReportRowStatus RowStatus, dot11RMNeighborReportMobilityDomain TruthValue, dot11RMNeighborReportCapHT TruthValue, dot11RMNeighborReportHTLDPCCodingCap TruthValue, dot11RMNeighborReportHTSupportedChannelWidthSet TruthValue, dot11RMNeighborReportHTSMPowerSave Unsigned32, dot11RMNeighborReportHTGreenfield TruthValue, dot11RMNeighborReportHTShortGIfor20MHz TruthValue, dot11RMNeighborReportHTShortGIfor40MHz TruthValue, dot11RMNeighborReportHTTxSTBC TruthValue, dot11RMNeighborReportHTRxSTBC Unsigned32, dot11RMNeighborReportHTDelayedBlockAck TruthValue, dot11RMNeighborReportHTMaxAMSDULength TruthValue, dot11RMNeighborReportHTDSSCCKModein40MHz TruthValue, dot11RMNeighborReportHTFortyMHzIntolerant TruthValue, dot11RMNeighborReportHTLSIGTXOPProtectionSupport TruthValue, dot11RMNeighborReportHTMaxAMPDULengthExponent Unsigned32, dot11RMNeighborReportHTMinMPDUStartSpacing Unsigned32, dot11RMNeighborReportHTRxMCSBitMask OCTET STRING, dot11RMNeighborReportHTRxHighestSupportedDataRate Unsigned32, dot11RMNeighborReportHTTxMCSSetDefined TruthValue, dot11RMNeighborReportHTTxRxMCSSetNotEqual TruthValue, dot11RMNeighborReportHTTxMaxNumberSpatialStreamsSupported Unsigned32, dot11RMNeighborReportHTTxUnequalModulationSupported TruthValue, dot11RMNeighborReportHTPCO TruthValue, dot11RMNeighborReportHTPCOTransitionTime Unsigned32, dot11RMNeighborReportHTMCSFeedback Unsigned32, dot11RMNeighborReportHTCSupport TruthValue, dot11RMNeighborReportHTRDResponder TruthValue, dot11RMNeighborReportHTImplictTransmitBeamformingReceivingCap TruthValue, dot11RMNeighborReportHTReceiveStaggeredSoundingCap TruthValue, dot11RMNeighborReportHTTransmitStaggeredSoundingCap TruthValue, dot11RMNeighborReportHTReceiveNDPCap TruthValue, dot11RMNeighborReportHTTransmitNDPCap TruthValue, dot11RMNeighborReportHTImplicitTransmitBeamformingCap TruthValue, dot11RMNeighborReportHTTransmitBeamformingCalibration Unsigned32, dot11RMNeighborReportHTExplicitCSITransmitBeamformingCap TruthValue, dot11RMNeighborReportHTExplicitNonCompressedSteeringCap TruthValue, dot11RMNeighborReportHTExplicitCompressedSteeringCap TruthValue, dot11RMNeighborReportHTExplicitTransmitBeamformingFeedback Unsigned32, dot11RMNbRprtHTExplicitNonCompressedBeamformingFeedbackCap Unsigned32, dot11RMNeighborReportHTExplicitCompressedBeamformingFeedbackCap Unsigned32, dot11RMNeighborReportHTTransmitBeamformingMinimalGrouping Unsigned32, dot11RMNbRprtHTCSINumberofTxBeamformingAntennasSuppt Unsigned32, dot11RMNbRprtHTNonCompressedSteeringNumofTxBmfmingAntennasSuppt Unsigned32, dot11RMNbRprtHTCompressedSteeringNumberofTxBmfmingAntennasSuppt Unsigned32, dot11RMNbRprtHTCSIMaxNumberofRowsTxBeamformingSuppt Unsigned32, dot11RMNeighborReportHTTransmitBeamformingChannelEstimationCap Unsigned32, dot11RMNeighborReportHTAntSelectionCap TruthValue, dot11RMNeighborReportHTExplicitCSIFeedbackBasedTxASELCap TruthValue, dot11RMNeighborReportHTAntIndicesFeedbackBasedTxASELCap TruthValue, dot11RMNeighborReportHTExplicitCSIFeedbackBasedCap TruthValue, dot11RMNeighborReportHTAntIndicesFeedbackCap TruthValue, dot11RMNeighborReportHTRxASELCap TruthValue, dot11RMNeighborReportHTTxSoundingPPDUsCap TruthValue, dot11RMNeighborReportHTInfoPrimaryChannel Unsigned32, dot11RMNeighborReportHTInfoSecChannelOffset Unsigned32, dot11RMNeighborReportHTInfoSTAChannelWidth TruthValue, dot11RMNeighborReportHTInfoRIFSMode TruthValue, dot11RMNeighborReportHTInfoProtection Unsigned32, dot11RMNeighborReportHTInfoNonGreenfieldHTSTAsPresent TruthValue, dot11RMNeighborReportHTInfoOBSSNonHTSTAsPresent TruthValue, dot11RMNeighborReportHTInfoDualBeacon TruthValue, dot11RMNeighborReportHTInfoDualCTSProtection TruthValue, dot11RMNeighborReportHTInfoSTBCBeacon TruthValue, dot11RMNeighborReportHTInfoLSIGTXOPProtectionSup TruthValue, dot11RMNeighborReportHTInfoPCOActive TruthValue, dot11RMNeighborReportHTInfoPCOPhase TruthValue, dot11RMNeighborReportHTInfoBasicMCSSet OCTET STRING, dot11RMNeighborReportHTSecChannelOffset Unsigned32, dot11RMNeighborReportExtCapPSMPSupport TruthValue, dot11RMNeighborReportExtCapSPSMPSup TruthValue, dot11RMNeighborReportExtCapServiceIntervalGranularity Unsigned32, dot11RMNeighborReportBSSTransitCandPreference Unsigned32, dot11RMNeighborReportBSSTerminationTSF TSFType, dot11RMNeighborReportBSSTerminationDuration Unsigned32 } dot11RMNeighborReportIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for neighbor report configuration table in dot11RMNeighborReportTable, greater than 0." ::= { dot11RMNeighborReportEntry 1 } dot11RMNeighborReportIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The ifIndex for this row of the neighbor report." ::= { dot11RMNeighborReportEntry 2 } dot11RMNeighborReportBSSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the BSSID of the BSS of the AP described by this row of neighbor report." ::= { dot11RMNeighborReportEntry 3 } dot11RMNeighborReportAPReachability OBJECT-TYPE SYNTAX INTEGER { notReachable(1), unknown(2), reachable(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the reachability of the AP represented by the dot11RMNeighborReportBSSID." ::= { dot11RMNeighborReportEntry 4 } dot11RMNeighborReportSecurity OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute, when true, indicates that the neighbor AP identified by this BSSID supports the same security provisioning as used by the AP which provided this neighbor report. This attribute, when false, indicates either that the neighbor AP identified by this BSSID does not support the same security provisioning or that the security information for this neighbor AP is not available at this time." ::= { dot11RMNeighborReportEntry 5 } dot11RMNeighborReportCapSpectrumMgmt OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the spectrum management capability of the AP represented by dot11RMNeighborReportBSSID." ::= { dot11RMNeighborReportEntry 6 } dot11RMNeighborReportCapQoS OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the QoS capability of the AP represented by dot11RMNeighborReportBSSID." ::= { dot11RMNeighborReportEntry 7 } dot11RMNeighborReportCapAPSD OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the APSD capability of the AP represented by dot11RMNeighborReportBSSID." ::= { dot11RMNeighborReportEntry 8 } dot11RMNeighborReportCapRM OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute is equal to true when the AP, represented by dot11RMNeighborReportBSSID, transmits a RM Enabled Capabilities element; and is false otherwise." ::= { dot11RMNeighborReportEntry 9 } dot11RMNeighborReportCapDelayBlockAck OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the delayed block ack capability of the AP represented by dot11RMNeighborReportBSSID." ::= { dot11RMNeighborReportEntry 10 } dot11RMNeighborReportCapImmediateBlockAck OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the immediate block ack capability of the AP represented by dot11RMNeighborReportBSSID." ::= { dot11RMNeighborReportEntry 11 } dot11RMNeighborReportKeyScope OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute, when true, indicates the neighbor AP identified by this BSSID has the same authenticator as the AP which provided this neighbor report. This attribute, when false, indicates that the neighbor AP identified by this BSSID has a different authenticator or that authenticator information is not available." ::= { dot11RMNeighborReportEntry 12 } dot11RMNeighborReportOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the channel set for this neighbor report entry. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement report. Valid values of Operating Class are shown in Annex E." ::= { dot11RMNeighborReportEntry 13 } dot11RMNeighborReportChannelNumber OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the current operating channel of the AP represented by the dot11RMNeighborReportBSSID. The Channel Number is defined only within the indicated Operating Class for this neighbor report entry." ::= { dot11RMNeighborReportEntry 14 } dot11RMNeighborReportPhyType OBJECT-TYPE SYNTAX INTEGER { dsss(2), ofdm(4), hrdsss(5), erp(6), ht(7), dmg(8), vht(9), tvht(10), s1g(11), cdmg(12), cmmg(13)} MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the PHY Type of the neighbor AP identified by this BSSID." ::= { dot11RMNeighborReportEntry 15 } dot11RMNeighborReportNeighborTSFInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates TSF timing information for the neighbor AP identified by this BSSID. The TSF timing information includes the TSF Offset and the Beacon Interval, as defined in 9.4.2.36." ::= { dot11RMNeighborReportEntry 16 } dot11RMNeighborReportPilotInterval OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the measurement pilot interval for the neighbor AP identified by this BSSID, as defined in 9.4.1.18." ::= { dot11RMNeighborReportEntry 17 } dot11RMNeighborReportPilotMultipleBSSID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) UNITS "BSSID LSBs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates n, where 2^n is the maximum number of BSSIDs in the multiple BSSID set, as described in 11.10.14." ::= { dot11RMNeighborReportEntry 18 } dot11RMNeighborReportRMEnabledCapabilities OBJECT-TYPE SYNTAX OCTET STRING (SIZE(7)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute indicates the detailed enabled capabilities of the AP represented by the dot11RMNeighborReportBSSID, as defined in 9.4.2.44." ::= { dot11RMNeighborReportEntry 19 } dot11RMNeighborReportVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This attribute provides an envelope for any optional vendor specific subelements which may be included in a measurement report element." DEFVAL { ''H } ::= { dot11RMNeighborReportEntry 20 } dot11RMNeighborReportRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. Contains the row status of the neighbor report, essentially used for indicating whether the row has all valid attributes filled in. Then set to active to be used in Neighbor Report elements. If any parameter is invalid, the SME sets this attribute back to notReady. It is the responsibility of the manager to correct the parameters." ::= { dot11RMNeighborReportEntry 21 } dot11RMNeighborReportMobilityDomain OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. Indicates a common mobility domain identifier (MDID) and an identical value of the FT Capability and Policy value." ::= { dot11RMNeighborReportEntry 22 } dot11RMNeighborReportCapHT OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The High Throughput Bit when equal to 1 indicates that the AP represented by this BSSID is an HT AP including the HT Capabilities element in its Beacons and that the contents of that HT Capabilities element are identical to the HT Capabilities element advertised by the AP sending the report. See 9.4.2.36" ::= { dot11RMNeighborReportEntry 23 } dot11RMNeighborReportHTLDPCCodingCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for receiving LDPC coded packets, equal to false if not supported, equal to true if supported. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 24 } dot11RMNeighborReportHTSupportedChannelWidthSet OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates which channel widths the STA supports, equal to false if only 20 MHz operation is supported, equal to true if both 20 MHz and 40 MHz operation is supported. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 25 } dot11RMNeighborReportHTSMPowerSave OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the SM power save mode, equal to 0 for static SM power save mode, equal to 1 for dynamic SM power save mode, equal to 3 for SM power save disabled or not supported, the value 2 is reserved; see 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 26 } dot11RMNeighborReportHTGreenfield OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for the reception of PPDUs with HT-greenfield format, equal to false if not supported, equal to true if supported. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 27 } dot11RMNeighborReportHTShortGIfor20MHz OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates short GI support for the reception of 20 MHz packets, equal to false if not supported, equal to true if supported See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 28 } dot11RMNeighborReportHTShortGIfor40MHz OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates short GI support for the reception of 40 MHz packets, equal to false if not supported, equal to true if supported. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 29} dot11RMNeighborReportHTTxSTBC OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for the transmission of PPDUs using STBC, equal to false if not supported, equal to true if supported. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 30} dot11RMNeighborReportHTRxSTBC OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for the reception of PPDUs using STBC, equal to 0 for no support, equal to 1 for support of one spatial stream, equal to 2 for support of one and two spatial streams, equal to 3 for support of one, two, and three spatial streams. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 31} dot11RMNeighborReportHTDelayedBlockAck OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from the standard. This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for HT-delayed block ack operation, equal to false if not supported, equal to true if supported. Support indicates that the STA is able to accept an ADDBA request for HT-delayed block ack. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 32 } dot11RMNeighborReportHTMaxAMSDULength OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates maximum A-MSDU length, equal to false for 3839 octets, equal to true for 7935 octets. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 33 } dot11RMNeighborReportHTDSSCCKModein40MHz OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates use of DSSS/CCK mode in a 40MC BSS operating in 20/40 MHz mode, equal to false if DSSS/CCK in 40 MHz is not allowed, equal to true if the DSSS/CCK in 40 MHz is allowed. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 34 } dot11RMNeighborReportHTFortyMHzIntolerant OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether other BSSs receiving this information are required to prohibit 40 MHz transmissions, equal to true to prohibit 20/40 MHz BSS operation, otherwise equal to false. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 35 } dot11RMNeighborReportHTLSIGTXOPProtectionSupport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for the L-SIG TXOP protection mechanism, equal to false if not supported, equal to true if supported. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 36 } dot11RMNeighborReportHTMaxAMPDULengthExponent OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the maximum length of A-MPDU that the STA can receive. This field is an integer in the range 0 to 3. The length defined by this field is equal to 2 ^ (13 + Maximum A-MPDU Length) - 1 octets. See 9.4.2.55.3" ::= { dot11RMNeighborReportEntry 37 } dot11RMNeighborReportHTMinMPDUStartSpacing OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable determines the minimum time between the start of adjacent MPDUs within an AMPDU, measured at the PHY SAP, equal to 0 for no restriction, equal to 1 for 1/4 microsecond, equal to 2 for 1/2 microsecond, equal to 3 for 1 microsecond, equal to 4 for 2 microseconds, equal to 5 for 4 microseconds, equal to 6 for 8 microseconds, equal to 7 for 16 microseconds. See 9.4.2.55.3" ::= { dot11RMNeighborReportEntry 38 } dot11RMNeighborReportHTRxMCSBitMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable is a 77-bit bitmap that defines a set of MCS values, where bit B0 (i.e., the lsb of the first octet) corresponds to MCS 0 and bit B76 corresponds to MCS 76, equal to 0 when the MCS is not supported, equal to 1 when the MCS is supported. See 9.4.2.55.4" ::= { dot11RMNeighborReportEntry 39} dot11RMNeighborReportHTRxHighestSupportedDataRate OBJECT-TYPE SYNTAX Unsigned32 (1..1023) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable defines the highest HT PPDU data rate that the STA is able to receive, in units of 1 Mb/s. See 9.4.2.55.4" ::= { dot11RMNeighborReportEntry 40 } dot11RMNeighborReportHTTxMCSSetDefined OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates if the Tx MCS set is defined, equal to false if no Tx MCS set is defined, equal to true if Tx MCS set is defined. See 9.4.2.55.4" ::= { dot11RMNeighborReportEntry 41 } dot11RMNeighborReportHTTxRxMCSSetNotEqual OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates if the Tx MCS set is defined to be equal to the Rx MCS set, equal to false where no Tx MCS set is defined or where the Tx MCS Set is defined to be equal to the RX MCS Set, equal to true where the TX MCS set may differ from the Rx MCS set. See 9.4.2.55.4" ::= { dot11RMNeighborReportEntry 42 } dot11RMNeighborReportHTTxMaxNumberSpatialStreamsSupported OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates maximum number of spatial streams supported when the Tx MCS Set may differ from the Rx MCS set, equal to 0 where no TX MCS set is defined or where the Tx MCS set is defined to be equal to the RX MCS set or where the maximum number of spatial streams supported when transmitting is 1 spatial stream and the Tx MCS set may differ from the Rx MCS set, equal to 1 where the maximum number of spatial streams supported when transmitting is 2 spatial streams and the Tx MCS set may differ from the Rx MCS set, equal to 2 where the maximum number of spatial streams supported when transmitting is 3 spatial streams and the Tx MCS set may differ from the Rx MCS set, equal to 3 where the maximum number of spatial streams supported when transmitting is 4 spatial streams and the Tx MCS set may differ from the Rx MCS set. See 9.4.2.55.4" ::= { dot11RMNeighborReportEntry 43 } dot11RMNeighborReportHTTxUnequalModulationSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether transmit UEQM is supported when the Tx MCS set may differ from the Rx MCS set, equal to false where no TX MCS set is defined or where the Tx MCS set is defined to be equal to the RX MCS set or when UEQM is not supported and the Tx MCS set may differ from the Rx MCS set, equal to true when UEQM is supported and the Tx MCS set may differ from the Rx MCS set. See 9.4.2.55.4" ::= { dot11RMNeighborReportEntry 44 } dot11RMNeighborReportHTPCO OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for PCO, equal to false if not supported, equal to true if supported. See 9.4.2.55.5" ::= { dot11RMNeighborReportEntry 45 } dot11RMNeighborReportHTPCOTransitionTime OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates that the STA can switch between 20 MHz channel width and 40 MHz channel width within the indicated time, equal to 0 for no transition, equal to 1 for 400 microseconds, equal to 2 for 1.5 ms, equal to 3 for 5 ms. For the no transition case (equal to 0) the PCO active STA does not change its operation channel width and is able to receive 40 MHz PPDUs during the 20 MHz phase. See 9.4.2.55.5" ::= { dot11RMNeighborReportEntry 46 } dot11RMNeighborReportHTMCSFeedback OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the capability of the STA to provide MFB, equal to 0 if the STA does not provide MFB, equal to 2 if the STA provide only unsolicited MFB, equal to 3 if the STA can provide MFB in response to MRQ as well as unsolicited MFB. Note the value 1 is reserved. See 9.4.2.55.5" ::= { dot11RMNeighborReportEntry 47 } dot11RMNeighborReportHTCSupport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support of the HT Control field, equal to false if not supported, equal to true if supported. See 9.4.2.55.5" ::= { dot11RMNeighborReportEntry 48 } dot11RMNeighborReportHTRDResponder OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for acting as a revere direction responder, equal to false if not supported, equal to true if supported. See 9.4.2.55.5" ::= { dot11RMNeighborReportEntry 49} dot11RMNeighborReportHTImplictTransmitBeamformingReceivingCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA can receive Transmit Beamforming steered frames using implicit feedback, equal to false if not supported, equal to true if supported. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 50 } dot11RMNeighborReportHTReceiveStaggeredSoundingCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA can receive staggered sounding frames, equal to false if not supported, equal to true if supported. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 51 } dot11RMNeighborReportHTTransmitStaggeredSoundingCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA can transmit staggered sounding frames, equal to false if not supported, equal to true if supported. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 52 } dot11RMNeighborReportHTReceiveNDPCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this receiver can interpret NDPs as sounding frames, equal to false if not supported, equal to true if supported. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 53 } dot11RMNeighborReportHTTransmitNDPCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA can transmit NDPs as sounding frames, equal to false if not supported, equal to true if supported. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 54 } dot11RMNeighborReportHTImplicitTransmitBeamformingCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA can apply implicit transmit beamforming, equal to false if not supported, equal to true if supported. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 55 } dot11RMNeighborReportHTTransmitBeamformingCalibration OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates that the STA can participate in a calibration procedure initiated by another STA that is capable of generating an immediate response Sounding PPDU and can provide a CSI report in response to a Sounding PPDU, equal to 0 if not supported, equal to 1 is the STA can respond to a calibration request using the CSI report but cannot initiate calibration, equal to 3 if the STA can both initiate and respond to a calibration request. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 56 } dot11RMNeighborReportHTExplicitCSITransmitBeamformingCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA can apply transmit beamforming using SCI explicit feedback in its transmission, equal to false if not supported, equal to true if supported. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 57 } dot11RMNeighborReportHTExplicitNonCompressedSteeringCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. The variable indicates whether this STA can apply transmit beamforming using noncompressed beamforming feedback matrix explicit feedback in its transmission, equal to false if not supported, equal to true if supported. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 58 } dot11RMNeighborReportHTExplicitCompressedSteeringCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA can apply transmit beamforming using compressed beamforming feedback matrix explicit feedback in its transmission, equal to false if not supported, equal to true if supported. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 59} dot11RMNeighborReportHTExplicitTransmitBeamformingFeedback OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this receiver can return CSI explicit feedback, equal to 0 if not supported, equal to 1 for delayed feedback, equal to 2 for immediate feedback, equal to 3 for delayed and immediate feedback. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 60 } dot11RMNbRprtHTExplicitNonCompressedBeamformingFeedbackCap OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this receiver can return noncompressed beamforming feedback matrix explicit feedback, equal to 0 if not supported, equal to 1 for delayed feedback, equal to 2 for immediate feedback, equal to 3 for delayed and immediate feedback. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 61 } dot11RMNeighborReportHTExplicitCompressedBeamformingFeedbackCap OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this receiver can return compressed beamforming feedback matrix explicit feedback, equal to 0 if not supported, equal to 1 for delayed feedback, equal to 2 for immediate feedback, equal to 3 for delayed and immediate feedback. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 62 } dot11RMNeighborReportHTTransmitBeamformingMinimalGrouping OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the minimal grouping used for explicit feedback reports, equal to 0 if the STA supports groups of 1 (no grouping), equal to 1 to indicate groups of 1, 2, equal to 2 to indicate groups of 1, 4, equal to 3 to indicate groups of 1, 2, 4. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 63 } dot11RMNbRprtHTCSINumberofTxBeamformingAntennasSuppt OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the maximum number of beamformer antennas the beamformee can support when CSI feedback is required, equal to 0 for single Tx antenna sounding, equal to 1 for 2 Tx antenna sounding, equal to 2 for 3 Tx antenna sounding, equal to 3 for 4 Tx antenna sounding. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 64 } dot11RMNbRprtHTNonCompressedSteeringNumofTxBmfmingAntennasSuppt OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the maximum number of beamformer antennas the beamformee can support when noncompressed beamforming feedback matrix is required, equal to 0 for single Tx antenna sounding, equal to 1 for 2 Tx antenna sounding, equal to 2 for 3 Tx antenna sounding, equal to 3 for 4 Tx antenna sounding. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 65 } dot11RMNbRprtHTCompressedSteeringNumberofTxBmfmingAntennasSuppt OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the maximum number of beamformer antennas the beamformee can support when compressed beamforming feedback matrix is required, equal to 0 for single Tx antenna sounding, equal to 1 for 2 Tx antenna sounding, equal to 2 for 3 Tx antenna sounding, equal to 3 for 4 Tx antenna sounding. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 66 } dot11RMNbRprtHTCSIMaxNumberofRowsTxBeamformingSuppt OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the maximum number of rows of CSI explicit feedback from the beamformee or calibration responder or transmit ASEL responder that a beamformer or calibration initiator or transmit ASEL initiator can support when SCI feedback is required, equal to 0 for a single row of CSI, equal to 1 for 2 rows of CSI, equal to 2 for 3 rows of CSI, equal to 3 for 4 rows of CSI. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 67 } dot11RMNeighborReportHTTransmitBeamformingChannelEstimationCap OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the maximum number of space-time streams for which channel dimensions can be simultaneously estimated when receiving an NDP sounding PPDU or the extension portion of the HT-LTFs in a staggered sounding PPDU. Equal to 0 for 1 space-time stream, equal to 1 for 2 space-time streams, equal to 2 for 3 space-time streams, equal to 3 for 4 space-time streams. See 9.4.2.55.6" ::= { dot11RMNeighborReportEntry 68 } dot11RMNeighborReportHTAntSelectionCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA supports ASEL, equal to false if not supported, equal to true if supported. See 9.4.2.55.7" ::= { dot11RMNeighborReportEntry 69} dot11RMNeighborReportHTExplicitCSIFeedbackBasedTxASELCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA has transmit ASEL capability based on explicit CSI feedback, equal to false if not supported, equal to true if supported. See 9.4.2.55.7" ::= { dot11RMNeighborReportEntry 70 } dot11RMNeighborReportHTAntIndicesFeedbackBasedTxASELCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA has transmit ASEL capability based on antenna indices feedback, equal to false if not supported, equal to true if supported. See 9.4.2.55.7" ::= { dot11RMNeighborReportEntry 71 } dot11RMNeighborReportHTExplicitCSIFeedbackBasedCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA can compute CSI and feedback in support of ASEL, equal to false if not supported, equal to true is supported. See 9.4.2.55.7" ::= { dot11RMNeighborReportEntry 72 } dot11RMNeighborReportHTAntIndicesFeedbackCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA has Rx ASEL capability, equal to false if not supported, equal to true if supported. See 9.4.2.55.7" ::= { dot11RMNeighborReportEntry 73 } dot11RMNeighborReportHTRxASELCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA has Rx ASEL capability, equal to false if not supported, equal to true if supported. See 9.4.2.55.7" ::= { dot11RMNeighborReportEntry 74 } dot11RMNeighborReportHTTxSoundingPPDUsCap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether this STA can transmit sounding PPDUs for ASEL training per request, equal to false if not supported, equal to true if supported. See 9.4.2.55.7" ::= { dot11RMNeighborReportEntry 75 } dot11RMNeighborReportHTInfoPrimaryChannel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the channel number of the primary channel, encoding: channel number of the primary channel. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 76 } dot11RMNeighborReportHTInfoSecChannelOffset OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the offset of the secondary channel relative to the primary channel, equal to 1 if the secondary channel is above the primary channel, equal to 3 if the secondary channel is below the primary channel, equal to 0 if no secondary channel is present. The value 2 is reserved. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 77 } dot11RMNeighborReportHTInfoSTAChannelWidth OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable defines the channel widths that may be used to transmit to the STA, equal to false for a 20 MHz channel width, equal to true allows use of any channel width in the supported channel width set. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 78 } dot11RMNeighborReportHTInfoRIFSMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether use of RIFS is permitted within the BSS, equal to false if use of RIFS is prohibited, equal to true if use of RIFS is permitted. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 79} dot11RMNeighborReportHTInfoProtection OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates protection requirements of HT transmissions. Equal to 0 if all STAs detected in the primary or the secondary channel or that are a member of this BSS are HT STAs and either all STAs that are known by the transmitting STA to be a member of this BSS are 20/40 MHz HT in a 20/40 MHz BSS or this BSS is a 20 MHz BSS. Equal to 1 (nonmember protection mode) if there is at least one non-HT STA detected in either the primary or the secondary channel or in both the primary and secondary channels and that is not known by the transmitting STA to be a member of this BSS and all STAs that are known by the transmitting STA to be a member of this BSS are HT STAs. Equal to 2 if all STAs detected in the primary or the secondary channel or that are known by the transmitting STA to be a member of this BSS are HT STAs and this BSS is a 20/40 MHz BSS and there is at least one 20 MHz HT STA associated with this BSS. Equal to 3 (non-HT mixed mode) otherwise. See 9.4.2.55.2" ::= { dot11RMNeighborReportEntry 80 } dot11RMNeighborReportHTInfoNonGreenfieldHTSTAsPresent OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates if any HT STAs that are not HT-greenfield capable have associated. Determines when a non-AP STA should use HT-greenfield protection. Present in Beacon and Probe Response frames transmitted by an AP. Equal to false if all HT STAs that are associated are HT-greenfield capable, equal to true if one or more HT STAs that are not HT-greenfield capable are associated. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 81 } dot11RMNeighborReportHTInfoOBSSNonHTSTAsPresent OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates if the use of protection for non-HT STAs by OBSSs is determined to be desirable. Present in Beacon and Probe Response frames transmitted by an AP, equal to true if the use of protection for non-HT STAs by OBSSs is determined to be desirable, equal to false otherwise. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 82 } dot11RMNeighborReportHTInfoDualBeacon OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether the AP transmits an STBC beacon, equal to false if no STBC beacon is transmitted, equal to true if an STBC beacon is transmitted. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 83 } dot11RMNeighborReportHTInfoDualCTSProtection OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable is used by the AP to set a NAV at STAs that do not support STBC and at STAs that can associate solely through the secondary beacon, equal to false if dual CTS protection is not required, equal to true if dual CTS protection is required. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 84 } dot11RMNeighborReportHTInfoSTBCBeacon OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether the beacon containing this element is a primary or a STBC beacon, equal to false in a primary beacon, equal to true in a STBC beacon. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 85 } dot11RMNeighborReportHTInfoLSIGTXOPProtectionSup OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether all HT STA in the BSS support L-SIG TXOP protection, equal to false if one or more HT STA in the BSS do not support L-SIG TXOP protection, equal to true if all HT STA in the BSS support L-SIG TXOP protection. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 86 } dot11RMNeighborReportHTInfoPCOActive OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates whether PCO is active in the BSS, equal to false if PCO is not active in the BSS, equal to true if PCO is active in the BSS. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 87} dot11RMNeighborReportHTInfoPCOPhase OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the PCO phase of operation, equal to false indicates a switch to or continued 20 MHz phase, equal to true indicates a switch to or continuation of 40 MHz phase. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 88 } dot11RMNeighborReportHTInfoBasicMCSSet OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates values that are supported by all HT STAs in the BSS. The Basic HT-MCS Set is a bitmap of size 128 bits. Bit 0 corresponds to MCS 0. A bit is equal to 1 to indicate support for that MCS, equal to 0 otherwise. See 9.4.2.56" ::= { dot11RMNeighborReportEntry 89 } dot11RMNeighborReportHTSecChannelOffset OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the position of the secondary channel relative to the primary channel, equal to 1 to indicate that the secondary channel is above the primary channel, equal to 3 to indicate the secondary channel is below the primary channel, equal to 0 to indicate that no secondary channel is present. The value 2 is reserved. See 9.4.2.19" ::= { dot11RMNeighborReportEntry 90 } dot11RMNeighborReportExtCapPSMPSupport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for PSMP operation, equal to false if PSMP is not supported, equal to true if PSMP operation is supported. See 9.4.2.26" ::= { dot11RMNeighborReportEntry 91 } dot11RMNeighborReportExtCapSPSMPSup OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates support for scheduled PSMP, equal to false when PSMP is supported is equal to false and when the PSMP Capability field is equal to 1 if the STA does not support S-PSMP, equal to true when the PSMP Capability field is equal to 1 if the STA supports S-PSMP. See 9.4.2.26." ::= { dot11RMNeighborReportEntry 92 } dot11RMNeighborReportExtCapServiceIntervalGranularity OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a measurement report is completed. This variable indicates the duration of the shortest SI, equal to 0 for 5 ms, equal to 1 for 10 ms, equal to 2 for 15 ms, equal to 3 for 20 ms, equal to 4 for 25 ms, equal to 5 for 30 ms, equal to 6 for 35 ms, equal to 7 for 40 ms. See 9.4.2.26." ::= { dot11RMNeighborReportEntry 93 } dot11RMNeighborReportBSSTransitCandPreference OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the network preference for BSS transition to the BSS listed in this BSS Transition Candidate List Entries field in the BSS Transition Management Request frame, BSS Transition Management Query frame and BSS Transition Management Response frame. The Preference field value is a number ranging from 0 to 255 indicating an ordering of preferences for the BSS transition candidates for this STA. The value 0 indicates an excluded BSS. The values 1-255 the preferred relative ordering of BSSs, with 255 indicating the most preferred candidate and 1 indicating the least preferred candidate. Additional details describing use of the Preference field are provided in 11.21.7.3." ::= { dot11RMNeighborReportEntry 94 } dot11RMNeighborReportBSSTerminationTSF OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the value of the TSF timer when the BSS termination will occur in the future. A BSS Termination TSF field value of 0 indicates that termination of the BSS will occur imminently. Prior to termination of the BSS, all associated STAs are disassociated by the AP." ::= { dot11RMNeighborReportEntry 95 } dot11RMNeighborReportBSSTerminationDuration OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "minutes" MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates the number of minutes for which the BSS is not present. The Duration field value of 0 is reserved. The Duration field value is set to 65 535 when the BSS is terminated for a period longer than or equal to 65 535 minutes." ::= { dot11RMNeighborReportEntry 96 } -- ******************************************************************** -- * End of dot11RMNeighborReport TABLE -- ******************************************************************** -- ******************************************************************** -- * END of Radio Measurement Interface MIB -- ******************************************************************** -- ******************************************************************** -- * Wireless Network Management Interface MIB -- ******************************************************************** dot11WirelessNetworkManagement OBJECT IDENTIFIER ::= { dot11smt 22 } -- ******************************************************************** -- * Wireless network management requests -- ******************************************************************** dot11WNMRequest OBJECT IDENTIFIER ::= { dot11WirelessNetworkManagement 1 } -- ******************************************************************** -- * dot11WNMRequest TABLE -- ******************************************************************** dot11WNMRequestNextIndex OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when able to accept a new request. Identifies a hint for the next value of dot11WNMRqstIndex to be used in a row creation attempt for dot11WNMRequestTable. If no new rows can be created for some reason, such as memory, processing requirements, etc, the SME shall set this attribute to 0. It shall update this attribute to a proper value other than 0 as soon as it is capable of receiving new measurement requests. The nextIndex is not necessarily sequential nor monotonically increasing." ::= { dot11WNMRequest 1 } dot11WNMRequestTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMRequestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This group contains the current list of requests for WNM reports to be issued and have been issued until removed. A network manager adds a WNM request by creating a row with createAndWait row status and then filling in the request parameters/attributes. The request becomes active to be issued when the row status is set to Active. The columnar objects or attributes other than the rowStatus shall not be written if the rowStatus is Active. The request rows can be deleted, if commanded by a network manager via changing the value of dot11WNMRqstRowStatus to Destroy. This may leave orphaned rows if a manager crashes and forgets which rows are being used by it. One recommended way to manage orphaned or finished rows is to delete rows if their dot11WNMRqstRowStatus remains other than Active for longer than a period (recommend at least 5 minutes, IETF RFC 2579). Or another recommended way is to delete older rows as needed based on their dot11WNMRqstTimeStamp values. This can be done by the agent as well as the manager." ::= { dot11WNMRequest 2 } dot11WNMRequestEntry OBJECT-TYPE SYNTAX Dot11WNMRequestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMRequestTable Indexed by dot11WNMRqstIndex." INDEX { dot11WNMRqstIndex } ::= { dot11WNMRequestTable 1 } Dot11WNMRequestEntry ::= SEQUENCE { dot11WNMRqstIndex Unsigned32, dot11WNMRqstRowStatus RowStatus, dot11WNMRqstToken OCTET STRING, dot11WNMRqstIfIndex InterfaceIndex, dot11WNMRqstType INTEGER, dot11WNMRqstTargetAdd MacAddress, dot11WNMRqstTimeStamp TimeTicks, dot11WNMRqstRndInterval Unsigned32, dot11WNMRqstDuration Unsigned32, dot11WNMRqstMcstGroup MacAddress, dot11WNMRqstMcstTrigCon OCTET STRING, dot11WNMRqstMcstTrigInactivityTimeout Unsigned32, dot11WNMRqstMcstTrigReactDelay Unsigned32, dot11WNMRqstLCRRqstSubject INTEGER, dot11WNMRqstLCRIntervalUnits INTEGER, dot11WNMRqstLCRServiceInterval Unsigned32, dot11WNMRqstLIRRqstSubject INTEGER, dot11WNMRqstLIRIntervalUnits INTEGER, dot11WNMRqstLIRServiceInterval Unsigned32, dot11WNMRqstEventToken Unsigned32, dot11WNMRqstEventType INTEGER, dot11WNMRqstEventResponseLimit Unsigned32, dot11WNMRqstEventTargetBssid MacAddress, dot11WNMRqstEventSourceBssid MacAddress, dot11WNMRqstEventTransitTimeThresh Unsigned32, dot11WNMRqstEventTransitMatchValue OCTET STRING, dot11WNMRqstEventFreqTransitCountThresh Unsigned32, dot11WNMRqstEventFreqTransitInterval Unsigned32, dot11WNMRqstEventRsnaAuthType OCTET STRING, dot11WNMRqstEapType Unsigned32, dot11WNMRqstEapVendorId OCTET STRING, dot11WNMRqstEapVendorType OCTET STRING, dot11WNMRqstEventRsnaMatchValue OCTET STRING, dot11WNMRqstEventPeerMacAddress MacAddress, dot11WNMRqstOperatingClass Unsigned32, dot11WNMRqstChanNumber Unsigned32, dot11WNMRqstDiagToken Unsigned32, dot11WNMRqstDiagType INTEGER, dot11WNMRqstDiagTimeout Unsigned32, dot11WNMRqstDiagBssid MacAddress, dot11WNMRqstDiagProfileId Unsigned32, dot11WNMRqstDiagCredentials INTEGER, dot11WNMRqstLocConfigLocIndParams OCTET STRING, dot11WNMRqstLocConfigChanList OCTET STRING, dot11WNMRqstLocConfigBcastRate Unsigned32, dot11WNMRqstLocConfigOptions OCTET STRING, dot11WNMRqstBssTransitQueryReason INTEGER, dot11WNMRqstBssTransitReqMode OCTET STRING, dot11WNMRqstBssTransitDisocTimer Unsigned32, dot11WNMRqstBssTransitSessInfoURL OCTET STRING, dot11WNMRqstBssTransitCandidateList OCTET STRING, dot11WNMRqstColocInterfAutoEnable TruthValue, dot11WNMRqstColocInterfRptTimeout Unsigned32, dot11WNMRqstVendorSpecific OCTET STRING, dot11WNMRqstDestinationURI OCTET STRING } dot11WNMRqstIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for WNM Request elements in dot11WNMRequestTable, greater than 0." ::= { dot11WNMRequestEntry 1 } dot11WNMRqstRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when requesting a measurement, and by the SME when accepting a management request. The Row Status column of the current row, used for tracking status of an individual request. When this attribute is set to Active, AND a measurement request can be unambiguously created based on the parameters in the row, then the MLME may proceed to issue the request to its intended targets when appropriate. If not, this attribute may be set to Not-ready immediately to indicate parametric errors. However, it is the network managers responsibility to correct the error. If the request is successfully issued to the target STA, then the rowStatus is set to notInService." ::= { dot11WNMRequestEntry 2 } dot11WNMRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when the table entry is created, i.e., when requesting a measurement. Changes take effect when dot11RMRqstRowStatus is set to Active. This attribute indicates a unique string to identify this request. To guarantee the uniqueness of this token across multiple network managers, it is recommended that this token be prefixed with the IP address of the network manager creating this row. This token is not necessarily equivalent to the measurement tokens in WNM request frames." ::= { dot11WNMRequestEntry 3 } dot11WNMRqstIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex for this row of WNM Request to be issued on." ::= { dot11WNMRequestEntry 4 } dot11WNMRqstType OBJECT-TYPE SYNTAX INTEGER { mcastDiagnostics(0), locationCivic(1), locationIdentifier(2), event(3), dignostic(4), locationConfiguration(5), bssTransitionQuery(6), bssTransitionRqst(7), fms(8), colocInterference(9) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the request type of this WNM request row." ::= { dot11WNMRequestEntry 5 } dot11WNMRqstTargetAdd OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. The MAC address of STA for this row of WNM Request is to be issued to. If this attribute matches the MAC address of the dot11WNMRqstIfIndex, then measurement request is for this STA itself to carry out." ::= { dot11WNMRequestEntry 6 } dot11WNMRqstTimeStamp OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the SysUpTime Value the last time when dot11WNMRqstRowStatus is set to active or when this row is created the first time. This attribute shall be set by this STA or AP automatically, not by an SNMP manager." ::= { dot11WNMRequestEntry 7 } dot11WNMRqstRndInterval OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the upper bound of the random delay to be used prior to making the measurement. See 11.10.3." DEFVAL { 0 } ::= { dot11WNMRequestEntry 8 } dot11WNMRqstDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the preferred or mandatory measurement duration for this Measurement Request." DEFVAL { 0 } ::= { dot11WNMRequestEntry 9 } dot11WNMRqstMcstGroup OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. Multicast Group address indicates the MAC address of the multicast group for which diagnostics are requested. The BSSID shall be set to the wildcard BSSID when the measurement is to be performed on any multicast group on the operating channel. This attribute is valid only if the dot11WNMRqstType is 10, indicating a multicast diagnostic request, and is ignored otherwise." DEFVAL { 'FFFFFFFFFFFF'H } ::= { dot11WNMRequestEntry 10 } dot11WNMRqstMcstTrigCon OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the trigger condition for the Multicast Diagnostic request." ::= { dot11WNMRequestEntry 11 } dot11WNMRqstMcstTrigInactivityTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..255) UNITS "100 TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the time interval value to be use as the threshold value for Trigger Inactivity Timeout trigger condition." ::= { dot11WNMRequestEntry 12 } dot11WNMRqstMcstTrigReactDelay OBJECT-TYPE SYNTAX Unsigned32 (1..255) UNITS "100 TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the time interval value during which a measuring STA does not generate further multicast triggered reports after a trigger condition has been met." ::= { dot11WNMRequestEntry 13 } dot11WNMRqstLCRRqstSubject OBJECT-TYPE SYNTAX INTEGER { local(0), remote(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. The attribute indicates the subject of the Location Civic request." DEFVAL { 0 } ::= { dot11WNMRequestEntry 14 } dot11WNMRqstLCRIntervalUnits OBJECT-TYPE SYNTAX INTEGER { seconds(0), minutes(1), hours(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the units used in the Location Civic Request Service Interval." ::= { dot11WNMRequestEntry 15 } dot11WNMRqstLCRServiceInterval OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the time interval, expressed in the units indicated in the Location Civic Request Service Interval Units field, at which the STA requests to receive Location Civic reports. A Location Civic Request Service Interval of 0 indicates that only a single Location Civic report is requested." ::= { dot11WNMRequestEntry 16 } dot11WNMRqstLIRRqstSubject OBJECT-TYPE SYNTAX INTEGER { local(0), remote(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. The attribute indicates the subject of the Location Identifier request." DEFVAL { 0 } ::= { dot11WNMRequestEntry 17 } dot11WNMRqstLIRIntervalUnits OBJECT-TYPE SYNTAX INTEGER { seconds(0), minutes(1), hours(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the units used in the Location Identifier request Service Interval." ::= { dot11WNMRequestEntry 18 } dot11WNMRqstLIRServiceInterval OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the time interval, expressed in the units indicated in the Location Identifier Request Interval Units field, at which the STA requests to receive Location Identifier reports. A Location Identifier Request Service Interval of 0 indicates that only a single Location Identifier report is requested." ::= { dot11WNMRequestEntry 19 } dot11WNMRqstEventToken OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates a unique string to identify this request." ::= { dot11WNMRequestEntry 20 } dot11WNMRqstEventType OBJECT-TYPE SYNTAX INTEGER { transition(0), rsna(1), peerToPeer(2), wnmLog(3), vendorSpecific(221) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the request type of this WNM Event request." ::= { dot11WNMRequestEntry 21 } dot11WNMRqstEventResponseLimit OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the maximum number of requested Event Reports to be included in the Event Report element. A value of 0 indicates that no limit is set on the number of Event Reports to be included in the Event Report element." ::= { dot11WNMRequestEntry 22 } dot11WNMRqstEventTargetBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute is used to request that a Transition or RSNA Event Report includes the event entry when the target BSSID is equal to the indicated BSSID. A transition event is a STA movement or attempted movement from one BSS (the source BSS) in one ESS to another BSS (the target BSS) within the same ESS. The BSSID shall be set to the wildcard BSSID when the transitions to any BSSID is requested." DEFVAL { 'FFFFFFFFFFFF'H } ::= { dot11WNMRequestEntry 23 } dot11WNMRqstEventSourceBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute is used to request that a Transition Event Report includes the transition event entry when the source BSSID is equal to the indicated BSSID. A transition event is a STA movement or attempted movement from one BSS (the source BSS) in one ESS to another BSS (the target BSS) within the same ESS. The BSSID shall be set to the wildcard BSSID when the transitions from any BSSID is requested." DEFVAL { 'FFFFFFFFFFFF'H } ::= { dot11WNMRequestEntry 24 } dot11WNMRqstEventTransitTimeThresh OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates a value representing the transition time to be used as the threshold value for the Transition Time condition in TUs. The Transition Time is defined in 11.21.2.2" ::= { dot11WNMRequestEntry 25 } dot11WNMRqstEventTransitMatchValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates a request for the specified transition results that match the bit descriptions of this field. b0 indicates match when transition is successful. b1 indicates match when transition fails." ::= { dot11WNMRequestEntry 26 } dot11WNMRqstEventFreqTransitCountThresh OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the minimum number of matching transitions detected in the measurement duration to generate a Transition Event report." ::= { dot11WNMRequestEntry 27 } dot11WNMRqstEventFreqTransitInterval OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the sliding window time interval during which the STA detects matching transitions to determine if the Frequent Transition Count Threshold is exceeded in order to generate a Transition Event report." ::= { dot11WNMRequestEntry 28 } dot11WNMRqstEventRsnaAuthType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute is used to request that an RSNA Event Report include the event entry when its RSNA Authentication Type matches the indicated RSNA authentication type value." ::= { dot11WNMRequestEntry 29 } dot11WNMRqstEapType OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute is used to request that an RSNA Event Report include the event entry when its EAP Type matches the indicated EAP type value. Valid EAP Type numbers are assigned by IANA and are defined at http://www.iana.org/assignments/eap-numbers." ::= { dot11WNMRequestEntry 30 } dot11WNMRqstEapVendorId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..3)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute is used to request that an RSNA Event Report include the event entry when its EAP Vendor ID matches the indicated vendor ID value. The EAP Vendor ID field is included when the EAP Type field is set to 254 and is excluded otherwise." ::= { dot11WNMRequestEntry 31 } dot11WNMRqstEapVendorType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..4)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute is used to request that an RSNA Event Report include the event entry when its EAP Vendor Type matches the indicated EAP vendor type value. The EAP Vendor ID field is included when the EAP Type field is set to 254 and is excluded otherwise." ::= { dot11WNMRequestEntry 32 } dot11WNMRqstEventRsnaMatchValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates a request for the specified transition results that match the bit descriptions of this field. b0 (least significant bit) indicates match when RSNA is successful. b1 indicates match when RSNA fails." ::= { dot11WNMRequestEntry 33 } dot11WNMRqstEventPeerMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute is used to request that a peer-to-peer link event report includes the transition event entry when the MAC address of the peer STA or IBSS BSSID is equal to the indicated MAC address. The MAC address shall be set to the wildcard BSSID when the transitions from any peer STA or IBSS BSSID is requested." DEFVAL { 'FFFFFFFFFFFF'H } ::= { dot11WNMRequestEntry 34 } dot11WNMRqstOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the channel set for this WNM request. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement request. Valid values of Operating Class are shown in Annex E." ::= { dot11WNMRequestEntry 35 } dot11WNMRqstChanNumber OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the current operating channel for this WNM request. The Channel Number is defined only within the indicated Operating Class as shown in Annex E." ::= { dot11WNMRequestEntry 36 } dot11WNMRqstDiagToken OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates a unique string to identify this request." ::= { dot11WNMRequestEntry 37 } dot11WNMRqstDiagType OBJECT-TYPE SYNTAX INTEGER { cancelRequest(0), manufacturerInfoStaRep(1), configurationProfile(2), associationDiag(3), ieee8021xAuthDiag(4), vendorSpecific(221) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the request type of this WNM Diagnostic request." ::= { dot11WNMRequestEntry 38 } dot11WNMRqstDiagTimeout OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates a value representing the time interval after a Diagnostic Report is generated during which no additional Diagnostic Reports shall be sent." ::= { dot11WNMRequestEntry 39 } dot11WNMRqstDiagBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates a request for a Diagnostic Report from the indicated BSSID. The BSSID shall be set to the wildcard BSSID when diagnostics from any BSSID is requested." DEFVAL { 'FFFFFFFFFFFF'H } ::= { dot11WNMRequestEntry 40 } dot11WNMRqstDiagProfileId OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates a unique identifier for referencing a configuration profile available on a device. The value of the identifier can be any arbitrary value, as long as it is uniquely associated to a single configuration profile on the device sending the identifier." ::= { dot11WNMRequestEntry 41 } dot11WNMRqstDiagCredentials OBJECT-TYPE SYNTAX INTEGER { none(0), preSharedKey(1), usernamePassword(2), x509Certificate(3), otherCertificate(4), oneTimePassword(5), token(6) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the type of credential used for the IEEE 802.1X authentication." ::= { dot11WNMRequestEntry 42 } dot11WNMRqstLocConfigLocIndParams OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates STA Location reporting characteristics. The format of these Location Indication Parameters are detailed in 9.4.2.70.2." ::= { dot11WNMRequestEntry 43 } dot11WNMRqstLocConfigChanList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..252)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute lists location reporting channel information for this location configuration request. Each pair of octets indicates a different operating class and channel number for this request. The detailed format for this list of channels is described in 9.4.2.70.3." DEFVAL { ''H } ::= { dot11WNMRequestEntry 44 } dot11WNMRqstLocConfigBcastRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "0.5 Mb/s" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the target data rate at which the STA transmits Location Track Notification frames. A value of 0 indicates the STA transmits Location Track Notification frames at a rate chosen by the STA transmitting the Location Track Notification frames." ::= { dot11WNMRequestEntry 45 } dot11WNMRqstLocConfigOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the location track indication options used; see 9.4.2.70.9." DEFVAL { ''H } ::= { dot11WNMRequestEntry 46 } dot11WNMRqstBssTransitQueryReason OBJECT-TYPE SYNTAX INTEGER { unspecified(0), excessiveFrameLossRatesPoorConditions(1), excessiveDelayForCurrentTrafficStreams(2), insufficientQosCapacityForCurrentTrafficStreams(3), firstAssociationToEss(4), loadBalancing(5), betterApFound(6), deauthenticatedDisassociatedFromPreviousAp(7), apFailedIeee8021XEapAuthentication(8), apFailed4wayHandshake(9), receivedTooManyReplayCounterFailures(10), receivedTooManyDataMICFailures(11), exceededMaxNumberOfRetransmissions(12), receivedTooManyBroadcastDisassociations(13), receivedTooManyBroadcastDeauthentications(14), previousTransitionFailed(15), lowRSSI(16) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the reason for the BSS Transition Query. The format for this list of reasons is further detailed in 9.4.2.67.2." ::= { dot11WNMRequestEntry 47 } dot11WNMRqstBssTransitReqMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the type of BSS request transition. b0 (least significant bit) indicates the Preferred Candidate list is included in this frame. b1 indicates an abridged format for all BSSIDs not listed in this frame. b2 indicates that the STA will be disassociated for the current AP. b3 indicates the BSS is shutting down and that the STA will be disassociated. b4 indicates that the will be disassociated from the ESS. The format for this field is detailed in 9.6.13.9." ::= { dot11WNMRequestEntry 48 } dot11WNMRqstBssTransitDisocTimer OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the number of TBTTs until the serving AP sends a Disassociation frame to this STA. The value 0 indicates unknown. If the Disassociation Imminent bit of the Request Mode field is set to 0, this field is ignored." ::= { dot11WNMRequestEntry 49 } dot11WNMRqstBssTransitSessInfoURL OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute contains a variable length field formatted in accordance with IETF RFC 3986-2005." ::= { dot11WNMRequestEntry 50 } dot11WNMRqstBssTransitCandidateList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..11426)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute lists one or more Neighbor Report elements described in 9.4.2.36. If the STA has no Transition Candidate information in response to the BSS Transition Management Query frame, the candidate list is null. " ::= { dot11WNMRequestEntry 51 } dot11WNMRqstColocInterfAutoEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute, when true, indicates that the requesting STA requests the receiving STA to send the Collocated Interference Response frames periodically with the Report Period interval, as defined in 9.6.13.13, or when the STA detects a change in the collocated interference." ::= { dot11WNMRequestEntry 52 } dot11WNMRqstColocInterfRptTimeout OBJECT-TYPE SYNTAX Unsigned32 (0..127) UNITS "100 TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute indicates the minimum duration between two consecutive Collocated Interference Response frames from the reporting STA." ::= { dot11WNMRequestEntry 53 } dot11WNMRqstVendorSpecific OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute provides an envelope for any optional vendor specific subelements that may be included in a WNM request element." DEFVAL { ''H } ::= { dot11WNMRequestEntry 54} dot11WNMRqstDestinationURI OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..253)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity when making a management request. Changes take effect when dot11WNMRqstRowStatus is set to Active. This attribute provides the Destination URI which defines an alternate destination for the WNM request. The alternate destination may be an internet address on an Ethernet adapter, for example, to be used when the wireless link to the requesting entity is unavailable or unreliable." DEFVAL { ''H } ::= { dot11WNMRequestEntry 55} -- ********************************************************************** -- * End of dot11WNMRequest TABLE -- ********************************************************************** -- ******************************************************************** -- * Wireless network management reports: -- * Report tables contain WNM reports received by this STA or -- * results of WNM requests performed by this STA. -- ******************************************************************** dot11WNMReport OBJECT IDENTIFIER ::= { dot11WirelessNetworkManagement 2 } -- ******************************************************************** -- * dot11WNMVendorSpecificReport TABLE -- ******************************************************************** dot11WNMVendorSpecificReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMVendorSpecificReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of Vendor Specific reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 1 } dot11WNMVendorSpecificReportEntry OBJECT-TYPE SYNTAX Dot11WNMVendorSpecificReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMVendorSpecificReportTable Indexed by dot11WNMVendorSpecificRprtIndex." INDEX { dot11WNMVendorSpecificRprtIndex } ::= { dot11WNMVendorSpecificReportTable 1 } Dot11WNMVendorSpecificReportEntry ::= SEQUENCE { dot11WNMVendorSpecificRprtIndex Unsigned32, dot11WNMVendorSpecificRprtRqstToken OCTET STRING, dot11WNMVendorSpecificRprtIfIndex InterfaceIndex, dot11WNMVendorSpecificRprtContent OCTET STRING } dot11WNMVendorSpecificRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Vendor Specific Report elements in dot11WNMVendorSpecificReportTable, greater than 0." ::= { dot11WNMVendorSpecificReportEntry 1 } dot11WNMVendorSpecificRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMVendorSpecificReportEntry 2 } dot11WNMVendorSpecificRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMVendorSpecific report has been received on." ::= { dot11WNMVendorSpecificReportEntry 3 } dot11WNMVendorSpecificRprtContent OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute provides an envelope for all of the vendor specific subelements that may be included in a WNM Vendor Specific request element." DEFVAL { ''H } ::= { dot11WNMVendorSpecificReportEntry 4 } -- ******************************************************************** -- * End of dot11WNMVendorSpecificReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMMulticastDiagnosticReport TABLE -- ******************************************************************** dot11WNMMulticastDiagnosticReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMMulticastDiagnosticReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of Multicast Diagnostic reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 2 } dot11WNMMulticastDiagnosticReportEntry OBJECT-TYPE SYNTAX Dot11WNMMulticastDiagnosticReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMMulticastDiagnosticReportTable Indexed by dot11WNMMulticastDiagnosticRprtIndex." INDEX { dot11WNMMulticastDiagnosticRprtIndex } ::= { dot11WNMMulticastDiagnosticReportTable 1 } Dot11WNMMulticastDiagnosticReportEntry ::= SEQUENCE { dot11WNMMulticastDiagnosticRprtIndex Unsigned32, dot11WNMMulticastDiagnosticRprtRqstToken OCTET STRING, dot11WNMMulticastDiagnosticRprtIfIndex InterfaceIndex, dot11WNMMulticastDiagnosticRprtMeasurementTime TSFType, dot11WNMMulticastDiagnosticRprtDuration Unsigned32, dot11WNMMulticastDiagnosticRprtMcstGroup MacAddress, dot11WNMMulticastDiagnosticRprtReason OCTET STRING, dot11WNMMulticastDiagnosticRprtRcvdMsduCount Unsigned32, dot11WNMMulticastDiagnosticRprtFirstSeqNumber Unsigned32, dot11WNMMulticastDiagnosticRprtLastSeqNumber Unsigned32, dot11WNMMulticastDiagnosticRprtMcstRate Unsigned32 } dot11WNMMulticastDiagnosticRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Multicast Diagnostics reports in dot11WNMMulticastDiagnosticReportTable, greater than 0." ::= { dot11WNMMulticastDiagnosticReportEntry 1 } dot11WNMMulticastDiagnosticRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMMulticastDiagnosticReportEntry 2 } dot11WNMMulticastDiagnosticRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMMulticastDiagnostic report been received on." ::= { dot11WNMMulticastDiagnosticReportEntry 3 } dot11WNMMulticastDiagnosticRprtMeasurementTime OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the value of the STA TSF timer at the time the measurement started. In a triggered Multicast Diagnostics report, this is the TSF value at the reporting STA when the trigger condition was met. When the reason for sending the report is Performance Measurement and the Multicast Received MSDU Count is nonzero, the Measurement Time field is set to the value of the STA TSF timer at the time of the first group addressed MSDU received during the measurement interval." ::= { dot11WNMMulticastDiagnosticReportEntry 4 } dot11WNMMulticastDiagnosticRprtDuration OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the period over which the Multicast Diagnostics report was generated." ::= { dot11WNMMulticastDiagnosticReportEntry 5 } dot11WNMMulticastDiagnosticRprtMcstGroup OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. Multicast Group address indicates the MAC address of the multicast group for this report element." ::= { dot11WNMMulticastDiagnosticReportEntry 6 } dot11WNMMulticastDiagnosticRprtReason OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the reason why the measuring STA sent the Multicast Diagnostics report. b0 (least significant bit) indicates Inactivity Timeout Trigger. b1 indicates the measurement result from the completed measurement. These are defined further in 9.4.2.21.12." ::= { dot11WNMMulticastDiagnosticReportEntry 7 } dot11WNMMulticastDiagnosticRprtRcvdMsduCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the total number of group addressed MSDUs with the indicated Multicast MAC Address that were received during the Measurement Duration. In a triggered multicast diagnostics measurement this is the total number of MSDUs received between the acceptance of the multicast diagnostics measurement request and the occurrence of the trigger condition for MSDUs with the indicated Multicast MAC Address." ::= { dot11WNMMulticastDiagnosticReportEntry 8 } dot11WNMMulticastDiagnosticRprtFirstSeqNumber OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the twelve least significant bits of the First Sequence Number field. When the LSB of the first octet of the Multicast MAC address field in the multicast diagnostic request is set to 1, the twelve LSBs of the First Sequence Number field contain the sequence number of the first frame received with destination address equal to the value in the Multicast MAC address field during the measurement period. When the LSB of the first octet of the Multicast MAC address field in the multicast diagnostic request is set to 0, the twelve LSBs of the First Sequence Number field contain the sequence number of the first group addressed frame, that does not have the broadcast address as its destination, received during the measurement period. The four most significant bits of the First Sequence Number field are set to 0. This field is set to 0 if the Multicast Received MSDU Count is 0." ::= { dot11WNMMulticastDiagnosticReportEntry 9 } dot11WNMMulticastDiagnosticRprtLastSeqNumber OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the twelve least significant bits of the Last Sequence Number field. When the LSB of the first octet of the Multicast MAC address field in the multicast diagnostic request is set to 1, the twelve LSBs of the Last Sequence Number field contain the sequence number of the last frame received with destination address equal to the value in the Multicast MAC address field during the measurement period. When the LSB of the first octet of the Multicast MAC address field in the multicast diagnostic request is 0, the twelve LSBs of the Last Sequence Number field contain the sequence number of the last group addressed frame, that does not have the broadcast address as its destination, received during the measurement period. The four most significant bits of the Last Sequence Number field are set to 0. This field is set to 0 if the Multicast Received MSDU Count is 0." ::= { dot11WNMMulticastDiagnosticReportEntry 10 } dot11WNMMulticastDiagnosticRprtMcstRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "0.5 Mb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the highest data rate at which the STA has received a group addressed frame during the measurement period. The Multicast Rate field is encoded with the MSB set to 1 to indicate that the data rate is in the basic rate set, and set to 0 to indicate that the data rate is not in the basic rate set. The remaining 15-bit value is multiplied by 0.5 Mb/s to indicate the data rate. The Multicast Rate field is set to 0 by the STA to indicate that it has not received a group addressed frame during the measurement period." ::= { dot11WNMMulticastDiagnosticReportEntry 11 } -- ******************************************************************** -- * End of dot11WNMMulticastDiagnosticReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMLocationCivicReport TABLE -- ******************************************************************** dot11WNMLocationCivicReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMLocationCivicReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of Location Civic reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 3 } dot11WNMLocationCivicReportEntry OBJECT-TYPE SYNTAX Dot11WNMLocationCivicReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMLocationCivicReportTable Indexed by dot11WNMLocationCivicRprtIndex." INDEX { dot11WNMLocationCivicRprtIndex } ::= { dot11WNMLocationCivicReportTable 1 } Dot11WNMLocationCivicReportEntry ::= SEQUENCE { dot11WNMLocationCivicRprtIndex Unsigned32, dot11WNMLocationCivicRprtRqstToken OCTET STRING, dot11WNMLocationCivicRprtIfIndex InterfaceIndex, dot11WNMLocationCivicRprtCivicLocation OCTET STRING } dot11WNMLocationCivicRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Location Civic reports in dot11WNMLocationCivicReportTable, greater than 0." ::= { dot11WNMLocationCivicReportEntry 1 } dot11WNMLocationCivicRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMLocationCivicReportEntry 2 } dot11WNMLocationCivicRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMLocationCivic report been received on." ::= { dot11WNMLocationCivicReportEntry 3 } dot11WNMLocationCivicRprtCivicLocation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates a variable octet field and contains a list of civic address elements in TLV format as defined in IETF RFC 4776." ::= { dot11WNMLocationCivicReportEntry 4} -- ******************************************************************** -- * End of dot11WNMLocationCivicReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMLocationIdentifierReport TABLE -- ******************************************************************** dot11WNMLocationIdentifierReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMLocationIdentifierReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of Location Identifier reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 4 } dot11WNMLocationIdentifierReportEntry OBJECT-TYPE SYNTAX Dot11WNMLocationIdentifierReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMLocationIdentifierReportTable Indexed by dot11WNMLocationIdentifierRprtIndex." INDEX { dot11WNMLocationIdentifierRprtIndex } ::= { dot11WNMLocationIdentifierReportTable 1 } Dot11WNMLocationIdentifierReportEntry ::= SEQUENCE { dot11WNMLocationIdentifierRprtIndex Unsigned32, dot11WNMLocationIdentifierRprtRqstToken OCTET STRING, dot11WNMLocationIdentifierRprtIfIndex InterfaceIndex, dot11WNMLocationIdentifierRprtExpirationTSF TSFType, dot11WNMLocationIdentifierRprtPublicIdUri OCTET STRING } dot11WNMLocationIdentifierRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Location Identifier reports in dot11WNMLocationIdentifierReportTable, greater than 0." ::= { dot11WNMLocationIdentifierReportEntry 1 } dot11WNMLocationIdentifierRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMLocationIdentifierReportEntry 2 } dot11WNMLocationIdentifierRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMLocationIdentifier report been received on." ::= { dot11WNMLocationIdentifierReportEntry 3 } dot11WNMLocationIdentifierRprtExpirationTSF OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the value of the STA TSF timer when the Public Identifier URI/FQDN field value is no longer valid. The Expiration TSF field set to 0 indicates the Public Identifier URI/FQDN does not expire." ::= { dot11WNMLocationIdentifierReportEntry 4 } dot11WNMLocationIdentifierRprtPublicIdUri OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains concatenated Public Identifier URI/FQDN subelements, one per Public Identifier URI or FQDN. The format for a Public Identifier URI/FQDN subelement is further detailed in 9.4.2.21.14." ::= { dot11WNMLocationIdentifierReportEntry 5} -- ******************************************************************** -- * End of dot11WNMLocationIdentifierReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMEventTransitReport TABLE -- ******************************************************************** dot11WNMEventTransitReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMEventTransitReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of Transition Event reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 5 } dot11WNMEventTransitReportEntry OBJECT-TYPE SYNTAX Dot11WNMEventTransitReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMEventTransitReportTable Indexed by dot11WNMEventTransitRprtIndex." INDEX { dot11WNMEventTransitRprtIndex } ::= { dot11WNMEventTransitReportTable 1 } Dot11WNMEventTransitReportEntry ::= SEQUENCE { dot11WNMEventTransitRprtIndex Unsigned32, dot11WNMEventTransitRprtRqstToken OCTET STRING, dot11WNMEventTransitRprtIfIndex InterfaceIndex, dot11WNMEventTransitRprtEventStatus INTEGER, dot11WNMEventTransitRprtEventTSF TSFType, dot11WNMEventTransitRprtUTCOffset OCTET STRING, dot11WNMEventTransitRprtTimeError OCTET STRING, dot11WNMEventTransitRprtSourceBssid MacAddress, dot11WNMEventTransitRprtTargetBssid MacAddress, dot11WNMEventTransitRprtTransitTime Unsigned32, dot11WNMEventTransitRprtTransitReason INTEGER, dot11WNMEventTransitRprtTransitResult Unsigned32, dot11WNMEventTransitRprtSourceRCPI Unsigned32, dot11WNMEventTransitRprtSourceRSNI Unsigned32, dot11WNMEventTransitRprtTargetRCPI Unsigned32, dot11WNMEventTransitRprtTargetRSNI Unsigned32 } dot11WNMEventTransitRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Transition Event Report elements in dot11WNMEventTransitReportTable, greater than 0." ::= { dot11WNMEventTransitReportEntry 1 } dot11WNMEventTransitRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMEventTransitReportEntry 2 } dot11WNMEventTransitRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMEventTransit report been received on." ::= { dot11WNMEventTransitReportEntry 3 } dot11WNMEventTransitRprtEventStatus OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the status value included in the Event report." ::= { dot11WNMEventTransitReportEntry 4 } dot11WNMEventTransitRprtEventTSF OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the value of the Event TSF field." ::= { dot11WNMEventTransitReportEntry 5 } dot11WNMEventTransitRprtUTCOffset OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the UTC Offset Time Value optionally included in the Event report." ::= { dot11WNMEventTransitReportEntry 6 } dot11WNMEventTransitRprtTimeError OBJECT-TYPE SYNTAX OCTET STRING (SIZE(5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the value of the Event Time Error field optionally included in the Event report. " ::= { dot11WNMEventTransitReportEntry 7 } dot11WNMEventTransitRprtSourceBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the source BSSID for the reported transition event." ::= { dot11WNMEventTransitReportEntry 8 } dot11WNMEventTransitRprtTargetBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the target BSSID for the reported transition event." ::= { dot11WNMEventTransitReportEntry 9 } dot11WNMEventTransitRprtTransitTime OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "TUs" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the transition time for the reported transition event in TUs. The Transition time is defined as the time difference between the starting time and the ending time of a transition between APs, even if the transition results in remaining on the same AP. Start and end times for a transition event are defined in 11.21.2.2" ::= { dot11WNMEventTransitReportEntry 10 } dot11WNMEventTransitRprtTransitReason OBJECT-TYPE SYNTAX INTEGER { unspecified(0), excessiveFrameLossRatesPoorConditions(1), excessiveDelayForCurrentTrafficStreams(2), insufficientQosCapacityForCurrentTrafficStreams(3), firstAssociationToEss(4), loadBalancing(5), betterApFound(6), deauthenticatedDisassociatedFromPreviousAp(7), apFailedIeee8021XEapAuthentication(8), apFailed4wayHandshake(9), receivedTooManyReplayCounterFailures(10), receivedTooManyDataMICFailures(11), exceededMaxNumberOfRetransmissions(12), receivedTooManyBroadcastDisassociations(13), receivedTooManyBroadcastDeauthentications(14), previousTransitionFailed(15), lowRSSI(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the reason for the reported BSS Transition event. The format for this list of reasons is further detailed in 9.4.2.67.2." ::= { dot11WNMEventTransitReportEntry 11 } dot11WNMEventTransitRprtTransitResult OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the result of the attempted transition and is set to one of the status codes specified in Table 9-50 in 9.4.1.9." ::= { dot11WNMEventTransitReportEntry 12 } dot11WNMEventTransitRprtSourceRCPI OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the received channel power of the most recently measured PPDU containing a frame from the Source BSSID before the STA reassociates to the Target BSSID. The Source RCPI is a logarithmic function of the received signal power, as defined 9.4.2.37." ::= { dot11WNMEventTransitReportEntry 13 } dot11WNMEventTransitRprtSourceRSNI OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the received signal-to-noise indication of the most recently measured frame from the Source BSSID before the STA reassociates to the Target BSSID. The Source RSNI is a logarithmic function of the signal-to-noise ratio, as defined in 9.4.2.40." ::= { dot11WNMEventTransitReportEntry 14 } dot11WNMEventTransitRprtTargetRCPI OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the received channel power of the first measured PPDU containing a frame from the Target BSSID just after STA reassociates to the Target BSSID. If association with target BSSID failed, the Target RCPI field indicates the received channel power of the most recently measured PPDU containing a frame from the Target BSSID. The Target RCPI is a logarithmic function of the received signal power, as defined 9.4.2.37." ::= { dot11WNMEventTransitReportEntry 15 } dot11WNMEventTransitRprtTargetRSNI OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the received signal-to-noise indication of the first measured frame just after STA reassociates to the Target BSSID. If association with target BSSID failed, the Target RSNI field indicates the received signal-to-noise indication of the most recently measured frame from the Target BSSID. The Target RSNI is a logarithmic function of the signal-to-noise ratio, as defined in 9.4.2.40." ::= { dot11WNMEventTransitReportEntry 16 } -- ******************************************************************** -- * End of dot11WNMEventTransitReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMEventRsnaReport TABLE -- ******************************************************************** dot11WNMEventRsnaReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMEventRsnaReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of RSNA Event reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 6 } dot11WNMEventRsnaReportEntry OBJECT-TYPE SYNTAX Dot11WNMEventRsnaReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMEventRsnaReportTable Indexed by dot11WNMEventRsnaRprtIndex." INDEX { dot11WNMEventRsnaRprtIndex } ::= { dot11WNMEventRsnaReportTable 1 } Dot11WNMEventRsnaReportEntry ::= SEQUENCE { dot11WNMEventRsnaRprtIndex Unsigned32, dot11WNMEventRsnaRprtRqstToken OCTET STRING, dot11WNMEventRsnaRprtIfIndex InterfaceIndex, dot11WNMEventRsnaRprtEventStatus INTEGER, dot11WNMEventRsnaRprtEventTSF TSFType, dot11WNMEventRsnaRprtUTCOffset OCTET STRING, dot11WNMEventRsnaRprtTimeError OCTET STRING, dot11WNMEventRsnaRprtTargetBssid MacAddress, dot11WNMEventRsnaRprtAuthType OCTET STRING, dot11WNMEventRsnaRprtEapMethod OCTET STRING, dot11WNMEventRsnaRprtResult Unsigned32, dot11WNMEventRsnaRprtRsnElement OCTET STRING } dot11WNMEventRsnaRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for RSNA Event Report elements in dot11WNMEventRsnaReportTable, greater than 0." ::= { dot11WNMEventRsnaReportEntry 1 } dot11WNMEventRsnaRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMEventRsnaReportEntry 2 } dot11WNMEventRsnaRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMEventRsna report been received on." ::= { dot11WNMEventRsnaReportEntry 3 } dot11WNMEventRsnaRprtEventStatus OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the status value included in the Event report." ::= { dot11WNMEventRsnaReportEntry 4 } dot11WNMEventRsnaRprtEventTSF OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the value of the Event TSF field." ::= { dot11WNMEventRsnaReportEntry 5 } dot11WNMEventRsnaRprtUTCOffset OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the UTC Offset Time Value optionally included in the Event report." ::= { dot11WNMEventRsnaReportEntry 6 } dot11WNMEventRsnaRprtTimeError OBJECT-TYPE SYNTAX OCTET STRING (SIZE(5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the value of the Event Time Error field optionally included in the Event report." ::= { dot11WNMEventRsnaReportEntry 7 } dot11WNMEventRsnaRprtTargetBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the BSSID of the BSS of the AP accepting the authorization attempt." ::= { dot11WNMEventRsnaReportEntry 8 } dot11WNMEventRsnaRprtAuthType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the AKM suite, as defined in Table 9-151 in 9.4.2.24.3. The first three octets indicate the OUI or CID. The last octet indicates the suite type." ::= { dot11WNMEventRsnaReportEntry 9 } dot11WNMEventRsnaRprtEapMethod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates a value that identifies the EAP Method. When the Authentication Type field is set to the value of either 00-0F-AC:1 (Authentication negotiated over IEEE Std 802.1X or using PMKSA caching as defined in 12.6.10.3) or 00-0F-AC:3 (AKM suite selector for fast BSS transition as defined in 12.7.1.6), the EAP Method field contains the IANA assigned EAP type defined at http://www.iana.org/assignments/eap-numbers. The EAP type contains either the legacy type (1 octet) or the expanded type (1-octet type = 254, 3-octet Vendor ID, 4-octet Vendor-Type). The EAP Method field is set to 0 otherwise." ::= { dot11WNMEventRsnaReportEntry 10 } dot11WNMEventRsnaRprtResult OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the result of the RSNA event and is set to one of the status codes specified in Table 9-50 in 9.4.1.9." ::= { dot11WNMEventRsnaReportEntry 11 } dot11WNMEventRsnaRprtRsnElement OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the entire contents of the negotiated RSNE at the time of the authentication attempt. The maximum length of the RSNE field is less than the maximum length of an RSNE, as defined in 9.4.2.24. If the length of the RSNE included here exceeds the maximum length of the RSNE field, the RSNE shall be truncated to the maximum length allowed for the RSNE field." ::= { dot11WNMEventRsnaReportEntry 12 } -- ******************************************************************** -- * End of dot11WNMEventRsnaReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMEventPeerReport TABLE -- ******************************************************************** dot11WNMEventPeerReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMEventPeerReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of peer-to-peer link event reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 7 } dot11WNMEventPeerReportEntry OBJECT-TYPE SYNTAX Dot11WNMEventPeerReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMEventPeerReportTable Indexed by dot11WNMEventPeerRprtIndex." INDEX { dot11WNMEventPeerRprtIndex } ::= { dot11WNMEventPeerReportTable 1 } Dot11WNMEventPeerReportEntry ::= SEQUENCE { dot11WNMEventPeerRprtIndex Unsigned32, dot11WNMEventPeerRprtRqstToken OCTET STRING, dot11WNMEventPeerRprtIfIndex InterfaceIndex, dot11WNMEventPeerRprtEventStatus INTEGER, dot11WNMEventPeerRprtEventTSF TSFType, dot11WNMEventPeerRprtUTCOffset OCTET STRING, dot11WNMEventPeerRprtTimeError OCTET STRING, dot11WNMEventPeerRprtPeerMacAddress MacAddress, dot11WNMEventPeerRprtOperatingClass Unsigned32, dot11WNMEventPeerRprtChanNumber Unsigned32, dot11WNMEventPeerRprtStaTxPower Integer32, dot11WNMEventPeerRprtConnTime Unsigned32, dot11WNMEventPeerRprtPeerStatus INTEGER } dot11WNMEventPeerRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Peer-to-Peer Link Event Report elements in dot11WNMEventPeerReportTable, greater than 0." ::= { dot11WNMEventPeerReportEntry 1 } dot11WNMEventPeerRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMEventPeerReportEntry 2 } dot11WNMEventPeerRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMEventPeer report been received on." ::= { dot11WNMEventPeerReportEntry 3 } dot11WNMEventPeerRprtEventStatus OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the status value included in the Event report." ::= { dot11WNMEventPeerReportEntry 4 } dot11WNMEventPeerRprtEventTSF OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the value of the Event TSF field." ::= { dot11WNMEventPeerReportEntry 5 } dot11WNMEventPeerRprtUTCOffset OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the UTC Offset Time Value optionally included in the Event report." ::= { dot11WNMEventPeerReportEntry 6 } dot11WNMEventPeerRprtTimeError OBJECT-TYPE SYNTAX OCTET STRING (SIZE(5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the value of the Event Time Error field optionally included in the Event report." ::= { dot11WNMEventPeerReportEntry 7 } dot11WNMEventPeerRprtPeerMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the MAC address of the peer STA or IBSS BSSID. If this event is for a peer-to-peer link in an infrastructure BSS, this field contains the MAC address of the peer STA. If this event is for a peer-to-peer link in an IBSS, this field contains the BSSID." ::= { dot11WNMEventPeerReportEntry 8 } dot11WNMEventPeerRprtOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the channel set for this peer-to-peer link event report. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement request. Valid values of Operating Class as shown in Annex E." ::= { dot11WNMEventPeerReportEntry 9 } dot11WNMEventPeerRprtChanNumber OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the current operating channel for this peer-to-peer link event report. The Channel Number is defined only within the indicated Operating Class as shown in Annex E." ::= { dot11WNMEventPeerReportEntry 10 } dot11WNMEventPeerRprtStaTxPower OBJECT-TYPE SYNTAX Integer32 (-128..127) UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the STA transmit power used for the peer-to-peer link. The STA Tx Power field indicates the target transmit power at the antenna connector with a tolerance of +/-5 dB for the lowest basic rate of the reporting STA." ::= { dot11WNMEventPeerReportEntry 11 } dot11WNMEventPeerRprtConnTime OBJECT-TYPE SYNTAX Unsigned32 (0..16777215) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates a value representing the connection time for the reported peer-to-peer link event. If the Peer Status is 0, this field indicates the duration of the Direct Link. If the Peer Status is 1, this field indicates the time difference from the time the Direct Link was established to the time at which the reporting STA generated the event report. If the Peer Status is 2, this field indicates the duration of the IBSS membership. If the Peer Status is 3, this field indicates the time difference from the time the STA joined the IBSS to the time at which the reporting STA generated the event report. See 11.21.2.4." ::= { dot11WNMEventPeerReportEntry 12 } dot11WNMEventPeerRprtPeerStatus OBJECT-TYPE SYNTAX INTEGER { directLinkTerminated(0), directLinkActive(1), ibssMembershipTerminated(2), ibssMembershipActive(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the peer link connection status." ::= { dot11WNMEventPeerReportEntry 13 } -- ******************************************************************** -- * End of dot11WNMEventPeerReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMEventWNMLogReport TABLE -- ******************************************************************** dot11WNMEventWNMLogReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMEventWNMLogReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of WNMLog Event reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 8 } dot11WNMEventWNMLogReportEntry OBJECT-TYPE SYNTAX Dot11WNMEventWNMLogReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMEventWNMLogReportTable Indexed by dot11WNMEventWNMLogRprtIndex." INDEX { dot11WNMEventWNMLogRprtIndex } ::= { dot11WNMEventWNMLogReportTable 1 } Dot11WNMEventWNMLogReportEntry ::= SEQUENCE { dot11WNMEventWNMLogRprtIndex Unsigned32, dot11WNMEventWNMLogRprtRqstToken OCTET STRING, dot11WNMEventWNMLogRprtIfIndex InterfaceIndex, dot11WNMEventWNMLogRprtEventStatus INTEGER, dot11WNMEventWNMLogRprtEventTSF TSFType, dot11WNMEventWNMLogRprtUTCOffset OCTET STRING, dot11WNMEventWNMLogRprtTimeError OCTET STRING, dot11WNMEventWNMLogRprtContent OCTET STRING } dot11WNMEventWNMLogRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for WNMLog Event Report elements in dot11WNMEventWNMLogReportTable, greater than 0." ::= { dot11WNMEventWNMLogReportEntry 1 } dot11WNMEventWNMLogRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMEventWNMLogReportEntry 2 } dot11WNMEventWNMLogRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMEventWNMLog report been received on." ::= { dot11WNMEventWNMLogReportEntry 3 } dot11WNMEventWNMLogRprtEventStatus OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the status value included in the Event report." ::= { dot11WNMEventWNMLogReportEntry 4 } dot11WNMEventWNMLogRprtEventTSF OBJECT-TYPE SYNTAX TSFType MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the value of the Event TSF field." ::= { dot11WNMEventWNMLogReportEntry 5 } dot11WNMEventWNMLogRprtUTCOffset OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the UTC Offset Time Value optionally included in the Event report." ::= { dot11WNMEventWNMLogReportEntry 6 } dot11WNMEventWNMLogRprtTimeError OBJECT-TYPE SYNTAX OCTET STRING (SIZE(5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the value of the Event Time Error field optionally included in the Event report." ::= { dot11WNMEventWNMLogReportEntry 7 } dot11WNMEventWNMLogRprtContent OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..2284)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the entire syslog message, consisting of the PRI, HEADER, and MSG portion of a WNM log message as described in IETF RFC 5424. The TAG field of the MSG portion of the message is a 17-octet string containing the ASCII representation of the STA MAC address using hexadecimal notation with colons between octets. The octet containing the Individual/Group bit occurs last, and that bit is in the least significant position within that octet. See 11.21.2.5." ::= { dot11WNMEventWNMLogReportEntry 8 } -- ******************************************************************** -- * End of dot11WNMEventWNMLogReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMDiagMfrInfoReport TABLE -- ******************************************************************** dot11WNMDiagMfrInfoReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMDiagMfrInfoReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of Manufacturer Information STA reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 9 } dot11WNMDiagMfrInfoReportEntry OBJECT-TYPE SYNTAX Dot11WNMDiagMfrInfoReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMDiagMfrInfoReportTable Indexed by dot11WNMDiagMfrInfoRprtIndex." INDEX { dot11WNMDiagMfrInfoRprtIndex } ::= { dot11WNMDiagMfrInfoReportTable 1 } Dot11WNMDiagMfrInfoReportEntry ::= SEQUENCE { dot11WNMDiagMfrInfoRprtIndex Unsigned32, dot11WNMDiagMfrInfoRprtRqstToken OCTET STRING, dot11WNMDiagMfrInfoRprtIfIndex InterfaceIndex, dot11WNMDiagMfrInfoRprtEventStatus INTEGER, dot11WNMDiagMfrInfoRprtMfrOi OCTET STRING, dot11WNMDiagMfrInfoRprtMfrIdString OCTET STRING, dot11WNMDiagMfrInfoRprtMfrModelString OCTET STRING, dot11WNMDiagMfrInfoRprtMfrSerialNumberString OCTET STRING, dot11WNMDiagMfrInfoRprtMfrFirmwareVersion OCTET STRING, dot11WNMDiagMfrInfoRprtMfrAntennaType OCTET STRING, dot11WNMDiagMfrInfoRprtCollocRadioType INTEGER, dot11WNMDiagMfrInfoRprtDeviceType INTEGER, dot11WNMDiagMfrInfoRprtCertificateID OCTET STRING} dot11WNMDiagMfrInfoRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Manufacturer Information STA Report elements in dot11WNMDiagMfrInfoReportTable, greater than 0." ::= { dot11WNMDiagMfrInfoReportEntry 1 } dot11WNMDiagMfrInfoRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMDiagMfrInfoReportEntry 2 } dot11WNMDiagMfrInfoRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMDiagMfrInfo report been received on." ::= { dot11WNMDiagMfrInfoReportEntry 3 } dot11WNMDiagMfrInfoRprtEventStatus OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the status value included in the Event report." ::= { dot11WNMDiagMfrInfoReportEntry 4} dot11WNMDiagMfrInfoRprtMfrOi OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..5)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the Manufacturer OI for the reported Manufacturer Information STA Diagnostic." ::= { dot11WNMDiagMfrInfoReportEntry 5 } dot11WNMDiagMfrInfoRprtMfrIdString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the Manufacturer ID string for the reported Manufacturer Information STA Diagnostic. The ID attribute contains an ASCII string indicating the manufacturer identifier of the wireless network adaptor. This string is not null terminated." ::= { dot11WNMDiagMfrInfoReportEntry 6 } dot11WNMDiagMfrInfoRprtMfrModelString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the Manufacturer model string for the reported Manufacturer Information STA Diagnostic. The model attribute contains an ASCII string indicating the model of the wireless network adaptor. This string is not null terminated." ::= { dot11WNMDiagMfrInfoReportEntry 7 } dot11WNMDiagMfrInfoRprtMfrSerialNumberString OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the Manufacturer serial number string for the reported Manufacturer Information STA Diagnostic. The serial number attribute contains an ASCII string indicating the serial number of the wireless network adaptor. This string is not null terminated." ::= { dot11WNMDiagMfrInfoReportEntry 8 } dot11WNMDiagMfrInfoRprtMfrFirmwareVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the Manufacturer firmware version string for the reported Manufacturer Information STA Diagnostic. The firmware version attribute contains an ASCII string identifying the version of firmware currently installed on the wireless network adaptor. This string is not null terminated." ::= { dot11WNMDiagMfrInfoReportEntry 9 } dot11WNMDiagMfrInfoRprtMfrAntennaType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the Manufacturer antenna type string for the reported Manufacturer Information STA Diagnostic. The first octet of this string indicates the antenna count, and the second octet indicates the antenna gain. The antenna gain indicates the peak gain in dBi of the antenna connected to the wireless network adaptor. The remaining octets contain an ASCII string indicating the type of antenna connected to the wireless network adaptor." ::= { dot11WNMDiagMfrInfoReportEntry 10 } dot11WNMDiagMfrInfoRprtCollocRadioType OBJECT-TYPE SYNTAX INTEGER { reserved(0), cellular(1), cordless(2), gps(3), ieee80211(4), ieee80215(5), ieee80216(6), ieee80220(7), ieee80222(8), digitalAudioBroadcasting(9), digitalVideoBroadcasting(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the type of the collocated radio." ::= { dot11WNMDiagMfrInfoReportEntry 11 } dot11WNMDiagMfrInfoRprtDeviceType OBJECT-TYPE SYNTAX INTEGER { reserved(0), referenceDesign(1), accessPointWirelessRouterSoho(2), enterpriseAccessPoint(3), broadbandGateway(4), digitalStillCamera(5), portableVideoCamera(6), networkedWebCamera(7), digitalAudioStationary(8), digitalAudioPortable(9), setTopBoxMediaServer(10), tvMonitorDigitalPictureFrame(11), gameConsoleGameAdaptor(12), gamingDevice(13), mediaServerMediaAdaptor(14), networkStorageDevice(15), externalCard(16), internalCard(17), ultraMobilPc(18), notebookComputer(19), personalDigitalAssistant(20), printerPrintServer(21), phoneDualMode(22), phoneSingleMode(23), smartphoneDualMode(24), smartphoneSingleMode(25), otherDevices(221) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the type of device in which the IEEE 802.11 STA resides." ::= { dot11WNMDiagMfrInfoReportEntry 12 } dot11WNMDiagMfrInfoRprtCertificateID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..251)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the Certificate ID for the reported Manufacturer Information STA Diagnostic." ::= { dot11WNMDiagMfrInfoReportEntry 13 } -- ******************************************************************** -- * End of dot11WNMDiagMfrInfoReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMDiagConfigProfReport TABLE -- ******************************************************************** dot11WNMDiagConfigProfReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMDiagConfigProfReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of Configuration Profile reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 10 } dot11WNMDiagConfigProfReportEntry OBJECT-TYPE SYNTAX Dot11WNMDiagConfigProfReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMDiagConfigProfReportTable Indexed by dot11WNMDiagConfigProfRprtIndex." INDEX { dot11WNMDiagConfigProfRprtIndex } ::= { dot11WNMDiagConfigProfReportTable 1 } Dot11WNMDiagConfigProfReportEntry ::= SEQUENCE { dot11WNMDiagConfigProfRprtIndex Unsigned32, dot11WNMDiagConfigProfRprtRqstToken OCTET STRING, dot11WNMDiagConfigProfRprtIfIndex InterfaceIndex, dot11WNMDiagConfigProfRprtEventStatus INTEGER, dot11WNMDiagConfigProfRprtProfileId Unsigned32, dot11WNMDiagConfigProfRprtSupportedOperatingClasses OCTET STRING, dot11WNMDiagConfigProfRprtTxPowerMode INTEGER, dot11WNMDiagConfigProfRprtTxPowerLevels OCTET STRING, dot11WNMDiagConfigProfRprtCipherSuite OCTET STRING, dot11WNMDiagConfigProfRprtAkmSuite OCTET STRING, dot11WNMDiagConfigProfRprtEapType Unsigned32, dot11WNMDiagConfigProfRprtEapVendorID OCTET STRING, dot11WNMDiagConfigProfRprtEapVendorType OCTET STRING, dot11WNMDiagConfigProfRprtCredentialType INTEGER, dot11WNMDiagConfigProfRprtSSID OCTET STRING, dot11WNMDiagConfigProfRprtPowerSaveMode INTEGER } dot11WNMDiagConfigProfRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Configuration Profile Report elements in dot11WNMDiagConfigProfReportTable, greater than 0." ::= { dot11WNMDiagConfigProfReportEntry 1 } dot11WNMDiagConfigProfRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMDiagConfigProfReportEntry 2 } dot11WNMDiagConfigProfRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMDiagConfigProf report been received on." ::= { dot11WNMDiagConfigProfReportEntry 3 } dot11WNMDiagConfigProfRprtEventStatus OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the status value included in the Event report." ::= { dot11WNMDiagConfigProfReportEntry 4} dot11WNMDiagConfigProfRprtProfileId OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates a unique identifier for referencing a configuration profile available on a device. The value of the identifier can be any arbitrary value, as long as it is uniquely associated to a single configuration profile on the device sending the identifier." ::= { dot11WNMDiagConfigProfReportEntry 5 } dot11WNMDiagConfigProfRprtSupportedOperatingClasses OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the current Operating Class followed by a list of each Supported Operating Class, as defined in 9.4.2.53. Each octet contains an integer representing an operating class. Operating Classes are defined in Annex E." DEFVAL { ''H } ::= { dot11WNMDiagConfigProfReportEntry 6 } dot11WNMDiagConfigProfRprtTxPowerMode OBJECT-TYPE SYNTAX INTEGER { fixedPowerMode(0), automaticPowerMode(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the power mode of the STA." ::= { dot11WNMDiagConfigProfReportEntry 7 } dot11WNMDiagConfigProfRprtTxPowerLevels OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute lists the power levels for the STA. Each octet contains an integer representing a power level encoded as a 2s complement value in dBm, rounded to the nearest integer. If the Power Mode is automatic, the list contains only the minimum and the maximum power levels for the STA. If the Power Mode is fixed, the list contains one or more fixed power level settings available at this STA, arranged in increasing numerical order." ::= { dot11WNMDiagConfigProfReportEntry 8 } dot11WNMDiagConfigProfRprtCipherSuite OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the cipher suite, as defined in Table 9-149. The first three octets indicate the OUI or CID. The last octet indicates the suite type." ::= { dot11WNMDiagConfigProfReportEntry 9 } dot11WNMDiagConfigProfRprtAkmSuite OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the AKM suite, as defined in Table 9-151 in 9.4.2.24.3. The first three octets indicate the OUI or CID. The last octet indicates the suite type." ::= { dot11WNMDiagConfigProfReportEntry 10 } dot11WNMDiagConfigProfRprtEapType OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the single EAP method used by the STA. Valid EAP Type numbers are assigned by IANA and are defined at http://www.iana.org/assignments/eap-numbers." ::= { dot11WNMDiagConfigProfReportEntry 11 } dot11WNMDiagConfigProfRprtEapVendorID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the EAP Vendor ID number for the EAP method used by the STA. The EAP Vendor ID field is included when the EAP Type field is set to 254 and is excluded otherwise." ::= { dot11WNMDiagConfigProfReportEntry 12 } dot11WNMDiagConfigProfRprtEapVendorType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the EAP Vendor Type number for the EAP method used by the STA. The EAP Vendor Type field is included when the EAP Type field is set to 254 and is excluded otherwise." ::= { dot11WNMDiagConfigProfReportEntry 13 } dot11WNMDiagConfigProfRprtCredentialType OBJECT-TYPE SYNTAX INTEGER { none(0), preSharedKey(1), userNamePassword(2), x509Certificate(3), otherCertificate(4), oneTimePassword(5), token(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the type of IEEE 802.1X credentials used by the STA for this authentication diagnostic." ::= { dot11WNMDiagConfigProfReportEntry 14 } dot11WNMDiagConfigProfRprtSSID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the SSID for the diagnostic report, as defined in 9.4.2.2." ::= { dot11WNMDiagConfigProfReportEntry 15 } dot11WNMDiagConfigProfRprtPowerSaveMode OBJECT-TYPE SYNTAX INTEGER { unknownMode(0), none(1), psDtims1Mode(2), psDtims0Mode(3), uapsdMode(4), sapsdMode(5), upsmpMode(6), spsmpMode(7), smpsMode(8), wnmSleepMode(9), fmsMode(10), timBroadcastMode(11), tfsMode(12), tdlsPeerUapsdMode(13), tdlsPeerPsmMode(14) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the power save mode in use by the STA, as defined in Table 9-207." ::= { dot11WNMDiagConfigProfReportEntry 16 } -- ******************************************************************** -- * End of dot11WNMDiagConfigProfReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMDiagAssocReport TABLE -- ******************************************************************** dot11WNMDiagAssocReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMDiagAssocReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of Association Diagnostic reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 11 } dot11WNMDiagAssocReportEntry OBJECT-TYPE SYNTAX Dot11WNMDiagAssocReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMDiagAssocReportTable Indexed by dot11WNMDiagAssocRprtIndex." INDEX { dot11WNMDiagAssocRprtIndex } ::= { dot11WNMDiagAssocReportTable 1 } Dot11WNMDiagAssocReportEntry ::= SEQUENCE { dot11WNMDiagAssocRprtIndex Unsigned32, dot11WNMDiagAssocRprtRqstToken OCTET STRING, dot11WNMDiagAssocRprtIfIndex InterfaceIndex, dot11WNMDiagAssocRprtEventStatus INTEGER, dot11WNMDiagAssocRprtBssid MacAddress, dot11WNMDiagAssocRprtOperatingClass Unsigned32, dot11WNMDiagAssocRprtChannelNumber Unsigned32, dot11WNMDiagAssocRprtStatusCode Unsigned32 } dot11WNMDiagAssocRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Association Diagnostic Report elements in dot11WNMDiagAssocReportTable, greater than 0." ::= { dot11WNMDiagAssocReportEntry 1 } dot11WNMDiagAssocRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMDiagAssocReportEntry 2 } dot11WNMDiagAssocRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMDiagAssoc report been received on." ::= { dot11WNMDiagAssocReportEntry 3 } dot11WNMDiagAssocRprtEventStatus OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the status value included in the Event report." ::= { dot11WNMDiagAssocReportEntry 4 } dot11WNMDiagAssocRprtBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the BSSID for the target AP for this Association Diagnostic report." ::= { dot11WNMDiagAssocReportEntry 5 } dot11WNMDiagAssocRprtOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the channel set for the target AP for this Association Diagnostic report. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement request. Valid values of Operating Class as shown in Annex E." ::= { dot11WNMDiagAssocReportEntry 6 } dot11WNMDiagAssocRprtChannelNumber OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the operating channel of the target AP for this Association Diagnostic report. The Channel Number is defined only within the indicated Operating Class as sown in Annex E." ::= { dot11WNMDiagAssocReportEntry 7 } dot11WNMDiagAssocRprtStatusCode OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the result of the association diagnostic and is set to one of the status codes specified in Table 9-50 in 9.4.1.9." ::= { dot11WNMDiagAssocReportEntry 8 } -- ******************************************************************** -- * End of dot11WNMDiagAssocReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMDiag8021xAuthReport TABLE -- ******************************************************************** dot11WNMDiag8021xAuthReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMDiag8021xAuthReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of IEEE 802.1X Authentication Diagnostic reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 12 } dot11WNMDiag8021xAuthReportEntry OBJECT-TYPE SYNTAX Dot11WNMDiag8021xAuthReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMDiag8021xAuthReportTable Indexed by dot11WNMDiag8021xAuthRprtIndex." INDEX { dot11WNMDiag8021xAuthRprtIndex } ::= { dot11WNMDiag8021xAuthReportTable 1 } Dot11WNMDiag8021xAuthReportEntry ::= SEQUENCE { dot11WNMDiag8021xAuthRprtIndex Unsigned32, dot11WNMDiag8021xAuthRprtRqstToken OCTET STRING, dot11WNMDiag8021xAuthRprtIfIndex InterfaceIndex, dot11WNMDiag8021xAuthRprtEventStatus INTEGER, dot11WNMDiag8021xAuthRprtBssid MacAddress, dot11WNMDiag8021xAuthRprtOperatingClass Unsigned32, dot11WNMDiag8021xAuthRprtChannelNumber Unsigned32, dot11WNMDiag8021xAuthRprtEapType Unsigned32, dot11WNMDiag8021xAuthRprtEapVendorID OCTET STRING, dot11WNMDiag8021xAuthRprtEapVendorType OCTET STRING, dot11WNMDiag8021xAuthRprtCredentialType INTEGER, dot11WNMDiag8021xAuthRprtStatusCode Unsigned32 } dot11WNMDiag8021xAuthRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for IEEE 802.1X Authentication Diagnostic Report elements in dot11WNMDiag8021xAuthReportTable, greater than 0." ::= { dot11WNMDiag8021xAuthReportEntry 1 } dot11WNMDiag8021xAuthRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMDiag8021xAuthReportEntry 2 } dot11WNMDiag8021xAuthRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMDiag8021xAuth report been received on." ::= { dot11WNMDiag8021xAuthReportEntry 3 } dot11WNMDiag8021xAuthRprtEventStatus OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the status value included in the Event report." ::= { dot11WNMDiag8021xAuthReportEntry 4 } dot11WNMDiag8021xAuthRprtBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the BSSID for the target AP for this Authentication Diagnostic report." ::= { dot11WNMDiag8021xAuthReportEntry 5 } dot11WNMDiag8021xAuthRprtOperatingClass OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the channel set for the target AP for this Authentication Diagnostic report. Country, Operating Class and Channel Number together specify the channel frequency and spacing for this measurement request. Valid values of Operating Class as shown in Annex E." ::= { dot11WNMDiag8021xAuthReportEntry 6 } dot11WNMDiag8021xAuthRprtChannelNumber OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the operating channel of the target AP for this Authentication Diagnostic report. The Channel Number is defined only within the indicated Operating Class as shown in Annex E." ::= { dot11WNMDiag8021xAuthReportEntry 7 } dot11WNMDiag8021xAuthRprtEapType OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the single EAP method used by the STA. Valid EAP Type numbers are assigned by IANA and are defined at http://www.iana.org/assignments/eap-numbers." ::= { dot11WNMDiag8021xAuthReportEntry 8 } dot11WNMDiag8021xAuthRprtEapVendorID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the EAP Vendor ID number for the EAP method used by the STA. The EAP Vendor ID field is included when the EAP Type field is set to 254 and is excluded otherwise." ::= { dot11WNMDiag8021xAuthReportEntry 9 } dot11WNMDiag8021xAuthRprtEapVendorType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the EAP Vendor Type number for the EAP method used by the STA. The EAP Vendor Type field is included when the EAP Type field is set to 254 and is excluded otherwise." ::= { dot11WNMDiag8021xAuthReportEntry 10 } dot11WNMDiag8021xAuthRprtCredentialType OBJECT-TYPE SYNTAX INTEGER { none(0), preSharedKey(1), userNamePassword(2), x509Certificate(3), otherCertificate(4), oneTimePassword(5), token(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the type of IEEE 802.1X credentials used by the STA for this authentication diagnostic." ::= { dot11WNMDiag8021xAuthReportEntry 11 } dot11WNMDiag8021xAuthRprtStatusCode OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the result of the authentication diagnostic and is set to one of the status codes specified in Table 9-50." ::= { dot11WNMDiag8021xAuthReportEntry 12 } -- ******************************************************************** -- * End of dot11WNMDiag8021xAuthReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMLocConfigReport TABLE -- ******************************************************************** dot11WNMLocConfigReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMLocConfigReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of location configuration reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 13 } dot11WNMLocConfigReportEntry OBJECT-TYPE SYNTAX Dot11WNMLocConfigReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMLocConfigReportTable Indexed by dot11WNMLocConfigRprtIndex." INDEX { dot11WNMLocConfigRprtIndex } ::= { dot11WNMLocConfigReportTable 1 } Dot11WNMLocConfigReportEntry ::= SEQUENCE { dot11WNMLocConfigRprtIndex Unsigned32, dot11WNMLocConfigRprtRqstToken OCTET STRING, dot11WNMLocConfigRprtIfIndex InterfaceIndex, dot11WNMLocConfigRprtLocIndParams OCTET STRING, dot11WNMLocConfigRprtLocIndChanList OCTET STRING, dot11WNMLocConfigRprtLocIndBcastRate Unsigned32, dot11WNMLocConfigRprtLocIndOptions OCTET STRING, dot11WNMLocConfigRprtStatusConfigSubelemId INTEGER, dot11WNMLocConfigRprtStatusResult INTEGER, dot11WNMLocConfigRprtVendorSpecificRprtContent OCTET STRING } dot11WNMLocConfigRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Location Configuration Report elements in dot11WNMLocConfigReportTable, greater than 0." ::= { dot11WNMLocConfigReportEntry 1 } dot11WNMLocConfigRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMLocConfigReportEntry 2 } dot11WNMLocConfigRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMLocConfig report been received on." ::= { dot11WNMLocConfigReportEntry 3 } dot11WNMLocConfigRprtLocIndParams OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates STA Location reporting characteristics. The format of these Location Indication Parameters are detailed in 9.4.2.70.2." ::= { dot11WNMLocConfigReportEntry 4 } dot11WNMLocConfigRprtLocIndChanList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..254)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute lists location indication reporting channel information for this location configuration report. Each pair of octets indicates a different Operating Class and channel number for this request. The detailed format for this list of channels as described in 9.4.2.70.3." DEFVAL { ''H } ::= { dot11WNMLocConfigReportEntry 5 } dot11WNMLocConfigRprtLocIndBcastRate OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "0.5 Mb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the data rate at which the STA broadcasts its Location Track Notification frames." ::= { dot11WNMLocConfigReportEntry 6 } dot11WNMLocConfigRprtLocIndOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the location track indication options used; see 9.4.2.70.9." ::= { dot11WNMLocConfigReportEntry 7} dot11WNMLocConfigRprtStatusConfigSubelemId OBJECT-TYPE SYNTAX INTEGER { multipleSubelemIds(0), locationIndicationParams(1), locationIndicationChannels(2), locationStatus(3), radioInformation(4), motion(5), locationIndicationBcastDataRate(6), timeOfDeparture(7), vendorSpecific(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute is set to a specific Location Parameters subelement ID transmitted in a Location Configuration Request frame. If the following StatusResult attribute field value applies to more than one subelement then the Config subelement ID is set to 0. If the Status field value applies to one subelement, then a Location Status subelement may be included in the Location Configuration Response for each configuration subelement that has a non-Success Status value." ::= { dot11WNMLocConfigReportEntry 8 } dot11WNMLocConfigRprtStatusResult OBJECT-TYPE SYNTAX INTEGER { successful(0), requestFailed(1), requestRefused(2), requestIncapable(3), detectedFrequentTransition(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the resulting status of the Location Configuration Request frame for the indicated Location Parameter subelement ID, as listed in Table 9-197, Event Report Status." ::= { dot11WNMLocConfigReportEntry 9 } dot11WNMLocConfigRprtVendorSpecificRprtContent OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute provides an envelope for all of the vendor specific subelements that may be included in Location Configuration Report element." DEFVAL { ''H } ::= { dot11WNMLocConfigReportEntry 10 } -- ******************************************************************** -- * End of dot11WNMLocConfigReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMBssTransitReport TABLE -- ******************************************************************** dot11WNMBssTransitReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMBssTransitReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of BSS Transition Management reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 14 } dot11WNMBssTransitReportEntry OBJECT-TYPE SYNTAX Dot11WNMBssTransitReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMBssTransitReportTable Indexed by dot11WNMBssTransitRprtIndex." INDEX { dot11WNMBssTransitRprtIndex } ::= { dot11WNMBssTransitReportTable 1 } Dot11WNMBssTransitReportEntry ::= SEQUENCE { dot11WNMBssTransitRprtIndex Unsigned32, dot11WNMBssTransitRprtRqstToken OCTET STRING, dot11WNMBssTransitRprtIfIndex InterfaceIndex, dot11WNMBssTransitRprtStatusCode INTEGER, dot11WNMBssTransitRprtBSSTerminationDelay Unsigned32, dot11WNMBssTransitRprtTargetBssid MacAddress, dot11WNMBssTransitRprtCandidateList OCTET STRING } dot11WNMBssTransitRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for BSS Transition Management Report elements in dot11WNMBssTransitReportTable, greater than 0." ::= { dot11WNMBssTransitReportEntry 1 } dot11WNMBssTransitRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMBssTransitReportEntry 2 } dot11WNMBssTransitRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex for this row of WNMBssTransit report been received on." ::= { dot11WNMBssTransitReportEntry 3 } dot11WNMBssTransitRprtStatusCode OBJECT-TYPE SYNTAX INTEGER { accept(0), rejectUnspecified(1), rejectInsufficientBeacons(2), rejectInsufficientCapacity(3), rejectBssTerminationUndesired(4), rejectBssTerminationDelayRequest(5), rejectBssTransitionCandidateListprovided(6), rejectNoSuitableBssTransitionCandidates(7), rejectLeavingEss(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the status of this BSS Transition report." ::= { dot11WNMBssTransitReportEntry 4 } dot11WNMBssTransitRprtBSSTerminationDelay OBJECT-TYPE SYNTAX Unsigned32 (1..255) UNITS "minutes" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the time that the responding STA requests the BSS to delay termination. This attribute is included only if the Status Code field value is set to 5." ::= { dot11WNMBssTransitReportEntry 5 } dot11WNMBssTransitRprtTargetBssid OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the target BSSID for this BSS Transition report." ::= { dot11WNMBssTransitReportEntry 6 } dot11WNMBssTransitRprtCandidateList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..11426)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute lists one or more Neighbor Report elements which are BSS transition candidates for this request. The Neighbor Report elements are described in 9.4.2.36." ::= { dot11WNMBssTransitReportEntry 7 } -- ******************************************************************** -- * End of dot11WNMBssTransitReport TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11WNMColocInterfReport TABLE -- ******************************************************************** dot11WNMColocInterfReportTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11WNMColocInterfReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains the current list of Collocated Interference reports that have been received by the MLME. The report tables shall be maintained as FIFO to preserve freshness, thus the rows in this table can be deleted for memory constraints or other implementation constraints determined by the vendor. New rows shall have different RprtIndex values than those deleted within the range limitation of the index. One easy way is to increment RprtIndex for new reports being written in the table." ::= { dot11WNMReport 16 } dot11WNMColocInterfReportEntry OBJECT-TYPE SYNTAX Dot11WNMColocInterfReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11WNMColocInterfReportTable Indexed by dot11WNMColocInterfRprtIndex." INDEX { dot11WNMColocInterfRprtIndex } ::= { dot11WNMColocInterfReportTable 1 } Dot11WNMColocInterfReportEntry ::= SEQUENCE { dot11WNMColocInterfRprtIndex Unsigned32, dot11WNMColocInterfRprtRqstToken OCTET STRING, dot11WNMColocInterfRprtIfIndex InterfaceIndex, dot11WNMColocInterfRprtPeriod Unsigned32, dot11WNMColocInterfRprtInterfLevel Integer32, dot11WNMColocInterfRprtInterfAccuracy Unsigned32, dot11WNMColocInterfRprtInterfIndex Unsigned32, dot11WNMColocInterfRprtInterfInterval Integer32, dot11WNMColocInterfRprtInterfBurstLength Integer32, dot11WNMColocInterfRprtInterfStartTime Integer32, dot11WNMColocInterfRprtInterfCenterFreq Integer32, dot11WNMColocInterfRprtInterfBandwidth Unsigned32 } dot11WNMColocInterfRprtIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for Collocated Interference Report elements in dot11WNMColocInterfReportTable, greater than 0." ::= { dot11WNMColocInterfReportEntry 1 } dot11WNMColocInterfRprtRqstToken OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request token that was indicated in the WNM request that generated this measurement report. This should be an exact match to the original dot11WNMRqstToken attribute. Note that there may be multiple entries in the table that match this value since a single request may generate multiple WNM reports." ::= { dot11WNMColocInterfReportEntry 2 } dot11WNMColocInterfRprtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. The ifIndex for this row of WNMColocInterf report been received on." ::= { dot11WNMColocInterfReportEntry 3 } dot11WNMColocInterfRprtPeriod OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "100 TU" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates how often the STA periodically reports the collocated interference. If the Report Period field is set to 0, then the reporting is not periodic, and a report is generated when the STA detects a change in the collocated interference. See 11.21.9 for further details." ::= { dot11WNMColocInterfReportEntry 4 } dot11WNMColocInterfRprtInterfLevel OBJECT-TYPE SYNTAX Integer32 (-128..127) UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the maximum level of the collocated interference power in units of dBm over all receive chains averaged over a 4 s period during an interference period and across interference bandwidth. When the interference level is unknown, the field is set to +127 dBm. When the interference level is equal or greater than 126 dBm, the field is set to +126 dBm. If no collocated interference is present the field is set to -128 dBm. When the interference level is equal or lower than -127 dBm, the field is set to -127 dBm. The interference level is referenced to the antenna connector (see definition in Clause 3) used for reception, like RCPI." ::= { dot11WNMColocInterfReportEntry 5 } dot11WNMColocInterfRprtInterfAccuracy OBJECT-TYPE SYNTAX Unsigned32 (0..15) UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the expected accuracy of the estimate of interference in dB with 95% confidence interval. If the Interference Level field is X (dBm) and the expected accuracy field is Y (dB), the actual interference level is in the range X - Y to X +Y with the probability of 95%. If the accuracy is unknown then the Expected Accuracy field is set to 15." ::= { dot11WNMColocInterfReportEntry 6 } dot11WNMColocInterfRprtInterfIndex OBJECT-TYPE SYNTAX Unsigned32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the interference index that is unique for each type of interference source. The field set to 0 indicates that no collocated interference is present. See 11.21.9 for further details." ::= { dot11WNMColocInterfReportEntry 7 } dot11WNMColocInterfRprtInterfInterval OBJECT-TYPE SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the interval between two successive periods of interference. When the interval between two successive periods of interference is variable the field is set to 2^32-1. When the interval between two successive periods of interference is equal or greater than 2**32-2 the field is set to 2^32-2. If no collocated interference is present the field is set to 0." ::= { dot11WNMColocInterfReportEntry 8 } dot11WNMColocInterfRprtInterfBurstLength OBJECT-TYPE SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the duration of each period of interference. When the duration of each period of interference is variable the field is set to 2^32-1). When the duration of each period of interference is equal or greater than 2^32-2, the field is set to 2^32-2. If no collocated interference is present the field is set to 0." ::= { dot11WNMColocInterfReportEntry 9 } dot11WNMColocInterfRprtInterfStartTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute contains the least significant 4 octets (i.e., B0-B31) of the TSF timer at the start of the interference burst. When either the Interference Interval or the Interference Burst Length fields are set to 2^32-1, this field indicates the average duty cycle. The average duty cycle value is defined as Floor((2^32-2) * [average interference burst length (microsecond)]/[average interference interval (microsecond)] + 0.5). When the interference is nonperiodic the Interference Start Time field is set to 0. If no collocated interference is present the field is set to 0." ::= { dot11WNMColocInterfReportEntry 10 } dot11WNMColocInterfRprtInterfCenterFreq OBJECT-TYPE SYNTAX Integer32 UNITS "5 kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates center frequency of interference. When center frequency is unknown, the center frequency of the STA's operating channel is reported. If no collocated interference is present the field is set to 0." ::= { dot11WNMColocInterfReportEntry 11 } dot11WNMColocInterfRprtInterfBandwidth OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "5 kHz" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the bandwidth at the -3 dB roll-off point of the interference signal. When bandwidth of the interference signal is unknown, the field is set to 65 535. When bandwidth of the interference signal is equal or greater than 65 534 the field is set to 65 534. If no collocated interference is present the field is set to 0." ::= { dot11WNMColocInterfReportEntry 12 } -- ******************************************************************** -- * End of dot11WNMColocInterfReport TABLE -- ******************************************************************** -- ******************************************************************** -- * END of Wireless Network Management Interface MIB -- ******************************************************************** -- ********************************************************************** -- * END of IEEE 802.11 RM and WNM Interface MIB -- ********************************************************************** -- ********************************************************************** -- * dot11MeshSTAConfig TABLE -- ********************************************************************** dot11MeshSTAConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11MeshSTAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mesh Station Configuration attributes. In tabular form to allow for multiple instances on an agent." ::= { dot11smt 23 } dot11MeshSTAConfigEntry OBJECT-TYPE SYNTAX Dot11MeshSTAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11MeshStationConfigTable. It is possible for there to be multiple IEEE 802.11 interfaces on one agent, each with its unique MAC address. The relationship between an IEEE 802.11 interface and an interface in the context of the Internet-standard MIB is one-to-one. As such, the value of an ifIndex object instance can be directly used to identify corresponding instances of the objects defined herein. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11MeshSTAConfigTable 1 } Dot11MeshSTAConfigEntry ::= SEQUENCE { dot11MeshID OCTET STRING, dot11MeshNumberOfPeerings Unsigned32, dot11MeshAcceptingAdditionalPeerings TruthValue, dot11MeshConnectedToMeshGate TruthValue, dot11MeshSecurityActivated TruthValue, dot11MeshActiveAuthenticationProtocol INTEGER, dot11MeshMaxRetries Unsigned32, dot11MeshRetryTimeout Unsigned32, dot11MeshConfirmTimeout Unsigned32, dot11MeshHoldingTimeout Unsigned32, dot11MeshConfigGroupUpdateCount Unsigned32, dot11MeshActivePathSelectionProtocol INTEGER, dot11MeshActivePathSelectionMetric INTEGER, dot11MeshForwarding TruthValue, dot11MeshTTL Unsigned32, dot11MeshGateAnnouncements TruthValue, dot11MeshGateAnnouncementInterval Unsigned32, dot11MeshActiveCongestionControlMode INTEGER, dot11MeshActiveSynchronizationMethod INTEGER, dot11MeshNbrOffsetMaxNeighbor Unsigned32, dot11MBCAActivated TruthValue, dot11MeshBeaconTimingReportInterval Unsigned32, dot11MeshBeaconTimingReportMaxNum Unsigned32, dot11MeshDelayedBeaconTxInterval Unsigned32, dot11MeshDelayedBeaconTxMaxDelay Unsigned32, dot11MeshDelayedBeaconTxMinDelay Unsigned32, dot11MeshAverageBeaconFrameDuration Unsigned32, dot11MeshSTAMissingAckRetryLimit Unsigned32, dot11MeshAwakeWindowDuration Unsigned32, dot11MCCAImplemented TruthValue, dot11MCCAActivated TruthValue, dot11MAFlimit Unsigned32, dot11MCCAScanDuration Unsigned32, dot11MCCAAdvertPeriodMax Unsigned32, dot11MCCATrackStatesCapable Unsigned32, dot11MCCATrackStatesActive Unsigned32, dot11MCCAOPtimeout Unsigned32, dot11MCCACWmin Unsigned32, dot11MCCACWmax Unsigned32, dot11MCCAAIFSN Unsigned32 } dot11MeshID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute reflects the Mesh ID configured in this entity." ::= { dot11MeshSTAConfigEntry 1 } dot11MeshNumberOfPeerings OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the number of mesh peering currently maintained by the STA. This value is reflected in the Number of Peerings subfield in the Mesh Formation Info field in the Mesh Configuration element." ::= { dot11MeshSTAConfigEntry 2 } dot11MeshAcceptingAdditionalPeerings OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates whether the station is willing to accept additional peerings. This value is reflected in the Accepting Additional Mesh Peerings subfield in the Mesh Capability field in the Mesh Configuration element." ::= { dot11MeshSTAConfigEntry 3 } dot11MeshConnectedToMeshGate OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates whether the station has a mesh path to a mesh gate. This value is reflected in the Connected to Mesh Gate subfield in the Mesh Formation Info field in the Mesh Configuration element." ::= { dot11MeshSTAConfigEntry 4 } dot11MeshSecurityActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies whether the station is security enabled." ::= { dot11MeshSTAConfigEntry 5 } dot11MeshActiveAuthenticationProtocol OBJECT-TYPE SYNTAX INTEGER { null (0), sae (1), ieee8021x (2), vendorSpecific (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies the active authentication protocol." DEFVAL { null } ::= { dot11MeshSTAConfigEntry 6 } dot11MeshMaxRetries OBJECT-TYPE SYNTAX Unsigned32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum number of Mesh Peering Open retries that can be sent to establish a new mesh peering instance in a mesh BSS." DEFVAL { 2 } ::= { dot11MeshSTAConfigEntry 7 } dot11MeshRetryTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..255) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the initial retry timeout used by the Mesh Peering Open message." DEFVAL { 40 } ::= { dot11MeshSTAConfigEntry 8 } dot11MeshConfirmTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..255) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the initial retry timeout used by the Mesh Peering Open message." DEFVAL { 40 } ::= { dot11MeshSTAConfigEntry 9 } dot11MeshHoldingTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..255) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the confirm timeout used by the mesh peering management to close a mesh peering." DEFVAL { 40 } ::= { dot11MeshSTAConfigEntry 10 } dot11MeshConfigGroupUpdateCount OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies how many times the Mesh Group Key Inform frame will be retried per mesh group key handshake attempt." DEFVAL { 3 } ::= { dot11MeshSTAConfigEntry 11 } dot11MeshActivePathSelectionProtocol OBJECT-TYPE SYNTAX INTEGER { hwmp (1), vendorSpecific (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies the active path selection protocol." DEFVAL { hwmp } ::= { dot11MeshSTAConfigEntry 12 } dot11MeshActivePathSelectionMetric OBJECT-TYPE SYNTAX INTEGER { airtimeLinkMetric (1), highPHYRateAirtimeLinkMetric (2), vendorSpecific (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies the active path selection metric." DEFVAL { airtimeLinkMetric } ::= { dot11MeshSTAConfigEntry 13 } dot11MeshForwarding OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the ability of a mesh STA to forward MSDUs." DEFVAL { true } ::= { dot11MeshSTAConfigEntry 14 } dot11MeshTTL OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the value of Mesh TTL subfield set at a source mesh STA." DEFVAL { 31 } ::= { dot11MeshSTAConfigEntry 15 } dot11MeshGateAnnouncements OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies whether the mesh STA activates mesh gate announcements." DEFVAL { false } ::= { dot11MeshSTAConfigEntry 16 } dot11MeshGateAnnouncementInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the gate announcement interval. The gate announcement interval is the number of seconds between the transmission of two gate announcements." DEFVAL { 10 } ::= { dot11MeshSTAConfigEntry 17 } dot11MeshActiveCongestionControlMode OBJECT-TYPE SYNTAX INTEGER { null (0), congestionControlSignaling (1), vendorSpecific (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies the active congestion control protocol." DEFVAL { null } ::= { dot11MeshSTAConfigEntry 18 } dot11MeshActiveSynchronizationMethod OBJECT-TYPE SYNTAX INTEGER { neighborOffsetSynchronization (1), vendorSpecific (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies the MBSS's active synchronization method." DEFVAL { neighborOffsetSynchronization } ::= { dot11MeshSTAConfigEntry 19 } dot11MeshNbrOffsetMaxNeighbor OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute specifies the maximum number of neighbor STAs with which the mesh STA maintains synchronization using the neighbor offset synchronization method." ::= { dot11MeshSTAConfigEntry 20 } dot11MBCAActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies whether the station activates mesh beacon collision avoidance mechanisms." DEFVAL { false } ::= { dot11MeshSTAConfigEntry 21 } dot11MeshBeaconTimingReportInterval OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. This attribute specifies when the Beacon Timing element is present in Beacon frames. The Beacon Timing element is present when the DTIM Count value in the Beacon frame is zero or equal to an integer multiple of the set value." DEFVAL { 4 } ::= { dot11MeshSTAConfigEntry 22 } dot11MeshBeaconTimingReportMaxNum OBJECT-TYPE SYNTAX Unsigned32 (0..50) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum number of the Beacon Timing Information field contained in a Beacon Timing element in the transmitting Beacon frames." DEFVAL { 16 } ::= { dot11MeshSTAConfigEntry 23 } dot11MeshDelayedBeaconTxInterval OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the interval of the delayed beacon transmission for the purpose of MBCA. The value is expressed in units of Beacon Interval. The value 0 indicates that the delayed beacon transmission is disabled." DEFVAL { 0 } ::= { dot11MeshSTAConfigEntry 24 } dot11MeshDelayedBeaconTxMaxDelay OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum delay time from a TBTT of delayed beacon transmissions for the purpose of MBCA." DEFVAL { 2048 } ::= { dot11MeshSTAConfigEntry 25 } dot11MeshDelayedBeaconTxMinDelay OBJECT-TYPE SYNTAX Unsigned32 (0..4023) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the minimum delay time from a TBTT of delayed beacon transmissions for the purpose of MBCA." DEFVAL { 0 } ::= { dot11MeshSTAConfigEntry 26 } dot11MeshAverageBeaconFrameDuration OBJECT-TYPE SYNTAX Unsigned32 (0..16383) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the average duration of the last 16 Beacon frames of other mesh STAs received by this mesh STA." ::= { dot11MeshSTAConfigEntry 27 } dot11MeshSTAMissingAckRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of times the mesh STA may retry a frame for which it does not receive an Ack frame for a STA in power save mode after the mesh STA does not receive an Ack frame to an individually addressed MPDU sent with the EOSP subfield set to 1." ::= { dot11MeshSTAConfigEntry 28 } dot11MeshAwakeWindowDuration OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the duration of the mesh Awake Window in TUs. This value is reflected in the value of the Mesh Awake Window element." ::= { dot11MeshSTAConfigEntry 29 } dot11MCCAImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute specifies whether the MCCA is implemented in this station." ::= { dot11MeshSTAConfigEntry 30 } dot11MCCAActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies whether the station is MCCA enabled." DEFVAL { false } ::= { dot11MeshSTAConfigEntry 31 } dot11MAFlimit OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "1/255" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum MCCA access fraction allowed at the mesh STA." DEFVAL { 128 } ::= { dot11MeshSTAConfigEntry 32 } dot11MCCAScanDuration OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the duration after the activation of MCCA that the mesh STA shall not initiate or accept MCCAOP Setup Requests." DEFVAL { 3200 } -- (2 ^ 5) * 100 ::= { dot11MeshSTAConfigEntry 33 } dot11MCCAAdvertPeriodMax OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "DTIM intervals" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum interval that a mesh STA with dot11MCCAActivated equal to true waits for an MCCAOP advertisement." DEFVAL { 1 } ::= { dot11MeshSTAConfigEntry 34 } dot11MCCATrackStatesCapable OBJECT-TYPE SYNTAX Unsigned32 (83..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute specifies the number of MCCAOP reservations that the MAC entity is able to track." ::= { dot11MeshSTAConfigEntry 35 } dot11MCCATrackStatesActive OBJECT-TYPE SYNTAX Unsigned32 (83..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The upper bound is given by the current value of dot11MCCATrackStatesCapable. This attribute specifies the maximum number of MCCAOP reservations that the MAC entity is able to track." DEFVAL { 83 } ::= { dot11MeshSTAConfigEntry 36 } dot11MCCAOPtimeout OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the timeout value for an MCCAOP teardown." DEFVAL { 10000 } ::= { dot11MeshSTAConfigEntry 37 } dot11MCCACWmin OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the value of the minimum size of the window that shall be used by the mesh STA during the MCCAOP for which it is the MCCAOP owner for generating a random number for the backoff." DEFVAL { 0 } ::= { dot11MeshSTAConfigEntry 38 } dot11MCCACWmax OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the value of the maximum size of the window that shall be used by the mesh STA during the MCCAOP for which it is the MCCAOP owner for generating a random number for the backoff. The value of this attribute shall be such that it could always be expressed in the form of 2^X - 1, where X is an integer." DEFVAL { 31 } ::= { dot11MeshSTAConfigEntry 39 } dot11MCCAAIFSN OBJECT-TYPE SYNTAX Unsigned32 (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of slots, after a SIFS, that the mesh STA shall sense the medium idle either before transmitting or executing a backoff during an MCCAOP for which it is the MCCAOP owner." DEFVAL { 1 } ::= { dot11MeshSTAConfigEntry 40 } -- ********************************************************************** -- * End of dot11MeshSTAConfig TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11MeshHWMPConfig TABLE -- ********************************************************************** dot11MeshHWMPConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11MeshHWMPConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mesh Station HWMP Configuration attributes. In tabular form to allow for multiple instances on an agent." ::= { dot11smt 24 } dot11MeshHWMPConfigEntry OBJECT-TYPE SYNTAX Dot11MeshHWMPConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11MeshHWMPConfigTable. It is possible for there to be multiple IEEE 802.11 interfaces on one agent, each with its unique MAC address. The relationship between an IEEE 802.11 interface and an interface in the context of the Internet-standard MIB is one-to-one. As such, the value of an ifIndex object instance can be directly used to identify corresponding instances of the objects defined herein. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11MeshHWMPConfigTable 1 } Dot11MeshHWMPConfigEntry ::= SEQUENCE { dot11MeshHWMPmaxPREQretries Unsigned32, dot11MeshHWMPnetDiameter Unsigned32, dot11MeshHWMPnetDiameterTraversalTime Unsigned32, dot11MeshHWMPpreqMinInterval Unsigned32, dot11MeshHWMPperrMinInterval Unsigned32, dot11MeshHWMPactivePathToRootTimeout Unsigned32, dot11MeshHWMPactivePathTimeout Unsigned32, dot11MeshHWMProotMode INTEGER, dot11MeshHWMProotInterval Unsigned32, dot11MeshHWMPrannInterval Unsigned32, dot11MeshHWMPtargetOnly INTEGER, dot11MeshHWMPmaintenanceInterval Unsigned32, dot11MeshHWMPconfirmationInterval Unsigned32 } dot11MeshHWMPmaxPREQretries OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of Action frames containing a PREQ element that an originator mesh STA can send to a particular path target for a specific path discovery." DEFVAL { 3 } ::= { dot11MeshHWMPConfigEntry 1} dot11MeshHWMPnetDiameter OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the estimate of the maximum number of hops that it takes for an HWMP element to propagate across the mesh BSS." DEFVAL { 31 } ::= { dot11MeshHWMPConfigEntry 2} dot11MeshHWMPnetDiameterTraversalTime OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the estimate of the interval of time that it takes for an HWMP element to propagate across the mesh BSS." DEFVAL { 500 } ::= { dot11MeshHWMPConfigEntry 3} dot11MeshHWMPpreqMinInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the minimum interval of time during which a mesh STA can send only one Action frame containing a PREQ element." DEFVAL { 100 } ::= { dot11MeshHWMPConfigEntry 4} dot11MeshHWMPperrMinInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the minimum interval of time during which a mesh STA can send only one Action frame containing a PERR element." DEFVAL { 100 } ::= { dot11MeshHWMPConfigEntry 5} dot11MeshHWMPactivePathToRootTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object shall specify the time for which mesh STAs receiving a proactive PREQ element shall consider the forwarding information to the root mesh STA to be valid; it needs to be greater than dot11MeshHWMProotInterval." DEFVAL { 5000 } ::= { dot11MeshHWMPConfigEntry 6} dot11MeshHWMPactivePathTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the time for which mesh STAs receiving a PREQ element to individual target(s) shall consider the forwarding information to be valid." DEFVAL { 5000 } ::= { dot11MeshHWMPConfigEntry 7} dot11MeshHWMProotMode OBJECT-TYPE SYNTAX INTEGER { noRoot(0), proactivePREQnoPREP(2), proactivePREQwithPREP(3), rann(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute controls the configuration of a mesh STA as root mesh STA. A mesh STA is configured as a root mesh STA if dot11MeshHWMProotMode is set to 2, 3 or 4. Different values correspond to different modes of the root mesh STA. The mesh STA is not a root mesh STA when the attribute is set to 0." DEFVAL { noRoot } ::= { dot11MeshHWMPConfigEntry 8} dot11MeshHWMProotInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the minimum interval of time during which a root mesh STA can send only one Action frame containing a proactive PREQ element." DEFVAL { 2000 } ::= { dot11MeshHWMPConfigEntry 9} dot11MeshHWMPrannInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the minimum interval of time during which a mesh STA can send only one Action frame containing a RANN element." DEFVAL { 2000 } ::= { dot11MeshHWMPConfigEntry 10} dot11MeshHWMPtargetOnly OBJECT-TYPE SYNTAX INTEGER { intermediateMSTA(0), targetOnly(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when set to intermediateMSTA (0), allows intermediate mesh STAs to respond with a PREP element to a PREQ element if they have valid forwarding information to the requested target. When set to targetOnly (1), only the target mesh STA is allowed to respond with a PREP element to a PREQ element." DEFVAL { targetOnly } ::= { dot11MeshHWMPConfigEntry 11} dot11MeshHWMPmaintenanceInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the minimum interval of time during which a mesh STA can send only one Action frame containing a PREQ element for path maintenance." DEFVAL { 2000 } ::= { dot11MeshHWMPConfigEntry 12} dot11MeshHWMPconfirmationInterval OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the minimum interval of time during which a mesh STA can send only one Action frame containing a PREQ element for root path confirmation." DEFVAL { 2000 } ::= { dot11MeshHWMPConfigEntry 13} -- ******************************************************************** -- * End of dot11MeshHWMPConfig TABLE -- ******************************************************************** -- ******************************************************************* -- * dot11RSNAConfigPasswordValue TABLE -- ******************************************************************* dot11RSNAConfigPasswordValueTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RSNAConfigPasswordValueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "When SAE authentication is the selected AKM suite, this table is used to locate the binary representation of a shared, secret, and potentially low-entropy word, phrase, code, or key that will be used as the authentication credential between a TA/RA pair. This table is logically write-only. Reading this table returns unsuccessful status or null or zero." ::= { dot11smt 25 } dot11RSNAConfigPasswordValueEntry OBJECT-TYPE SYNTAX Dot11RSNAConfigPasswordValueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the Password Value Table" INDEX { dot11RSNAConfigPasswordValueIndex } ::= { dot11RSNAConfigPasswordValueTable 1 } Dot11RSNAConfigPasswordValueEntry ::= SEQUENCE { dot11RSNAConfigPasswordValueIndex Unsigned32, dot11RSNAConfigPasswordCredential OCTET STRING, dot11RSNAConfigPasswordIdentifier OCTET STRING, dot11RSNAConfigPasswordPeerMac MacAddress} dot11RSNAConfigPasswordValueIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the Password Value table." ::= { dot11RSNAConfigPasswordValueEntry 1 } dot11RSNAConfigPasswordCredential OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable is an octet string representation of a shared, secret, and potentially low-entropy word, phrase, code or key used as an authentication credential. Any character-based word or phrase shall be converted into a canonical representation according to 12.4.3 before populating the Password Credential." ::= { dot11RSNAConfigPasswordValueEntry 2 } dot11RSNAConfigPasswordIdentifier OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable is an octet string that an implementation uses to uniquely identify a password to support provisioning multiple passwords for a single peer MAC entity. It shall be converted into a canonical representation according to 12.4.3 (Representation of a password) before populating the Password Identifier." ::= { dot11RSNAConfigPasswordValueEntry 3 } dot11RSNAConfigPasswordPeerMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable represents the MAC address of the peer that is to be authenticated. A wildcard BSSID is permitted when passwords are shared among peers." ::= { dot11RSNAConfigPasswordValueEntry 4} -- ******************************************************************* -- * End of dot11RSNAConfigPasswordValue TABLE -- ******************************************************************* -- ******************************************************************* -- * dot11RSNAConfigDLCGroup TABLE -- ******************************************************************* dot11RSNAConfigDLCGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RSNAConfigDLCGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table gives a prioritized list of domain parameter set Identifiers for discrete logarithm cryptography (DLC) groups." ::= { dot11smt 26 } dot11RSNAConfigDLCGroupEntry OBJECT-TYPE SYNTAX Dot11RSNAConfigDLCGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the DLC Group Table." INDEX { dot11RSNAConfigDLCGroupIndex } ::= { dot11RSNAConfigDLCGroupTable 1 } Dot11RSNAConfigDLCGroupEntry ::= SEQUENCE { dot11RSNAConfigDLCGroupIndex Unsigned32, dot11RSNAConfigDLCGroupIdentifier Unsigned32 } dot11RSNAConfigDLCGroupIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The variable used to identify instances of the columnar objects in the DLC Group Table. Entries are sorted based on the Group Index according to the priority of the Group Identifier relative to other objects. More preferred Group Identifiers will have a lower index in the Group Entry." ::= { dot11RSNAConfigDLCGroupEntry 1 } dot11RSNAConfigDLCGroupIdentifier OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This variable uniquely identifies a domain parameter set for a group in the repository maintained by IANA as `Group Description' attributes for IETF RFC 2409 (IKE)[B14][B30]." ::= { dot11RSNAConfigDLCGroupEntry 2 } -- ********************************************************************* -- * End of dot11RSNAConfigDLCGroup TABLE -- ********************************************************************* -- ******************************************************************* -- * dot11DMGSTAConfigTable TABLE -- ******************************************************************* dot11DMGSTAConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11DMGSTAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table management object. The dot11DMGSTAConfig Table" ::= { dot11smt 27 } dot11DMGSTAConfigEntry OBJECT-TYPE SYNTAX Dot11DMGSTAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry in the dot11DMGSTAConfig Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11DMGSTAConfigTable 1 } Dot11DMGSTAConfigEntry ::= SEQUENCE { dot11DMGOptionImplemented TruthValue, dot11RelayActivated TruthValue, dot11REDSActivated TruthValue, dot11RDSActivated TruthValue, dot11MultipleMACActivated TruthValue, dot11ClusteringActivated TruthValue } dot11DMGOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. DMG Capable Object This attribute, when true, indicates the STA is DMG capable. This attribute, when false, indicates the STA is not DMG capable." ::= { dot11DMGSTAConfigEntry 1 } dot11RelayActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates the DMG STA is Relay capable. This attribute, when false, indicates the STA is not Relay capable." ::= { dot11DMGSTAConfigEntry 2 } dot11REDSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates the DMG STA is capable of operating as a REDS. This attribute, when false, indicates the STA is not capable of operating as a REDS." ::= { dot11DMGSTAConfigEntry 3 } dot11RDSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates the DMG STA is capable of operating as a RDS. This attribute, when false, indicates the STA is not capable of operating as a RDS." ::= { dot11DMGSTAConfigEntry 4 } dot11MultipleMACActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. If dot11MultipleMACActivated is true, the STA is capable of managing more than one MAC address." ::= { dot11DMGSTAConfigEntry 5 } dot11ClusteringActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. If dot11ClusteringActivated is true, the STA is capable of supporting AP or PCP Clustering." ::= { dot11DMGSTAConfigEntry 6 } -- ******************************************************************* -- * End of dot11DMGSTAConfigTable TABLE -- ******************************************************************* -- ********************************************************************** -- * dot11AVOptions TABLE -- ********************************************************************** dot11AVOptionsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11AVOptionsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "AV streaming attributes. In tabular form to allow for multiple instances on an agent. This table applies to the interface only if dot11RobustAVStreamingImplemented is true in the dot11StationConfigTable. Otherwise this table should be ignored." ::= { dot11smt 28 } dot11AVOptionsEntry OBJECT-TYPE SYNTAX Dot11AVOptionsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11AVOptionsTable. For all AV Streaming features, an Activated MIB attribute is used to activate/enable or deactivate/disable the corresponding feature. An Implemented MIB attribute is used for an optional feature to indicate whether the feature is implemented. A mandatory feature does not have a corresponding Implemented MIB attribute. It is possible for there to be multiple IEEE 802.11 interfaces on one agent, each with its unique MAC address. The relationship between an IEEE 802.11 interface and an interface in the context of the Internet-standard MIB is one-to-one. As such, the value of an ifIndex object instance can be directly used to identify corresponding instances of the objects defined herein. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11AVOptionsTable 1 } Dot11AVOptionsEntry ::= SEQUENCE { dot11GCRActivated TruthValue, dot11AdvancedGCRImplemented TruthValue, dot11AdvancedGCRActivated TruthValue, dot11SCSImplemented TruthValue, dot11SCSActivated TruthValue, dot11QLoadReportActivated TruthValue, dot11AlternateEDCAActivated TruthValue, dot11GCRGroupMembershipAnnouncementActivated TruthValue, dot11PublicHCCATXOPNegotiationImplemented TruthValue, dot11PublicHCCATXOPNegotiationActivated TruthValue, dot11ProtectedHCCATXOPNegotiationImplemented TruthValue, dot11ProtectedHCCATXOPNegotiationActivated TruthValue, dot11ProtectedQLoadReportImplemented TruthValue, dot11ProtectedQLoadReportActivated TruthValue, dot11MeshGCRImplemented TruthValue, dot11MeshGCRActivated TruthValue } dot11GCRActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that the station implementation supports the GCR procedures as defined in 11.21.16.3 and that this has been activated." DEFVAL { false } ::= { dot11AVOptionsEntry 1 } dot11AdvancedGCRImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation supports the Advanced GCR features." ::= { dot11AVOptionsEntry 2 } dot11AdvancedGCRActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that the station implementation supports the GCR procedures as defined in 11.21.16.3 and that this has been activated." DEFVAL { false } ::= { dot11AVOptionsEntry 3 } dot11SCSImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation supports the stream classification service." ::= { dot11AVOptionsEntry 4 } dot11SCSActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that the station implementation supports the stream classification service and that this has been activated." DEFVAL { false } ::= { dot11AVOptionsEntry 5 } dot11QLoadReportActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive. This attribute, when true, indicates that the AP performs the QLoad report procedures described in 11.26.2." DEFVAL { false } ::= { dot11AVOptionsEntry 6 } dot11AlternateEDCAActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive. This attribute, when true, indicates that the station can additionally use the Alternate EDCA transmit queues." DEFVAL { false } ::= { dot11AVOptionsEntry 7 } dot11GCRGroupMembershipAnnouncementActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the STA sends unsolicited Group Membership Response frames when its dot11GroupAddressesTable changes." DEFVAL { false } ::= { dot11AVOptionsEntry 8 } dot11PublicHCCATXOPNegotiationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation supports the negotiation of HCCA TXOPs using Public Action frames." ::= { dot11AVOptionsEntry 9 } dot11PublicHCCATXOPNegotiationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive. This attribute, when true, indicates that the AP can negotiate HCCA TXOPs using Public Action frames." DEFVAL { true } ::= { dot11AVOptionsEntry 10 } dot11ProtectedHCCATXOPNegotiationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation supports the negotiation of HCCA TXOPs using Protected Dual of Public Action frames." ::= { dot11AVOptionsEntry 11 } dot11ProtectedHCCATXOPNegotiationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive. This attribute, when true, indicates that the AP can negotiate HCCA TXOPs using Protected Dual of Public Action frames." DEFVAL { true } ::= { dot11AVOptionsEntry 12 } dot11ProtectedQLoadReportImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation supports the reporting of QLoad using Protected Dual of Public Action frames." ::= { dot11AVOptionsEntry 13 } dot11ProtectedQLoadReportActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive. This attribute, when true, indicates that the AP can report QLoad using Protected Dual of Public Action frames." DEFVAL { true } ::= { dot11AVOptionsEntry 14 } dot11MeshGCRImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the mesh station implementation supports the Advanced GCR features." ::= { dot11AVOptionsEntry 15 } dot11MeshGCRActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute, when true, indicates that the mesh station implementation supports the GCR procedures as defined in 11.21.16.3 and that this has been activated." DEFVAL { false } ::= { dot11AVOptionsEntry 16 } -- ********************************************************************** -- * End of dot11AVOptions TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11AVConfig TABLE -- ********************************************************************** dot11AVConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11AVConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "AV streaming attributes. In tabular form to allow for multiple instances on an agent. This table only applies to the interface if dot11RobustAVStreamingImplemented is true in the dot11StationConfigTable. Otherwise this table should be ignored." ::= { dot11smt 29 } dot11AVConfigEntry OBJECT-TYPE SYNTAX Dot11AVConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11AVConfigTable. It is possible for there to be multiple IEEE 802.11 interfaces on one agent, each with its unique MAC address. The relationship between an IEEE 802.11 interface and an interface in the context of the Internet-standard MIB is one-to-one. As such, the value of an ifIndex object instance can be directly used to identify corresponding instances of the objects defined herein. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11AVConfigTable 1 } Dot11AVConfigEntry ::= SEQUENCE { dot11GCRPolicyChangeTimeout Unsigned32, dot11QLoadReportIntervalDTIM Unsigned32, dot11HCCATXOPBeaconTimeout Unsigned32, dot11GCRConcealmentAddress MacAddress, dot11QLoadReportDelay Unsigned32, dot11ShortDEIRetryLimit Unsigned32, dot11LongDEIRetryLimit Unsigned32, dot11UnsolicitedRetryLimit Unsigned32, dot11DefaultSurplusBandwidthAllowance Unsigned32 } dot11GCRPolicyChangeTimeout OBJECT-TYPE SYNTAX Unsigned32 (5..18000) UNITS "100 TUs" MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. Changes take effect for the next MLME-START.request primitive or MLME-JOIN.request primitive. This attribute indicates the interval after which a STA updates its GCR delivery mode or retransmission policy state using the procedures defined in 11.21.16.3.4." DEFVAL { 100 } ::= { dot11AVConfigEntry 1 } dot11QLoadReportIntervalDTIM OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect at the next MLME-START.request primitive. This attribute describes the number of DTIM intervals between transmissions of Beacon frames containing a Qload Report element." ::= { dot11AVConfigEntry 2 } dot11HCCATXOPBeaconTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC or external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies the number of beacon periods an AP defers scheduling new potentially conflicting HCCA TXOPs while performing the HCCA TXOP procedures defined in 11.26.3." DEFVAL { 3 } ::= { dot11AVConfigEntry 3 } dot11GCRConcealmentAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or external management entity. In a non-AP STA or mesh STA receiving GCR service, it is written by the MAC when it receives a DMS Response frame that contains a DMS Status field with a GCR Response subelement and a Response Type subfield set to Accept. In an AP or mesh STA providing GCR service, changes take effect for the next MLME-START.request primitive. In a non-AP STA or mesh STA receiving GCR service, changes take effect as soon as practical in the implementation. The purpose of dot11GCRConcealmentAddress is to define the group address that is used by the GCR procedures (as defined in 11.21.16.3.5) to conceal group addressed frames from STAs that do not support GCR." DEFVAL {'010FAC474352'H} ::= { dot11AVConfigEntry 4 } dot11QLoadReportDelay OBJECT-TYPE SYNTAX Unsigned32 (1..60) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect at the next MLME-START.request primitive. This attribute describes the maximum number of seconds an AP delays sending an unsolicited QLoad Report action frame." DEFVAL { 10 } ::= { dot11AVConfigEntry 5 } dot11ShortDEIRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum number of transmission attempts that are made before a failure condition is indicated." DEFVAL { 5 } ::= { dot11AVConfigEntry 6 } dot11LongDEIRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the long retry counter (QLDRC) associated with this MIB variable has been deleted. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. For frames where the DEI subfield has the value of one and length greater than dot11RTSThreshold, this attribute indicates the maximum number of transmission attempts that are made before a failure condition is indicated." DEFVAL { 3 } ::= { dot11AVConfigEntry 7 } dot11UnsolicitedRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum number of transmission attempts of a frame delivered using the GCR unsolicited retry retransmission policy." DEFVAL { 7 } ::= { dot11AVConfigEntry 8 } dot11DefaultSurplusBandwidthAllowance OBJECT-TYPE SYNTAX Unsigned32 (100..255) MAX-ACCESS read-write STATUS current DESCRIPTION " This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This object specifies the default percentage surplus bandwidth allowance when calculating medium time. " DEFVAL { 110 } ::= { dot11AVConfigEntry 9 } -- ******************************************************************** -- * End of dot11AVConfig TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11APC TABLE -- ******************************************************************** dot11APCTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11APCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains conceptual table of attributes for MIB-based HCCA TXOP negotiation." ::= { dot11smt 30 } dot11APCTableEntry OBJECT-TYPE SYNTAX Dot11APCEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11APCTable, Indexed by dot11APCIndex." INDEX { dot11APCIndex } ::= { dot11APCTable 1 } Dot11APCEntry ::= SEQUENCE { dot11APCIndex Unsigned32, dot11APCEntryAvoidanceDuration Unsigned32, dot11APCEntryAvoidanceServiceInterval Unsigned32, dot11APCEntryAvoidanceOffset Unsigned32, dot11APCEntryMACAddress MacAddress } dot11APCIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the HCCA TXOP Table." ::= { dot11APCTableEntry 1 } dot11APCEntryAvoidanceDuration OBJECT-TYPE SYNTAX Unsigned32 (0..131071) UNITS "32 microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the duration of a TXOP reservation that the AP attempts to avoid when scheduling new HCCA TXOPs." ::= { dot11APCTableEntry 2 } dot11APCEntryAvoidanceServiceInterval OBJECT-TYPE SYNTAX Unsigned32 (0..255) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the duration of the period between successive HCCA TXOPs. When zero, no period has been reserved." ::= { dot11APCTableEntry 3 } dot11APCEntryAvoidanceOffset OBJECT-TYPE SYNTAX Unsigned32 (0..131071) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the offset from the scheduled start of the Beacon transmission until the start of the time period for a TXOP reservation that the AP attempts to avoid when scheduling new HCCA TXOPs." ::= { dot11APCTableEntry 4 } dot11APCEntryMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the MAC address of the peer AP that has scheduled an HCCA TXOP in the time period defined by dot11APCEntryAvoidanceDuration, dot11APCEntryAvoidanceServiceInterval, and dot11APCEntryAvoidanceOffset." ::= { dot11APCTableEntry 5 } -- ******************************************************************** -- * End of dot11APC TABLE -- ******************************************************************** -- ********************************************************************* -- * dot11VHTStationConfig TABLE -- ********************************************************************** dot11VHTStationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11VHTStationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Station Configuration attributes. In tabular form to allow for multiple instances on an agent." ::= { dot11smt 31 } dot11VHTStationConfigEntry OBJECT-TYPE SYNTAX Dot11VHTStationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the dot11VHTStationConfig Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11VHTStationConfigTable 1 } Dot11VHTStationConfigEntry ::= SEQUENCE { dot11MaxMPDULength INTEGER, dot11VHTMaxRxAMPDUFactor Unsigned32, dot11VHTControlFieldOptionImplemented TruthValue, dot11VHTTXOPPowerSaveOptionImplemented TruthValue, dot11VHTRxVHTMCSMap OCTET STRING, dot11VHTRxHighestDataRateSupported Unsigned32, dot11VHTTxVHTMCSMap OCTET STRING, dot11VHTTxHighestDataRateSupported Unsigned32, dot11VHTOBSSScanCount Unsigned32 } dot11MaxMPDULength OBJECT-TYPE SYNTAX INTEGER { short(3895), medium(7991), long(11454) } UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum supported size of an MPDU received in a VHT PPDU." ::= { dot11VHTStationConfigEntry 1 } dot11VHTMaxRxAMPDUFactor OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum length of A-MPDU that the STA can receive. The Maximum Rx A-MPDU defined by this field is equal to 2^(13+dot11VHTMaxRxAMPDUFactor) -1 octets." ::= { dot11VHTStationConfigEntry 2 } dot11VHTControlFieldOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of receiving the VHT variant HT Control field." ::= { dot11VHTStationConfigEntry 3 } dot11VHTTXOPPowerSaveOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of VHT TXOP power save operation." ::= { dot11VHTStationConfigEntry 4 } dot11VHTRxVHTMCSMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Each octet represents the highest VHT-MCS supported (for Rx) on the number of streams represented by the octet position (first octet represents 1 stream, second octet represents 2 streams, etc.) A value 0 indicates that VHT-MCSs 0-7 are supported. A value 1 indicates that VHT-MCSs 0-8 are supported. A value 2 indicates that VHT-MCSs 0-9 are supported. A value 3 indicates no support for that number of spatial streams." ::= { dot11VHTStationConfigEntry 5 } dot11VHTRxHighestDataRateSupported OBJECT-TYPE SYNTAX Unsigned32 UNITS "Mb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Represents the highest data rate that the STA is capable of receiving." ::= { dot11VHTStationConfigEntry 6 } dot11VHTTxVHTMCSMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Each octet represents the highest VHT-MCS supported (for Tx) on the number of streams represented by the octet position (first octet represents 1 stream, second octet represents 2 streams, etc.). A value 0 indicates that VHT-MCSs 0-7 are supported. A value 1 indicates that VHT-MCSs 0-8 are supported. A value 2 indicates that VHT-MCSs 0-9 are supported. A value 3 indicates no support for that number of spatial streams." ::= { dot11VHTStationConfigEntry 7 } dot11VHTTxHighestDataRateSupported OBJECT-TYPE SYNTAX Unsigned32 UNITS "Mb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Represents the highest data rate that the STA is capable of transmitting." ::= { dot11VHTStationConfigEntry 8 } dot11VHTOBSSScanCount OBJECT-TYPE SYNTAX Unsigned32 (3..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum number of scan operations performed on a channel to detect another OBSS." DEFVAL { 3 } ::= { dot11VHTStationConfigEntry 9 } -- ******************************************************************** -- * End of dot11VHTStationConfigTable TABLE -- ******************************************************************** -- ********************************************************************* -- * dot11TVHTStationConfig TABLE -- ********************************************************************** dot11TVHTStationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11TVHTStationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Station Configuration attributes. In tabular form to allow for multiple instances on an agent." ::= { dot11smt 32 } dot11TVHTStationConfigEntry OBJECT-TYPE SYNTAX Dot11TVHTStationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the dot11HTStationConfig Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11TVHTStationConfigTable 1 } Dot11TVHTStationConfigEntry ::= SEQUENCE { dot11TVHTMaxMPDULength INTEGER, dot11TVHTMaxRxAMPDUFactor Unsigned32, dot11TVHTControlFieldOptionImplemented TruthValue, dot11TVHTTXOPPowerSaveOptionImplemented TruthValue, dot11TVHTRxVHTMCSMap OCTET STRING, dot11TVHTRxHighestDataRateSupported Unsigned32, dot11TVHTTxVHTMCSMap OCTET STRING, dot11TVHTTxHighestDataRateSupported Unsigned32, dot11TVHTOBSSScanCount Unsigned32 } dot11TVHTMaxMPDULength OBJECT-TYPE SYNTAX INTEGER { short(3895), medium(7991), long(11454) } UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum supported size of an MPDU received in a TVHT PPDU." ::= { dot11TVHTStationConfigEntry 1 } dot11TVHTMaxRxAMPDUFactor OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum length of A-MPDU that the STA can receive. The Maximum Rx A-MPDU defined by this field is equal to 2^(13+dot11TVHTMaxRxAMPDUFactor)-1 octets." ::= { dot11TVHTStationConfigEntry 2 } dot11TVHTControlFieldOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of receiving the VHT variant HT Control field." ::= { dot11TVHTStationConfigEntry 3 } dot11TVHTTXOPPowerSaveOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of VHT TXOP power save operation." ::= { dot11TVHTStationConfigEntry 4 } dot11TVHTRxVHTMCSMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Each octet represents the highest VHT-MCS supported (for Rx) on the number of streams represented by the octet position (first octet represents 1stream, second octet represents 2 streams, etc.). A value 0 indicates that VHT-MCSs 0-7 are supported. A value 1 indicates that VHT-MCSs 0-8 are supported. A value 2 indicates that VHT-MCSs 0-9 are supported. A value 3 indicates no support for that number of spatial streams." ::= { dot11TVHTStationConfigEntry 5 } dot11TVHTRxHighestDataRateSupported OBJECT-TYPE SYNTAX Unsigned32 UNITS "Mb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Represents the highest data rate that the STA is capable of receiving." ::= { dot11TVHTStationConfigEntry 6 } dot11TVHTTxVHTMCSMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Each octet represents the highest VHT-MCS supported (for Tx) on the number of streams represented by the octet position (first octet represents 1 stream, second octet represents 2 streams, etc.). A value 0 indicates that VHT-MCSs 0-7 are supported. A value 1 indicates that VHT-MCSs 0-8 are supported. A value 2 indicates that VHT-MCSs 0-9 are supported. A value 3 indicates no support for that number of spatial streams." ::= { dot11TVHTStationConfigEntry 7 } dot11TVHTTxHighestDataRateSupported OBJECT-TYPE SYNTAX Unsigned32 UNITS "Mb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Represents the highest data rate that the STA is capable of transmitting." ::= { dot11TVHTStationConfigEntry 8 } dot11TVHTOBSSScanCount OBJECT-TYPE SYNTAX Unsigned32 (3..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum number of scan operations performed on a channel to detect another OBSS." DEFVAL { 3 } ::= { dot11TVHTStationConfigEntry 9 } -- ******************************************************************** -- * End of dot11TVHTStationConfigTable TABLE -- ******************************************************************** -- ********************************************************************* -- * dot11FILSConfigTable TABLE -- ********************************************************************** dot11FILSConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11FILSConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table containing fast initial link setup configuration objects." ::= { dot11smt 35 } dot11FILSConfigEntry OBJECT-TYPE SYNTAX Dot11FILSConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11FILSConfigTable." INDEX { ifIndex } ::= { dot11FILSConfigTable 1 } Dot11FILSConfigEntry ::= SEQUENCE { dot11FILSFDFrameBeaconMinimumInterval Unsigned32, dot11FILSBeaconResponseWindow Unsigned32, dot11FILSFDFrameBeaconMaximumInterval Unsigned32, dot11FILSOmitReplicateProbeResponses TruthValue, dot11DILSImplemented TruthValue, dot11FILSProbeDelay Unsigned32, dot11HLPWaitTime Unsigned32, dot11CacheIdentifier OCTET STRING } dot11FILSFDFrameBeaconMinimumInterval OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. The STA is allowed to transmit a FILS Discovery frame if a duration defined by this value has elapsed since the previous Beacon or FILS Discovery frame transmission and the next TBTT is later than a duration defined by this value." DEFVAL { 20 } ::= { dot11FILSConfigEntry 1 } dot11FILSFDFrameBeaconMaximumInterval OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. If this value is not equal to 0, the STA queues for transmission a FILS Discovery frame or a Beacon frame if a duration defined by this value has elapsed since the previous Beacon or FILS Discovery frame transmission unless the next TBTT is within a duration defined by the value of dot11FILSFDFrameBeaconMinimumInterval." DEFVAL { 0 } ::= { dot11FILSConfigEntry 2 } dot11FILSBeaconResponseWindow OBJECT-TYPE SYNTAX Unsigned32 (0..1000000) UNITS "0.1 milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. If the duration from the reception of the Probe Request frame to the TBTT is less than the value, the STA does not transmit a Probe Response frame as response to the Probe Request frame." DEFVAL { 50 } ::= { dot11FILSConfigEntry 3 } dot11FILSOmitReplicateProbeResponses OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a policy variable. It is written by an external management entity. Changes take effect for the next Probe Response frame. This attribute, when true, indicates that the station may respond to one or more received Probe Request frames with a single Probe Response frame addressed to the broadcast address or alternatively, by not transmitting a Probe Response frame and instead letting the next Beacon frame be the response to the Probe Request frame(s)." DEFVAL { false } ::= { dot11FILSConfigEntry 4 } dot11DILSImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of supporting DILS category. The capability is disabled, otherwise." ::= { dot11FILSConfigEntry 5 } dot11FILSProbeDelay OBJECT-TYPE SYNTAX Unsigned32 (0..100000) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. If a FILS STA receives a suitable Probe Request, Probe Response, Beacon, FILS Discovery or Measurement Pilot frame within this duration of the start of active scanning on a given channel, it does not transmit a Probe Request frame." DEFVAL { 5000 } ::= { dot11FILSConfigEntry 6 } dot11HLPWaitTime OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This value specifies a time that the FILS AP waits for incoming HLP packets after receiving a (Re)Association Request frame." DEFVAL { 30 } ::= { dot11FILSConfigEntry 7 } dot11CacheIdentifier OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This value specifies the Cache Identifier that the FILS AP advertises in FILS Indication elements." ::= { dot11FILSConfigEntry 8 } -- ******************************************************************** -- * End of dot11FILSConfigTable TABLE -- ******************************************************************** -- ******************************************************************** -- * dot11STALCI TABLE -- ******************************************************************** dot11STALCITable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11STALCIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table represents the geolocation of the STA as specified in 11.42.1." ::= { dot11smt 33 } dot11STALCIEntry OBJECT-TYPE SYNTAX Dot11STALCIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "STA's location information in geospatial coordinates" INDEX {dot11STALCIIndex } ::= { dot11STALCITable 1 } Dot11STALCIEntry ::= SEQUENCE { dot11STALCIIndex Unsigned32, dot11STALCILatitudeUncertainty Unsigned32, dot11STALCILatitudeInteger Integer32, dot11STALCILatitudeFraction Integer32, dot11STALCILongitudeUncertainty Unsigned32, dot11STALCILongitudeInteger Integer32, dot11STALCILongitudeFraction Integer32, dot11STALCIAltitudeType INTEGER, dot11STALCIAltitudeUncertainty Unsigned32, dot11STALCIAltitude Integer32, dot11STALCIDatum INTEGER } dot11STALCIIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for STA LCI elements in dot11STALCITable, greater than 0." ::= { dot11STALCIEntry 1 } dot11STALCILatitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Latitude uncertainty is 6 bits indicating the amount of uncertainty in latitude value. A value of 0 is reserved to indicate that the uncertainty is unknown; values greater than 34 are reserved. This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 2 } dot11STALCILatitudeInteger OBJECT-TYPE SYNTAX Integer32 (-359..359) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Latitude is a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of Latitude. This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 3 } dot11STALCILatitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Latitude is a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of Latitude. This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 4 } dot11STALCILongitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude uncertainty is 6 bits indicating the amount of uncertainty in longitude value. A value of 0 is reserved to indicate that the uncertainty is unknown; values greater than 34 are reserved. This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 5 } dot11STALCILongitudeInteger OBJECT-TYPE SYNTAX Integer32 (-359..359) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude is a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of Longitude. This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 6 } dot11STALCILongitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude is a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of Longitude. This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 7 } dot11STALCIAltitudeType OBJECT-TYPE SYNTAX INTEGER { meters(1), floors(2), hagm (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Altitude Type is four bits encoding the type of altitude. Codes defined are: meters in 2s complement fixed-point 22-bit integer part with 8-bit fraction floors: in 2s complement fixed-point 22-bit integer part with 8-bit fraction hagm: Height Above Ground in meters, in 2s complement fixed-point 22-bit integer part with 8-bit fraction This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 8 } dot11STALCIAltitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Altitude uncertainty is 6 bits indicating the amount of uncertainty in the altitude value. A value of 0 is reserved to indicate that altitude uncertainty is not known; values above 30 are also reserved. Altitude uncertainty applies only to Altitude Type 1. This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 9 } dot11STALCIAltitude OBJECT-TYPE SYNTAX Integer32 (-536870912..536870911) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Altitude is a 30-bit value defined by the Altitude type field. The field is encoded as a 2s complement fixed-point 22-bit integer part with 8-bit fraction. This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 10 } -- Reserved: 11. Was dot11STALCIAltitudeFraction. dot11STALCIDatum OBJECT-TYPE SYNTAX INTEGER { wgs84 (1), nad83navd88 (2), nad93mllwvd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Datum is an 8-bit value encoding the horizontal and vertical references used for the coordinates given in this LCI. IETF RFC 6225 defines the values of Datum. Type 1 is WGS-84, the coordinate system used by GPS. Type 2 is NAD83 with NAVD88 vertical reference. Type 3 is NAD83 with Mean Lower Low Water vertical datum. All other types are reserved. This field is derived from IETF RFC 6225." ::= { dot11STALCIEntry 12 } -- ********************************************************************** -- * End of dot11STALCI TABLE -- ********************************************************************** -- ********************************************************************* -- * dot11S1GStationConfig TABLE -- ********************************************************************** dot11S1GStationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11S1GStationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Station Configuration attributes. In tabular form to allow for multiple instances on an agent." ::= { dot11smt 34 } dot11S1GStationConfigEntry OBJECT-TYPE SYNTAX Dot11S1GStationConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the dot11HTStationConfig Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11S1GStationConfigTable 1 } Dot11S1GStationConfigEntry ::= SEQUENCE { dot11S1GMaxMPDULength INTEGER, dot11S1GMaxRxAMPDUFactor Unsigned32, dot11S1GControlFieldOptionImplemented TruthValue, dot11S1GRxS1GMCSMap OCTET STRING, dot11S1GTxS1GMCSMap OCTET STRING, dot11S1GOBSSScanCount Unsigned32, dot11ShortBeaconInterval TruthValue, dot11ShortBeaconPeriod Unsigned32, dot11ShortBeaconDTIMPeriod Unsigned32, dot11PV1MACHeaderOptionImplemented TruthValue, dot11PV1ProbeResponseOptionImplemented TruthValue, dot11HeaderCompressionResponseTimeout Unsigned32, dot11TSFTimerAccuracyImplemented TruthValue, dot11NonTIMModeActivated TruthValue, dot11PageSlicingImplemented TruthValue, dot11PageSlicingActivated TruthValue, dot11DynamicAIDActivated TruthValue, dot11GroupAIDActivated TruthValue, dot11AMSDUImplemented TruthValue, dot11AMPDUImplemented TruthValue, dot11MCSNegotiation TruthValue, dot11AsymmetricBlockAckActivated TruthValue, dot11FragmentBAOptionImplemented TruthValue, dot11RAWOperationImplemented TruthValue, dot11RAWOperationActivated TruthValue, dot11S1GUplinkSyncOptionImplemented TruthValue, dot11TWTOptionActivated TruthValue, dot11BATImplemented TruthValue, dot11PollTACKResponseImplemented TruthValue, dot11NDPProbingActivated TruthValue, dot11NDPPSPollSupport TruthValue, dot11RelayAPImplemented TruthValue, dot11RelayAPOperationActivated TruthValue, dot11RelaySTAImplemented TruthValue, dot11RelaySTAOperationActivated TruthValue, dot11RelayDiscoveryOptionImplemented TruthValue, dot11TXOPSharingImplicitACKImplemented TruthValue, dot11S1GELOperationActivated TruthValue, dot11S1GCentralizedAuthenticationControlActivated TruthValue, dot11S1GDistributedAuthenticationControlActivated TruthValue, dot11SubchannelSelectiveTransmissionActivated TruthValue, dot11S1GSectorImplemented TruthValue, dot11S1GSectorizationActivated TruthValue, dot11S1GSectorTrainingOperationImplemented TruthValue, dot11NDPBeamformingReportPollImplemented TruthValue, dot11UnsolicitedDynamicAIDActivated TruthValue, dot11TIMADEImplemented TruthValue, dot11SelectiveSubchannelTransmissionPermitted TruthValue, dot11MaxAwayDuration Unsigned32, dot11APPMActivated TruthValue, dot11BDTImplemented TruthValue, dot11S1GCACDeferral TruthValue, dot11S1GCACThreshold Unsigned32, dot11S1GDACTac Unsigned32, dot11S1GDACTImin Unsigned32, dot11S1GDACTImax Unsigned32, dot11ProtectedTWTOperationsImplemented TruthValue } dot11S1GMaxMPDULength OBJECT-TYPE SYNTAX INTEGER { short(3895), long (7991) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the supported maximum MPDU size." ::= { dot11S1GStationConfigEntry 1 } dot11S1GMaxRxAMPDUFactor OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum length of A-MPDU that the STA can receive. The maximum receive A-MPDU defined by this field is equal to 2^(13+dot11S1GMaxRxAMPDUFactor) -1 octets." ::= { dot11S1GStationConfigEntry 2 } dot11S1GControlFieldOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of receiving the VHT variant HT Control field. See 10.8." ::= { dot11S1GStationConfigEntry 3 } dot11S1GRxS1GMCSMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Each octet represents the highest S1G-MCS supported (for Rx) on the number of streams represented by the octet position (e.g., first octet represents 1 stream, second octet represents 2 streams). A value 0 indicates that S1G-MCSs 0-2 are supported. A value 1 indicates that S1G-MCSs 0-7 are supported. A value 2 indicates that S1G-MCSs 0-9 are supported. A value 3 indicates no support for that number of spatial streams. For 1 MHz, MCS 10 is always supported." ::= { dot11S1GStationConfigEntry 4 } dot11S1GTxS1GMCSMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Each octet represents the highest S1G-MCS supported (for Tx) on the number of streams represented by the octet position (e.g., first octet represents 1 stream, second octet represents 2 streams). A value 0 indicates that S1G-MCSs 0-2 are supported. A value 1 indicates that S1G-MCSs 0-7 are supported. A value 2 indicates that S1G-MCSs 0-9 are supported. A value 3 indicates no support for that number of spatial streams. For 1 MHz, MCS 10 is always supported." ::= { dot11S1GStationConfigEntry 5 } dot11S1GOBSSScanCount OBJECT-TYPE SYNTAX Unsigned32 (3..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum number of scan operations performed on a channel to detect another OBSS." DEFVAL { 3 } ::= { dot11S1GStationConfigEntry 6 } dot11ShortBeaconInterval OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. This is a primary/secondary variable. Its value on an AP or IBSS initiator is written by external management entity and changes take effect for the next MLME-START.request primitive. Its value on non-AP STA is written by the MLME, adopted from the information received in a Beacon, Probe Response or PV1 Probe Response, when joining an S1G BSS or S1G IBSS. This attribute, when true, indicates that that the AP schedules for transmission a Beacon frame in a TSBTT that is not a TBTT." ::= { dot11S1GStationConfigEntry 7 } dot11ShortBeaconPeriod OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies the number of TUs that a STA uses for scheduling S1G Beacon transmissions in a TSBTT that is not a TBTT. This value is transmitted in the S1G Beacon, Probe Response, and PV1 Probe Response frames." ::= { dot11S1GStationConfigEntry 8 } dot11ShortBeaconDTIMPeriod OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect for the next MLME-START.request primitive. This attribute specifies the number of short beacon intervals that elapse between transmission of S1G Beacon frames containing a TIM element whose DTIM Count field is 0. This value is transmitted in S1G Beacon frames." ::= { dot11S1GStationConfigEntry 9 } dot11PV1MACHeaderOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of generating frames with PV1 MAC Header. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 10 } dot11PV1ProbeResponseOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting PV1 Probe Response frames. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 11 } dot11HeaderCompressionResponseTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. This attribute indicates the amount of time, in units of milliseconds, the STA waits before timing out a Header Compression frame request." DEFVAL { 5 } ::= { dot11S1GStationConfigEntry 12 } dot11TSFTimerAccuracyImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting the TSF Timer Accuracy option. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 13 } dot11NonTIMModeActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the non-TIM mode is enabled. The non-TIM mode is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 14 } dot11PageSlicingImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting the page slicing option. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 15 } dot11PageSlicingActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the page slicing option is enabled. The page slicing option is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 16 } dot11DynamicAIDActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the dynamic AID is enabled. The dynamic AID is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 17 } dot11GroupAIDActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the group AID is enabled. The group AID is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 18 } dot11AMSDUImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving A-MSDU carried in S1G PPDUs." ::= { dot11S1GStationConfigEntry 19 } dot11AMPDUImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving an A-MPDU frame that is not a S-MPDU carried in S1G PPDUs." ::= { dot11S1GStationConfigEntry 20 } dot11MCSNegotiation OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the MCS negotiation is enabled. The MCS negotiation is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 21 } dot11AsymmetricBlockAckActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that asymmetric BA is enabled. Asymmetric BA is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 22 } dot11FragmentBAOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting fragment BA. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 23 } dot11RAWOperationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting the RAW operation. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 24 } dot11RAWOperationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the RAW operation is enabled. The RAW operation is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 25 } dot11S1GUplinkSyncOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting the uplink synch option. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 26 } dot11TWTOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the STA capability for the target wake time function is enabled. A value of false indicates that the STA has no capability for the target wake time function, or that the capability is present, but disabled." DEFVAL { false } ::= { dot11S1GStationConfigEntry 27} dot11BATImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting BAT operation. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 28 } dot11PollTACKResponseImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of generating a TACK frame as a response to a PS-Poll with the Poll Type subfield equal to 1. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 29 } dot11NDPProbingActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the NDP Probing is enabled. The NDP Probing is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 30 } dot11NDPPSPollSupport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the NDP PS-Poll operation is enabled. The NDP PS-Poll operation is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 31 } dot11RelayAPImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA permits association by a relay STA. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 32 } dot11RelayAPOperationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the relay AP operation is enabled. The relay AP operation is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 33 } dot11RelaySTAImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is a relay STA inside a relay. This should not be modified during the life of the STA." ::= { dot11S1GStationConfigEntry 34 } dot11RelaySTAOperationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the relay STA operation is enabled. This attribute can be modified during the life of the STA in the BSS by sending Relay Activation element. The relay STA operation is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 35 } dot11RelayDiscoveryOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting Relay Discovery option. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 36 } dot11TXOPSharingImplicitACKImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities This attribute, when true, indicates that the TXOP sharing implicit Ack operation is enabled. The TXOP sharing implicit Ack operation is disabled otherwise." ::= { dot11S1GStationConfigEntry 37 } dot11S1GELOperationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the EL operation is enabled. The EL operation is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 38 } dot11S1GCentralizedAuthenticationControlActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the Centralized Authentication Control operation is enabled. The Centralized Authentication Control operation is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 39 } dot11S1GDistributedAuthenticationControlActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the Distributed Authentication Control operation is enabled. The Distributed Authentication Control operation is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 40 } dot11SubchannelSelectiveTransmissionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the Subchannel Selective Transmission is enabled. The Subchannel Selective Transmission is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 41 } dot11S1GSectorImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting S1G Sector option. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 42 } dot11S1GSectorizationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the S1G Sector operation is enabled. The S1G Sector operation is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 43 } dot11S1GSectorTrainingOperationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting the S1G Sector Training option. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 44 } dot11NDPBeamformingReportPollImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the NDP Beamforming Report Poll operation is enabled. The NDP Beamforming Report Poll operation is disabled otherwise." ::= { dot11S1GStationConfigEntry 45 } dot11UnsolicitedDynamicAIDActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the unsolicited dynamic AID is enabled. The unsolicited dynamic AID is disabled otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 46 } dot11TIMADEImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of supporting the ADE mode of TIM bitmap encoding. The capability is disabled, otherwise." ::= { dot11S1GStationConfigEntry 47 } dot11SelectiveSubchannelTransmissionPermitted OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. When this object is true, this indicates that Selective Subchannel Transmission is permitted by this entity." DEFVAL { false } ::= { dot11S1GStationConfigEntry 48} dot11MaxAwayDuration OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates from the STA, the maximum allowed duration for the AP to be not reachable, from the AP, the maximum duration that AP guarantees to be reachable by the STA." DEFVAL { 65535 } ::= { dot11S1GStationConfigEntry 49} dot11APPMActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates if the AP may go to doze state." DEFVAL { false } ::= { dot11S1GStationConfigEntry 50} dot11BDTImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the station implementation is capable of supporting the bidirectional TXOP Operation. The capability is disabled, otherwise." DEFVAL { false } ::= { dot11S1GStationConfigEntry 51} dot11S1GCACDeferral OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving an Authentication Control element with Control subfield equal to 0. Changes take effect as soon as practical in the implementation. This attribute specifies whether the deferred channel access is used by the Centralized Authentication Control operation." DEFVAL { false } ::= { dot11S1GStationConfigEntry 52 } dot11S1GCACThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving an Authentication Control element with Control subfield equal to 0. Changes take effect as soon as practical in the implementation. This attribute specifies the threshold value that is used by the Centralized Authentication Control operation." DEFVAL { 1024 } ::= { dot11S1GStationConfigEntry 53 } dot11S1GDACTac OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving an Authentication Control element with Control subfield equal to 1. Changes take effect as soon as practical in the implementation. This attribute specifies the Authentication Slot Duration that is used by the Distributed Authentication Control operation." DEFVAL { 10 } ::= { dot11S1GStationConfigEntry 54 } dot11S1GDACTImin OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving an Authentication Control element with Control subfield equal to 1. Changes take effect as soon as practical in the implementation. This attribute specifies the minimum transmission interval that is used by the Distributed Authentication Control operation." DEFVAL { 8 } ::= { dot11S1GStationConfigEntry 55 } dot11S1GDACTImax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC upon receiving an Authentication Control element with Control subfield equal to 1. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum transmission interval that is used by the Distributed Authentication Control operation." DEFVAL { 256 } ::= { dot11S1GStationConfigEntry 56 } dot11ProtectedTWTOperationsImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates whether the entity is capable of protected TWT operations." ::= { dot11S1GStationConfigEntry 57 } -- ******************************************************************** -- * End of dot11S1GStationConfigTable TABLE -- ******************************************************************** --********************************************************************* -- * dot11CDMGSTAConfigTable TABLE --********************************************************************* dot11CDMGSTAConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11CDMGSTAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table management object. The dot11CDMGSTAConfig Table" ::= { dot11smt 39 } dot11CDMGSTAConfigEntry OBJECT-TYPE SYNTAX Dot11CDMGSTAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry in the dot11CDMGSTAConfig Table. ifIndex - Each IEEE Std 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11CDMGSTAConfigTable 1 } Dot11CDMGSTAConfigEntry ::= SEQUENCE { dot11CDMGOptionImplemented TruthValue, dot11DynamicChannelTransferActivated TruthValue, dot11OpportunisticTransmissionsImplemented TruthValue } dot11CDMGOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. CDMG Capable Object This attribute, when true, indicates the STA is CDMG capable. This attribute, when false, indicates the STA is not CDMG capable." ::= { dot11CDMGSTAConfigEntry 1 } dot11DynamicChannelTransferImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from the standard. This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates the CDMG STA is dynamic channel selection capable. This attribute, when false, indicates the STA is not dynamic channel selection capable." ::= { dot11CDMGSTAConfigEntry 2 } dot11DynamicChannelTransferActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the dynamic channel selection is activated." DEFVAL { false } ::= { dot11CDMGSTAConfigEntry 3 } dot11OpportunisticTransmissionsActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from the standard. This is a capability variable. Its value is determined by device capabilities. If dot11OpportunisticTransmissionsActivated is true, the STA is capable of supporting opportunistic transmissions." ::= { dot11CDMGSTAConfigEntry 4 } dot11CDMGSpatialsharingActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from the standard. This is a capability variable. Its value is determined by device capabilities. If dot11CDMGSpatialsharingActivated is true, the STA is capable of supporting CDMG spatial sharing." ::= { dot11CDMGSTAConfigEntry 5 } dot11CDMGClusteringActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from the standard. This is a capability variable. Its value is determined by device capabilities. If dot11CDMGClusteringActivated is true, the STA is capable of supporting CDMG AP or PCP clustering." ::= { dot11CDMGSTAConfigEntry 6 } dot11OpportunisticTransmissionsImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. If dot11OpportunisticTransmissionsImplemented is true, the STA is capable of supporting opportunistic transmissions." DEFVAL { false } ::= { dot11CDMGSTAConfigEntry 7 } --****************************************************************** -- * End of dot11CDMGSTAConfigTable TABLE --****************************************************************** --****************************************************************** -- * dot11CMMGSTAConfigTable TABLE --****************************************************************** dot11CMMGSTAConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11CMMGSTAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table management object. The dot11CMMGSTAConfig Table" ::= { dot11smt 40 } dot11CMMGSTAConfigEntry OBJECT-TYPE SYNTAX Dot11CMMGSTAConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry in the dot11CMMGSTAConfig Table. ifIndex - Each IEEE Std 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11CMMGSTAConfigTable 1 } Dot11CMMGSTAConfigEntry ::= SEQUENCE { dot11CMMGMaxMPDULength INTEGER, dot11CMMGMaxRxAMPDUFactor Unsigned32, dot11CMMGControlFieldOptionImplemented TruthValue, dot11CMMGTXOPPowerSaveOptionImplemented TruthValue, dot11CMMGRxCMMGMCSMap OCTET STRING, dot11CMMGRxHighestDataRateSupported Unsigned32, dot11CMMGTxCMMGMCSMap OCTET STRING, dot11CMMGTxHighestDataRateSupported Unsigned32, dot11CMMGOptionImplemented TruthValue, dot11CMMGClusteringActivated TruthValue, dot11CMMGOBSSScanCount Unsigned32 } dot11CMMGMaxMPDULength OBJECT-TYPE SYNTAX INTEGER { short(3895), medium(7991), long(11454) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the supported maximum MPDU size." ::= { dot11CMMGSTAConfigEntry 1 } dot11CMMGMaxRxAMPDUFactor OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum length of A-MPDU that the STA can receive. The Maximum Rx A-MPDU defined by this field is equal to 2^(13+dot11CMMGMaxRxAMPDUFactor)-1 octets." ::= { dot11CMMGSTAConfigEntry 2 } dot11CMMGControlFieldOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of receiving the CMMG variant HT Control field." ::= { dot11CMMGSTAConfigEntry 3 } dot11CMMGTXOPPowerSaveOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station implementation is capable of TXOP Power Save operation." ::= { dot11CMMGSTAConfigEntry 4 } dot11CMMGRxCMMGMCSMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Each octet represents the highest CMMG-MCS supported (for Rx) on the number of streams represented by the octet position (first octet represents 1 stream, second octet represents 2 streams, etc.) A value 0 indicates that CMMG-MCSs SC 1-5 (OFDM 9-13) are supported. A value 1 indicates that CMMG-MCSs SC 1-6 (OFDM 9-14) are supported. A value 2 indicates that CMMG-MCSs SC 1-7 (OFDM 9-15) are supported. A value 2 indicates that CMMG-MCSs SC 1-8 (OFDM 9-16) are supported. A value 4-7 indicates no support for that number of spatial streams." ::= { dot11CMMGSTAConfigEntry 5 } dot11CMMGRxHighestDataRateSupported OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Represents the highest data rate in Mb/s that the STA is capable of receiving." ::= { dot11CMMGSTAConfigEntry 6 } dot11CMMGTxCMMGMCSMap OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Each octet represents the highest CMMG-MCS supported (for Rx) on the number of streams represented by the octet position (first octet represents 1 stream, second octet represents 2 streams, etc.) A value 0 indicates that CMMG-MCSs SC 1-5 (OFDM 9-13) are supported. A value 1 indicates that CMMG-MCSs SC 1-6 (OFDM 9-14) are supported. A value 2 indicates that CMMG-MCSs SC 1-7 (OFDM 9-15) are supported. A value 2 indicates that CMMG-MCSs SC 1-8 (OFDM 9-16) are supported. A value 4-7 indicates no support for that number of spatial streams." ::= { dot11CMMGSTAConfigEntry 7 } dot11CMMGTxHighestDataRateSupported OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Represents the highest data rate in Mb/s that the STA is capable of receiving." ::= { dot11CMMGSTAConfigEntry 8 } dot11CMMGOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. CMMG Capable Object This attribute, when true, indicates the STA is CMMG capable. This attribute, when false, indicates the STA is not CMMG capable.." ::= { dot11CMMGSTAConfigEntry 9 } dot11CMMGClusteringActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. If dot11CMMGClusteringActivated is true, the STA is capable of supporting CMMG AP or PCP clustering." ::= { dot11CMMGSTAConfigEntry 10 } dot11CMMGOBSSScanCount OBJECT-TYPE SYNTAX Unsigned32 (3..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum number of scan operations performed on a channel to detect another OBSS." DEFVAL { 3 } ::= { dot11CMMGSTAConfigEntry 11 } --****************************************************************** -- * End of dot11CMMGSTAConfigTable TABLE --****************************************************************** -- *************************************************************** -- * dot11GLKLinkMetrics TABLE -- *************************************************************** dot11GLKLinkMetricsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11GLKLinkMetricsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of GLK Link metrics information. One entry per association or peering." ::= { dot11smt 41 } dot11GLKLinkMetricsEntry OBJECT-TYPE SYNTAX Dot11GLKLinkMetricsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11GLKLinkMetricsTable" INDEX { ifIndex } ::= { dot11GLKLinkMetricsTable 1 } Dot11GLKLinkMetricsEntry ::= SEQUENCE { dot11GLKLinkRawRate Unsigned32, dot11GLKLinkMinRate Unsigned32, dot11GLKLinkAvgRate Unsigned32, dot11GLKLinkGeoRate Unsigned32, dot11GLKLinkSTDRate Unsigned32, dot11GLKLinkRateReported Unsigned32 } dot11GLKLinkRawRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum achievable data rate given the enabled STA features in units of 100 kb/s. This is a status variable." ::= { dot11GLKLinkMetricsEntry 1 } dot11GLKLinkMinRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum data rate seen in the window of samples in units of 100 kb/s. This is a status variable." ::= { dot11GLKLinkMetricsEntry 2 } dot11GLKLinkAvgRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The arithmetic mean data rate seen across the window of samples in units of 100 kb/s. This is a status variable." ::= { dot11GLKLinkMetricsEntry 3 } dot11GLKLinkGeoRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The geometric mean of the data rates seen across the window of samples in units of 100 kb/s. This is a status variable." ::= { dot11GLKLinkMetricsEntry 4 } dot11GLKLinkSTDRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The standard deviation of the data rates seen across the window of samples in units of 100 kb/s. This is a status variable." ::= { dot11GLKLinkMetricsEntry 5 } dot11GLKLinkRateReported OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The reported link data rate in units of 100 kb/s. This is a status variable." ::= { dot11GLKLinkMetricsEntry 6 } -- *************************************************************** -- * End of dot11GLKLinkMetrics TABLE -- *************************************************************** -- *************************************************************** -- * dot11STALCIConfig Table -- *************************************************************** dot11STALCIConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11STALCIConfiguration MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object represents the sequence of STA’s geospatial coordinates." ::= { dot11smt 36 } dot11STALCIConfiguration OBJECT-TYPE SYNTAX Dot11STALCIConfiguration MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object represents the geospatial coordinates of the STA." INDEX { ifIndex } ::= { dot11STALCIConfigTable 1 } Dot11STALCIConfiguration ::= SEQUENCE { dot11STALCIConfigLatitudeUncertainty Unsigned32, dot11STALCIConfigLatitudeInteger Integer32, dot11STALCIConfigLatitudeFraction Integer32, dot11STALCIConfigLongitudeUncertainty Unsigned32, dot11STALCIConfigLongitudeInteger Integer32, dot11STALCIConfigLongitudeFraction Integer32, dot11STALCIConfigAltitudeType INTEGER, dot11STALCIConfigAltitudeUncertainty Unsigned32, dot11STALCIConfigAltitude Integer32, dot11STALCIConfigDatum INTEGER } dot11STALCIConfigLatitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Latitude uncertainty is 6 bits indicating the amount of uncertainty in latitude value. A value of 0 is reserved to indicate that the uncertainty is unknown; values greater than 34 are reserved. This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 1 } dot11STALCIConfigLatitudeInteger OBJECT-TYPE SYNTAX Integer32 (-359..359) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Latitude is a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of Latitude. This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 2 } dot11STALCIConfigLatitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Latitude is a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of Latitude. This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 3 } dot11STALCIConfigLongitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude uncertainty is 6 bits indicating the amount of uncertainty in longitude value. A value of 0 is reserved to indicate that the uncertainty is unknown; values greater than 34 are reserved. This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 4 } dot11STALCIConfigLongitudeInteger OBJECT-TYPE SYNTAX Integer32 (-359..359) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude is a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of Longitude. This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 5 } dot11STALCIConfigLongitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude is a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of Longitude. This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 6 } dot11STALCIConfigAltitudeType OBJECT-TYPE SYNTAX INTEGER { meters(1), floors(2), hagm (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Altitude Type is four bits encoding the type of altitude. Codes defined are: meters in 2s complement fixed-point 22-bit integer part with 8-bit fraction floors: in 2s complement fixed-point 22-bit integer part with 8-bit fraction hagm: Height Above Ground in meters, in 2s complement fixed-point 22-bit integer part with 8-bit fraction This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 7 } dot11STALCIConfigAltitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Altitude uncertainty is 6 bits indicating the amount of uncertainty in the altitude value. A value of 0 is reserved to indicate that altitude uncertainty is not known; values above 30 are also reserved. Altitude uncertainty applies only to Altitude Type 1. This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 8 } dot11STALCIConfigAltitude OBJECT-TYPE SYNTAX Integer32 (-536870912..536870911) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Altitude is a 30-bit value defined by the Altitude type field. The field is encoded as a 2s complement fixed-point 22-bit integer part with 8-bit fraction. This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 9 } dot11STALCIConfigDatum OBJECT-TYPE SYNTAX INTEGER { wgs84 (1), nad83navd88 (2), nad93mllwvd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Datum is an 8-bit value encoding the horizontal and vertical References used for the coordinates given in this LCI. IETF RFC 6225 defines the values of Datum. Type 1 is WGS-84, the coordinate system used by GPS. Type 2 is NAD83 with NAVD88 vertical reference. Type 3 is NAD83 with Mean Lower Low Water vertical datum. All other types are reserved. This field is derived from IETF RFC 6225." ::= { dot11STALCIConfiguration 10 } -- ******************************************************************** -- * End of dot11STALCIConfig -- ******************************************************************** -- ******************************************************************** -- * dot11STACivicLocationConfig Table -- ******************************************************************** dot11STACivicLocationConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11STACivicLocationConfiguration MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object represents the sequence of STA’s civic location." ::= { dot11smt 37 } dot11STACivicLocationConfiguration OBJECT-TYPE SYNTAX Dot11STACivicLocationConfiguration MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object represents the civic location of the STA." INDEX { ifIndex } ::= { dot11STACivicLocationConfigTable 1 } Dot11STACivicLocationConfiguration ::= SEQUENCE { dot11STACivicLocationType INTEGER, dot11STACivicLocation OCTET STRING } dot11STACivicLocationType OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Civic Location type is defined in 9.4.2.20.14." ::= { dot11STACivicLocationConfiguration 1 } dot11STACivicLocation OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Civic Location is defined in 9.4.2.21.13." ::= { dot11STACivicLocationConfiguration 2 } -- ******************************************************************** -- * End of dot11STACivicLocationConfig -- ******************************************************************** -- ********************************************************************** -- * MAC Attribute Templates -- ********************************************************************** -- ********************************************************************** -- * dot11Operation TABLE -- ********************************************************************** dot11OperationTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11OperationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group contains MAC attributes pertaining to the operation of the MAC. This has been implemented as a table in order to allow for multiple instantiations on an agent." ::= { dot11mac 1 } dot11OperationEntry OBJECT-TYPE SYNTAX Dot11OperationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11OperationEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11OperationTable 1 } Dot11OperationEntry ::= SEQUENCE { dot11MACAddress MacAddress, dot11RTSThreshold Unsigned32, dot11ShortRetryLimit Unsigned32, dot11LongRetryLimit Unsigned32, dot11FragmentationThreshold Unsigned32, dot11MaxTransmitMSDULifetime Unsigned32, dot11MaxReceiveLifetime Unsigned32, dot11ManufacturerID DisplayString, dot11ProductID DisplayString, dot11CAPLimit Unsigned32, dot11HCCWmin Unsigned32, dot11HCCWmax Unsigned32, dot11HCCAIFSN Unsigned32, dot11ADDBAResponseTimeout Unsigned32, dot11ADDTSResponseTimeout Unsigned32, dot11ChannelUtilizationBeaconIntervals Unsigned32, dot11ScheduleTimeout Unsigned32, dot11DLSResponseTimeout Unsigned32, dot11QAPMissingAckRetryLimit Unsigned32, dot11EDCAAveragingPeriod Unsigned32, dot11HTProtection INTEGER, dot11RIFSMode TruthValue, dot11PSMPControlledAccess TruthValue, dot11ServiceIntervalGranularity Unsigned32, dot11DualCTSProtection TruthValue, dot11LSIGTXOPFullProtectionActivated TruthValue, dot11NonGFEntitiesPresent TruthValue, dot11PCOActivated TruthValue, dot11PCOFortyMaxDuration Unsigned32, dot11PCOTwentyMaxDuration Unsigned32, dot11PCOFortyMinDuration Unsigned32, dot11PCOTwentyMinDuration Unsigned32, dot11FortyMHzIntolerant TruthValue, dot11BSSWidthTriggerScanInterval Unsigned32, dot11BSSWidthChannelTransitionDelayFactor Unsigned32, dot11OBSSScanPassiveDwell Unsigned32, dot11OBSSScanActiveDwell Unsigned32, dot11OBSSScanPassiveTotalPerChannel Unsigned32, dot11OBSSScanActiveTotalPerChannel Unsigned32, dot112040BSSCoexistenceManagementSupport TruthValue, dot11OBSSScanActivityThreshold Unsigned32 } dot11MACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Unique MAC Address assigned to the STA." ::= { dot11OperationEntry 1 } dot11RTSThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..4692480) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the number of octets in a PSDU, below which an RTS/CTS handshake is not performed, except as RTS/CTS is used as a cross modulation protection mechanism as defined in 10.27. An RTS/CTS handshake is performed at the beginning of any frame exchange sequence where the PSDU contains an MPDU with the Type subfield equal to Data or Management and an individual address in the Address 1 field, and the length of the PSDU is greater than this threshold. Setting this attribute to be larger than the maximum PSDU size has the effect of turning off the RTS/CTS handshake for frames of Data or Management type transmitted by this STA. Setting this attribute to 0 has the effect of turning on the RTS/CTS handshake for all frames of Data or Management type transmitted by this STA." DEFVAL { 4692480 } ::= { dot11OperationEntry 2 } dot11ShortRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum number of transmission attempts of a frame that are made before a failure condition is indicated." DEFVAL { 7 } ::= { dot11OperationEntry 3 } dot11LongRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum number of transmission attempts of a frame, in a PSDU of length that is greater than dot11RTSThreshold, that is made before a failure condition is indicated." DEFVAL { 4 } ::= { dot11OperationEntry 4 } dot11FragmentationThreshold OBJECT-TYPE SYNTAX Unsigned32 (256..65535) UNITS "octets" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum size of an individually addressed MPDU beyond which the corresponding MSDU or MMPDU is fragmented, except when an MSDU is transmitted under an HT-immediate block ack agreement, or when an MSDU is carried in an A-MSDU, or when an MSDU or MMPDU is carried in an A-MPDU that does not contain a S-MPDU. Fields added to the MPDU by security encapsulation are not counted against the limit specified by this attribute. An MSDU or MMPDU might be fragmented even if it is smaller." DEFVAL { 65535 } ::= { dot11OperationEntry 5 } dot11MaxTransmitMSDULifetime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the elapsed time, after the initial transmission of an MSDU/MMPDU (or the first fragment thereof), after which further attempts to transmit the MSDU/MMPDU are terminated." DEFVAL { 512 } ::= { dot11OperationEntry 6 } dot11MaxReceiveLifetime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The MaxReceiveLifetime is the elapsed time, after the initial reception of a fragmented MMPDU or MSDU, after which further attempts to reassemble the MMPDU or MSDU are terminated." DEFVAL { 512 } ::= { dot11OperationEntry 7 } dot11ManufacturerID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The ManufacturerID includes, at a minimum, the name of the manufacturer. It may include additional information at the manufacturer's discretion." ::= { dot11OperationEntry 8 } dot11ProductID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The ProductID includes, at a minimum, an identifier that is unique to the manufacturer. It may include additional information at the manufacturer's discretion." ::= { dot11OperationEntry 9 } dot11CAPLimit OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum number of TUs a Controlled access phase(CAP) can last." ::= { dot11OperationEntry 10 } dot11HCCWmin OBJECT-TYPE SYNTAX Unsigned32 -- (0..aCWmin) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the value of the minimum size of the window that is used by the HC for generating a random number for the backoff. The value of this attribute is such that it could always be expressed in the form of 2^X - 1, where X is an integer." DEFVAL { 0 } ::= { dot11OperationEntry 11 } dot11HCCWmax OBJECT-TYPE SYNTAX Unsigned32 -- (0..aCWmax) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the value of the maximum size of the window that is used by the HC for generating a random number for the backoff. The value of this attribute is such that it could always be expressed in the form of 2^X - 1, where X is an integer." DEFVAL { 0 } ::= { dot11OperationEntry 12 } dot11HCCAIFSN OBJECT-TYPE SYNTAX Unsigned32 (1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of slots, after a SIFS, that the HC senses the medium idle either before transmitting or executing a backoff." DEFVAL { 1 } ::= { dot11OperationEntry 13 } dot11ADDBAResponseTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..65535) UNITS "seconds" MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the timeout for an ADDBA Response frame that is a response to an ADDBA Request frame." DEFVAL { 1 } ::= { dot11OperationEntry 14 } dot11ADDTSResponseTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum number of seconds an ADDTS request is to be responded." DEFVAL { 1 } ::= { dot11OperationEntry 15 } dot11ChannelUtilizationBeaconIntervals OBJECT-TYPE SYNTAX Unsigned32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the number of beacon intervals over which the channel busy time should be averaged." DEFVAL { 50 } ::= { dot11OperationEntry 16 } dot11ScheduleTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..100) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the duration after which a STA could go into power save mode." DEFVAL { 10 } ::= { dot11OperationEntry 17 } dot11DLSResponseTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum number of seconds a direct link request is to be responded." DEFVAL { 10 } ::= { dot11OperationEntry 18 } dot11QAPMissingAckRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the number of times the AP may retry a frame for which it does not receive an acknowledgment for a STA in power save mode after receiving a PS-Poll frame and sending an individually addressed response or after receiving a U-APSD trigger frame and sending an individually addressed response with the EOSP subfield equal to 1." ::= { dot11OperationEntry 19 } dot11EDCAAveragingPeriod OBJECT-TYPE SYNTAX Unsigned32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the number of seconds over which the admitted_time and used_time are computed." DEFVAL { 5 } ::= { dot11OperationEntry 20 } dot11HTProtection OBJECT-TYPE SYNTAX INTEGER { htNoProtection (0), htNonmemberProtection(1), ht20MHzProtection(2), htNonHTmixed(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the level of protection that needs to be provided to the transmissions in an IEEE 802.11 network with HT STAs." DEFVAL { htNoProtection } ::= { dot11OperationEntry 21 } dot11RIFSMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that use of RIFS is allowed in the BSS." DEFVAL { false } ::= { dot11OperationEntry 22 } dot11PSMPControlledAccess OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true indicates that the AP accepts associations only from STAs for which dot11PSMPOptionImplemented is true." DEFVAL { false } ::= { dot11OperationEntry 23 } dot11ServiceIntervalGranularity OBJECT-TYPE SYNTAX Unsigned32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the SI granularity to be used for scheduled PSMP. The value of the granularity is given by (dot11ServiceIntervalGranularity+1)*5 ms." DEFVAL { 0 } ::= { dot11OperationEntry 24 } dot11DualCTSProtection OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true indicates that the AP uses dual CTS protection to protect the non-STBC frame and STBC frame transmissions." DEFVAL { false } ::= { dot11OperationEntry 25 } dot11LSIGTXOPFullProtectionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the L-SIG TXOP protection may be used by STAs that have the attribute dot11LsigTxopProtectionOptionImplemented equal to true." DEFVAL { false } ::= { dot11OperationEntry 26 } dot11NonGFEntitiesPresent OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when it determines that the presence of greenfield stations in the BSS has changed. This attribute, when true, indicates that STA that are not HT-greenfield Capable are present in the BSS." DEFVAL { false } ::= { dot11OperationEntry 27 } dot11PCOActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the PCO is activated." DEFVAL { false } ::= { dot11OperationEntry 28 } dot11PCOFortyMaxDuration OBJECT-TYPE SYNTAX Unsigned32 (1..200) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The attribute indicates the maximum duration of 40 MHz phase in TU under PCO operation. The value of this attribute shall be equal to or larger than dot11PCOFortyMinDuration." DEFVAL { 30 } ::= { dot11OperationEntry 29 } dot11PCOTwentyMaxDuration OBJECT-TYPE SYNTAX Unsigned32 (1..200) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The attribute indicates the maximum duration of 20 MHz phase in TU under PCO operation. The value of this attribute shall be equal to or larger than dot11PCOTwentyMinDuration." DEFVAL { 30 } ::= { dot11OperationEntry 30 } dot11PCOFortyMinDuration OBJECT-TYPE SYNTAX Unsigned32 (1..200) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The attribute indicates the minimum duration of 40 MHz phase in TU under PCO operation." DEFVAL { 20 } ::= { dot11OperationEntry 31 } dot11PCOTwentyMinDuration OBJECT-TYPE SYNTAX Unsigned32 (1..200) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The attribute indicates the minimum duration of 20 MHz phase in TU under PCO operation." DEFVAL { 20 } ::= { dot11OperationEntry 32 } dot11FortyMHzIntolerant OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the STA requests that 40 MHz mask PPDUs are not transmitted within range of the STA." DEFVAL { false } ::= { dot11OperationEntry 33 } dot11BSSWidthTriggerScanInterval OBJECT-TYPE SYNTAX Unsigned32 (10..900) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum interval between scan operations to be performed to detect BSS channel width trigger events." DEFVAL { 300 } ::= { dot11OperationEntry 34 } dot11BSSWidthChannelTransitionDelayFactor OBJECT-TYPE SYNTAX Unsigned32 (5..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum ratio between the delay time in performing a switch from 20 MHz BSS operation to 20/40 MHz BSS operation and the maximum interval between OBSS scan operations." DEFVAL { 5 } ::= { dot11OperationEntry 35 } dot11OBSSScanPassiveDwell OBJECT-TYPE SYNTAX Unsigned32 (5..1000) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum amount of time that the STA continuously scans each channel when performing a passive OBSS scan operation." DEFVAL { 20 } ::= { dot11OperationEntry 36 } dot11OBSSScanActiveDwell OBJECT-TYPE SYNTAX Unsigned32 (10..1000) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum amount of time that the STA continuously scans each channel when performing an active OBSS scan operation." DEFVAL { 10 } ::= { dot11OperationEntry 37 } dot11OBSSScanPassiveTotalPerChannel OBJECT-TYPE SYNTAX Unsigned32 (200..10000) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum total amount of time that the STA scans each channel when performing a passive OBSS scan operation." DEFVAL { 200 } ::= { dot11OperationEntry 38 } dot11OBSSScanActiveTotalPerChannel OBJECT-TYPE SYNTAX Unsigned32 (20..10000) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the minimum total amount of time that the STA scans each channel when performing an active OBSS scan operation." DEFVAL { 20 } ::= { dot11OperationEntry 39 } dot112040BSSCoexistenceManagementSupport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the transmission and reception of the 20/40 BSS Coexistence Management frame." ::= { dot11OperationEntry 40 } dot11OBSSScanActivityThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..100) UNITS "0.01%" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum total time that a STA may be active on the medium during a period of dot11BSSWidthChannelTransitionDelayFactor * dot11BSSWidthTriggerScanInterval seconds without being obligated to perform OBSS Scan operations." DEFVAL { 25 } ::= { dot11OperationEntry 41} -- ********************************************************************** -- * End of dot11Operation TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11Counters TABLE -- ********************************************************************** dot11CountersTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11CountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group containing attributes that are MAC counters. Implemented as a table to allow for multiple instantiations on an agent." ::= { dot11mac 2 } dot11CountersEntry OBJECT-TYPE SYNTAX Dot11CountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11CountersEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11CountersTable 1 } Dot11CountersEntry ::= SEQUENCE { dot11TransmittedFragmentCount Counter32, dot11GroupTransmittedFrameCount Counter32, dot11FailedCount Counter32, dot11RetryCount Counter32, dot11MultipleRetryCount Counter32, dot11FrameDuplicateCount Counter32, dot11RTSSuccessCount Counter32, dot11RTSFailureCount Counter32, dot11AckFailureCount Counter32, dot11ReceivedFragmentCount Counter32, dot11GroupReceivedFrameCount Counter32, dot11FCSErrorCount Counter32, dot11TransmittedFrameCount Counter32, dot11WEPUndecryptableCount Counter32, dot11QosDiscardedFragmentCount Counter32, dot11AssociatedStationCount Counter32, dot11QosCFPollsReceivedCount Counter32, dot11QosCFPollsUnusedCount Counter32, dot11QosCFPollsUnusableCount Counter32, dot11QosCFPollsLostCount Counter32, dot11TransmittedAMSDUCount Counter32, dot11FailedAMSDUCount Counter32, dot11RetryAMSDUCount Counter32, dot11MultipleRetryAMSDUCount Counter32, dot11TransmittedOctetsInAMSDUCount Counter64, dot11AMSDUAckFailureCount Counter32, dot11ReceivedAMSDUCount Counter32, dot11ReceivedOctetsInAMSDUCount Counter64, dot11TransmittedAMPDUCount Counter32, dot11TransmittedMPDUsInAMPDUCount Counter32, dot11TransmittedOctetsInAMPDUCount Counter64, dot11AMPDUReceivedCount Counter32, dot11MPDUInReceivedAMPDUCount Counter32, dot11ReceivedOctetsInAMPDUCount Counter64, dot11AMPDUDelimiterCRCErrorCount Counter32, dot11ImplicitBARFailureCount Counter32, dot11ExplicitBARFailureCount Counter32, dot11ChannelWidthSwitchCount Counter32, dot11TwentyMHzFrameTransmittedCount Counter32, dot11FortyMHzFrameTransmittedCount Counter32, dot11TwentyMHzFrameReceivedCount Counter32, dot11FortyMHzFrameReceivedCount Counter32, dot11PSMPUTTGrantDuration Counter32, dot11PSMPUTTUsedDuration Counter32, dot11GrantedRDGUsedCount Counter32, dot11GrantedRDGUnusedCount Counter32, dot11TransmittedFramesInGrantedRDGCount Counter32, dot11TransmittedOctetsInGrantedRDGCount Counter64, dot11BeamformingFrameCount Counter32, dot11DualCTSSuccessCount Counter32, dot11DualCTSFailureCount Counter32, dot11STBCCTSSuccessCount Counter32, dot11STBCCTSFailureCount Counter32, dot11nonSTBCCTSSuccessCount Counter32, dot11nonSTBCCTSFailureCount Counter32, dot11RTSLSIGSuccessCount Counter32, dot11RTSLSIGFailureCount Counter32, dot11PBACErrors Counter32, dot11DeniedAssociationCounterDueToBSSLoad Counter32, dot11TransmittedMSDUOctetsCount Counter64, dot11ReceivedMSDUOctetsCount Counter64 } dot11TransmittedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a fragment is successfully transmitted. This counter is incremented for an acknowledged MPDU with an individual address in the Address 1 field or an MPDU with a group address in the Address 1 field with the Type subfield equal to Data or Management." ::= { dot11CountersEntry 1 } dot11GroupTransmittedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a group addressed frame is transmitted. This counter is incremented only when the group bit is set in the destination MAC address of a successfully transmitted MSDU. When operating as a STA in an infrastructure BSS, where these frames are directed to the AP, this implies having received an acknowledgment to all associated MPDUs." ::= { dot11CountersEntry 2 } dot11FailedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when an MSDU is not transmitted successfully due to the number of transmit attempts exceeding the dot11ShortRetryLimit." ::= { dot11CountersEntry 3 } dot11RetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when an MSDU is successfully transmitted after one or more retransmissions." ::= { dot11CountersEntry 4 } dot11MultipleRetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when an MSDU is successfully transmitted after more than one retransmission." ::= { dot11CountersEntry 5 } dot11FrameDuplicateCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when a frame is received that the Sequence Control field indicates is a duplicate." ::= { dot11CountersEntry 6 } dot11RTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a CTS frame is received in response to an RTS. This counter increments when a CTS frame is received in response to an RTS." ::= { dot11CountersEntry 7 } dot11RTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when a CTS frame is not received in response to an RTS." ::= { dot11CountersEntry 8 } dot11AckFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when an Ack frame is not received when expected." ::= { dot11CountersEntry 9 } dot11ReceivedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a fragment is received. This counter is incremented for each received MPDU with the Type subfield equal to Data or Management." ::= { dot11CountersEntry 10 } dot11GroupReceivedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a group addressed frame is received. This counter increments when an MSDU is received with the group bit set in the destination MAC address." ::= { dot11CountersEntry 11 } dot11FCSErrorCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when an FCS error is detected in a received MPDU." ::= { dot11CountersEntry 12 } dot11TransmittedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a frame is successfully transmitted. This counter increments for each successfully transmitted MSDU." ::= { dot11CountersEntry 13 } dot11WEPUndecryptableCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when a frame is received with the Protected Frame subfield of the Frame Control field equal to 1 and the WEPOn value for the key mapped to the transmitter's MAC address indicates that the frame should not have been encrypted or that frame is discarded due to the receiving STA not implementing the privacy option." ::= { dot11CountersEntry 14 } dot11QosDiscardedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments for each QoS Data frame that has been discarded." ::= { dot11CountersEntry 15 } dot11AssociatedStationCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a STA associates or disassociates. This counter, only available at AP, increments when a station associates or reassociates. This counter decrements when a station disassociates." ::= { dot11CountersEntry 16 } dot11QosCFPollsReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a CF-Poll is received. This counter increments for each QoS (+)CF-Poll that has been received." ::= { dot11CountersEntry 17 } dot11QosCFPollsUnusedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a CF-Poll is unused. This counter increments for each QoS (+)CF-Poll that has been received but not used." ::= { dot11CountersEntry 18 } dot11QosCFPollsUnusableCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments for each QoS (+)CF-Poll that has been received but could not be used due to the TXOP size being smaller than the time that is required for one frame exchange sequence." ::= { dot11CountersEntry 19 } dot11QosCFPollsLostCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments for each QoS (+)CF-Poll that has been issued where there was no response from the QoS STA." ::= { dot11CountersEntry 20 } dot11TransmittedAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a transmitted A-MSDU is acknowledged. This counter shall be incremented for an acknowledged A-MSDU frame with an individual address in the Address 1 field or an A-MSDU frame with a group address in the Address 1 field." ::= { dot11CountersEntry 21 } dot11FailedAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter shall be incremented when an A-MSDU is not transmitted successfully due to the number of transmit attempts exceeding the dot11ShortRetryLimit." ::= { dot11CountersEntry 22 } dot11RetryAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a transmitted A-MSDU is acknowledged only after one or more retransmissions. This counter shall be incremented when an A-MSDU is successfully transmitted after one or more retransmissions." ::= { dot11CountersEntry 23 } dot11MultipleRetryAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a transmitted A-MSDU is acknowledged only after more than one retransmission. This counter shall be incremented when an A-MSDU is successfully transmitted after more than one retransmission." ::= { dot11CountersEntry 24 } dot11TransmittedOctetsInAMSDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an A-MSDU is transmitted. This counter shall be incremented by the number of octets in the frame body of an A-MSDU frame when an A-MSDU frame is successfully transmitted." ::= { dot11CountersEntry 25 } dot11AMSDUAckFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter shall be incremented when an acknowledgment to an A-MSDU is not received when expected. This acknowledgment can be in an Ack or BlockAck frame." ::= { dot11CountersEntry 26 } dot11ReceivedAMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an A-MSDU is received. This counter shall be incremented for a received A-MSDU frame with the STA's MAC address in the Address 1 field or an A-MSDU frame with a group address in the Address 1 field." ::= { dot11CountersEntry 27 } dot11ReceivedOctetsInAMSDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an A-MSDU is received. This counter shall be incremented by the number of octets in the frame body of an A-MSDU frame when an A-MSDU frame is received." ::= { dot11CountersEntry 28 } dot11TransmittedAMPDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an A-MPDU is transmitted. This counter shall be incremented when an A-MPDU is transmitted." ::= { dot11CountersEntry 29 } dot11TransmittedMPDUsInAMPDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an A-MPDU is transmitted. This counter shall increment by the number of MPDUs in the A-MPDU when an A-MPDU is transmitted." ::= { dot11CountersEntry 30 } dot11TransmittedOctetsInAMPDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an A-MPDU is transmitted. This counter shall be incremented by the number of octets in the A-MPDU frame when an A-MPDU frame is transmitted." ::= { dot11CountersEntry 31 } dot11AMPDUReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an A-MPDU is received. This counter shall be incremented when the MAC receives an A-MPDU from the PHY." ::= { dot11CountersEntry 32 } dot11MPDUInReceivedAMPDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an A-MPDU is received. This counter shall be incremented by the number of MPDUs received in the A-MPDU when an A-MPDU is received." ::= { dot11CountersEntry 33 } dot11ReceivedOctetsInAMPDUCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an A-MPDU is received. This counter shall be incremented by the number of octets in the A-MPDU frame when an A-MPDU frame is received." ::= { dot11CountersEntry 34 } dot11AMPDUDelimiterCRCErrorCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter shall be incremented when an MPDU delimiter has a CRC error when this is the first CRC error in the received A-MPDU or when the previous delimiter has been decoded correctly." ::= { dot11CountersEntry 35 } dot11ImplicitBARFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter shall be incremented when the expected BlockAck frame is not received in response to an implicit block ack request." ::= { dot11CountersEntry 36 } dot11ExplicitBARFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter shall be incremented when the expected BlockAck frame is not received in response to a BlockAckReq frame." ::= { dot11CountersEntry 37 } dot11ChannelWidthSwitchCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the bandwidth is switched. This counter shall be increment when the bandwidth used is switched from 20 to 40 or vice versa." ::= { dot11CountersEntry 38 } dot11TwentyMHzFrameTransmittedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a frame is transmitted only on the primary channel. This counter shall be incremented when a frame is transmitted only on the primary channel." ::= { dot11CountersEntry 39 } dot11FortyMHzFrameTransmittedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a frame is transmitted on both control and secondary channels. This counter shall be incremented when a frame is transmitted on both control and secondary channels." ::= { dot11CountersEntry 40 } dot11TwentyMHzFrameReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a frame is received only on the primary channel. This counter shall be incremented when a frame is received only on the primary channel." ::= { dot11CountersEntry 41 } dot11FortyMHzFrameReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a frame is received on both the control and secondary channels. This counter shall be incremented when a frame is received on both the control and secondary channels." ::= { dot11CountersEntry 42 } dot11PSMPUTTGrantDuration OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a PSMP-UTT is granted. This counter contains the cumulative duration of PSMP-UTT granted to the STA, in units of 4 microseconds." ::= { dot11CountersEntry 43 } dot11PSMPUTTUsedDuration OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a PSMP-UTT is used. This counter contains the cumulative duration of transmission by the STA during its allocated PSMP-UTT, in units of 4 microseconds" ::= { dot11CountersEntry 44 } dot11GrantedRDGUsedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an RDG is used. This counter at the RD initiator shall be incremented when an allocated RDG is used by the station, apart from transmitting a response frame such as Ack or BlockAck frames." ::= { dot11CountersEntry 45 } dot11GrantedRDGUnusedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an RDG is not used. This counter at the initiator shall be incremented when an allocated RDG is not used by the station, apart from transmitting a response frame such as Ack or BlockAck frames." ::= { dot11CountersEntry 46 } dot11TransmittedFramesInGrantedRDGCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an RDG is used. This counter at the initiator shall be incremented for every frame, other than response frames such as Ack or BlockAck frames, transmitted by the station during a granted RDG." ::= { dot11CountersEntry 47 } dot11TransmittedOctetsInGrantedRDGCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an RDG is used. This counter at the initiator shall be incremented by the number of octets in the frame body of a frame, other than response frames such as Ack or BlockAck frames, transmitted by the station during a granted RDG." ::= { dot11CountersEntry 48 } dot11BeamformingFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a frame with beamforming parameters is sent. This counter shall be incremented when the transmitter sends a frame with new/updated beamforming parameters." ::= { dot11CountersEntry 49 } dot11DualCTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a dual CTS is sent. This counter shall be incremented when AP sends a dual CTS in response to a STA initiating TXOP in extended range." ::= { dot11CountersEntry 50 } dot11DualCTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a dual CTS is not sent. This counter shall be incremented when AP fails to send a dual CTS in response to a STA initiating TXOP in extended range." ::= { dot11CountersEntry 51 } dot11STBCCTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when no collision is detected. This counter shall be incremented when AP does not detect a collision PIFS after sending a CTS to self STBC frame in extended range." ::= { dot11CountersEntry 52 } dot11STBCCTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a collision is detected. This counter shall be incremented when AP detects a collision PIFS after sending a CTS to self STBC frame in extended range." ::= { dot11CountersEntry 53 } dot11nonSTBCCTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when no collision is detected. This counter shall be incremented when AP does not detect a collision PIFS after sending a CTS to self that is an non-STBC frame in extended range." ::= { dot11CountersEntry 54 } dot11nonSTBCCTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a collision is detected. This counter shall be incremented when AP detects a collision PIFS after sending a CTS to self that is an non-STBC frame in extended range." ::= { dot11CountersEntry 55 } dot11RTSLSIGSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the MAC when the condition described below occurs. This counter shall be incremented when the duration/ID field is set according to the rules of L-SIG TXOP protection in the received CTS following a transmission of RTS in L-SIG TXOP protection mode." ::= { dot11CountersEntry 56 } dot11RTSLSIGFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a status variable. It is written by the MAC when the condition described below occurs. This counter shall be incremented when the duration/ID field is not set according to the rules of L-SIG TXOP protection in the received CTS following a transmission of RTS in L-SIG TXOP protection mode." ::= { dot11CountersEntry 57 } dot11PBACErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This variable indicates the number of errors encountered in the PBAC procedures." ::= { dot11CountersEntry 58} dot11DeniedAssociationCounterDueToBSSLoad OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when the condition described below occurs. This counter, available at a WNM AP, shall increment when an (re)association request is denied because the AP has insufficient bandwidth to handle the additional STA." ::= { dot11CountersEntry 59} dot11TransmittedMSDUOctetsCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an MSDU is successfully transmitted. This counter is incremented by the number of octets in the MSDU when an MSDU is successfully transmitted." ::= { dot11CountersEntry 60 } dot11ReceivedMSDUOctetsCount OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when an MSDU is received that is addressed to the STA (either individually or globally). This counter is incremented by the number of octets in the MSDU." ::= { dot11CountersEntry 61 } -- ********************************************************************** -- * End of dot11Counters TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11GroupAddresses TABLE -- ********************************************************************** dot11GroupAddressesTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11GroupAddressesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual table containing a set of MAC addresses identifying the multicast-group addresses for which this STA receives frames." ::= { dot11mac 3 } dot11GroupAddressesEntry OBJECT-TYPE SYNTAX Dot11GroupAddressesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the Group Addresses Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11GroupAddressesIndex } ::= { dot11GroupAddressesTable 1 } Dot11GroupAddressesEntry ::= SEQUENCE { dot11GroupAddressesIndex InterfaceIndex, dot11GroupAddress MacAddress, dot11GroupAddressesStatus RowStatus } dot11GroupAddressesIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the Group Addresses Table." ::= { dot11GroupAddressesEntry 1 } dot11GroupAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. MAC address identifying multicast-group addresses from which this STA receives frames." ::= { dot11GroupAddressesEntry 2 } dot11GroupAddressesStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status column used for creating, modifying, and deleting instances of the columnar objects in the Group Addresses Table." DEFVAL { active } ::= { dot11GroupAddressesEntry 3 } -- ********************************************************************** -- * End of dot11GroupAddresses TABLE -- ********************************************************************** -- ********************************************************************** -- * SMT EDCA Config TABLE -- ********************************************************************** dot11EDCATable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11EDCAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual table for EDCA parameter values at a non-AP STA. This table contains the four entries of the EDCA parameters corresponding to four possible ACs. Index 1 corresponds to AC_BK, index 2 to AC_BE, index 3 to AC_VI, and index 4 to AC_VO. An AP uses this table to select the values to advertise in the EDCA Parameter Set element." ::= { dot11mac 4 } dot11EDCAEntry OBJECT-TYPE SYNTAX Dot11EDCAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the EDCA Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11EDCATableIndex } ::= { dot11EDCATable 1 } Dot11EDCAEntry ::= SEQUENCE { dot11EDCATableIndex Unsigned32, dot11EDCATableCWmin Unsigned32, dot11EDCATableCWmax Unsigned32, dot11EDCATableAIFSN Unsigned32, dot11EDCATableTXOPLimit Unsigned32, dot11EDCATableMSDULifetime Unsigned32, dot11EDCATableMandatory TruthValue } dot11EDCATableIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the EDCA Table. The value of this variable is 1, if the value of the AC is AC_BK. 2, if the value of the AC is AC_BE. 3, if the value of the AC is AC_VI. 4, if the value of the AC is AC_VO." ::= { dot11EDCAEntry 1 } dot11EDCATableCWmin OBJECT-TYPE SYNTAX Unsigned32 (0..32767) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable at a non-AP QoS STA and a control variable at a QoS AP. At a QoS AP, it is written by an external management entity and used to select the value to advertise in the EDCA Parameter Set element. At a non-AP QoS STA, it is written by the MAC upon receiving an EDCA Parameter Set element. Changes take effect as soon as practical in the implementation. This attribute specifies the value of the minimum size of the window that is used by a STA for a particular AC for generating a random number for the backoff. The value of this attribute is such that it could always be expressed in the form of 2^X - 1, where X is an integer. See Table 9-155 and Table 9-156." ::= { dot11EDCAEntry 2 } dot11EDCATableCWmax OBJECT-TYPE SYNTAX Unsigned32 (0..32767) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable at a non-AP QoS STA and a control variable at a QoS AP. At a QoS AP, it is written by an external management entity and used to select the value to advertise in the EDCA Parameter Set element. At a non-AP QoS STA, it is written by the MAC upon receiving an EDCA Parameter Set element. Changes take effect as soon as practical in the implementation. This attribute specifies the value of the maximum size of the window that is used by a STA for a particular AC for generating a random number for the backoff. The value of this attribute is such that it could always be expressed in the form of 2^X - 1, where X is an integer. See Table 9-155 and Table 9-156." ::= { dot11EDCAEntry 3 } dot11EDCATableAIFSN OBJECT-TYPE SYNTAX Unsigned32 (2..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable at a non-AP QoS STA and a control variable at a QoS AP. At a QoS AP, it is written by an external management entity and used to select the value to advertise in the EDCA Parameter Set element. At a non-AP QoS STA, it is written by the MAC upon receiving an EDCA Parameter Set element. Changes take effect as soon as practical in the implementation. This attribute specifies the number of slots, after a SIFS, that the STA, for a particular AC, senses the medium idle either before transmitting or executing a backoff. See Table 9-155 and Table 9-156." ::= { dot11EDCAEntry 4 } dot11EDCATableTXOPLimit OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "32 microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable at a non-AP QoS STA and a control variable at a QoS AP. At a QoS AP, it is written by an external management entity and used to select the value to advertise in the EDCA Parameter Set element. At a non-AP QoS STA, it is written by the MAC upon receiving an EDCA Parameter Set element. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum duration of an EDCA TXOP for a given AC, for a non-AP non-OCB STA. The default value for this attribute is given (in different units) in Table 9-155." ::= { dot11EDCAEntry 5 } dot11EDCATableMSDULifetime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable at a non-AP STA. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum duration an MSDU/MMPDU, for a given AC, would be retained by the MAC at the non-AP STA before it is discarded." DEFVAL { 500 } ::= { dot11EDCAEntry 6 } dot11EDCATableMandatory OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a status variable at a non-AP QoS STA and a control variable at a QoS AP. At a QoS AP, it is written by an external management entity and used to select the value to advertise in the EDCA Parameter Set element. At a non-AP QoS STA, it is written by the MAC upon receiving an EDCA Parameter Set element. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that admission control is mandatory for the given AC. When false, this attribute indicates that admission control is not mandatory for the given AC." DEFVAL { false } ::= { dot11EDCAEntry 7 } -- ********************************************************************** -- * End of SMT EDCA Config TABLE -- ********************************************************************** -- ********************************************************************** -- * SMT AP EDCA Config TABLE -- ********************************************************************** dot11QAPEDCATable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11QAPEDCAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Conceptual table for EDCA default parameter values at the AP. This table contains the four entries of the EDCA parameters corresponding to four possible ACs. Index 1 corresponds to AC_BK, index 2 to AC_BE, index 3 to AC_VI, and index 4 to AC_VO." ::= { dot11mac 5 } dot11QAPEDCAEntry OBJECT-TYPE SYNTAX Dot11QAPEDCAEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the EDCA Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11QAPEDCATableIndex } ::= { dot11QAPEDCATable 1 } Dot11QAPEDCAEntry ::= SEQUENCE { dot11QAPEDCATableIndex Unsigned32, dot11QAPEDCATableCWmin Unsigned32, dot11QAPEDCATableCWmax Unsigned32, dot11QAPEDCATableAIFSN Unsigned32, dot11QAPEDCATableTXOPLimit Unsigned32, dot11QAPEDCATableMSDULifetime Unsigned32, dot11QAPEDCATableMandatory TruthValue } dot11QAPEDCATableIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the EDCA Table. The value of this variable is 1, if the value of the AC is AC_BK. 2, if the value of the AC is AC_BE. 3, if the value of the AC is AC_VI. 4, if the value of the AC is AC_VO." ::= { dot11QAPEDCAEntry 1 } dot11QAPEDCATableCWmin OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the value of the minimum size of the window that is used by an AP for a particular AC for generating a random number for the backoff. The value of this attribute is such that it could always be expressed in the form of 2^X - 1, where X is an integer. The default value for this attribute is aCWmin, if dot11QAPEDCATableIndex is 1 or 2. (aCWmin+1)/2 - 1, if dot11QAPEDCATableIndex is 3. (aCWmin+1)/4 - 1, if dot11QAPEDCATableIndex is 4." ::= { dot11QAPEDCAEntry 2 } dot11QAPEDCATableCWmax OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the value of the maximum size of the window that is used by an AP for a particular AC for generating a random number for the backoff. The value of this attribute is such that it could always be expressed in the form of 2^X - 1, where X is an integer. The default value for this attribute is aCWmax, if dot11QAPEDCATableIndex is 1. 4*(aCWmin+1) - 1, if dot11QAPEDCATableIndex is 2. aCWmin, if dot11QAPEDCATableIndex is 3. (aCWmin+1)/2 - 1, if dot11QAPEDCATableIndex is 4." ::= { dot11QAPEDCAEntry 3 } dot11QAPEDCATableAIFSN OBJECT-TYPE SYNTAX Unsigned32 (1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of slots, after a SIFS, that the AP, for a particular AC, senses the medium idle either before transmitting or executing a backoff. The default value for this attribute is 7, if dot11QAPEDCATableIndex is 1, 3, if dot11QAPEDCATableIndex is 2 1, otherwise." ::= { dot11QAPEDCAEntry 4 } dot11QAPEDCATableTXOPLimit OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "32 microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum duration of an EDCA TXOP for a given AC, for an AP. The default value for this attribute is given (in different units) in Table 9-155." ::= { dot11QAPEDCAEntry 5 } dot11QAPEDCATableMSDULifetime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the maximum duration an MSDU/MMPDU, for a given AC, would be retained by the MAC at the AP before it is discarded." DEFVAL { 500 } ::= { dot11QAPEDCAEntry 6 } dot11QAPEDCATableMandatory OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that admission control is mandatory for the given AC. When false, this attribute indicates that admission control is not mandatory for the given AC. The default value for this parameter is false." ::= { dot11QAPEDCAEntry 7 } -- ********************************************************************** -- * End of SMT AP EDCA Config TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11QosCounters TABLE -- ********************************************************************** dot11QosCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11QosCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group containing attributes that are MAC counters implemented as a table to allow for multiple instantiations on an agent." ::= { dot11mac 6 } dot11QosCountersEntry OBJECT-TYPE SYNTAX Dot11QosCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the QoSCounters Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11QosCountersIndex } ::= { dot11QosCountersTable 1 } Dot11QosCountersEntry ::= SEQUENCE { dot11QosCountersIndex Unsigned32, dot11QosTransmittedFragmentCount Counter32, dot11QosFailedCount Counter32, dot11QosRetryCount Counter32, dot11QosMultipleRetryCount Counter32, dot11QosFrameDuplicateCount Counter32, dot11QosRTSSuccessCount Counter32, dot11QosRTSFailureCount Counter32, dot11QosAckFailureCount Counter32, dot11QosReceivedFragmentCount Counter32, dot11QosTransmittedFrameCount Counter32, dot11QosDiscardedFrameCount Counter32, dot11QosMPDUsReceivedCount Counter32, dot11QosRetriesReceivedCount Counter32 } dot11QosCountersIndex OBJECT-TYPE SYNTAX Unsigned32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the QoSCounters Table. The value of this variable is equal to TID + 1." ::= { dot11QosCountersEntry 1 } dot11QosTransmittedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a QoS fragment is transmitted. This counter is incremented for an acknowledged MPDU, for a particular UP, with an individual address in the Address 1 field or an MPDU with a group address in the Address 1 field, either belonging to a particular TID. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 2 } dot11QosFailedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when an MSDU, for a particular UP, is not transmitted successfully due to the number of transmit attempts exceeding the dot11ShortRetryLimit. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 3 } dot11QosRetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when an MSDU, of a particular UP, is successfully transmitted after one or more retransmissions. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 4 } dot11QosMultipleRetryCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when an MSDU, of a particular UP, is successfully transmitted after more than one retransmissions. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 5 } dot11QosFrameDuplicateCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when a frame, of a particular UP, is received that the Sequence Control field indicates is a duplicate. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 6 } dot11QosRTSSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a CTS frame is received in response to an RTS. This counter increments when a CTS frame is received in response to an RTS that has been sent for the transmission of an MPDU of a particular UP. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 7 } dot11QosRTSFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when a CTS frame is not received in response to an RTS that has been sent for the transmission of an MPDU of a particular UP. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 8 } dot11QosAckFailureCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments when an Ack frame is not received in response to an MPDU of a particular UP. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 9 } dot11QosReceivedFragmentCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a QoS fragment is received. This counter is incremented for each received MPDU with the Type subfield equal to Data of a particular UP. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 10 } dot11QosTransmittedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a QoS frame is transmitted. This counter increments for each successfully transmitted MSDU of a particular UP. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 11 } dot11QosDiscardedFrameCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments for each Discarded MSDU of a particular UP. This counter has relevance only for TIDs between 0 and 7." ::= { dot11QosCountersEntry 12 } dot11QosMPDUsReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when a QoS MPDU is received. This counter increments for each received MPDU of a particular TID." ::= { dot11QosCountersEntry 13 } dot11QosRetriesReceivedCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC when the condition described below occurs. This counter increments for each received MPDU of a particular TID with the Retry subfield equal to 1." ::= { dot11QosCountersEntry 14 } -- ********************************************************************** -- * End of dot11QosCounters TABLE -- ********************************************************************** -- ********************************************************************** -- * Resource Type Attribute Templates -- ********************************************************************** dot11ResourceTypeIDName OBJECT-TYPE SYNTAX DisplayString (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "Contains the name of the Resource Type ID managed object. The attribute is read-only and always contains the value RTID. This attribute value is not used as a naming attribute for any other managed object class." REFERENCE "IEEE Std 802.1F-1993, A.7" DEFVAL { "RTID" } ::= { dot11resAttribute 1 } -- ********************************************************************** -- * dot11ResourceInfo TABLE -- ********************************************************************** dot11ResourceInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11ResourceInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "provides a means of indicating, in data readable from a managed object, information that identifies the source of the implementation." REFERENCE "IEEE Std 802.1F-1993, A.7. Note that this standard has been withdrawn." ::= { dot11resAttribute 2 } dot11ResourceInfoEntry OBJECT-TYPE SYNTAX Dot11ResourceInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11ResourceInfo Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11ResourceInfoTable 1 } Dot11ResourceInfoEntry ::= SEQUENCE { dot11manufacturerOUI OCTET STRING, dot11manufacturerName DisplayString, dot11manufacturerProductName DisplayString, dot11manufacturerProductVersion DisplayString } dot11manufacturerOUI OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Takes the value of an IEEE assigned unique identifier (OUI or CID)." ::= { dot11ResourceInfoEntry 1 } dot11manufacturerName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. A printable string used to identify the manufacturer of the resource. Maximum string length is 128 octets." ::= { dot11ResourceInfoEntry 2 } dot11manufacturerProductName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. A printable string used to identify the manufacturer's product name of the resource. Maximum string length is 128 octets." ::= { dot11ResourceInfoEntry 3 } dot11manufacturerProductVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. Printable string used to identify the manufacturer's product version of the resource. Maximum string length is 128 octets." ::= { dot11ResourceInfoEntry 4 } -- ********************************************************************** -- * End of dot11ResourceInfo TABLE -- ********************************************************************** -- ******************************************************************* -- * dot11DMGOperation TABLE -- ******************************************************************* dot11DMGOperationTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11DMGOperationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a Table management object. The dot11DMGOperation Table" ::= { dot11mac 8 } dot11DMGOperationEntry OBJECT-TYPE SYNTAX Dot11DMGOperationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry in the dot11DMGOperation Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11DMGOperationTable 1 } Dot11DMGOperationEntry ::= SEQUENCE { dot11MaxLostBeacons Unsigned32, dot11MinBHIDuration Unsigned32, dot11PSRequestSuspensionInterval Unsigned32, dot11BroadcastSTAInfoDuration Unsigned32, dot11NbrOfChangeBeacons Unsigned32, dot11ImplicitHandoverLostBeacons Unsigned32, dot11MinPPDuration Unsigned32, dot11SPIdleTimeout Unsigned32, dot11QABTimeout Unsigned32, dot11ClusterEnableTime Unsigned32, dot11PNWarningThresholdLow Unsigned32, dot11PNWarningThresholdHigh INTEGER, dot11BeaconSPDuration Unsigned32, dot11PNExhaustionThresholdLow Unsigned32, dot11PNExhaustionThresholdHigh INTEGER, dot11MaxNumberOfClusteringMonitoringPeriods Unsigned32, dot11DMGEcssPolicyDetailUpdateDurationMax Unsigned32, dot11DMGEcssClusterReportDurationMin Unsigned32, dot11DMGNavSync Unsigned32 } dot11MaxLostBeacons OBJECT-TYPE SYNTAX Unsigned32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Maximum Number of Lost Beacons" DEFVAL { 4 } ::= { dot11DMGOperationEntry 1 } dot11MinBHIDuration OBJECT-TYPE SYNTAX Unsigned32 (1..100000) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Minimum Beacon Header Interval duration." DEFVAL { 5000 } ::= { dot11DMGOperationEntry 2 } dot11PSRequestSuspensionInterval OBJECT-TYPE SYNTAX Unsigned32 (1..64) UNITS "beacon intervals" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. PS Request Suspension Interval" DEFVAL { 8 } ::= { dot11DMGOperationEntry 3 } dot11BroadcastSTAInfoDuration OBJECT-TYPE SYNTAX Unsigned32 (1..512) UNITS "beacon intervals" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Broadcast STA Information Duration." DEFVAL { 32 } ::= { dot11DMGOperationEntry 5 } dot11NbrOfChangeBeacons OBJECT-TYPE SYNTAX Unsigned32 (1..32) UNITS "beacon intervals" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Number of Change Beacons." DEFVAL { 4 } ::= { dot11DMGOperationEntry 6 } dot11ImplicitHandoverLostBeacons OBJECT-TYPE SYNTAX Unsigned32 (1..32) UNITS "beacon intervals" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Implicit handover lost beacons." DEFVAL { 8 } ::= { dot11DMGOperationEntry 7 } dot11MinPPDuration OBJECT-TYPE SYNTAX Unsigned32 (1..100000) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. The MinPPDuration subfield indicates the minimum duration of the PP and GP as part of the dynamic allocation of service period mechanism." DEFVAL { 200 } ::= { dot11DMGOperationEntry 8 } dot11SPIdleTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..100000) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. The SPIdleTimeout subfield indicates time during which a STA expects to receive a frame from its partner STA." DEFVAL { 200 } ::= { dot11DMGOperationEntry 9 } dot11QABTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..64000) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Quiet Adjacent BSS Operation Timeout." DEFVAL { 1000 } ::= { dot11DMGOperationEntry 10 } dot11ClusterEnableTime OBJECT-TYPE SYNTAX Unsigned32 (1..32) UNITS "beacon intervals" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Frequency with which a non-AP and non-PCP is allowed to retransmit a cluster request element to its AP or PCP." DEFVAL { 8 } ::= { dot11DMGOperationEntry 11 } dot11PNWarningThresholdLow OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) UNITS "packet number" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Threshold used for generating a warning to the MLME about a potential PN exhaustion. Threshold is a 48-bit integer. This field contains the least significant 32 bits of the threshold." DEFVAL { 4294967295 } ::= { dot11DMGOperationEntry 12 } dot11PNWarningThresholdHigh OBJECT-TYPE SYNTAX INTEGER (0..65535) UNITS "packet number" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Threshold used for generating a warning to the MLME about a potential PN exhaustion. Threshold is a 48-bit integer. This field contains the most significant 16 bits of the threshold." DEFVAL { 65535 } ::= { dot11DMGOperationEntry 13 } dot11BeaconSPDuration OBJECT-TYPE SYNTAX Unsigned32 (1..100000) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. The size of a Beacon SP used for AP or PCP clustering." DEFVAL { 600 } ::= { dot11DMGOperationEntry 14 } dot11PNExhaustionThresholdLow OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) UNITS "packet number" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Threshold used for indicating an imminent PN exhaustion. Threshold is a 48-bit integer. This field contains the least significant 32 bits of the threshold." DEFVAL { 4294967295 } ::= { dot11DMGOperationEntry 15 } dot11PNExhaustionThresholdHigh OBJECT-TYPE SYNTAX INTEGER (0..65535) UNITS "packet number" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Threshold used for indicating an imminent PN exhaustion. Threshold is a 48-bit integer. This field contains the most significant 16 bits of the threshold." DEFVAL { 65535 } ::= { dot11DMGOperationEntry 16 } dot11MaxNumberOfClusteringMonitoringPeriods OBJECT-TYPE SYNTAX Unsigned32 (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Number of clustering monitoring periods until determination of the loss of an S-AP or S-PCP." DEFVAL { 3 } ::= { dot11DMGOperationEntry 17 } dot11DMGEcssPolicyDetailUpdateDurationMax OBJECT-TYPE SYNTAX Unsigned32 (10..30000) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Maximum duration between attempts by a member AP or member PCP in a centralized AP or PCP cluster to receive a DMG Beacon frame from the S-AP of the centralized AP or PCP cluster" DEFVAL { 1000 } ::= { dot11DMGOperationEntry 18 } dot11DMGEcssClusterReportDurationMin OBJECT-TYPE SYNTAX Unsigned32 (100..36000000) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Minimum duration between the transmission of interference reports by a member AP or member PCP in a centralized AP or PCP cluster to the S-AP of the centralized AP or PCP cluster" DEFVAL { 1000 } ::= { dot11DMGOperationEntry 19 } dot11DMGNavSync OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Delay to be used by a DMG STA prior to transmitting a Probe Request frame." DEFVAL { 0 } ::= { dot11DMGOperationEntry 20 } -- ******************************************************************* -- * End of dot11DMGOperation TABLE -- ******************************************************************* -- ******************************************************************* -- * dot11DMGCounters TABLE -- ******************************************************************* dot11DMGCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11DMGCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a Table management object. The dot11DMGCountersTable Table" ::= { dot11mac 9 } dot11DMGCountersEntry OBJECT-TYPE SYNTAX Dot11DMGCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry in the dot11DMGCountersTable Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11DMGCountersTable 1 } Dot11DMGCountersEntry ::= SEQUENCE { dot11RSNAStatsGCMPReplays Unsigned32, dot11RSNAStatsRobustMgmtGCMPReplays Unsigned32 } dot11RSNAStatsGCMPReplays OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME or an external management entity. Counter for the number of times an MPDU with the Type subfield equal to Data is discarded due to PN violation." DEFVAL { 0 } ::= { dot11DMGCountersEntry 1 } dot11RSNAStatsRobustMgmtGCMPReplays OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME or an external management entity. Counter for the number of times a Management frame is discarded due to PN violation." DEFVAL { 0 } ::= { dot11DMGCountersEntry 2 } -- ******************************************************************* -- * End of dot11DMGCounters TABLE -- ******************************************************************* -- ******************************************************************* -- * dot11BSSStatisticsTable TABLE -- ******************************************************************* dot11BSSStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11BSSStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a Table management object. The dot11BSSStatisticsTable Table contains objects related to BSS Statistics. It is present only in an AP." ::= { dot11mac 10 } dot11BSSStatisticsEntry OBJECT-TYPE SYNTAX Dot11BSSStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry in the dot11BSSStatisticsTable Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11BSSStatisticsTable 1 } Dot11BSSStatisticsEntry ::= SEQUENCE { dot11BSSLoadChannelUtilization Unsigned32, dot11BSSLoadAvailableAdmissionCapacity Unsigned32, dot11BSSLoadAssocAttemptCount Unsigned32, dot11BSSLoadAssocFailCount Unsigned32, dot11BSSLoadReassocAttemptCount Unsigned32, dot11BSSLoadReassocFailCount Unsigned32 } dot11BSSLoadChannelUtilization OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MLME. This object indicates the percentage of time, linearly scaled with 255 representing 100%, that the AP sensed the medium was busy, as indicated by either the physical or virtual carrier sense (CS) mechanism." DEFVAL { 0 } ::= { dot11BSSStatisticsEntry 1 } dot11BSSLoadAvailableAdmissionCapacity OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "32 microseconds/second" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MLME. This object indicates the remaining amount of medium time available via explicit admission control." DEFVAL { 0 } ::= { dot11BSSStatisticsEntry 2 } dot11BSSLoadAssocAttemptCount OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MLME. This object contains the count of the number of association procedures started at the AP. It reports the count of such events since the AP started the operation of its BSS (i.e., since the last MLME-START.request primitive)." DEFVAL { 0 } ::= { dot11BSSStatisticsEntry 3 } dot11BSSLoadAssocFailCount OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MLME. This object contains the count of the number of unsuccessful association procedures at the AP (i.e., it is the number of association procedures started less those that completed successfully). It reports the count of such events since the AP started the operation of its BSS (i.e., since the last MLME-START.request primitive)." DEFVAL { 0 } ::= { dot11BSSStatisticsEntry 4 } dot11BSSLoadReassocAttemptCount OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MLME. This object contains the count of the number of reassociation procedures started at the AP. It reports the count of such events since the AP started the operation of its BSS (i.e., since the last MLME-START.request primitive)." DEFVAL { 0 } ::= { dot11BSSStatisticsEntry 5 } dot11BSSLoadReassocFailCount OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MLME. This object contains the count of the number of unsuccessful reassociation procedures at the AP (i.e., it is the number of reassociation procedures started less those that completed successfully). It reports the count of such events since the AP started the operation of its BSS (i.e., since the last MLME-START.request primitive)." DEFVAL { 0 } ::= { dot11BSSStatisticsEntry 6 } -- ********************************************************************** -- * End of dot11BSSStatisticsTable TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11CDMGOperation TABLE -- ********************************************************************** dot11CDMGOperationTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11CDMGOperationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a Table management object. The dot11CDMGOperation Table" ::= { dot11mac 11 } dot11CDMGOperationEntry OBJECT-TYPE SYNTAX Dot11CDMGOperationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry in the dot11CDMGOperation Table. ifIndex - Each IEEE Std 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11CDMGOperationTable 1 } Dot11CDMGOperationEntry ::= SEQUENCE { dot11DCSTimeout Unsigned32 } dot11DCSTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..64000) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Dynamic channel selection timeout (in milliseconds)" DEFVAL { 1000 } ::= { dot11CDMGOperationEntry 1 } -- ********************************************************************** -- * End of dot11CDMGOperation TABLE -- ********************************************************************** -- ********************************************************************** -- * PHY Attribute Templates -- ********************************************************************** -- ********************************************************************** -- * dot11PhyOperation TABLE -- ********************************************************************** dot11PhyOperationTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyOperationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "PHY level attributes concerned with operation. Implemented as a table indexed on ifIndex to allow for multiple instantiations on an Agent." ::= { dot11phy 1 } dot11PhyOperationEntry OBJECT-TYPE SYNTAX Dot11PhyOperationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyOperation Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyOperationTable 1 } Dot11PhyOperationEntry ::= SEQUENCE { dot11PHYType INTEGER, dot11CurrentRegDomain Unsigned32, dot11TempType INTEGER } dot11PHYType OBJECT-TYPE SYNTAX INTEGER { dsss(2), ofdm(4), hrdsss(5), erp(6), ht(7), dmg(8), vht(9), tvht(10), s1g(11), cdmg(12), cmmg(13)} MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. This is an 8-bit integer value that identifies the supported PHY type. Currently defined values and their corresponding PHY types are: DSSS 2.4 GHz = 2, OFDM = 4, HRDSSS = 5, ERP = 6, HT = 7, DMG = 8, VHT = 9, TVHT = 10, S1G = 11, CDMG = 12, CMMG = 13" ::= { dot11PhyOperationEntry 1 } dot11CurrentRegDomain OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized. The current regulatory domain this instance of the PHY is supporting. This object corresponds to one of the RegDomains listed in dot11RegDomainsSupported." ::= { dot11PhyOperationEntry 2 } dot11TempType OBJECT-TYPE SYNTAX INTEGER { tempType1(1), tempType2(2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The use of dot11TempType is deprecated because the associated behavior has been removed from IEEE Std 802.11-2016, and this entity may be removed in a later revision of the standard. This is a status variable. It is written by the PHY. There are different operating temperature requirements dependent on the anticipated environmental conditions. This attribute describes the current PHY's operating temperature range capability. Currently defined values and their corresponding temperature ranges are: Type 1 = X'01'-Commercial range of 0 to 40 degrees C, Type 2 = X'02'-Industrial range of -30 to 70 degrees C." ::= { dot11PhyOperationEntry 3 } -- ********************************************************************** -- * End of dot11PhyOperation TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PhyAntenna TABLE -- ********************************************************************** dot11PhyAntennaTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyAntennaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group of attributes for PhyAntenna. Implemented as a table indexed on ifIndex to allow for multiple instances on an agent." ::= { dot11phy 2} dot11PhyAntennaEntry OBJECT-TYPE SYNTAX Dot11PhyAntennaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyAntenna Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyAntennaTable 1 } Dot11PhyAntennaEntry ::= SEQUENCE { dot11CurrentTxAntenna Unsigned32, dot11DiversitySupportImplemented INTEGER, dot11CurrentRxAntenna Unsigned32, dot11AntennaSelectionOptionImplemented TruthValue, dot11TransmitExplicitCSIFeedbackASOptionImplemented TruthValue, dot11TransmitIndicesFeedbackASOptionImplemented TruthValue, dot11ExplicitCSIFeedbackASOptionImplemented TruthValue, dot11TransmitIndicesComputationASOptionImplemented TruthValue, dot11ReceiveAntennaSelectionOptionImplemented TruthValue, dot11TransmitSoundingPPDUOptionImplemented TruthValue, dot11NumberOfActiveRxAntennas Unsigned32 } dot11CurrentTxAntenna OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The current antenna being used to transmit. This value is one of the values appearing in dot11TxAntennaImplemented. This may be used by a management agent to control which antenna is used for transmission." ::= { dot11PhyAntennaEntry 1 } dot11DiversitySupportImplemented OBJECT-TYPE SYNTAX INTEGER { fixedlist(1), notsupported(2), dynamic(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This implementation's support for diversity, encoded as: X'01'-diversity is available and is performed over the fixed list of antennas defined in dot11DiversitySelectionRxImplemented. X'02'-diversity is not supported. X'03'-diversity is supported and control of diversity is also available, in which case the attribute dot11DiversitySelectionRxImplemented can be dynamically modified by the LME." ::= { dot11PhyAntennaEntry 2 } dot11CurrentRxAntenna OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. The current antenna being used to receive, if dot11DiversitySupportImplemented indicates that diversity is not supported. The selected antenna is one of the antennae marked for receive in the dot11AntennasListTable." ::= { dot11PhyAntennaEntry 3 } dot11AntennaSelectionOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that ASEL is supported by the station implementation." ::= { dot11PhyAntennaEntry 4 } dot11TransmitExplicitCSIFeedbackASOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the transmit ASEL based on explicit CSI feedback is supported by the station implementation." ::= { dot11PhyAntennaEntry 5 } dot11TransmitIndicesFeedbackASOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the transmit ASEL based on antenna indices feedback is supported by the station implementation." ::= { dot11PhyAntennaEntry 6 } dot11ExplicitCSIFeedbackASOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the computation of CSI and feedback the results to support the peer to do ASEL is supported by the station implementation." ::= { dot11PhyAntennaEntry 7 } dot11TransmitIndicesComputationASOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the transmit ASEL based on antenna indices selection computation and feedback the results to support the peer to do ASEL is supported by the station implementation." ::= { dot11PhyAntennaEntry 8 } dot11ReceiveAntennaSelectionOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the receive ASEL is supported by the station implementation." ::= { dot11PhyAntennaEntry 9 } dot11TransmitSoundingPPDUOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the transmission of sounding PPDUs is supported by the station implementation." ::= { dot11PhyAntennaEntry 10 } dot11NumberOfActiveRxAntennas OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. This attribute indicates the number of current active antennas being used to receive." ::= { dot11PhyAntennaEntry 11 } -- ********************************************************************** -- * End of dot11PhyAntenna TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PhyTxPower TABLE -- ********************************************************************** dot11PhyTxPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyTxPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group of attributes for dot11PhyTxPowerTable. Implemented as a table indexed on STA ID to allow for multiple instances on an Agent." ::= { dot11phy 3} dot11PhyTxPowerEntry OBJECT-TYPE SYNTAX Dot11PhyTxPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyTxPower Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyTxPowerTable 1 } Dot11PhyTxPowerEntry ::= SEQUENCE { dot11NumberSupportedPowerLevelsImplemented Unsigned32, dot11TxPowerLevel1 Unsigned32, dot11TxPowerLevel2 Unsigned32, dot11TxPowerLevel3 Unsigned32, dot11TxPowerLevel4 Unsigned32, dot11TxPowerLevel5 Unsigned32, dot11TxPowerLevel6 Unsigned32, dot11TxPowerLevel7 Unsigned32, dot11TxPowerLevel8 Unsigned32, dot11CurrentTxPowerLevel Unsigned32, dot11TxPowerLevelExtended OCTET STRING, dot11CurrentTxPowerLevelExtended Unsigned32 } dot11NumberSupportedPowerLevelsImplemented OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The number of power levels supported by the PHY. This attribute can have a value of 1 to 8." ::= { dot11PhyTxPowerEntry 1 } dot11TxPowerLevel1 OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The transmit output power for LEVEL1. This is also the default power level." ::= { dot11PhyTxPowerEntry 2 } dot11TxPowerLevel2 OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The transmit output power for LEVEL2." ::= { dot11PhyTxPowerEntry 3 } dot11TxPowerLevel3 OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The transmit output power for LEVEL3." ::= { dot11PhyTxPowerEntry 4 } dot11TxPowerLevel4 OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The transmit output power for LEVEL4." ::= { dot11PhyTxPowerEntry 5 } dot11TxPowerLevel5 OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The transmit output power for LEVEL5." ::= { dot11PhyTxPowerEntry 6 } dot11TxPowerLevel6 OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The transmit output power for LEVEL6." ::= { dot11PhyTxPowerEntry 7 } dot11TxPowerLevel7 OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The transmit output power for LEVEL7." ::= { dot11PhyTxPowerEntry 8 } dot11TxPowerLevel8 OBJECT-TYPE SYNTAX Unsigned32 (0..10000) UNITS "mW" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The transmit output power for LEVEL8." ::= { dot11PhyTxPowerEntry 9 } dot11CurrentTxPowerLevel OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. Set to min(N,8) where N is an index into dot11TxPowerLevel or dot11TxPowerLevelExtended and identifies the transmit power level currently being used to transmit data. Some PHYs also use this value to determine the receiver sensitivity requirements for CCA." ::= { dot11PhyTxPowerEntry 10 } dot11TxPowerLevelExtended OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2..256)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. It has an even number of octets. It is organized as a variable length list of octet pairs, where each octet pair defines a big-endian 16-bit integer. The N-th integer represents the N-th EIRP, in units of 250 microWatts. The values dot11TxPowerLevel1 to dot11TxPowerLevel inclusive, in order, correspond to the first to min(8, dot11NumberSupportedPowerLevelsImplemented)-th integers in this variable. Where dot11TxPowerLevel1 to dot11TxPowerLevel inclusive contain EIRP values then, when converted from units of milliWatts to 250 microWatts, they shall appear in order in positions 1 to min(8, dot11NumberSupportedPowerLevelsImplemented) in this variable." ::= { dot11PhyTxPowerEntry 11 } dot11CurrentTxPowerLevelExtended OBJECT-TYPE SYNTAX Unsigned32 (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. Contains an index into the integer array in dot11TxPowerLevelExtended (where the value 1 indicates the first value in dot11TxPowerLevelExtended, and so on) that identifies the transmit output power currently being used to transmit data." ::= { dot11PhyTxPowerEntry 12 } -- ********************************************************************** -- * End of dot11PhyTxPower TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PhyDSSSEntry TABLE -- ********************************************************************** dot11PhyDSSSTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyDSSSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyDSSSEntry. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 5 } dot11PhyDSSSEntry OBJECT-TYPE SYNTAX Dot11PhyDSSSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyDSSSEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyDSSSTable 1 } Dot11PhyDSSSEntry ::= SEQUENCE { dot11CurrentChannel Unsigned32, dot11CCAModeSupported Unsigned32, dot11CurrentCCAMode INTEGER, dot11EDThreshold Integer32 } dot11CurrentChannel OBJECT-TYPE SYNTAX Unsigned32 (1..14) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. The current operating frequency channel of the DSSS PHY. Valid channel numbers are as defined in 15.4.4.3" ::= { dot11PhyDSSSEntry 1 } dot11CCAModeSupported OBJECT-TYPE SYNTAX Unsigned32 (1..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. dot11CCAModeSupported is a bit-significant value, representing all of the CCA modes supported by the DSSS PHY in addition to detection of energy above -62 dBm (which is always supported). Valid values are: energy detect only (edonly) = 01, carrier sense only (csonly) = 02, carrier sense and energy detect (csanded)= 04 or the logical sum of any of these values." ::= { dot11PhyDSSSEntry 2 } dot11CurrentCCAMode OBJECT-TYPE SYNTAX INTEGER { edonly(1), csonly(2), csanded(4), cswithtimer(8), hrcsanded(16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The current CCA method in operation for a DSSS or HR/DSSS PHY, in addition to detection of energy above -62 dBm (which is always supported). Valid values are: energy detect only (edonly) = 01, carrier sense only (csonly) = 02, carrier sense and energy detect (csanded)= 04 carrier sense with timer (cswithtimer)= 08 high rate carrier sense and energy detect (hrcsanded)=16, subject to the support indicated in dot11CCAModeSupported (for the DSSS PHY) or dot11HRCCAModeImplemented (for the HR/DSSS PHY)." ::= { dot11PhyDSSSEntry 3 } dot11EDThreshold OBJECT-TYPE SYNTAX Integer32 (-100..-70) UNITS "dBm" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The current energy detect threshold being used by the DSSS PHY or HR/DSSS PHY." ::= { dot11PhyDSSSEntry 4 } -- ********************************************************************** -- * End of dot11PhyDSSSEntry TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11RegDomainsSupported TABLE -- ********************************************************************** dot11RegDomainsSupportedTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RegDomainsSupportedEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Superseded by dot11OperatingClassesTable. There are different operational requirements dependent on the regulatory domain. This attribute list describes the regulatory domains the PHY supports in this implementation. Currently defined values and their corresponding Regulatory Domains are: FCC (USA) = X'10', DOC (Canada) = X'20', ETSI (most of Europe) = X'30', Spain = X'31', France = X'32', Japan = X'40', China = X'50', Other = X'00' " ::= { dot11phy 7} dot11RegDomainsSupportedEntry OBJECT-TYPE SYNTAX Dot11RegDomainsSupportedEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Superseded by dot11OperatingClassesTable. An entry in the dot11RegDomainsSupportedTable. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11RegDomainsSupportedIndex } ::= { dot11RegDomainsSupportedTable 1 } Dot11RegDomainsSupportedEntry ::= SEQUENCE { dot11RegDomainsSupportedIndex Unsigned32, dot11RegDomainsImplementedValue INTEGER } dot11RegDomainsSupportedIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "The auxiliary variable used to identify instances of the columnar objects in the RegDomainsSupport Table." ::= { dot11RegDomainsSupportedEntry 1 } dot11RegDomainsImplementedValue OBJECT-TYPE SYNTAX INTEGER { other (0), fcc(16), doc(32), etsi(48), spain (49), france(50), japan (64)} MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. There are different operational requirements dependent on the regulatory domain. This attribute list describes the regulatory domains the PHY supports in this implementation. Currently defined values and their corresponding Regulatory Domains are: FCC (USA) = X'10', DOC (Canada) = X'20', ETSI (most of Europe) = X'30', Spain = X'31', France = X'32', Japan = X'40', China = X'50' " ::= { dot11RegDomainsSupportedEntry 2 } -- ********************************************************************** -- * End of dot11RegDomainsSupported TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11AntennasList TABLE -- ********************************************************************** dot11AntennasListTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11AntennasListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table represents the list of antennae. An antenna can be marked to be capable of transmitting, receiving, and/or for participation in receive diversity. Each entry in this table represents a single antenna with its properties. The maximum number of antennae that can be contained in this table is 255." ::= { dot11phy 8 } dot11AntennasListEntry OBJECT-TYPE SYNTAX Dot11AntennasListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11AntennasListTable, representing the properties of a single antenna. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11AntennaListIndex } ::= { dot11AntennasListTable 1 } Dot11AntennasListEntry ::= SEQUENCE { dot11AntennaListIndex Unsigned32, dot11TxAntennaImplemented TruthValue, dot11RxAntennaImplemented TruthValue, dot11DiversitySelectionRxImplemented TruthValue } dot11AntennaListIndex OBJECT-TYPE SYNTAX Unsigned32 (1..254) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The unique index of an antenna which is used to identify the columnar objects in the dot11AntennasList Table." ::= { dot11AntennasListEntry 1 } dot11TxAntennaImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. When true, this object indicates that the antenna represented by dot11AntennaListIndex can be used as a transmit antenna." ::= { dot11AntennasListEntry 2 } dot11RxAntennaImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. When true, this object indicates that the antenna represented by the dot11AntennaListIndex can be used as a receive antenna." ::= { dot11AntennasListEntry 3 } dot11DiversitySelectionRxImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. When true, this object indicates that the antenna represented by dot11AntennaListIndex can be used for receive diversity. This object is true only if the antenna can be used as a receive antenna, as indicated by dot11RxAntennaImplemented." ::= { dot11AntennasListEntry 4 } -- ********************************************************************** -- * End of dot11AntennasList TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11SupportedDataRatesTx TABLE -- ********************************************************************** dot11SupportedDataRatesTxTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11SupportedDataRatesTxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Transmit bit rates supported by the PHY, represented by a count from X'02-X'7f, corresponding to data rates in increments of 500 kb/s from 1 Mb/s to 63.5 Mb/s subject to limitations of each individual PHY." ::= { dot11phy 9 } dot11SupportedDataRatesTxEntry OBJECT-TYPE SYNTAX Dot11SupportedDataRatesTxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the dot11SupportedDataRatesTx Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11SupportedDataRatesTxIndex } ::= { dot11SupportedDataRatesTxTable 1 } Dot11SupportedDataRatesTxEntry ::= SEQUENCE { dot11SupportedDataRatesTxIndex Unsigned32, dot11ImplementedDataRatesTxValue Unsigned32 } dot11SupportedDataRatesTxIndex OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index object that identifies which data rate to access. Range is 1..255." ::= { dot11SupportedDataRatesTxEntry 1 } dot11ImplementedDataRatesTxValue OBJECT-TYPE SYNTAX Unsigned32 (2..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The Transmit bit rates supported by the PHY, represented by a count from X'02-X'7f, corresponding to data rates in increments of 500 kb/s from 1 Mb/s to 63.5 Mb/s subject to limitations of each individual PHY." ::= { dot11SupportedDataRatesTxEntry 2 } -- ********************************************************************** -- * End of dot11SupportedDataRatesTx TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11SupportedDataRatesRx TABLE -- ********************************************************************** dot11SupportedDataRatesRxTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11SupportedDataRatesRxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The receive bit rates supported by the PHY, represented by a count from X'002-X'7f, corresponding to data rates in increments of 500 kb/s from 1 Mb/s to 63.5 Mb/s." ::= { dot11phy 10 } dot11SupportedDataRatesRxEntry OBJECT-TYPE SYNTAX Dot11SupportedDataRatesRxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the dot11SupportedDataRatesRx Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11SupportedDataRatesRxIndex } ::= { dot11SupportedDataRatesRxTable 1 } Dot11SupportedDataRatesRxEntry ::= SEQUENCE { dot11SupportedDataRatesRxIndex Unsigned32, dot11ImplementedDataRatesRxValue Unsigned32 } dot11SupportedDataRatesRxIndex OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index object that identifies which data rate to access. Range is 1..255." ::= { dot11SupportedDataRatesRxEntry 1 } dot11ImplementedDataRatesRxValue OBJECT-TYPE SYNTAX Unsigned32 (2..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The receive bit rates supported by the PHY, represented by a count from X'02-X'7f, corresponding to data rates in increments of 500 kb/s from 1 Mb/s to 63.5 Mb/s." ::= { dot11SupportedDataRatesRxEntry 2 } -- ********************************************************************** -- * End of dot11SupportedDataRatesRx TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PhyOFDM TABLE -- ********************************************************************** dot11PhyOFDMTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyOFDMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group of attributes for dot11PhyOFDMTable. Implemented as a table indexed on ifindex to allow for multiple instances on an Agent." ::= { dot11phy 11 } dot11PhyOFDMEntry OBJECT-TYPE SYNTAX Dot11PhyOFDMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyOFDM Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyOFDMTable 1 } Dot11PhyOFDMEntry ::= SEQUENCE { dot11CurrentFrequency Unsigned32, dot11TIThreshold Integer32, dot11FrequencyBandsImplemented Unsigned32, dot11ChannelStartingFactor Unsigned32, dot11FiveMHzOperationImplemented TruthValue, dot11TenMHzOperationImplemented TruthValue, dot11TwentyMHzOperationImplemented TruthValue, dot11PhyOFDMChannelWidth INTEGER, dot11OFDMCCAEDImplemented TruthValue, dot11OFDMCCAEDRequired TruthValue, dot11OFDMEDThreshold Unsigned32, dot11STATransmitPowerClass INTEGER, dot11ACRType INTEGER } dot11CurrentFrequency OBJECT-TYPE SYNTAX Unsigned32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. The number of the current operating frequency channel of the OFDM PHY." ::= { dot11PhyOFDMEntry 1 } dot11TIThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Superseded by PHY-specific or regulatory CCA energy detect limits. The Threshold being used to detect a busy medium (frequency). CCA reports a busy medium upon detecting the RSSI above this threshold." ::= { dot11PhyOFDMEntry 2 } dot11FrequencyBandsImplemented OBJECT-TYPE SYNTAX Unsigned32 (1..127) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Superseded by subband-specific supported operating classes. This is a capability variable. Its value is determined by device capabilities. The capability of the OFDM PHY implementation to operate in the 4.9 GHz and 5 GHz bands. Coded as an integer value with bit 0 LSB as follows: bit 0 .. capable of operating in the 5.15-5.25 GHz band bit 1 .. capable of operating in the 5.25-5.35 GHz band bit 2 .. capable of operating in the 5.725-5.825 GHz band bit 3 .. capable of operating in the 5.47-5.725 GHz band bit 4 .. capable of operating in the lower Japanese (5.15-5.25 GHz) band bit 5 .. capable of operating in the 5.03-5.091 GHz band bit 6 .. capable of operating in the 4.94-4.99 GHz band For example, for an implementation capable of operating in the 5.15-5.35 GHz bands this attribute would take the value 3." ::= { dot11PhyOFDMEntry 3 } dot11ChannelStartingFactor OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The base factor from which channel center frequencies are calculated. This number is multiplied by 500 kHz to form the base frequency to be added to the channel number x 5 MHz." DEFVAL { 10000 } ::= { dot11PhyOFDMEntry 4 } dot11FiveMHzOperationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the 5 MHz Operation is implemented." ::= { dot11PhyOFDMEntry 5 } dot11TenMHzOperationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the 10 MHz Operation is implemented." ::= { dot11PhyOFDMEntry 6 } dot11TwentyMHzOperationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the 20 MHz Operation is implemented." ::= { dot11PhyOFDMEntry 7 } dot11PhyOFDMChannelWidth OBJECT-TYPE SYNTAX INTEGER { width5MHz(1), width10MHz(2), width20MHz(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME. Changes take effect as soon as practical in the implementation. This is an 8-bit integer value that identifies the OFDM PHY channel width. Currently defined values and their corresponding Channel widths are: 5 MHz = 01, 10 MHz = 02, 20 MHz = 03" ::= { dot11PhyOFDMEntry 8 } dot11OFDMCCAEDImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates that the OFDM PHY is capable of CCA-Energy Detect." ::= { dot11PhyOFDMEntry 9 } dot11OFDMCCAEDRequired OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a control variable. It is written by the SME when the device is initialized for operation in a band defined by an Operating Class. This attribute indicates that the PHY CCA-Energy Detect functionality is enabled." ::= { dot11PhyOFDMEntry 10 } dot11OFDMEDThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written the SME when the device is initialized for operation in a band defined by an Operating Class, or written by an external management entity. Changes take effect as soon as practical in the implementation. The current Energy Detect Threshold being used by the OFDM PHY." ::= { dot11PhyOFDMEntry 11 } dot11STATransmitPowerClass OBJECT-TYPE SYNTAX INTEGER { classA(1), classB(2), classC(3), classD(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The station transmit power class: Class A=1, Class B=2, Class C=3, Class D=4 (as defined in D.2.2)." ::= { dot11PhyOFDMEntry 12 } dot11ACRType OBJECT-TYPE SYNTAX INTEGER { standard(1), enhanced(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME. The Adjacent and Nonadjacent Channel Rejection performance: when this attribute = 1 the levels in Table 17-18 apply; when this attribute = 2 the levels in Table 17-19 apply." DEFVAL { 1 } ::= { dot11PhyOFDMEntry 13 } -- ********************************************************************** -- * End of dot11PhyOFDM TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PhyHRDSSSEntry TABLE -- ********************************************************************** dot11PhyHRDSSSTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyHRDSSSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyHRDSSSEntry. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 12 } dot11PhyHRDSSSEntry OBJECT-TYPE SYNTAX Dot11PhyHRDSSSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyHRDSSSEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11PhyHRDSSSTable 1 } Dot11PhyHRDSSSEntry ::= SEQUENCE { dot11ShortPreambleOptionImplemented TruthValue, dot11HRCCAModeImplemented Unsigned32 } dot11ShortPreambleOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the short preamble option as defined in 16.2.2.3 is implemented." ::= { dot11PhyHRDSSSEntry 1 } dot11HRCCAModeImplemented OBJECT-TYPE SYNTAX Unsigned32 (1..31) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. dot11HRCCAModeImplemented is a bit-significant value, representing all of the CCA modes supported by the HR/DSSS PHY, in addition to detection of energy above -62 dBm (which is always supported). Valid values are: energy detect only (edonly) = 01, carrier sense with timer (cswithtimer)= 08, high rate carrier sense and energy detect (hrcsanded)= 16 or the logical sum of any of these values." ::= { dot11PhyHRDSSSEntry 5 } -- ********************************************************************** -- * End of dot11PhyHRDSSSEntry TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11HoppingPattern TABLE -- ********************************************************************** dot11HoppingPatternTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11HoppingPatternEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This attribute is deprecated because the frequency hopping PHY is no longer present in IEEE Std 802.11. The (conceptual) table of attributes necessary for a frequency hopping implementation to be able to create the hopping sequences necessary to operate in the subband for the associated domain country string." ::= { dot11phy 13 } dot11HoppingPatternEntry OBJECT-TYPE SYNTAX Dot11HoppingPatternEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This attribute is deprecated because the frequency hopping PHY is no longer present in IEEE Std 802.11. An entry (conceptual row) in the Hopping Pattern Table that indicates the random hopping sequence to be followed. IfIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB are indexed by ifIndex." INDEX { ifIndex, dot11HoppingPatternIndex } ::= { dot11HoppingPatternTable 1 } Dot11HoppingPatternEntry ::= SEQUENCE { dot11HoppingPatternIndex Unsigned32, dot11RandomTableFieldNumber Unsigned32 } dot11HoppingPatternIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This attribute is deprecated because the frequency hopping PHY is no longer present in IEEE Std 802.11. The auxiliary variable used to identify instances of the columnar objects in the Hopping Pattern Table." ::= { dot11HoppingPatternEntry 1 } dot11RandomTableFieldNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This attribute is deprecated because the frequency hopping PHY is no longer present in IEEE Std 802.11. This is a control variable. It is written by the SME when the device is initialized. This attribute indicates the value of the starting channel number in the hopping sequence of the subband for the associated domain country string." DEFVAL { 0 } ::= { dot11HoppingPatternEntry 2 } -- ********************************************************************** -- * End of dot11HoppingPattern TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11PhyERP TABLE -- ********************************************************************** dot11PhyERPTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyERPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyERPEntry. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 14 } dot11PhyERPEntry OBJECT-TYPE SYNTAX Dot11PhyERPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyERPEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11PhyERPTable 1 } Dot11PhyERPEntry ::= SEQUENCE { dot11ShortSlotTimeOptionImplemented TruthValue, dot11ShortSlotTimeOptionActivated TruthValue, dot11Class2CapabilitiesOptionImplemented TruthValue} dot11ShortSlotTimeOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that short slot time as defined in 9.4.1.4 is implemented." ::= { dot11PhyERPEntry 5} dot11ShortSlotTimeOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that short slot time as defined in 9.4.1.4 is enabled." DEFVAL { false } ::= { dot11PhyERPEntry 6 } dot11Class2CapabilitiesOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the station is a Class 2 ERP or Class 2 HT STA. This attribute is false if the STA is not operating in the 2.4 GHz band." ::= { dot11PhyERPEntry 7 } -- ********************************************************************** -- * End of dot11PhyERP TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11 Phy HT TABLE -- ********************************************************************** dot11PhyHTTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyHTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyHTTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 15 } dot11PhyHTEntry OBJECT-TYPE SYNTAX Dot11PhyHTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyHTEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11PhyHTTable 1 } Dot11PhyHTEntry ::= SEQUENCE { dot11FortyMHzOperationImplemented TruthValue, dot11FortyMHzOperationActivated TruthValue, dot11CurrentPrimaryChannel Unsigned32, dot11CurrentSecondaryChannel Unsigned32, dot11NumberOfSpatialStreamsImplemented Unsigned32, dot11NumberOfSpatialStreamsActivated Unsigned32, dot11HTGreenfieldOptionImplemented TruthValue, dot11HTGreenfieldOptionActivated TruthValue, dot11ShortGIOptionInTwentyImplemented TruthValue, dot11ShortGIOptionInTwentyActivated TruthValue, dot11ShortGIOptionInFortyImplemented TruthValue, dot11ShortGIOptionInFortyActivated TruthValue, dot11LDPCCodingOptionImplemented TruthValue, dot11LDPCCodingOptionActivated TruthValue, dot11TxSTBCOptionImplemented TruthValue, dot11TxSTBCOptionActivated TruthValue, dot11RxSTBCOptionImplemented TruthValue, dot11RxSTBCOptionActivated TruthValue, dot11BeamFormingOptionImplemented TruthValue, dot11BeamFormingOptionActivated TruthValue, dot11HighestSupportedDataRate Unsigned32, dot11TxMCSSetDefined TruthValue, dot11TxRxMCSSetNotEqual TruthValue, dot11TxMaximumNumberSpatialStreamsSupported Unsigned32, dot11TxUnequalModulationSupported TruthValue } dot11FortyMHzOperationImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the 40 MHz Operation is implemented." ::= { dot11PhyHTEntry 1 } dot11FortyMHzOperationActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the 40 MHz Operation is enabled." DEFVAL { false } ::= { dot11PhyHTEntry 2 } dot11CurrentPrimaryChannel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. This attribute indicates the operating channel. If 20/40 MHz BSS is currently in use then this attribute indicates the primary channel." ::= { dot11PhyHTEntry 3 } dot11CurrentSecondaryChannel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. This attribute indicates the channel number of the secondary channel. If 20/40 MHz BSS is not currently in use, this attribute value shall be 0." ::= { dot11PhyHTEntry 4 } dot11NumberOfSpatialStreamsImplemented OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of spatial streams implemented." ::= { dot11PhyHTEntry 5 } dot11NumberOfSpatialStreamsActivated OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum number of spatial streams enabled." DEFVAL { 2 } ::= { dot11PhyHTEntry 6 } dot11HTGreenfieldOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the HT-greenfield option is implemented." ::= { dot11PhyHTEntry 7 } dot11HTGreenfieldOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the HT-greenfield option is enabled." DEFVAL { false } ::= { dot11PhyHTEntry 8 } dot11ShortGIOptionInTwentyImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the Short Guard option is implemented for 20 MHz operation." ::= { dot11PhyHTEntry 9 } dot11ShortGIOptionInTwentyActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the Short Guard option is enabled for 20 MHz operation." DEFVAL { false } ::= { dot11PhyHTEntry 10 } dot11ShortGIOptionInFortyImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the Short Guard option is implemented for 40 MHz operation." ::= { dot11PhyHTEntry 11 } dot11ShortGIOptionInFortyActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the Short Guard option is enabled for 40 MHz operation." DEFVAL { false } ::= { dot11PhyHTEntry 12 } dot11LDPCCodingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the LDPC coding option is implemented." ::= { dot11PhyHTEntry 13 } dot11LDPCCodingOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the LDPC coding option is enabled." DEFVAL { false } ::= { dot11PhyHTEntry 14 } dot11TxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the entity is capable of transmitting frames using STBC option." ::= { dot11PhyHTEntry 15 } dot11TxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the entity's capability of transmitting frames using STBC option is enabled." DEFVAL { false } ::= { dot11PhyHTEntry 16 } dot11RxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the entity is capable of receiving frames that are sent using the STBC." ::= { dot11PhyHTEntry 17 } dot11RxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the entity's capability of receiving frames that are sent using the STBC is enabled." DEFVAL { false } ::= { dot11PhyHTEntry 18 } dot11BeamFormingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the beamforming option is implemented." ::= { dot11PhyHTEntry 19 } dot11BeamFormingOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the beamforming option is enabled." DEFVAL { false } ::= { dot11PhyHTEntry 20 } dot11HighestSupportedDataRate OBJECT-TYPE SYNTAX Unsigned32 (0..600) UNITS "Mb/s" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute shall specify the Highest Data Rate at which the station may receive data." ::= { dot11PhyHTEntry 21 } dot11TxMCSSetDefined OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the Tx MCS set is defined." DEFVAL { false } ::= { dot11PhyHTEntry 22 } dot11TxRxMCSSetNotEqual OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. This attribute, when true, indicates that the supported Tx and Rx MCS sets are not equal." DEFVAL { false } ::= { dot11PhyHTEntry 23 } dot11TxMaximumNumberSpatialStreamsSupported OBJECT-TYPE SYNTAX Unsigned32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the Tx maximum number of spatial streams supported." ::= { dot11PhyHTEntry 24 } dot11TxUnequalModulationSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that Tx UEQM is supported." ::= { dot11PhyHTEntry 25 } -- ********************************************************************** -- * End of dot11 PHY HT TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11 Supported MCS Tx TABLE -- ********************************************************************** dot11SupportedHTMCSTxTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11SupportedHTMCSTxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "he Transmit MCS supported by the PHY, represented by a count from 1 to 127, subject to limitations of each individual PHY." ::= { dot11phy 16 } dot11SupportedHTMCSTxEntry OBJECT-TYPE SYNTAX Dot11SupportedHTMCSTxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the dot11SupportedHTMCSTx Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11SupportedHTMCSTxIndex } ::= { dot11SupportedHTMCSTxTable 1 } Dot11SupportedHTMCSTxEntry ::= SEQUENCE { dot11SupportedHTMCSTxIndex Unsigned32, dot11SupportedHTMCSTxValue Unsigned32 } dot11SupportedHTMCSTxIndex OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index object that identifies which MCS to access. Range is 1..255." ::= { dot11SupportedHTMCSTxEntry 1 } dot11SupportedHTMCSTxValue OBJECT-TYPE SYNTAX Unsigned32 (1..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The Transmit MCS supported by the PHY, represented by a count from 1 to 127, subject to limitations of each individual PHY." ::= { dot11SupportedHTMCSTxEntry 2 } -- ********************************************************************** -- * End of dot11 Supported MCS Tx TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11 Supported MCS Rx TABLE -- ********************************************************************** dot11SupportedHTMCSRxTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11SupportedHTMCSRxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The receive MCS supported by the PHY, represented by a count from 1 to 127, subject to limitations of each individual PHY." ::= { dot11phy 17 } dot11SupportedHTMCSRxEntry OBJECT-TYPE SYNTAX Dot11SupportedHTMCSRxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry (conceptual row) in the dot11SupportedHTMCSRx Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex, dot11SupportedHTMCSRxIndex } ::= { dot11SupportedHTMCSRxTable 1 } Dot11SupportedHTMCSRxEntry ::= SEQUENCE { dot11SupportedHTMCSRxIndex Unsigned32, dot11SupportedHTMCSRxValue Unsigned32 } dot11SupportedHTMCSRxIndex OBJECT-TYPE SYNTAX Unsigned32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index object that identifies which MCS to access. Range is 1..255." ::= { dot11SupportedHTMCSRxEntry 1 } dot11SupportedHTMCSRxValue OBJECT-TYPE SYNTAX Unsigned32 (1..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. The receive MCS supported by the PHY, represented by a count from 1 to 127, subject to limitations of each individual PHY." ::= { dot11SupportedHTMCSRxEntry 2 } -- ********************************************************************** -- * End of dot11 Supported MCS Rx TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11 Transmit Beamforming Config TABLE -- ********************************************************************** dot11TransmitBeamformingConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11TransmitBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11TransmitBeamformingConfigTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 18 } dot11TransmitBeamformingConfigEntry OBJECT-TYPE SYNTAX Dot11TransmitBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11TransmitBeamformingConfig Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11TransmitBeamformingConfigTable 1 } Dot11TransmitBeamformingConfigEntry ::= SEQUENCE { dot11ReceiveStaggerSoundingOptionImplemented TruthValue, dot11TransmitStaggerSoundingOptionImplemented TruthValue, dot11ReceiveNDPOptionImplemented TruthValue, dot11TransmitNDPOptionImplemented TruthValue, dot11ImplicitTransmitBeamformingOptionImplemented TruthValue, dot11CalibrationOptionImplemented INTEGER, dot11ExplicitCSITransmitBeamformingOptionImplemented TruthValue, dot11ExplicitNonCompressedBeamformingMatrixOptionImplemented TruthValue, dot11ExplicitTransmitBeamformingCSIFeedbackOptionImplemented INTEGER, dot11ExplicitNonCompressedBeamformingFeedbackOptionImplemented INTEGER, dot11ExplicitCompressedBeamformingFeedbackOptionImplemented INTEGER, dot11NumberBeamFormingCSISupportAntenna Unsigned32, dot11NumberNonCompressedBeamformingMatrixSupportAntenna Unsigned32, dot11NumberCompressedBeamformingMatrixSupportAntenna Unsigned32 } dot11ReceiveStaggerSoundingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation supports the receiving of staggered sounding frames." ::= { dot11TransmitBeamformingConfigEntry 1 } dot11TransmitStaggerSoundingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation supports the transmission of staggered sounding frames." ::= { dot11TransmitBeamformingConfigEntry 2 } dot11ReceiveNDPOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of receiving NDP as sounding frames." ::= { dot11TransmitBeamformingConfigEntry 3 } dot11TransmitNDPOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA implementation is capable of transmitting NDP as sounding frames." ::= { dot11TransmitBeamformingConfigEntry 4 } dot11ImplicitTransmitBeamformingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that STA implementation is capable of applying implicit transmit beamforming." ::= { dot11TransmitBeamformingConfigEntry 5 } dot11CalibrationOptionImplemented OBJECT-TYPE SYNTAX INTEGER { inCapable (0), unableToInitiate (1), ableToInitiate (2), fullyCapable (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the level of calibration supported by the STA implementation." ::= { dot11TransmitBeamformingConfigEntry 6 } dot11ExplicitCSITransmitBeamformingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that STA implementation is capable of applying transmit beamforming using CSI explicit feedback in its transmission." ::= { dot11TransmitBeamformingConfigEntry 7 } dot11ExplicitNonCompressedBeamformingMatrixOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that STA implementation is capable of applying transmit beamforming using noncompressed beamforming feedback matrix explicit feedback in its transmission." ::= { dot11TransmitBeamformingConfigEntry 8 } dot11ExplicitTransmitBeamformingCSIFeedbackOptionImplemented OBJECT-TYPE SYNTAX INTEGER { inCapable (0), delayed (1), immediate (2), unsolicitedImmediate (3), aggregated (4), delayedAggregated (5), immediateAggregated(6), unsolicitedImmediateAggregated (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the level of CSI explicit feedback returned by the STA implementation." ::= { dot11TransmitBeamformingConfigEntry 9 } dot11ExplicitNonCompressedBeamformingFeedbackOptionImplemented OBJECT-TYPE SYNTAX INTEGER { inCapable (0), delayed (1), immediate (2), unsolicitedImmediate (3), aggregated (4), delayedAggregated (5), immediateAggregated(6), unsolicitedImmediateAggregated (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the level of noncompressed beamforming feedback matrix explicit feedback returned by the STA implementation." ::= { dot11TransmitBeamformingConfigEntry 10 } dot11ExplicitCompressedBeamformingFeedbackOptionImplemented OBJECT-TYPE SYNTAX INTEGER { inCapable (0), delayed (1), immediate (2), unsolicitedImmediate (3), aggregated (4), delayedAggregated (5), immediateAggregated(6), unsolicitedImmediateAggregated (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the level of noncompressed beamforming feedback matrix explicit feedback returned by the STA implementation." ::= { dot11TransmitBeamformingConfigEntry 11 } dot11NumberBeamFormingCSISupportAntenna OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of beamforming antennas the beamformee can support when CSI feedback is required." ::= { dot11TransmitBeamformingConfigEntry 12 } dot11NumberNonCompressedBeamformingMatrixSupportAntenna OBJECT-TYPE SYNTAX Unsigned32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of beamforming antennas the beamformee can support when noncompressed beamforming feedback matrix feedback is required." ::= { dot11TransmitBeamformingConfigEntry 13 } dot11NumberCompressedBeamformingMatrixSupportAntenna OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of beamforming antennas the beamformee can support when compressed beamforming feedback matrix feedback is required." ::= { dot11TransmitBeamformingConfigEntry 14 } -- ********************************************************************** -- * End of dot11 Transmit Beamforming Config TABLE -- ********************************************************************** -- ******************************************************************* -- * dot11 Phy DMG TABLE -- ******************************************************************* dot11PHYDMGTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PHYDMGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyDMGTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 19 } dot11PHYDMGEntry OBJECT-TYPE SYNTAX Dot11PHYDMGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in dot11PHYDMGTable. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11PHYDMGTable 1 } Dot11PHYDMGEntry ::= SEQUENCE { dot11LowPowerSCPHYImplemented TruthValue, dot11LowPowerSCPHYActivated TruthValue } dot11LowPowerSCPHYImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the low power SC mode is implemented." ::= { dot11PHYDMGEntry 1 } dot11LowPowerSCPHYActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the low power SC mode is activated." DEFVAL { false } ::= { dot11PHYDMGEntry 2 } -- ******************************************************************* -- * End of dot11 PHY DMG TABLE -- ******************************************************************* -- ******************************************************************* -- * dot11DMGBeamformingConfig TABLE -- ******************************************************************* dot11DMGBeamformingConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11DMGBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a Table management object. The dot11DMGBeamformingConfig Table" ::= { dot11phy 22 } dot11DMGBeamformingConfigEntry OBJECT-TYPE SYNTAX Dot11DMGBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry in the dot11DMGBeamformingConfigTable Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX { ifIndex } ::= { dot11DMGBeamformingConfigTable 1 } Dot11DMGBeamformingConfigEntry ::= SEQUENCE { dot11MaxBFTime Unsigned32, dot11BFTXSSTime Unsigned32, dot11MaximalSectorScan Unsigned32, dot11ABFTRTXSSSwitch Unsigned32, dot11RSSRetryLimit Unsigned32, dot11RSSBackoff Unsigned32, dot11BFRetryLimit Unsigned32, dot11BeamLinkMaintenanceTime Unsigned32, dot11AntennaSwitchingTime Unsigned32, dot11ChanMeasFBCKNtaps Unsigned32, dot11BeamTrackingTimeLimit Unsigned32 } dot11MaxBFTime OBJECT-TYPE SYNTAX Unsigned32 (1..16) UNITS "beacon intervals" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Maximum Beamforming Time." DEFVAL { 4 } ::= { dot11DMGBeamformingConfigEntry 1 } dot11BFTXSSTime OBJECT-TYPE SYNTAX Unsigned32 (1..256) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Timeout until the initiator restarts ISS." DEFVAL { 100 } ::= { dot11DMGBeamformingConfigEntry 2 } dot11MaximalSectorScan OBJECT-TYPE SYNTAX Unsigned32 (1..32) UNITS "beacon intervals" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Maximal Sector Scan." DEFVAL { 8 } ::= { dot11DMGBeamformingConfigEntry 3 } dot11ABFTRTXSSSwitch OBJECT-TYPE SYNTAX Unsigned32 (1..32) UNITS "beacon intervals" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. A-BFT Transmit Sector Sweep Switch." DEFVAL { 4 } ::= { dot11DMGBeamformingConfigEntry 4 } dot11RSSRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Responder Sector Sweep Retry Limit" DEFVAL { 8 } ::= { dot11DMGBeamformingConfigEntry 5 } dot11RSSBackoff OBJECT-TYPE SYNTAX Unsigned32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Responder Sector Sweep Backoff" DEFVAL { 8 } ::= { dot11DMGBeamformingConfigEntry 6 } dot11BFRetryLimit OBJECT-TYPE SYNTAX Unsigned32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME or an external management entity. Changes take effect as soon as practical in the implementation. Beamforming Retry Limit" DEFVAL { 8 } ::= { dot11DMGBeamformingConfigEntry 7 } dot11BeamLinkMaintenanceTime OBJECT-TYPE SYNTAX Unsigned32 (0..64000000) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC or SME. Changes take effect as soon as practical in the implementation. Beam Link Maintenance Time dot11BeamLinkMaintenanceTime = BeamLink_Maintenance_Unit * BeamLink_Maintenance_Value. Otherwise, the dot11BeamLinkMaintenanceTime is left undefined. An undefined value of the dot11BeamLinkMaintenanceTime indicates that the STA does not participate in beamformed link maintenance." DEFVAL { 0 } ::= { dot11DMGBeamformingConfigEntry 8 } dot11AntennaSwitchingTime OBJECT-TYPE SYNTAX Unsigned32 (0..64000000) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC or SME. Changes take effect as soon as practical in the implementation." DEFVAL { 0 } ::= { dot11DMGBeamformingConfigEntry 9 } dot11ChanMeasFBCKNtaps OBJECT-TYPE SYNTAX Unsigned32 (0..64000000) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC or SME. Changes take effect as soon as practical in the implementation. Number of channel measurement taps." DEFVAL { 0 } ::= { dot11DMGBeamformingConfigEntry 10 } dot11BeamTrackingTimeLimit OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the MAC or SME. Changes take effect as soon as practical in the implementation. BRP tracking initiator time limit." DEFVAL { 10000 } ::= { dot11DMGBeamformingConfigEntry 11 } -- ******************************************************************* -- * End of dot11DMGBeamformingConfig TABLE -- ******************************************************************* -- ********************************************************************** -- * dot11 Phy VHT TABLE -- ********************************************************************** dot11PhyVHTTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyVHTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyVHTTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 23 } dot11PhyVHTEntry OBJECT-TYPE SYNTAX Dot11PhyVHTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyHTEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11PhyVHTTable 1 } Dot11PhyVHTEntry ::= SEQUENCE { dot11VHTChannelWidthOptionImplemented INTEGER, dot11CurrentChannelWidth INTEGER, dot11CurrentChannelCenterFrequencyIndex0 Unsigned32, dot11CurrentChannelCenterFrequencyIndex1 Unsigned32, dot11VHTShortGIOptionIn80Implemented TruthValue, dot11VHTShortGIOptionIn80Activated TruthValue, dot11VHTShortGIOptionIn160and80p80Implemented TruthValue, dot11VHTShortGIOptionIn160and80p80Activated TruthValue, dot11VHTLDPCCodingOptionImplemented TruthValue, dot11VHTLDPCCodingOptionActivated TruthValue, dot11VHTTxSTBCOptionImplemented TruthValue, dot11VHTTxSTBCOptionActivated TruthValue, dot11VHTRxSTBCOptionImplemented TruthValue, dot11VHTRxSTBCOptionActivated TruthValue, dot11VHTMUMaxUsersImplemented Unsigned32, dot11VHTMUMaxNSTSPerUserImplemented Unsigned32, dot11VHTMUMaxNSTSTotalImplemented Unsigned32, dot11VHTMaxNTxChainsImplemented Unsigned32, dot11VHTMaxNTxChainsActivated Unsigned32 } dot11VHTChannelWidthOptionImplemented OBJECT-TYPE SYNTAX INTEGER { contiguous80(0), contiguous160(1), noncontiguous80plus80(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the channel widths supported: 20/40/80 MHz, 20/40/80/160 MHz or 20/40/80/160/80+80 MHz." ::= { dot11PhyVHTEntry 1 } dot11CurrentChannelWidth OBJECT-TYPE SYNTAX INTEGER { cbw20(0), cbw40(1), cbw80(2), cbw160(3), cbw80p80(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. Written by the PHY. This attribute indicates the operating channel width." DEFVAL { cbw20 } ::= { dot11PhyVHTEntry 2 } dot11CurrentChannelCenterFrequencyIndex0 OBJECT-TYPE SYNTAX Unsigned32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. Written by the PHY. For a 20 MHz, 40 MHz, 80 MHz, or 160 MHz channel, denotes the channel center frequency. For an 80+80 MHz channel, denotes the center frequency of frequency segment 0. See 21.3.14." DEFVAL { 0 } ::= { dot11PhyVHTEntry 3 } dot11CurrentChannelCenterFrequencyIndex1 OBJECT-TYPE SYNTAX Unsigned32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. Written by the PHY. For an 80+80 MHz channel, denotes the center frequency of frequency segment 1. Set to 0 for a 20 MHz, 40 MHz, 80 MHz, or 160 MHz channel. See 21.3.14." DEFVAL { 0 } ::= { dot11PhyVHTEntry 4 } dot11VHTShortGIOptionIn80Implemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving 80 MHz short guard interval packets." ::= { dot11PhyVHTEntry 5 } dot11VHTShortGIOptionIn80Activated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the reception of 80 MHz short guard interval packets is enabled." DEFVAL { false } ::= { dot11PhyVHTEntry 6 } dot11VHTShortGIOptionIn160and80p80Implemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving 160 MHz and 80+80 MHz short guard interval packets." ::= { dot11PhyVHTEntry 7 } dot11VHTShortGIOptionIn160and80p80Activated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the reception of 160 MHz and 80+80 MHz short guard interval packets is enabled." DEFVAL { false } ::= { dot11PhyVHTEntry 8 } dot11VHTLDPCCodingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the LDPC coding option for VHT packets is implemented." ::= { dot11PhyVHTEntry 9 } dot11VHTLDPCCodingOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the LDPC coding option for VHT packets is enabled." DEFVAL { false } ::= { dot11PhyVHTEntry 10 } dot11VHTTxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of transmitting VHT PPDUs using STBC." ::= { dot11PhyVHTEntry 11 } dot11VHTTxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the entity's capability for transmitting VHT PPDUs using STBC is enabled." DEFVAL { false } ::= { dot11PhyVHTEntry 12 } dot11VHTRxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving VHT PPDUs using STBC." ::= { dot11PhyVHTEntry 13 } dot11VHTRxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the entity's capability for receiving VHT PPDUs using STBC is enabled." DEFVAL { false } ::= { dot11PhyVHTEntry 14 } dot11VHTMUMaxUsersImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of users to which this device is capable of transmitting within a VHT MU PPDU." ::= { dot11PhyVHTEntry 15 } dot11VHTMUMaxNSTSPerUserImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of space-time streams per user that this device is capable of transmitting within a VHT MU PPDU." ::= { dot11PhyVHTEntry 16 } dot11VHTMUMaxNSTSTotalImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of space-time streams for all users that this device is capable of transmitting within a VHT MU PPDU." ::= { dot11PhyVHTEntry 17 } dot11VHTMaxNTxChainsImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of transmit chains within this device." ::= { dot11PhyVHTEntry 18 } dot11VHTMaxNTxChainsActivated OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum number of transmit chains that are activated within this device, unless this attribute exceeds dot11VHTMaxNTxChainsImplemented, in which case the maximum number of transmit chains that are activated within this device is equal to dot11VHTMaxNTxChainsImplemented." DEFVAL { 2147483647} ::= { dot11PhyVHTEntry 19 } -- ********************************************************************** -- * End of dot11PhyVHT TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11 VHT Transmit Beamforming Config TABLE -- ********************************************************************** dot11VHTTransmitBeamformingConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11VHTTransmitBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11VHTTransmitBeamformingConfigTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 24 } dot11VHTTransmitBeamformingConfigEntry OBJECT-TYPE SYNTAX Dot11VHTTransmitBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11VHTTransmitBeamformingConfig Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11VHTTransmitBeamformingConfigTable 1 } Dot11VHTTransmitBeamformingConfigEntry ::= SEQUENCE { dot11VHTSUBeamformeeOptionImplemented TruthValue, dot11VHTSUBeamformerOptionImplemented TruthValue, dot11VHTMUBeamformeeOptionImplemented TruthValue, dot11VHTMUBeamformerOptionImplemented TruthValue, dot11VHTNumberSoundingDimensions Unsigned32, dot11VHTBeamformeeNTxSupport Unsigned32 } dot11VHTSUBeamformeeOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the SU Beamformee role." ::= { dot11VHTTransmitBeamformingConfigEntry 1 } dot11VHTSUBeamformerOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the SU Beamformer role." ::= { dot11VHTTransmitBeamformingConfigEntry 2 } dot11VHTMUBeamformeeOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the MU Beamformee role." ::= { dot11VHTTransmitBeamformingConfigEntry 3 } dot11VHTMUBeamformerOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the MU Beamformer role." ::= { dot11VHTTransmitBeamformingConfigEntry 4 } dot11VHTNumberSoundingDimensions OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the number of antennas used by the beamformer when sending beamformed transmissions." ::= { dot11VHTTransmitBeamformingConfigEntry 5 } dot11VHTBeamformeeNTxSupport OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of space-time streams that the STA can receive in a VHT NDP, the maximum value for NSTS, total that can be sent to the STA in a VHT MU PPDU if the STA is MU beamformee capable and the maximum value of Nr that the STA transmits in a VHT Compressed Beamforming frame." ::= { dot11VHTTransmitBeamformingConfigEntry 6 } -- ********************************************************************** -- * End of dot11 VHT Transmit Beamforming Config TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11 Phy TVHT TABLE -- ********************************************************************** dot11PhyTVHTTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyTVHTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyTVHTTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 25 } dot11PhyTVHTEntry OBJECT-TYPE SYNTAX Dot11PhyTVHTEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyTVHTEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11PhyTVHTTable 1 } Dot11PhyTVHTEntry ::= SEQUENCE { dot11TVHTChannelWidthOptionImplemented INTEGER, dot11TVHTCurrentChannelWidth INTEGER, dot11TVHTCurrentChannelCenterFrequencyIndex0 Unsigned32, dot11TVHTCurrentChannelCenterFrequencyIndex1 Unsigned32, dot11TVHTShortGIOptionIn4WImplemented TruthValue, dot11TVHTShortGIOptionIn4WActivated TruthValue, dot11TVHTLDPCCodingOptionImplemented TruthValue, dot11TVHTLDPCCodingOptionActivated TruthValue, dot11TVHTTxSTBCOptionImplemented TruthValue, dot11TVHTTxSTBCOptionActivated TruthValue, dot11TVHTRxSTBCOptionImplemented TruthValue, dot11TVHTRxSTBCOptionActivated TruthValue, dot11TVHTMUMaxUsersImplemented Unsigned32, dot11TVHTMUMaxNSTSPerUserImplemented Unsigned32, dot11TVHTMUMaxNSTSTotalImplemented Unsigned32, dot11TVHTMaxNTxChainsImplemented Unsigned32, dot11TVHTMaxNTxChainsActivated Unsigned32 } dot11TVHTChannelWidthOptionImplemented OBJECT-TYPE SYNTAX INTEGER { tvhtmode1(0), tvhtmode2c(1), tvhtmode2n(2), tvhtmode4c(3), tvhtmode4n(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the channel widths supported: W MHz, 2W MHz, W+W MHz, 4W MHz or 2W+2W MHz." ::= { dot11PhyTVHTEntry 1 } dot11TVHTCurrentChannelWidth OBJECT-TYPE SYNTAX INTEGER { tvhtw(0), tvht2w(1), tvhtwpw(2), tvht4w(3), tvht2wp2w(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. Written by the PHY. This attribute indicates the operating channel width." DEFVAL { tvhtw } ::= { dot11PhyTVHTEntry 2 } dot11TVHTCurrentChannelCenterFrequencyIndex0 OBJECT-TYPE SYNTAX Unsigned32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. Written by the PHY. For a W MHz, 2W MHz or 4W MHz channel, denotes the channel center frequency. For an W+W or 2W+2W MHz channel, denotes the center frequency of frequency segment 0. See 22.3.14." DEFVAL { 0 } ::= { dot11PhyTVHTEntry 3 } dot11TVHTCurrentChannelCenterFrequencyIndex1 OBJECT-TYPE SYNTAX Unsigned32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. Written by the PHY. For an W+W or 2W+2W MHz channel, denotes the center frequency of frequency segment 1. Set to 0 for a W MHz, 2W MHz or 4W MHz channel. See 22.3.14." DEFVAL { 0 } ::= { dot11PhyTVHTEntry 4 } dot11TVHTShortGIOptionIn4WImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving 4W MHz short guard interval packets." ::= { dot11PhyTVHTEntry 5 } dot11TVHTShortGIOptionIn4WActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the reception of 4W MHz short guard interval packets is enabled." DEFVAL { false } ::= { dot11PhyTVHTEntry 6 } dot11TVHTLDPCCodingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the LDPC coding option for TVHT packets is implemented." ::= { dot11PhyTVHTEntry 7 } dot11TVHTLDPCCodingOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the LDPC coding option for TVHT packets is enabled." DEFVAL { false } ::= { dot11PhyTVHTEntry 8 } dot11TVHTTxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of transmitting TVHT PPDUs using STBC." ::= { dot11PhyTVHTEntry 9 } dot11TVHTTxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the entity's capability for transmitting TVHT PPDUs using STBC is enabled." DEFVAL { false } ::= { dot11PhyTVHTEntry 10 } dot11TVHTRxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving TVHT PPDUs using STBC." ::= { dot11PhyTVHTEntry 11 } dot11TVHTRxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the entity's capability for receiving TVHT PPDUs using STBC is enabled." DEFVAL { false } ::= { dot11PhyTVHTEntry 12 } dot11TVHTMUMaxUsersImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of users to which this device is capable of transmitting within a TVHT MU PPDU." ::= { dot11PhyTVHTEntry 13 } dot11TVHTMUMaxNSTSPerUserImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of space-time streams per user that this device is capable of transmitting within a TVHT MU PPDU." ::= { dot11PhyTVHTEntry 14 } dot11TVHTMUMaxNSTSTotalImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of space-time streams for all users that this device is capable of transmitting within a TVHT MU PPDU." ::= { dot11PhyTVHTEntry 15 } dot11TVHTMaxNTxChainsImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of transmit chains within this device." ::= { dot11PhyTVHTEntry 16 } dot11TVHTMaxNTxChainsActivated OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum number of transmit chains that are activated within this device, unless this attribute exceeds dot11TVHTMaxNTxChainsImplemented, in which case the maximum number of transmit chains that are activated within this device is equal to dot11TVHTMaxNTxChainsImplemented." DEFVAL { 2147483647 } ::= { dot11PhyTVHTEntry 17 } -- ********************************************************************** -- * End of dot11PhyTVHT TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11 TVHT Transmit Beamforming Config TABLE -- ********************************************************************** dot11TVHTTransmitBeamformingConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11TVHTTransmitBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11TVHTTransmitBeamformingConfigTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 26 } dot11TVHTTransmitBeamformingConfigEntry OBJECT-TYPE SYNTAX Dot11TVHTTransmitBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11TVHTTransmitBeamformingConfig Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11TVHTTransmitBeamformingConfigTable 1 } Dot11TVHTTransmitBeamformingConfigEntry ::= SEQUENCE { dot11TVHTSUBeamformeeOptionImplemented TruthValue, dot11TVHTSUBeamformerOptionImplemented TruthValue, dot11TVHTMUBeamformeeOptionImplemented TruthValue, dot11TVHTMUBeamformerOptionImplemented TruthValue, dot11TVHTNumberSoundingDimensions Unsigned32, dot11TVHTBeamformeeNTxSupport Unsigned32 } dot11TVHTSUBeamformeeOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the SU Beamformee role." ::= { dot11TVHTTransmitBeamformingConfigEntry 1 } dot11TVHTSUBeamformerOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the SU Beamformer role." ::= { dot11TVHTTransmitBeamformingConfigEntry 2 } dot11TVHTMUBeamformeeOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the MU Beamformee role." ::= { dot11TVHTTransmitBeamformingConfigEntry 3 } dot11TVHTMUBeamformerOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the MU Beamformer role." ::= { dot11TVHTTransmitBeamformingConfigEntry 4 } dot11TVHTNumberSoundingDimensions OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the number of antennas used by the beamformer when sending beamformed transmissions." ::= { dot11TVHTTransmitBeamformingConfigEntry 5 } dot11TVHTBeamformeeNTxSupport OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of space-time streams that the STA can receive in a TVHT NDP, the maximum value for NSTS, total that can be sent to the STA in a TVHT MU PPDU if the STA is MU beamformee capable and the maximum value of Nr that the STA transmits in a TVHT Compressed Beamforming frame." ::= { dot11TVHTTransmitBeamformingConfigEntry 6 } -- ********************************************************************** -- * End of dot11 TVHT Transmit Beamforming Config TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11 Phy S1G TABLE -- ********************************************************************** dot11PhyS1GTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PhyS1GEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyS1GTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 27 } dot11PhyS1GEntry OBJECT-TYPE SYNTAX Dot11PhyS1GEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PhyHTEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11PhyS1GTable 1 } Dot11PhyS1GEntry ::= SEQUENCE { dot11S1GChannelWidthOptionImplemented INTEGER, dot11S1GCurrentPrimaryChannel Unsigned32, dot11S1GCurrentChannelWidth INTEGER, dot11S1GCurrentChannelCenterFrequencyIndex Unsigned32, dot11ShortGIOptionIn1MImplemented TruthValue, dot11ShortGIOptionIn1MActivated TruthValue, dot11ShortGIOptionIn2MImplemented TruthValue, dot11ShortGIOptionIn2MActivated TruthValue, dot11ShortGIOptionIn4MImplemented TruthValue, dot11ShortGIOptionIn4MActivated TruthValue, dot11ShortGIOptionIn8MImplemented TruthValue, dot11ShortGIOptionIn8MActivated TruthValue, dot11ShortGIOptionIn16MImplemented TruthValue, dot11ShortGIOptionIn16MActivated TruthValue, dot11S1GLDPCCodingOptionImplemented TruthValue, dot11S1GLDPCCodingOptionActivated TruthValue, dot11S1GTxSTBCOptionImplemented TruthValue, dot11S1GTxSTBCOptionActivated TruthValue, dot11S1GRxSTBCOptionImplemented TruthValue, dot11S1GRxSTBCOptionActivated TruthValue, dot11S1GMUMaxUsersImplemented Unsigned32, dot11S1GMUMaxNSTSPerUserImplemented Unsigned32, dot11S1GMUMaxNSTSTotalImplemented Unsigned32, dot11S1GMaxNTxChainsImplemented Unsigned32, dot11S1GMaxNTxChainsActivated Unsigned32, dot11S1GTravelingPilotOptionImplemented TruthValue, dot11S1GTravelingPilotOptionActivated TruthValue, dot11S1GLONGOptionImplemented TruthValue, dot11S1GLONGOptionActivated TruthValue } dot11S1GChannelWidthOptionImplemented OBJECT-TYPE SYNTAX INTEGER { contiguous2(0), contiguous4(1), contiguous8(2), contiguous16(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the channel widths supported: 1/2 MHz, 1/2/4 MHz, 1/2/4/8 MHz or 1/2/4/8/16 MHz." ::= { dot11PhyS1GEntry 1 } dot11S1GCurrentPrimaryChannel OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. This attribute indicates the channel number of the 2 MHz primary channel or of the 1 MHz primary channel." ::= { dot11PhyS1GEntry 2 } dot11S1GCurrentChannelWidth OBJECT-TYPE SYNTAX INTEGER { cbw1(0), cbw2(1), cbw4(2), cbw8(3), cbw16(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. This attribute indicates the operating channel width." DEFVAL { cbw1 } ::= { dot11PhyS1GEntry 3 } dot11S1GCurrentChannelCenterFrequencyIndex OBJECT-TYPE SYNTAX Unsigned32 (0..200) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the PHY. For a 1 MHz, 2 MHz, 4 MHz, 8 MHz, or 16 MHz channel, denotes the channel center frequency." DEFVAL { 0 } ::= { dot11PhyS1GEntry 4 } dot11ShortGIOptionIn1MImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving 1 MHz short guard interval packets." ::= { dot11PhyS1GEntry 5 } dot11ShortGIOptionIn1MActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the reception of 1 MHz short guard interval packets is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 6 } dot11ShortGIOptionIn2MImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving 2 MHz short guard interval packets." ::= { dot11PhyS1GEntry 7 } dot11ShortGIOptionIn2MActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the reception of 2 MHz short guard interval packets is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 8 } dot11ShortGIOptionIn4MImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving 4 MHz short guard interval packets." ::= { dot11PhyS1GEntry 9 } dot11ShortGIOptionIn4MActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the reception of 4 MHz short guard interval packets is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 10 } dot11ShortGIOptionIn8MImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving 8 MHz short guard interval packets." ::= { dot11PhyS1GEntry 11 } dot11ShortGIOptionIn8MActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the reception of 8 MHz short guard interval packets is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 12 } dot11ShortGIOptionIn16MImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving 16 MHz short guard interval packets." ::= { dot11PhyS1GEntry 13 } dot11ShortGIOptionIn16MActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the reception of 16 MHz short guard interval packets is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 14 } dot11S1GLDPCCodingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the LDPC coding option for S1G packets is implemented." ::= { dot11PhyS1GEntry 15 } dot11S1GLDPCCodingOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the LDPC coding option for S1G packets is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 16 } dot11S1GTxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of transmitting S1G PPDUs using STBC." ::= { dot11PhyS1GEntry 17 } dot11S1GTxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the entity's capability for transmitting S1G PPDUs using STBC is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 18 } dot11S1GRxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving S1G PPDUs using STBC." ::= { dot11PhyS1GEntry 19 } dot11S1GRxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the entity's capability for receiving S1G PPDUs using STBC is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 20 } dot11S1GMUMaxUsersImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of users to which this device is capable of transmitting within an S1G MU PPDU." ::= { dot11PhyS1GEntry 21 } dot11S1GMUMaxNSTSPerUserImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of space-time streams per user that this device is capable of transmitting within an S1G MU PPDU." ::= { dot11PhyS1GEntry 22 } dot11S1GMUMaxNSTSTotalImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of space-time streams for all users that this device is capable of transmitting within an S1G MU PPDU." ::= { dot11PhyS1GEntry 23 } dot11S1GMaxNTxChainsImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of transmit chains within this device." ::= { dot11PhyS1GEntry 24 } dot11S1GMaxNTxChainsActivated OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum number of transmit chains that are activated within this device, unless this attribute exceeds dot11S1GMaxNTxChainsImplemented, in which case the maximum number of transmit chains that are activated within this device is equal to dot11S1GMaxNTxChainsImplemented." DEFVAL { 1 } ::= { dot11PhyS1GEntry 25 } dot11S1GTravelingPilotOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the traveling pilot option is implemented." ::= { dot11PhyS1GEntry 26 } dot11S1GTravelingPilotOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the traveling pilot option is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 27 } dot11S1GLONGOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the S1G_Long operation is implemented." ::= { dot11PhyS1GEntry 28 } dot11S1GLONGOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the S1G_Long operation is enabled." DEFVAL { false } ::= { dot11PhyS1GEntry 29 } -- ********************************************************************** -- * End of dot11PhyS1G TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11 S1G Transmit Beamforming Config TABLE -- ********************************************************************** dot11S1GTransmitBeamformingConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11S1GTransmitBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11S1GTransmitBeamformingConfigTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an Agent." ::= { dot11phy 28 } dot11S1GTransmitBeamformingConfigEntry OBJECT-TYPE SYNTAX Dot11S1GTransmitBeamformingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11S1GTransmitBeamformingConfig Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11S1GTransmitBeamformingConfigTable 1 } Dot11S1GTransmitBeamformingConfigEntry ::= SEQUENCE { dot11S1GSUBeamformerOptionImplemented TruthValue, dot11S1GSUBeamformeeOptionImplemented TruthValue, dot11S1GMUBeamformerOptionImplemented TruthValue, dot11S1GMUBeamformeeOptionImplemented TruthValue, dot11S1GNumberSoundingDimensions Unsigned32, dot11S1GBeamformeeNTxSupport Unsigned32 } dot11S1GSUBeamformeeOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the SU Beamformee role." ::= { dot11S1GTransmitBeamformingConfigEntry 1 } dot11S1GSUBeamformerOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the SU Beamformer role." ::= { dot11S1GTransmitBeamformingConfigEntry 2 } dot11S1GMUBeamformeeOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the MU Beamformee role." ::= { dot11S1GTransmitBeamformingConfigEntry 3 } dot11S1GMUBeamformerOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the STA supports the MU Beamformer role." ::= { dot11S1GTransmitBeamformingConfigEntry 4 } dot11S1GNumberSoundingDimensions OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the number of antennas used by the beamformer when sending beamformed tansmissions." ::= { dot11S1GTransmitBeamformingConfigEntry 5 } dot11S1GBeamformeeNTxSupport OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of space-time streams that the STA can receive in an S1G NDP, the maximum value for NSTS,total that can be sent to the STA in an S1G MU PPDU if the STA is MU beamformee capable and the maximum value of Nr that the STA transmits in an S1G Compressed Beamforming frame." ::= { dot11S1GTransmitBeamformingConfigEntry 6 } -- ********************************************************************** -- * End of dot11 S1G Transmit Beamforming Config TABLE -- ********************************************************************** --*********************************************************************** -- * dot11 Phy CDMG TABLE --*********************************************************************** dot11PHYCDMGTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PHYCDMGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyCDMGTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an agent." ::= { dot11phy 29 } dot11PHYCDMGEntry OBJECT-TYPE SYNTAX Dot11PHYCDMGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PHYCDMGEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11PHYCDMGTable 1 } Dot11PHYCDMGEntry ::= SEQUENCE { dot11CDMGLowPowerSCPHYImplemented TruthValue, dot11CDMGLowPowerSCPHYActivated TruthValue } dot11CDMGLowPowerSCPHYImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the CDMG low power SC PHY is implemented." ::= { dot11PHYCDMGEntry 1 } dot11CDMGLowPowerSCPHYActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the CDMG low power SC PHY is activated." DEFVAL { false } ::= { dot11PHYCDMGEntry 2 } -- ********************************************************************** -- * End of dot11 PHY CDMG TABLE -- ********************************************************************** --*********************************************************************** -- * dot11 Phy CMMG TABLE --*********************************************************************** dot11PHYCMMGTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11PHYCMMGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of attributes for dot11PhyCMMGTable. Implemented as a table indexed on ifIndex to allow for multiple instances on an agent." ::= { dot11phy 30 } dot11PHYCMMGEntry OBJECT-TYPE SYNTAX Dot11PHYCMMGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the dot11PHYCMMGEntry Table. ifIndex - Each IEEE 802.11 interface is represented by an ifEntry. Interface tables in this MIB module are indexed by ifIndex." INDEX {ifIndex} ::= { dot11PHYCMMGTable 1 } Dot11PHYCMMGEntry ::= SEQUENCE { dot11CMMGCurrentChannelWidth INTEGER, dot11CMMGCurrentChannelCenterFrequencyIndex Unsigned32, dot11CMMGShortGIOptionImplemented TruthValue, dot11CMMGShortGIOptionActivated TruthValue, dot11CMMGTxSTBCOptionImplemented TruthValue, dot11CMMGTxSTBCOptionActivated TruthValue, dot11CMMGRxSTBCOptionImplemented TruthValue, dot11CMMGRxSTBCOptionActivated TruthValue, dot11CMMGBeamFormingOptionImplemented TruthValue, dot11CMMGBeamFormingOptionActivated TruthValue, dot11CMMGMaxNTxChainsImplemented Unsigned32, dot11CMMGMaxNTxChainsActivated Unsigned32 } dot11CMMGCurrentChannelWidth OBJECT-TYPE SYNTAX INTEGER { cbw540(0), cbw1080(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. Written by the PHY. This attribute indicates the operating channel width." DEFVAL { cbw540 } ::= { dot11PHYCMMGEntry 1 } dot11CMMGCurrentChannelCenterFrequencyIndex OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. Written by the PHY. Denotes the channel center frequency. If dot11CMMGCurrentChannelWidth is cbw1080(1) then it does not exceed 5. See 25.10." ::= { dot11PHYCMMGEntry 2 } dot11CMMGShortGIOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving short guard interval packets." ::= { dot11PHYCMMGEntry 3 } dot11CMMGShortGIOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the reception of short guard interval packets is enabled." DEFVAL { false } ::= { dot11PHYCMMGEntry 4 } dot11CMMGTxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of transmitting CMMG PPDUs using STBC." ::= { dot11PHYCMMGEntry 5 } dot11CMMGTxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the entity's capability of transmitting frames using STBC option is enabled." DEFVAL { false } ::= { dot11PHYCMMGEntry 6 } dot11CMMGRxSTBCOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the device is capable of receiving CMMG PPDUs using STBC." ::= { dot11PHYCMMGEntry 7 } dot11CMMGRxSTBCOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. Changes made while associated with an AP or while operating a BSS should take effect only after disassociation or the deactivation of the BSS, respectively. This attribute, when true, indicates that the entity's capability for receiving CMMG PPDUs using STBC is enabled." DEFVAL { false } ::= { dot11PHYCMMGEntry 8 } dot11CMMGBeamFormingOptionImplemented OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute, when true, indicates that the beamforming option is implemented." ::= { dot11PHYCMMGEntry 9 } dot11CMMGBeamFormingOptionActivated OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute, when true, indicates that the beamforming option is enabled." DEFVAL { false } ::= { dot11PHYCMMGEntry 10 } dot11CMMGMaxNTxChainsImplemented OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a capability variable. Its value is determined by device capabilities. This attribute indicates the maximum number of transmit chains within this device." ::= { dot11PHYCMMGEntry 11 } dot11CMMGMaxNTxChainsActivated OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute indicates the maximum number of transmit chains that are activated within this device, unless this attribute exceeds dot11CMMGMax- NTxChainsImplemented, in which case the maximum number of transmit chains that are activated within this device is equal to dot11CMMGMaxNTxChainsImplemented." DEFVAL { 2147483647 } ::= { dot11PHYCMMGEntry 12 } -- ***************************************************************** -- * End of dot11 PHY CMMG TABLE -- ***************************************************************** -- Interworking Management (IMT) Attributes -- DEFINED AS "The Interworking management object class provides -- the necessary support for an SSPN Interface function to manage -- interworking with external systems. IMT objects are conceptual -- objects for Interworking Service and are defined only for the -- AP." dot11imt OBJECT IDENTIFIER ::= {ieee802dot11 6} -- IMT GROUPS -- dot11BSSIdTable ::= { dot11imt 1 } -- dot11InterworkingTable ::= { dot11imt 2 } -- dot11APLCITable ::= { dot11imt 3 } -- dot11APCivicLocation Table ::= { dot11imt 4 } -- dot11RoamingConsortiumTable ::= { dot11imt 5 } -- dot11DomainNameTable ::= { dot11imt 6 } -- Generic Advertisement Service (GAS) Attributes -- DEFINED AS "The Generic Advertisement Service management -- object class provides the necessary support for an Advertisement -- service to interwork with external systems." -- GAS GROUPS -- dot11GASAdvertisementTable ::= { dot11imt 7 } --********************************************************************** -- * dot11BSSId TABLE --********************************************************************** dot11BSSIdTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11BSSIdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is a table of BSSIDs contained within an Access Point (AP)." ::= { dot11imt 1 } dot11BSSIdEntry OBJECT-TYPE SYNTAX Dot11BSSIdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object provides the attributes identifying a particular BSSID within an AP." INDEX { dot11APMacAddress } ::= { dot11BSSIdTable 1 } Dot11BSSIdEntry ::= SEQUENCE { dot11APMacAddress MacAddress } dot11APMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. Changes take effect for the next MLME-START.request primitive. This object specifies the MAC address of the BSSID represented on a particular BSSID interface and uniquely identifies this entry." ::= { dot11BSSIdEntry 1 } --********************************************************************** -- * End of dot11BSSId TABLE --********************************************************************** --********************************************************************** -- * dot11Interworking TABLE --********************************************************************** dot11InterworkingTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11InterworkingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table represents the non-AP STAs associated to the AP. An entry is created automatically by the AP when the STA becomes associated to the AP. The corresponding entry is deleted when the STA disassociates. Each STA added to this table is uniquely identified by its MAC address. This table is moved to a new AP following a successful STA BSS transition event." ::= { dot11imt 2 } dot11InterworkingEntry OBJECT-TYPE SYNTAX Dot11InterworkingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represents a conceptual row in the dot11InterworkingTable and provides information about permissions received from an SSPN Interface. If a non-AP STA does not receive permissions for one or more of these objects, then the object's default values or AP's locally defined configuration may be used instead. If the AP's local policy(s) is more restrictive than an object's value received from the SSPN Interface, then the AP's local policy shall be enforced. An entry is identified by the AP's MAC address to which the STA is associated and the STA's MAC address." INDEX { dot11APMacAddress, dot11NonAPStationMacAddress } ::= { dot11InterworkingTable 1 } Dot11InterworkingEntry ::= SEQUENCE { dot11NonAPStationMacAddress MacAddress, dot11NonAPStationUserIdentity DisplayString, dot11NonAPStationInterworkingCapability BITS, dot11NonAPStationAssociatedSSID OCTET STRING, dot11NonAPStationUnicastCipherSuite OCTET STRING, dot11NonAPStationBroadcastCipherSuite OCTET STRING, dot11NonAPStationAuthAccessCategories BITS, dot11NonAPStationAuthMaxVoiceRate Unsigned32, dot11NonAPStationAuthMaxVideoRate Unsigned32, dot11NonAPStationAuthMaxBestEffortRate Unsigned32, dot11NonAPStationAuthMaxBackgroundRate Unsigned32, dot11NonAPStationAuthMaxVoiceOctets Unsigned32, dot11NonAPStationAuthMaxVideoOctets Unsigned32, dot11NonAPStationAuthMaxBestEffortOctets Unsigned32, dot11NonAPStationAuthMaxBackgroundOctets Unsigned32, dot11NonAPStationAuthMaxHCCAHEMMOctets Unsigned32, dot11NonAPStationAuthMaxTotalOctets Unsigned32, dot11NonAPStationAuthHCCAHEMM TruthValue, dot11NonAPStationAuthMaxHCCAHEMMRate Unsigned32, dot11NonAPStationAuthHCCAHEMMDelay Unsigned32, dot11NonAPStationAuthSourceMulticast TruthValue, dot11NonAPStationAuthMaxSourceMulticastRate Unsigned32, dot11NonAPStationVoiceMSDUCount Counter32, dot11NonAPStationDroppedVoiceMSDUCount Counter32, dot11NonAPStationVoiceOctetCount Counter32, dot11NonAPStationDroppedVoiceOctetCount Counter32, dot11NonAPStationVideoMSDUCount Counter32, dot11NonAPStationDroppedVideoMSDUCount Counter32, dot11NonAPStationVideoOctetCount Counter32, dot11NonAPStationDroppedVideoOctetCount Counter32, dot11NonAPStationBestEffortMSDUCount Counter32, dot11NonAPStationDroppedBestEffortMSDUCount Counter32, dot11NonAPStationBestEffortOctetCount Counter32, dot11NonAPStationDroppedBestEffortOctetCount Counter32, dot11NonAPStationBackgroundMSDUCount Counter32, dot11NonAPStationDroppedBackgroundMSDUCount Counter32, dot11NonAPStationBackgroundOctetCount Counter32, dot11NonAPStationDroppedBackgroundOctetCount Counter32, dot11NonAPStationHCCAHEMMMSDUCount Counter32, dot11NonAPStationDroppedHCCAHEMMMSDUCount Counter32, dot11NonAPStationHCCAHEMMOctetCount Counter32, dot11NonAPStationDroppedHCCAHEMMOctetCount Counter32, dot11NonAPStationMulticastMSDUCount Counter32, dot11NonAPStationDroppedMulticastMSDUCount Counter32, dot11NonAPStationMulticastOctetCount Counter32, dot11NonAPStationDroppedMulticastOctetCount Counter32, dot11NonAPStationPowerManagementMode INTEGER, dot11NonAPStationAuthDls TruthValue, dot11NonAPStationVLANId Unsigned32, dot11NonAPStationVLANName DisplayString, dot11NonAPStationAddtsResultCode INTEGER} dot11NonAPStationMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after a non-AP STA associates to the BSS. This object specifies the MAC address of the non-AP STA for this entry and uniquely identifies this entry." ::= { dot11InterworkingEntry 1 } dot11NonAPStationUserIdentity OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after a non-AP STA associates to the BSS. This attribute reflects the user identity for the subscriber operating this non-AP STA" ::= { dot11InterworkingEntry 2 } dot11NonAPStationInterworkingCapability OBJECT-TYPE SYNTAX BITS { interworkingCapability(0), qosMapCapability(1), expeditedBwReqCapability(2), msgcfCapability(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after a non-AP STA associates to the BSS. This attribute defines the Interworking capabilities possessed by a non-AP STA. Interworking Capability is set to 1 when the STA includes the Interworking element in its (re)association request. The QosMapCapability, ExpeditedBwReqCapability and MSGCFCapability bits reflect the same values and meanings as those defined in 9.4.2.26" ::= { dot11InterworkingEntry 3 } dot11NonAPStationAssociatedSSID OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after a non-AP STA associates to the BSS. This attribute reflects the SSID to which the non-AP STA is associated" ::= { dot11InterworkingEntry 4 } dot11NonAPStationUnicastCipherSuite OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after a non-AP STA authenticates with the BSS. The selector of the AKM cipher suite that is currently in use by the non-AP STA. It consists of an OUI or CID (the first 3 octets) and a cipher suite identifier (the last octet)." ::= { dot11InterworkingEntry 5 } dot11NonAPStationBroadcastCipherSuite OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after a non-AP STA authenticates with the BSS. The selector of an AKM suite for broadcast and group addressed frame transmissions. It consists of an OUI or CID (the first 3 octets) and a cipher suite identifier the last octet)." ::= { dot11InterworkingEntry 6 } dot11NonAPStationAuthAccessCategories OBJECT-TYPE SYNTAX BITS { bestEffort(0), background(1), video(2), voice(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. The object that represents the access categories which the non-AP STA is permitted to use when admission control is configured on that AC. An AC is permitted to be used if its corresponding bit is set to 1; otherwise it is not permitted to be used." DEFVAL { { bestEffort, background, video, voice } } ::= { dot11InterworkingEntry 7 } dot11NonAPStationAuthMaxVoiceRate OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "kb/s" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized data rate the non-AP STA may use, either transmitting to an AP or receiving from an AP on the voice access category. If this rate is exceeded, the AP should police the flows traversing this AC. The value '4294967295', which is the default value, means that the SSP is not requesting the AP to limit the data rate used by the non-AP STA. Local configuration of the AP, however, might cause the rate to be limited, especially when the AC is configured for mandatory admission control." DEFVAL {4294967295} ::= { dot11InterworkingEntry 8 } dot11NonAPStationAuthMaxVideoRate OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "kb/s" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized data rate the non-AP STA may use, either transmitting to an AP or receiving from an AP on the video access category. If this rate is exceeded, the AP should police the flows traversing this AC. The value '4294967295', which is the default value, means that the SSP is not requesting the AP to limit the data rate used by the non-AP STA. Local configuration of the AP, however, might cause the rate to be limited, especially when the AC is configured for mandatory admission control." DEFVAL {4294967295} ::= { dot11InterworkingEntry 9 } dot11NonAPStationAuthMaxBestEffortRate OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "kb/s" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized data rate the non-AP STA may use, either transmitting to an AP or receiving from an AP on the best effort access category. If this rate is exceeded, the AP should police the flows traversing this AC. The value '4294967295', which is the default value, means that the SSP is not requesting the AP to limit the data rate used by the non-AP STA. Local configuration of the AP, however, might cause the rate to be limited, especially when the AC is configured for mandatory admission control." DEFVAL {4294967295} ::= { dot11InterworkingEntry 10 } dot11NonAPStationAuthMaxBackgroundRate OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "kb/s" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized data rate the non-AP STA may use, either transmitting to an AP or receiving from an AP on the background access category. If this rate is exceeded, the AP should police the flows traversing this AC. The value '4294967295', which is the default value, means that the SSP is not requesting the AP to limit the data rate used by the non-AP STA. Local configuration of the AP, however, might cause the rate to be limited, especially when the AC is configured for mandatory admission control." DEFVAL {4294967295} ::= { dot11InterworkingEntry 11 } dot11NonAPStationAuthMaxVoiceOctets OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized total octet count that a STA may use on the voice access category. If this octet count is exceeded, the AP should disassociate the non-AP STA. A value of 0 indicates that there is no octet limit." DEFVAL {0} ::= { dot11InterworkingEntry 12 } dot11NonAPStationAuthMaxVideoOctets OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized total octet count that a STA may use on the video access category. If this octet count is exceeded, the AP should disassociate the non-AP STA. A value of 0 indicates that there is no octet limit." DEFVAL {0} ::= { dot11InterworkingEntry 13 } dot11NonAPStationAuthMaxBestEffortOctets OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized total octet count that a STA may use on the best effort access category. If this octet count is exceeded, the AP should disassociate the non-AP STA. A value of 0 indicates that there is no octet limit." DEFVAL {0} ::= { dot11InterworkingEntry 14 } dot11NonAPStationAuthMaxBackgroundOctets OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized total octet count that a STA may use on the background access category. If this octet count is exceeded, the AP should disassociate the non-AP STA. A value of 0 indicates that there is no octet limit." DEFVAL {0} ::= { dot11InterworkingEntry 15 } dot11NonAPStationAuthMaxHCCAHEMMOctets OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized total octet count that a STA may use with HCCA or HEMM access. If this octet count is exceeded, the AP should disassociate the non-AP STA. A value of 0 indicates that there is no octet limit." DEFVAL {0} ::= { dot11InterworkingEntry 16 } dot11NonAPStationAuthMaxTotalOctets OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized total octet count that a STA may use on all access categories combined. If this octet count is exceeded, the AP should disassociate the non-AP STA. A value of 0 indicates that there is no octet limit." DEFVAL {0} ::= { dot11InterworkingEntry 17 } dot11NonAPStationAuthHCCAHEMM OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute, when true, indicates that the non-AP STA is permitted by the SSP to request HCCA or HEMM service via ADDTS frames. If this attribute is false, then HCCA or HEMM service is not permitted by the SSP." DEFVAL {true} ::= { dot11InterworkingEntry 18 } dot11NonAPStationAuthMaxHCCAHEMMRate OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "kb/s" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized data rate the non-AP STA may use, either transmitting to an AP or receiving from an AP via HCCA or HEMM. The value '4294967295', which is the default value, means that the SSP is not requesting the AP to limit the data rate used by the non-AP STA. Local configuration of the AP, however, might cause the rate to be otherwise limited." DEFVAL {4294967295} ::= { dot11InterworkingEntry 19 } dot11NonAPStationAuthHCCAHEMMDelay OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "microseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the delay bound for frames queued at an AP to a non-AP STA in the HCCA or HEMM queue. An AP should deliver frames to the non-AP STA within the time period specified in this attribute. When a non-AP STA requests admission control to the HCCA or HEMM queue, the requested delay will be equal to or higher than this value. The value '4294967295', which is the default value, means that the SSP is not requesting the AP limit the delay bound in this queue for transmissions to the non-AP STA." DEFVAL {4294967295} ::= { dot11InterworkingEntry 20 } dot11NonAPStationAuthSourceMulticast OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute, when true, indicates that the AP's MAC sublayer shall perform rate limiting to enforce the resource utilization limit in dot11NonAPStationAuthMaxSourceMulticastRate in the dot11InterworkingEntry identified by the source MAC address of the received frame. If this attribute is false, at an AP for which dot11SSPNInterfaceActivated is true, upon receipt of a frame with the Type subfield equal to Data with group DA, then the AP's MAC sublayer shall discard the frame." DEFVAL {true} ::= { dot11InterworkingEntry 21 } dot11NonAPStationAuthMaxSourceMulticastRate OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) UNITS "kb/s" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute indicates the maximum authorized data rate which the non-AP STA may transmit group addressed frames to an AP. If this rate is exceeded, the AP should police the flows. The value '4294967295', which is the default value, means that the SSP is not requesting the AP to limit the multicast data rate used by the non-AP STA." DEFVAL {4294967295} ::= { dot11InterworkingEntry 22 } dot11NonAPStationVoiceMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each MSDU successfully transmitted by the AP on the voice access category and for each MSDU received on either user priority 6 or 7." ::= { dot11InterworkingEntry 23 } dot11NonAPStationDroppedVoiceMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each MSDU dropped by the AP on the voice access category." ::= { dot11InterworkingEntry 24 } dot11NonAPStationVoiceOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented by the octet length of each MSDU successfully transmitted by the AP on the voice access category and by the octet length of each MSDU received on either user priority 6 or 7." ::= { dot11InterworkingEntry 25 } dot11NonAPStationDroppedVoiceOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each octet dropped by the AP on the voice access category." ::= { dot11InterworkingEntry 26 } dot11NonAPStationVideoMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each MSDU successfully transmitted by the AP on the video access category and for each MSDU received on either user priority 4 or 5." ::= { dot11InterworkingEntry 27 } dot11NonAPStationDroppedVideoMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each MSDU dropped by the AP on the video access category." ::= { dot11InterworkingEntry 28 } dot11NonAPStationVideoOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented by the octet length of each MSDU successfully transmitted by the AP on the voice access category and by the octet length of each MSDU received on either user priority 4 or 5." ::= { dot11InterworkingEntry 29 } dot11NonAPStationDroppedVideoOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each octet dropped by the AP on the video access category." ::= { dot11InterworkingEntry 30 } dot11NonAPStationBestEffortMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each MSDU successfully transmitted by the AP on the best effort access category and for each MSDU received on either user priority 0 or 3. For DCF operation, this counter shall be incremented for each MSDU successfully transmitted or received by the AP." ::= { dot11InterworkingEntry 31 } dot11NonAPStationDroppedBestEffortMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each MSDU dropped by the AP on the best effort access category and for each MSDU dropped by the AP on either user priority 0 or 3. For DCF operation, this counter shall be incremented for each MSDU dropped by the AP." ::= { dot11InterworkingEntry 32 } dot11NonAPStationBestEffortOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented by the octet length of each MSDU successfully transmitted by the AP on the best effort access category and by the octet length of each MSDU received on either user priority 0 or 3. For DCF operation, this counter shall be incremented the octet length of each MSDU successfully transmitted or received by the AP." ::= { dot11InterworkingEntry 33 } dot11NonAPStationDroppedBestEffortOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for the octet length of each MSDU dropped by the AP on the best effort access category and by the octet length of each MSDU dropped by the AP for either user priority 0 or 3. For DCF operation, this counter shall be incremented for the octet length of each MSDU dropped by the AP." ::= { dot11InterworkingEntry 34 } dot11NonAPStationBackgroundMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each MSDU successfully transmitted by the AP on the background access category and for each MSDU received on either user priority 1 or 2." ::= { dot11InterworkingEntry 35 } dot11NonAPStationDroppedBackgroundMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented for each MSDU dropped by the AP on the background access category" ::= { dot11InterworkingEntry 36 } dot11NonAPStationBackgroundOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented by the octet length of each MSDU successfully transmitted by the AP on the background access category and by the octet length of each MSDU received on either user priority 1 or 2." ::= { dot11InterworkingEntry 37 } dot11NonAPStationDroppedBackgroundOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For EDCA operation, this counter shall be incremented by the octet length of each MSDU dropped by the AP on the background access category" ::= { dot11InterworkingEntry 38 } dot11NonAPStationHCCAHEMMMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For HCCA or HEMM operation, this counter shall be incremented for each MSDU successfully transmitted by the AP and for each MSDU received." ::= { dot11InterworkingEntry 39 } dot11NonAPStationDroppedHCCAHEMMMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For HCCA or HEMM operation, this counter shall be incremented for each MSDU dropped by the AP." ::= { dot11InterworkingEntry 40 } dot11NonAPStationHCCAHEMMOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For HCCA or HEMM operation, this counter shall be incremented by the octet length of each MSDU successfully transmitted by the AP and by the octet length of each MSDU received." ::= { dot11InterworkingEntry 41 } dot11NonAPStationDroppedHCCAHEMMOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For HCCA or HEMM operation, this counter shall be incremented by the octet length of each MSDU dropped by the AP." ::= { dot11InterworkingEntry 42 } dot11NonAPStationMulticastMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For Multicast operation, this counter shall be incremented for each group addressed MSDU successfully transmitted by the AP and for each group addressed MSDU received at the AP." ::= { dot11InterworkingEntry 43 } dot11NonAPStationDroppedMulticastMSDUCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For Multicast operation, this counter shall be incremented for each group addressed MSDU dropped by the AP." ::= { dot11InterworkingEntry 44 } dot11NonAPStationMulticastOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For Multicast operation, this counter shall be incremented by the octet length of each MSDU successfully transmitted by the AP and by the octet length of each group addressed MSDU received." ::= { dot11InterworkingEntry 45 } dot11NonAPStationDroppedMulticastOctetCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the completion of an MA-UNITDATA.confirm or MA-UNITDATA.indication primitive. For Multicast operation, this counter shall be incremented by the octet length of each group addressed MSDU dropped by the AP." ::= { dot11InterworkingEntry 46 } dot11NonAPStationPowerManagementMode OBJECT-TYPE SYNTAX INTEGER { active(1), powersave(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the AP's MAC after the non-AP STA changes its power management mode. This attribute indicates the power management mode of the non-AP STA." ::= { dot11InterworkingEntry 47 } dot11NonAPStationAuthDls OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Deprecated as the related feature has been removed from IEEE Std 802.11. This is a control variable. It is written by the SME after the AP receives the permissions for the non-AP STA from the SSPN Interface. This attribute, when true, indicates that the non-AP STA is permitted by the SSPN Interface to use direct link service (DLS). Note this attribute is an SSP permission and is independent of whether DLS is allowed in the BSS as governed by dot11DLSAllowedInQBSS. This service is disabled otherwise." DEFVAL {true} ::= { dot11InterworkingEntry 48 } dot11NonAPStationVLANId OBJECT-TYPE SYNTAX Unsigned32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after a non-AP STA associates to the BSS. This attribute indicates the VLAN ID on the an external network to which frames from the non-AP STA are bridged." ::= { dot11InterworkingEntry 49 } dot11NonAPStationVLANName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after a non-AP STA associates to the BSS. This attribute indicates the VLAN name corresponding to the VLAN ID on the external network to which frames from the non-AP STA are bridged." ::= { dot11InterworkingEntry 50 } dot11NonAPStationAddtsResultCode OBJECT-TYPE SYNTAX INTEGER { success(1), invalidParameters(2), rejectedWithSuggestedChanges(3), rejectedForDelayPeriod(4), rejectedForSspPermissions(5), rejectedWithSuggestedBssTransition (6), requestedTclasNotSupported (7), tclasResourcesExhausted (8), rejectedHomeWithSuggestedChanges (9) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MAC after the AP transmits an ADDTS Response frame to the non-AP STA or after the AP includes a RIC element in a Reassociation Response frame. This attribute indicates the most recent result code returned by the AP in an ADDTS Response." ::= { dot11InterworkingEntry 51 } -- ********************************************************************** -- * End of dot11Interworking TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11APLCI TABLE -- ********************************************************************** dot11APLCITable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11APLCIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table represents the Geospatial location of the AP as specified in 9.4.2.21.10." ::= { dot11imt 3 } dot11APLCIEntry OBJECT-TYPE SYNTAX Dot11APLCIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "AP location in geospatial coordinates" INDEX { dot11APLCIIndex } ::= { dot11APLCITable 1 } Dot11APLCIEntry ::= SEQUENCE { dot11APLCIIndex Unsigned32, dot11APLCILatitudeUncertainty Unsigned32, dot11APLCILatitudeInteger Integer32, dot11APLCILatitudeFraction Integer32, dot11APLCILongitudeUncertainty Unsigned32, dot11APLCILongitudeInteger Integer32, dot11APLCILongitudeFraction Integer32, dot11APLCIAltitudeType INTEGER, dot11APLCIAltitudeUncertainty Unsigned32, dot11APLCIAltitude Integer32, dot11APLCIDatum INTEGER, dot11APLCIAzimuthType INTEGER, dot11APLCIAzimuthResolution Unsigned32, dot11APLCIAzimuth Integer32 } dot11APLCIIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for AP LCI elements in dot11APLCITable, greater than 0." ::= { dot11APLCIEntry 1 } dot11APLCILatitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Latitude uncertainty is defined in IETF RFC 6225." ::= { dot11APLCIEntry 2 } dot11APLCILatitudeInteger OBJECT-TYPE SYNTAX Integer32 (-90..90) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Latitude is a 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of Latitude." ::= { dot11APLCIEntry 3 } dot11APLCILatitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Latitude is a 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of Latitude." ::= { dot11APLCIEntry 4 } dot11APLCILongitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude uncertainty is defined in IETF RFC 6225." ::= { dot11APLCIEntry 5 } dot11APLCILongitudeInteger OBJECT-TYPE SYNTAX Integer32 (-180..180) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude is a 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 9 bits of integer portion of Longitude." ::= { dot11APLCIEntry 6 } dot11APLCILongitudeFraction OBJECT-TYPE SYNTAX Integer32 (-16777215..16777215) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Longitude is a 2s complement 34-bit fixed point value consisting of 9 bits of integer and 25 bits of fraction. This field contains the 25 bits of fraction portion of Longitude." ::= { dot11APLCIEntry 7 } dot11APLCIAltitudeType OBJECT-TYPE SYNTAX INTEGER { meters(1), floors(2), hagm (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Altitude Type is four bits encoding the type of altitude. Codes defined are: meters in 2s complement fixed-point 22-bit integer part with 8-bit fraction floors in 2s complement fixed-point 22-bit integer part with 8-bit fraction hagm: Height Above Ground in meters, in 2s complement fixed-point 22-bit integer part with 8-bit fraction." ::= { dot11APLCIEntry 8 } dot11APLCIAltitudeUncertainty OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Altitude resolution is 6 bits indicating the number of valid bits in the altitude." ::= { dot11APLCIEntry 9 } dot11APLCIAltitude OBJECT-TYPE SYNTAX Integer32 (-536870912..536870911) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Altitude is a 30-bit value defined by the Altitude type field. The field is encoded as a 2s complement fixed-point 22-bit integer part with 8-bit fraction." ::= { dot11APLCIEntry 10 } -- Reserved: 11. Was dot11APLCIAltitudeFraction. dot11APLCIDatum OBJECT-TYPE SYNTAX INTEGER { wgs84 (1), nad83navd88 (2), nad93mllwvd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Datum is a 3-bit value encoding the horizontal and vertical references used for the coordinates given in this LCI. IETF RFC 6225 defines the values of Datum. Type 1 is WGS-84, the coordinate system used by GPS. Type 2 is NAD83 with NAVD88 vertical reference. Type 3 is NAD83 with Mean Lower Low Water vertical datum. All other types are reserved." ::= { dot11APLCIEntry 12 } dot11APLCIAzimuthType OBJECT-TYPE SYNTAX INTEGER { frontSurfaceOfSTA(0), radioBeam(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Azimuth Type is a one bit attribute encoding the type of Azimuth. Codes defined are: front surface of STA: in 2s complement fixed-point 9-bit integer radio beam: in 2s complement fixed-point 9-bit integer." ::= { dot11APLCIEntry 13 } dot11APLCIAzimuthResolution OBJECT-TYPE SYNTAX Unsigned32 (0..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Azimuth Resolution is 4 bits indicating the number of valid bits in the azimuth." ::= { dot11APLCIEntry 14 } dot11APLCIAzimuth OBJECT-TYPE SYNTAX Integer32 (-511..511) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Azimuth is a 9-bit value defined by the Azimuth Type field.The field is encoded as a 2s complement fixed-point 9-bit integer horizontal angle in degrees from true north." ::= { dot11APLCIEntry 15 } -- ********************************************************************** -- * End of dot11APLCI TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11APCivicLocation TABLE -- ********************************************************************** dot11APCivicLocationTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11ApCivicLocationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table represents the location of the AP in civic format using the Civic Address Type elements defined in IETF RFC 5139 [B45]." ::= { dot11imt 4 } dot11APCivicLocationEntry OBJECT-TYPE SYNTAX Dot11ApCivicLocationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Civic Address location of the AP described with Civic Address Type elements defined in IETF RFC 5139 [B45]." INDEX {dot11APCivicLocationIndex} ::= {dot11APCivicLocationTable 1} Dot11ApCivicLocationEntry ::= SEQUENCE { dot11APCivicLocationIndex Unsigned32, dot11APCivicLocationCountry OCTET STRING, dot11APCivicLocationA1 OCTET STRING, dot11APCivicLocationA2 OCTET STRING, dot11APCivicLocationA3 OCTET STRING, dot11APCivicLocationA4 OCTET STRING, dot11APCivicLocationA5 OCTET STRING, dot11APCivicLocationA6 OCTET STRING, dot11APCivicLocationPrd OCTET STRING, dot11APCivicLocationPod OCTET STRING, dot11APCivicLocationSts OCTET STRING, dot11APCivicLocationHno OCTET STRING, dot11APCivicLocationHns OCTET STRING, dot11APCivicLocationLmk OCTET STRING, dot11APCivicLocationLoc OCTET STRING, dot11APCivicLocationNam OCTET STRING, dot11APCivicLocationPc OCTET STRING, dot11APCivicLocationBld OCTET STRING, dot11APCivicLocationUnit OCTET STRING, dot11APCivicLocationFlr OCTET STRING, dot11APCivicLocationRoom OCTET STRING, dot11APCivicLocationPlc OCTET STRING, dot11APCivicLocationPcn OCTET STRING, dot11APCivicLocationPobox OCTET STRING, dot11APCivicLocationAddcode OCTET STRING, dot11APCivicLocationSeat OCTET STRING, dot11APCivicLocationRd OCTET STRING, dot11APCivicLocationRdsec OCTET STRING, dot11APCivicLocationRdbr OCTET STRING, dot11APCivicLocationRdsubbr OCTET STRING, dot11APCivicLocationPrm OCTET STRING, dot11APCivicLocationPom OCTET STRING } dot11APCivicLocationIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Index for APCivicLocation elements in dot11APCivicLocationTable, greater than 0." ::= { dot11APCivicLocationEntry 1 } dot11APCivicLocationCountry OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the two uppercase characters which correspond to the alpha-2 codes in ISO 3166-1. Example: US." ::= { dot11APCivicLocationEntry 2 } dot11APCivicLocationA1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the national subdivisions (state, Region, province, prefecture). Example: California. The A1 element is used for the top level subdivision within a country. In the absence of a country-specific guide on how to use the A-series of elements, the second part of the ISO 3166-2 code for a country subdivision SHOULD be used. The ISO 3166-2 code is a formed of a country code and hyphen plus a code of one, two or three characters or numerals. For the A1 element, the leading country code and hyphen are omitted and only the subdivision code is included. For example, the codes for Canada include CA-BC, CA-ON, CA-QC; Luxembourg has just three single character codes: LU-D, LU-G And LU-L; Australia uses both two and three character codes: AU-ACT, AU-NSW, AU-NT; France uses numerical codes for mainland France and letters for territories: FR-75, FR-NC." ::= { dot11APCivicLocationEntry 3 } dot11APCivicLocationA2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the county, parish, gun (JP), district (IN). Example: King's County." ::= { dot11APCivicLocationEntry 4 } dot11APCivicLocationA3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the city, township, shi (JP). Example: San Francisco." ::= { dot11APCivicLocationEntry 5 } dot11APCivicLocationA4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the city division, borough, city district, ward, chou (JP). Example: Manhattan." ::= { dot11APCivicLocationEntry 6 } dot11APCivicLocationA5 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the neighborhood, block. Example: Morningside Heights." ::= { dot11APCivicLocationEntry 7 } dot11APCivicLocationA6 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the street. Example: Broadway. The A6 element is retained for use in those countries that require this level of detail. Where A6 was previously used for street names in IETF RFC 5139 [B45], it will not be used, the RD element will be used for thoroughfare data. However, without additional information these fields will not be interchanged when converting between different civic formats. Where Civic address information is obtained from another format, such as the DHCP form IETF RFC 4776 [B43], the A6 element will be copied directly from the source format." ::= { dot11APCivicLocationEntry 8 } dot11APCivicLocationPrd OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the leading street direction. Example: NW." ::= { dot11APCivicLocationEntry 9 } dot11APCivicLocationPod OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the trailing street suffix. Example: SW." ::= { dot11APCivicLocationEntry 10 } dot11APCivicLocationSts OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the street suffix. Example: Avenue, 'Platz, Street'." ::= { dot11APCivicLocationEntry 11 } dot11APCivicLocationHno OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the numeric part only of the House number. Example: 123." ::= { dot11APCivicLocationEntry 12 } dot11APCivicLocationHns OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the house number suffix. Example: A, 1/2" ::= { dot11APCivicLocationEntry 13 } dot11APCivicLocationLmk OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the landmark or vanity address. Example: Low Library." ::= { dot11APCivicLocationEntry 14 } dot11APCivicLocationLoc OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains additional location information. Example: Room 543." ::= { dot11APCivicLocationEntry 15 } dot11APCivicLocationNam OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the name (residence, business, or office occupant. Example: Joe's Barbershop." ::= { dot11APCivicLocationEntry 16 } dot11APCivicLocationPc OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the postal code. Example: 10027-0401." ::= { dot11APCivicLocationEntry 17 } dot11APCivicLocationBld OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the building (structure). Example: Hope Theater." ::= { dot11APCivicLocationEntry 18 } dot11APCivicLocationUnit OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the unit (apartment, suite). Example: 12a." ::= { dot11APCivicLocationEntry 19 } dot11APCivicLocationFlr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the floor number. Example: 5." ::= { dot11APCivicLocationEntry 20 } dot11APCivicLocationRoom OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the room. Example: 450F." ::= { dot11APCivicLocationEntry 21 } dot11APCivicLocationPlc OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the place type. Example: office." ::= { dot11APCivicLocationEntry 22 } dot11APCivicLocationPcn OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the postal community name. Example: Leonia." ::= { dot11APCivicLocationEntry 23 } dot11APCivicLocationPobox OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the post office box (P.O. Box). Example: U40." ::= { dot11APCivicLocationEntry 24 } dot11APCivicLocationAddcode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the additional code. Example: 13203000003." ::= { dot11APCivicLocationEntry 25 } dot11APCivicLocationSeat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the seat (desk, cubicle, workstation). Example: WS 181." ::= { dot11APCivicLocationEntry 26 } dot11APCivicLocationRd OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the primary road or street. Example: Broadway." ::= { dot11APCivicLocationEntry 27 } dot11APCivicLocationRdsec OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the road section. Example: 14.In some countries a thoroughfare can be broken up into sections, and it is not uncommon for street numbers to be repeated between sections. A road section identifier might be needed to make that an address unique. For example, West Alice Parade has 5 sections, each numbered from 1; unless the section is specified 7 West Alice Parade could exist in 5 different places." ::= { dot11APCivicLocationEntry 28 } dot11APCivicLocationRdbr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the road branch. Example: 'Lane 7'. Minor streets can share the same name, so that they can only Be distinguished by the major thoroughfare with which they intersect. For example, both West Alice Parade, Section 3 and Bob Street could both be interested by a Carol Lane. This element is used to specify a road branch where the name of the branch does not uniquely identify the road. Road branches MAY also be used where a major thoroughfare is split into sections." ::= { dot11APCivicLocationEntry 29 } dot11APCivicLocationRdsubbr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the road sub-branch. Example: Alley 8." ::= { dot11APCivicLocationEntry 30 } dot11APCivicLocationPrm OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the road premodifier. Example: Old." ::= { dot11APCivicLocationEntry 31 } dot11APCivicLocationPom OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the road post-modifier. Example: Extended." ::= { dot11APCivicLocationEntry 32 } -- ********************************************************************** -- * End of dot11APCivicLocation TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11RoamingConsortium TABLE -- ********************************************************************** dot11RoamingConsortiumTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11RoamingConsortiumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a Table of OIs which are to be transmitted in an ANQP Roaming Consortium ANQP-element. Each table entry corresponds to a roaming consortium or single SSP. The first 3 entries in this table are transmitted in Beacon and Probe Response frames." ::= { dot11imt 5 } dot11RoamingConsortiumEntry OBJECT-TYPE SYNTAX Dot11RoamingConsortiumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each OI identifies a roaming consortium (group of SSPs with inter-SSP roaming agreement) or a single SSP. A non-AP STA in possession of security credentials for the SSPN(s) identified by the OI should be able to successfully authenticate to this AP." INDEX { dot11RoamingConsortiumOI } ::= { dot11RoamingConsortiumTable 1 } Dot11RoamingConsortiumEntry ::= SEQUENCE { dot11RoamingConsortiumOI OCTET STRING, dot11RoamingConsortiumRowStatus RowStatus } dot11RoamingConsortiumOI OBJECT-TYPE SYNTAX OCTET STRING (SIZE(16)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains the IEEE defined OI as defined in 9.4.1.31." ::= { dot11RoamingConsortiumEntry 1 } dot11RoamingConsortiumRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object represents the status column for a conceptual row in this table." ::= { dot11RoamingConsortiumEntry 2 } -- ********************************************************************** -- * End of dot11RoamingConsortium TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11DomainName TABLE -- ********************************************************************** dot11DomainNameTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11DomainNameEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table of Domain Names which form the Domain Name list in access network query protocol. The Domain Name list may be transmitted to a non-AP STA in a GAS Response. Each table entry corresponds to a single Domain Name." ::= { dot11imt 6 } dot11DomainNameEntry OBJECT-TYPE SYNTAX Dot11DomainNameEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. Each Domain Name identifies a domain names of the entity operating the IEEE 802.11 access network." INDEX { dot11DomainNameOui } ::= { dot11DomainNameTable 1 } Dot11DomainNameEntry ::= SEQUENCE { dot11DomainName OCTET STRING, dot11DomainNameRowStatus RowStatus, dot11DomainNameOui OCTET STRING } dot11DomainName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute contains a Domain Name of up to 255 octets formatted in accordance with the 'Preferred Name Syntax' as defined in IETF RFC 1035." ::= { dot11DomainNameEntry 1 } dot11DomainNameRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object represents the status column for a conceptual row in this table." ::= { dot11DomainNameEntry 2 } dot11DomainNameOui OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..5)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object represents an IEEE assigned unique identifier (OUI, OUI-36 or CID), used as an index into the Domain Name table." ::= { dot11DomainNameEntry 3 } -- ********************************************************************** -- * End of dot11DomainName TABLE -- ********************************************************************** -- ********************************************************************** -- * dot11GASAdvertisement TABLE -- ********************************************************************** dot11GASAdvertisementTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11GASAdvertisementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is a table of GAS counters that allows for multiple instantiations of those counters on a STA." ::= { dot11imt 7 } dot11GASAdvertisementEntry OBJECT-TYPE SYNTAX Dot11GASAdvertisementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object provides the attributes identifying a GAS counter within a STA." INDEX { dot11GASAdvertisementId } ::= { dot11GASAdvertisementTable 1 } Dot11GASAdvertisementEntry ::= SEQUENCE { dot11GASAdvertisementId Unsigned32, dot11GASPauseForServerResponse TruthValue, dot11GASResponseTimeout Unsigned32, dot11GASComebackDelay Unsigned32, dot11GASResponseBufferingTime Unsigned32, dot11GASQueryResponseLengthLimit Unsigned32, dot11GASQueries Counter32, dot11GASQueryRate Gauge32, dot11GASResponses Counter32, dot11GASResponseRate Gauge32, dot11GASNoRequestOutstanding Counter32, dot11GASResponsesDiscarded Counter32, dot11GASFailedResponses Counter32 } dot11GASAdvertisementId OBJECT-TYPE SYNTAX Unsigned32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The 1-octet identification number for the GAS advertisement protocol, as defined in Table 9-237, for which statistics are stored the logical row of the GASAdvertisement table." ::= { dot11GASAdvertisementEntry 1 } dot11GASPauseForServerResponse OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute is used only by the responding STA in a GAS exchange. When true, it indicates that the responding STA does not transmit a GAS Initial Response frame until it receives the query response from the Advertisement Server or a timeout occurs. When false, the STA does not wait for a response from the Advertisement Server before transmitting the GAS Initial Response frame. The setting of this MIB object is outside the scope of this standard." ::= { dot11GASAdvertisementEntry 2 } dot11GASResponseTimeout OBJECT-TYPE SYNTAX Unsigned32 (10..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This parameter shall indicate the GAS response timeout value." DEFVAL {50} ::= { dot11GASAdvertisementEntry 3 } dot11GASComebackDelay OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This object identifies the GAS Comeback Delay to be used for this advertisement protocol" DEFVAL {1000} ::= { dot11GASAdvertisementEntry 4 } dot11GASResponseBufferingTime OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This object defines the time after the expiration of the GAS comeback delay that a STA will buffer a Query Response. Upon expiration of this time, the STA may discard the Query Response." DEFVAL {1000} ::= { dot11GASAdvertisementEntry 5 } dot11GASQueryResponseLengthLimit OBJECT-TYPE SYNTAX Unsigned32 (1..127) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This object indicates the maximum number of octets an AP will transmit in one or more Query Response fields contained within GAS Comeback Response frame(s). A value of 127 means the maximum limit enforced is contained by the maximum allowable number of fragments in the GAS Query Fragment Response ID" ::= { dot11GASAdvertisementEntry 6 } dot11GASQueries OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after transmission of an MLME-GAS.request or receipt of an MLME-GAS.indication primitive. The number of GAS queries sent or received for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 7 } dot11GASQueryRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after receipt of an MLME-GAS.indication primitive. The number of GAS queries per minute received for the protocol identified by dot11GASAdvertisementId, averaged over the previous ten minutes." ::= { dot11GASAdvertisementEntry 8 } dot11GASResponses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after transmission of an MLME-GAS.response primitive or receipt of an MLME-GAS.confirm primitive. The number of GAS responses sent or received for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 9 } dot11GASResponseRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after transmission of an MLME-GAS.response primitive. The number of responses to GAS queries per minute transmitted by an AP for the protocol identified by dot11GASAdvertisementId, averaged over the previous ten minutes. This MIB attribute is not used in non-AP STAs." ::= { dot11GASAdvertisementEntry 10 } dot11GASNoRequestOutstanding OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after transmission of an MLME-GAS.response primitive. This counter shall be incremented each time a STA returns a status code of NO_OUTSTANDING_GAS_REQUEST in a GAS Initial Response or GAS Comeback Response frame for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 13 } dot11GASResponsesDiscarded OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after transmission of an MLME-GAS.response primitive. This counter shall be incremented each a STA discards a GAS response due to the expiration of the dot11GASResponseBufferingTime timer for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 14 } dot11GASFailedResponses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME after transmission of an MLME-GAS.response primitive. This counter shall be incremented each time a STA commences transmitting a GAS response but fails to successfully complete the transmission of all GAS fragments in that response due to the expiratin of the dot11GASResponseTimeout timer for the protocol identified by dot11GASAdvertisementId." ::= { dot11GASAdvertisementEntry 15 } -- ********************************************************************** -- * End of dot11GASAdvertisement TABLE -- ********************************************************************** -- ********************************************************************** -- * MAC state generic convergence function -- ********************************************************************** -- MAC state generic convergence function attributes -- DEFINED AS "The MAC state generic convergence function object -- class provides the necessary support for support of event-driven -- triggers to higher layer protocols and the capabilities to -- support those triggers." dot11MSGCF OBJECT IDENTIFIER ::= { ieee802dot11 7} -- MAC state generic convergence function GROUPS -- dot11MACStateConfigTable ::= { dot11MSGCF 1 } -- dot11MACStateParameterTable ::= { dot11MSGCF 2 } -- dot11MACStateESSLinkTable ::= { dot11MSGCF 3 } -- ********************************************************************* -- * dot11ESSLinkIdentifier type definition -- ********************************************************************* Dot11ESSLinkIdentifier ::= OCTET STRING (SIZE(0..38)) -- This object type holds the identifier for an IEEE 802.11 -- network. It is composed of the SSID string concatenated -- with the HESSID, if present. -- ********************************************************************* -- * dot11MACStateConfig TABLE -- ********************************************************************* dot11MACStateConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11MACStateConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table holds configuration parameters for the IEEE 802.11 MAC state generic convergence function." ::= { dot11MSGCF 1 } dot11MACStateConfigEntry OBJECT-TYPE SYNTAX Dot11MACStateConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represents a conceptual row in the dot11MACStateConfigTable and provides information about network configuration parameters used in the MAC state generic convergence function." INDEX { dot11MSCEESSLinkIdentifier, dot11MSCENonAPStationMacAddress } ::= { dot11MACStateConfigTable 1 } Dot11MACStateConfigEntry ::= SEQUENCE { dot11ESSDisconnectFilterInterval Unsigned32, dot11ESSLinkDetectionHoldInterval Unsigned32, dot11MSCEESSLinkIdentifier Dot11ESSLinkIdentifier, dot11MSCENonAPStationMacAddress MacAddress } dot11ESSDisconnectFilterInterval OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute is set to the time that will elapse after an MLME-DISASSOCIATE.confirm or MLME-DEAUTHENTICATE.confirm primitive without a subsequent association before the link is declared down. This interval is intended to allow a non-AP STA time to transition to another AP within the same ESS before declaring that the link to the ESS is lost." ::= { dot11MACStateConfigEntry 1 } dot11ESSLinkDetectionHoldInterval OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute is set to the time that an ESS is held in the dot11MACStateESSLink table after its last observation before purging the entry from the table." ::= { dot11MACStateConfigEntry 2 } dot11MSCEESSLinkIdentifier OBJECT-TYPE SYNTAX Dot11ESSLinkIdentifier MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an auxiliary variable used to identify instances of the columnar objects in the dot11MACStateConfigTable table." ::= { dot11MACStateConfigEntry 3 } dot11MSCENonAPStationMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an auxiliary variable used to identify instances of the columnar objects in the dot11MACStateConfigTable table." ::= { dot11MACStateConfigEntry 4 } -- ********************************************************************* -- * End of dot11MACStateConfig TABLE -- ********************************************************************* -- ********************************************************************* -- * dot11MACStateParameter TABLE -- ********************************************************************* dot11MACStateParameterTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11MACStateParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table holds the current parameters used for each IEEE 802.11 network for IEEE 802.11 MAC convergence functions." ::= { dot11MSGCF 2 } dot11MACStateParameterEntry OBJECT-TYPE SYNTAX Dot11MACStateParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represents a conceptual row in the dot11MACStateParameterTable and provides information about link configuration parameters used in the MAC state generic convergence function." INDEX { dot11MSPEESSLinkIdentifier, dot11MSPENonAPStationMacAddress } ::= { dot11MACStateParameterTable 1 } Dot11MACStateParameterEntry ::= SEQUENCE { dot11ESSLinkDownTimeInterval Unsigned32, dot11ESSLinkRssiDataThreshold Unsigned32, dot11ESSLinkRssiBeaconThreshold Unsigned32, dot11ESSLinkDataSnrThreshold Unsigned32, dot11ESSLinkBeaconSnrThreshold Unsigned32, dot11ESSLinkBeaconFrameErrorRateThresholdInteger Unsigned32, dot11ESSLinkBeaconFrameErrorRateThresholdFraction Unsigned32, dot11ESSLinkBeaconFrameErrorRateThresholdExponent Unsigned32, dot11ESSLinkFrameErrorRateThresholdInteger Unsigned32, dot11ESSLinkFrameErrorRateThresholdFraction Unsigned32, dot11ESSLinkFrameErrorRateThresholdExponent Unsigned32, dot11PeakOperationalRate Unsigned32, dot11MinimumOperationalRate Unsigned32, dot11ESSLinkDataThroughputInteger Unsigned32, dot11ESSLinkDataThroughputFraction Unsigned32, dot11ESSLinkDataThroughputExponent Unsigned32, dot11MSPEESSLinkIdentifier Dot11ESSLinkIdentifier, dot11MSPENonAPStationMacAddress MacAddress } dot11ESSLinkDownTimeInterval OBJECT-TYPE SYNTAX Unsigned32 UNITS "TUs" MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute defines the time interval over which the MAC state generic convergence function will attempt to predict the failure of an IEEE 802.11 network. The convergence function should issue predicted network failure events at least this time interval before the network failure is detected." ::= { dot11MACStateParameterEntry 2 } dot11ESSLinkRssiDataThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute defines the threshold value for RSSI on Data frames. When the RSSI drops below this threshold, a report is issued." ::= { dot11MACStateParameterEntry 3 } dot11ESSLinkRssiBeaconThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute defines the threshold value for RSSI on Beacon frames. When the RSSI drops below this threshold, a report is issued." ::= { dot11MACStateParameterEntry 4 } dot11ESSLinkBeaconSnrThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute defines the threshold value for SNR on received Beacon frames. When the SNR drops below this threshold, a report is issued" ::= { dot11MACStateParameterEntry 5 } dot11ESSLinkDataSnrThreshold OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. This attribute defines the threshold value for SNR on received Data frames. When the SNR drops below this threshold, a report is issued." ::= { dot11MACStateParameterEntry 6 } dot11ESSLinkBeaconFrameErrorRateThresholdInteger OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The Beacon frame error rate is stored in scientific notation as a significant and exponent. This attribute contains the integer value of the significand." ::= { dot11MACStateParameterEntry 7 } dot11ESSLinkBeaconFrameErrorRateThresholdFraction OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The Beacon frame error rate is stored in scientific notation as a significant and exponent. This attribute contains the fractional value of the significand." ::= { dot11MACStateParameterEntry 8 } dot11ESSLinkBeaconFrameErrorRateThresholdExponent OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The Beacon frame error rate is stored in scientific notation as a significant and exponent. This attribute contains the integer value of the exponent." ::= { dot11MACStateParameterEntry 9 } dot11ESSLinkFrameErrorRateThresholdInteger OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The frame error rate of the network is stored in scientific notation as a significant and exponent. This attribute contains the integer value of the significand." ::= { dot11MACStateParameterEntry 10 } dot11ESSLinkFrameErrorRateThresholdFraction OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The frame error rate of the network is stored in scientific notation as a significant and exponent. This attribute contains the fractional value of the significand." ::= { dot11MACStateParameterEntry 11 } dot11ESSLinkFrameErrorRateThresholdExponent OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The frame error rate of the network is stored in scientific notation as a significant and exponent. This attribute contains the integer value of the exponent." ::= { dot11MACStateParameterEntry 12 } dot11PeakOperationalRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The highest operational rate used for transmission of Data frames, encoded as defined in 9.4.2.3." ::= { dot11MACStateParameterEntry 13 } dot11MinimumOperationalRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The lowest operational rate used for transmission of Data frames, encoded as defined in 9.4.2.3." ::= { dot11MACStateParameterEntry 14 } dot11ESSLinkDataThroughputInteger OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The data throughput rate is of the network is stored in scientific notation as a significant and exponent. This attribute contains the integer value of the significand." ::= { dot11MACStateParameterEntry 15 } dot11ESSLinkDataThroughputFraction OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The data throughput rate is of the network is stored in scientific notation as a significant and exponent. This attribute contains the fractional value of the significand." ::= { dot11MACStateParameterEntry 16 } dot11ESSLinkDataThroughputExponent OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity or the SME. Changes take effect as soon as practical in the implementation. The data throughput rate is of the network is stored in scientific notation as a significant and exponent. This attribute contains the integer value of the exponent." ::= { dot11MACStateParameterEntry 17 } dot11MSPEESSLinkIdentifier OBJECT-TYPE SYNTAX Dot11ESSLinkIdentifier MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an auxiliary variable used to identify instances of the columnar objects in the dot11MACStateParameterTable table." ::= { dot11MACStateParameterEntry 18 } dot11MSPENonAPStationMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an auxiliary variable used to identify instances of the columnar objects in the dot11MACStateParameterTable table." ::= { dot11MACStateParameterEntry 19 } -- ********************************************************************* -- * End of dot11MACStateParameter TABLE -- ********************************************************************* -- ********************************************************************* -- * dot11MACStateESSLink TABLE -- ********************************************************************* dot11MACStateESSLinkDetectedTable OBJECT-TYPE SYNTAX SEQUENCE OF Dot11MACStateESSLinkDetectedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table holds the detected IEEE 802.11 network list used for MAC convergence functions." ::= { dot11MSGCF 3 } dot11MACStateESSLinkDetectedEntry OBJECT-TYPE SYNTAX Dot11MACStateESSLinkDetectedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry represents a conceptual row in the dot11MACStateESSLinkTable and provides information about available networks for use in the MAC state generic convergence function." INDEX { dot11MSELDEESSLinkIdentifier, dot11MSELDENonAPStationMacAddress } ::= { dot11MACStateESSLinkDetectedTable 1 } Dot11MACStateESSLinkDetectedEntry ::= SEQUENCE { dot11ESSLinkDetectedIndex Unsigned32, dot11ESSLinkDetectedNetworkId OCTET STRING, dot11ESSLinkDetectedNetworkDetectTime Unsigned32, dot11ESSLinkDetectedNetworkModifiedTime Unsigned32, dot11ESSLinkDetectedNetworkMISCapabilities BITS, dot11MSELDEESSLinkIdentifier Dot11ESSLinkIdentifier, dot11MSELDENonAPStationMacAddress MacAddress } dot11ESSLinkDetectedIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index for ESSLinkDetected elements in dot11ESSLinkDetectedTable, greater than 0." ::= { dot11MACStateESSLinkDetectedEntry 1 } dot11ESSLinkDetectedNetworkId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MSGCF after reception of an MSGCF-ESS-LINK-DETECTED.indication primitive. The string used to identify the network represented by this row in the table. It is composed of the SSID of the network concatenated with the HESSID, if present." ::= { dot11MACStateESSLinkDetectedEntry 2 } dot11ESSLinkDetectedNetworkDetectTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MSGCF after reception of an MSGCF-ESS-LINK-DETECTED.indication primitive. The STA's TSF timer when any BSSID supporting the network was first detected." ::= { dot11MACStateESSLinkDetectedEntry 4 } dot11ESSLinkDetectedNetworkModifiedTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MSGCF after reception of an MSGCF-ESS-LINK-DETECTED.indication primitive. The STA's TSF timer value when changes were made to any part of this row in the table, such as by addition of a BSSID to the BSSID list." ::= { dot11MACStateESSLinkDetectedEntry 5 } dot11ESSLinkDetectedNetworkMISCapabilities OBJECT-TYPE SYNTAX BITS { misIsSupport(0), misCsEsSupport(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the MSGCF after reception of an MSGCF-ESS-LINK-DETECTED.indication primitive. The object reports whether the network supports IEEE 802.21 MIS information services and/or IEEE 802.21 MIS command/event services. These values are determined by examining the Interworking information in frames that caused the network to be detected." ::= { dot11MACStateESSLinkDetectedEntry 6 } dot11MSELDEESSLinkIdentifier OBJECT-TYPE SYNTAX Dot11ESSLinkIdentifier MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an auxiliary variable used to identify instances of the columnar objects in the dot11MACStateESSLinkDetectedTable table." ::= { dot11MACStateESSLinkDetectedEntry 7 } dot11MSELDENonAPStationMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an auxiliary variable used to identify instances of the columnar objects in the dot11MACStateESSLinkDetectedTable table." ::= { dot11MACStateESSLinkDetectedEntry 8 } -- ********************************************************************* -- * End of dot11MACStateESSLink TABLE -- ********************************************************************* -- ********************************************************************** -- * Compliance Information -- ********************************************************************** dot11Conformance OBJECT IDENTIFIER ::= { ieee802dot11 5 } dot11Groups OBJECT IDENTIFIER ::= { dot11Conformance 1 } dot11Compliances OBJECT IDENTIFIER ::= { dot11Conformance 2 } -- ********************************************************************** -- * Groups - units of compliance -- ********************************************************************** dot11SMTbase OBJECT-GROUP OBJECTS { dot11StationID, dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase2. The SMT object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network." ::= { dot11Groups 1 } dot11SMTprivacy OBJECT-GROUP OBJECTS { dot11PrivacyInvoked, dot11WEPKeyMappingLengthImplemented, dot11ExcludeUnencrypted, dot11WEPICVErrorCount, dot11WEPExcludedCount, dot11WEPDefaultKeyID, dot11WEPDefaultKeyValue, dot11WEPKeyMappingWEPOn, dot11WEPKeyMappingValue, dot11WEPKeyMappingAddress, dot11WEPKeyMappingStatus } STATUS current DESCRIPTION "The SMTPrivacy package is a set of attributes that are present if WEP is implemented in the STA." ::= { dot11Groups 2 } dot11MACbase OBJECT-GROUP OBJECTS { dot11MACAddress, dot11GroupAddress, dot11GroupAddressesStatus, dot11RTSThreshold, dot11ShortRetryLimit, dot11LongRetryLimit, dot11FragmentationThreshold, dot11MaxTransmitMSDULifetime, dot11MaxReceiveLifetime, dot11ManufacturerID, dot11ProductID } STATUS deprecated DESCRIPTION "Superseded by dot11MACbase2. The MAC object class provides the necessary support for the access control, generation, and verification of frame check sequences (FCSs), and proper delivery of valid data to upper layers." ::= { dot11Groups 3 } dot11MACStatistics OBJECT-GROUP OBJECTS { dot11RetryCount, dot11MultipleRetryCount, dot11RTSSuccessCount, dot11RTSFailureCount, dot11AckFailureCount, dot11FrameDuplicateCount } STATUS current DESCRIPTION "The MACStatistics package provides extended statistical information on the operation of the MAC. This package is completely optional." ::= { dot11Groups 4 } dot11ResourceTypeID OBJECT-GROUP OBJECTS { dot11ResourceTypeIDName, dot11manufacturerOUI, dot11manufacturerName, dot11manufacturerProductName, dot11manufacturerProductVersion } STATUS current DESCRIPTION "Attributes used to identify a STA, its manufacturer, and various product names and versions." ::= { dot11Groups 5 } dot11SmtAuthenticationAlgorithms OBJECT-GROUP OBJECTS { dot11AuthenticationAlgorithm, dot11AuthenticationAlgorithmActivated } STATUS current DESCRIPTION "Authentication Algorithm Table." ::= { dot11Groups 6 } dot11PhyOperationComplianceGroup OBJECT-GROUP OBJECTS { dot11PHYType, dot11CurrentRegDomain, dot11TempType } STATUS deprecated DESCRIPTION "Superseded by dot11PhyOperationComplianceGroup2. PHY operations attributes." ::= { dot11Groups 7 } dot11PhyAntennaComplianceGroup OBJECT-GROUP OBJECTS { dot11CurrentTxAntenna, dot11DiversitySupportImplemented, dot11CurrentRxAntenna } STATUS deprecated DESCRIPTION "Attributes for Data Rates for IEEE Std 802.11." ::= { dot11Groups 8 } dot11PhyTxPowerComplianceGroup OBJECT-GROUP OBJECTS { dot11NumberSupportedPowerLevelsImplemented, dot11TxPowerLevel1, dot11TxPowerLevel2, dot11TxPowerLevel3, dot11TxPowerLevel4, dot11TxPowerLevel5, dot11TxPowerLevel6, dot11TxPowerLevel7, dot11TxPowerLevel8, dot11CurrentTxPowerLevel } STATUS current DESCRIPTION "Attributes for Control and Management of transmit power." ::= { dot11Groups 9 } dot11PhyDSSSComplianceGroup OBJECT-GROUP OBJECTS { dot11CurrentChannel, dot11CCAModeSupported, dot11CurrentCCAMode, dot11EDThreshold } STATUS current DESCRIPTION "Attributes that configure the DSSS PHY for IEEE Std 802.11." ::= { dot11Groups 11 } dot11PhyRegDomainsSupportGroup OBJECT-GROUP OBJECTS { dot11RegDomainsImplementedValue } STATUS deprecated DESCRIPTION "Attributes that specify the supported Regulation Domains." ::= { dot11Groups 13 } dot11PhyAntennasListGroup OBJECT-GROUP OBJECTS { dot11TxAntennaImplemented, dot11RxAntennaImplemented, dot11DiversitySelectionRxImplemented } STATUS current DESCRIPTION "Attributes that specify the supported Regulation Domains." ::= { dot11Groups 14 } dot11PhyRateGroup OBJECT-GROUP OBJECTS { dot11ImplementedDataRatesTxValue, dot11ImplementedDataRatesRxValue } STATUS current DESCRIPTION "Attributes for Data Rates for IEEE Std 802.11." ::= { dot11Groups 15 } dot11CountersGroup OBJECT-GROUP OBJECTS { dot11TransmittedFragmentCount, dot11GroupTransmittedFrameCount, dot11FailedCount, dot11ReceivedFragmentCount, dot11GroupReceivedFrameCount, dot11FCSErrorCount, dot11WEPUndecryptableCount, dot11TransmittedFrameCount } STATUS deprecated DESCRIPTION "Superseded by dot11CountersGroup2. Attributes from the dot11CountersGroup that are not described in the dot11MACStatistics group. These objects are mandatory." ::= { dot11Groups 16 } dot11NotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { dot11Disassociate, dot11Deauthenticate, dot11AuthenticateFail, dot11Associate, dot11AssociateFailed, dot11Reassociate, dot11ReassociateFailed } STATUS current DESCRIPTION "IEEE 802.11 notifications" ::= { dot11Groups 17 } dot11SMTbase2 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase3. The SMTbase2 object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network." ::= { dot11Groups 18 } dot11PhyOFDMComplianceGroup OBJECT-GROUP OBJECTS { dot11CurrentFrequency, dot11TIThreshold, dot11FrequencyBandsImplemented, dot11ChannelStartingFactor } STATUS deprecated DESCRIPTION "Superseded by dot11PhyOFDMComplianceGroup2. Attributes that configure the OFDM PHY for IEEE Std 802.11." ::= { dot11Groups 19 } dot11SMTbase3 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase4. The SMTbase3 object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network, when the STA is capable of multidomain operation. This object group should be implemented when the multidomain capability option is implemented." ::= { dot11Groups 20 } dot11MultiDomainCapabilityGroup OBJECT-GROUP OBJECTS { dot11FirstChannelNumber, dot11NumberofChannels, dot11MaximumTransmitPowerLevel } STATUS current DESCRIPTION "The dot11MultiDomainCapabilityGroup object class provides the objects necessary to manage the channels usable by a STA, when the multidomain capability option is implemented." ::= { dot11Groups 21 } dot11PhyHRDSSSComplianceGroup OBJECT-GROUP OBJECTS { dot11CurrentChannel, dot11CCAModeSupported, dot11CurrentCCAMode, dot11EDThreshold, dot11ShortPreambleOptionImplemented, dot11HRCCAModeImplemented } STATUS current DESCRIPTION "Attributes that configure the HRDSSS PHY for IEEE Std 802.11." ::= { dot11Groups 23 } dot11PhyERPComplianceGroup OBJECT-GROUP OBJECTS { dot11CurrentChannel, dot11ShortPreambleOptionImplemented, dot11ShortSlotTimeOptionImplemented, dot11ShortSlotTimeOptionActivated } STATUS current DESCRIPTION "Attributes that configure the ERP." ::= { dot11Groups 24 } dot11RSNAadditions OBJECT-GROUP OBJECTS { dot11RSNAActivated, dot11RSNAPreauthenticationActivated } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage RSNA functionality. Note that additional objects for managing this functionality are located in the IEEE 802.11 RSN MIB." ::= { dot11Groups 25 } dot11SMTbase4 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11RSNAOptionImplemented } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase5. The SMTbase4 object class provides the necessary support at the IEEE STA to manage the processes in the STA so that the STA may work cooperatively as a part of an IEEE 802.11 network." ::= { dot11Groups 26 } -- ******************************************************************** -- * Groups - units of compliance - RSN -- ******************************************************************** dot11RSNBase OBJECT-GROUP OBJECTS { dot11RSNAConfigVersion, dot11RSNAConfigPairwiseKeysImplemented, dot11RSNAConfigGroupCipher, dot11RSNAConfigGroupRekeyMethod, dot11RSNAConfigGroupRekeyTime, dot11RSNAConfigGroupRekeyPackets, dot11RSNAConfigGroupRekeyStrict, dot11RSNAConfigPSKValue, dot11RSNAConfigPSKPassPhrase, dot11RSNAConfigGroupUpdateCount, dot11RSNAConfigPairwiseUpdateCount, dot11RSNAConfigGroupCipherSize, dot11RSNAConfigPairwiseCipherImplemented, dot11RSNAConfigPairwiseCipherActivated, dot11RSNAConfigPairwiseCipherSizeImplemented, dot11RSNAConfigAuthenticationSuiteImplemented, dot11RSNAConfigAuthenticationSuiteActivated, dot11RSNAConfigNumberOfPTKSAReplayCounters, dot11RSNAConfigSATimeout, dot11RSNAConfigNumberOfGTKSAReplayCounters, dot11RSNAAuthenticationSuiteSelected, dot11RSNAPairwiseCipherSelected, dot11RSNAGroupCipherSelected, dot11RSNAPMKIDUsed, dot11RSNAAuthenticationSuiteRequested, dot11RSNAPairwiseCipherRequested, dot11RSNAGroupCipherRequested, dot11RSNATKIPCounterMeasuresInvoked, dot11RSNA4WayHandshakeFailures, dot11RSNAStatsSTAAddress, dot11RSNAStatsVersion, dot11RSNAStatsSelectedPairwiseCipher, dot11RSNAStatsTKIPICVErrors, dot11RSNAStatsTKIPLocalMICFailures, dot11RSNAStatsTKIPRemoteMICFailures, dot11RSNAStatsCCMPReplays, dot11RSNAStatsCCMPDecryptErrors, dot11RSNAStatsTKIPReplays, dot11RSNAConfigSTKKeysImplemented, dot11RSNAConfigSTKCipher, dot11RSNAConfigSTKRekeyTime, dot11RSNAConfigSMKUpdateCount, dot11RSNAConfigSTKCipherSize, dot11RSNAConfigNumberOfSTKSAReplayCounters, dot11RSNAPairwiseSTKSelected, dot11RSNAPreauthenticationImplemented, dot11RSNASMKHandshakeFailures } STATUS deprecated DESCRIPTION "Superseded by dot11RSNBase2.The dot11RSNBase object class provides the necessary support for managing RSNA functionality in the STA." ::= { dot11Groups 27 } dot11RSNPMKcachingGroup OBJECT-GROUP OBJECTS { dot11RSNAConfigPMKLifetime, dot11RSNAConfigPMKReauthThreshold } STATUS current DESCRIPTION "The dot11RSNPMKcachingGroup object class provides the necessary support for managing PMKSA caching functionality in the STA." ::= { dot11Groups 28 } dot11RSNSMKcachingGroup OBJECT-GROUP OBJECTS { dot11RSNAConfigSMKLifetime, dot11RSNAConfigSMKReauthThreshold } STATUS deprecated DESCRIPTION "Deprecated because mechanisms for use of cached SMKSAs are not defined. The dot11RSNSMKcachingGroup object class provides the necessary support for managing SMKSA caching functionality in the STA." ::= { dot11Groups 29 } dot11SMTbase5 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11SpectrumManagementImplemented, dot11SpectrumManagementRequired, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase6. The SMTbase5 object class provides the necessary support at the STA to manage the processes in the STA so that the STA may work cooperatively as a part of an IEEE 802.11 network, when the STA is capable of multidomain operation. This object group should be implemented when the multidomain capability option is implemented." ::= { dot11Groups 30 } dot11MACbase2 OBJECT-GROUP OBJECTS { dot11MACAddress, dot11GroupAddress, dot11GroupAddressesStatus, dot11RTSThreshold, dot11ShortRetryLimit, dot11LongRetryLimit, dot11FragmentationThreshold, dot11MaxTransmitMSDULifetime, dot11MaxReceiveLifetime, dot11ManufacturerID, dot11ProductID, dot11CAPLimit, dot11HCCWmin, dot11HCCWmax, dot11HCCAIFSN, dot11ADDBAResponseTimeout, dot11ADDTSResponseTimeout, dot11ChannelUtilizationBeaconIntervals, dot11ScheduleTimeout, dot11DLSResponseTimeout, dot11QAPMissingAckRetryLimit, dot11EDCAAveragingPeriod } STATUS deprecated DESCRIPTION "Superseded by dot11MACbase3. The MAC object class provides the necessary support for the access control, generation, and verification of frame check sequences (FCSs), and proper delivery of valid data to upper layers." ::= { dot11Groups 31 } dot11CountersGroup2 OBJECT-GROUP OBJECTS { dot11TransmittedFragmentCount, dot11GroupTransmittedFrameCount, dot11FailedCount, dot11ReceivedFragmentCount, dot11GroupReceivedFrameCount, dot11FCSErrorCount, dot11WEPUndecryptableCount, dot11TransmittedFrameCount, dot11QosDiscardedFragmentCount, dot11AssociatedStationCount, dot11QosCFPollsReceivedCount, dot11QosCFPollsUnusedCount, dot11QosCFPollsUnusableCount } STATUS deprecated DESCRIPTION "Superseded by dot11CountersGroup3. Attributes from the dot11CountersGroup that are not described in the dot11MACStatistics group. These objects are mandatory." ::= { dot11Groups 32 } dot11Qosadditions OBJECT-GROUP OBJECTS { -- dot11EDCATable, dot11EDCATableCWmin, dot11EDCATableCWmax, dot11EDCATableAIFSN, dot11EDCATableTXOPLimit, dot11EDCATableMSDULifetime, dot11EDCATableMandatory, -- dot11QAPEDCATable, dot11QAPEDCATableCWmin, dot11QAPEDCATableCWmax, dot11QAPEDCATableAIFSN, dot11QAPEDCATableTXOPLimit, dot11QAPEDCATableMSDULifetime, dot11QAPEDCATableMandatory, -- dot11QosCountersTable dot11QosTransmittedFragmentCount, dot11QosFailedCount, dot11QosRetryCount, dot11QosMultipleRetryCount, dot11QosFrameDuplicateCount, dot11QosRTSSuccessCount, dot11QosRTSFailureCount, dot11QosAckFailureCount, dot11QosReceivedFragmentCount, dot11QosTransmittedFrameCount, dot11QosDiscardedFrameCount, dot11QosMPDUsReceivedCount, dot11QosRetriesReceivedCount } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage QoS functionality." ::= { dot11Groups 33 } dot11SMTbase6 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired, dot11QosOptionImplemented, dot11ImmediateBlockAckOptionImplemented, dot11DelayedBlockAckOptionImplemented, dot11DirectOptionImplemented, dot11APSDOptionImplemented, dot11QAckOptionImplemented, dot11QBSSLoadImplemented, dot11QueueRequestOptionImplemented, dot11TXOPRequestOptionImplemented, dot11MoreDataAckOptionImplemented, dot11AssociateInNQBSS, dot11DLSAllowedInQBSS, dot11DLSAllowed } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase7. The SMTbase6 object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network." ::= { dot11Groups 34 } dot11PhyOFDMComplianceGroup2 OBJECT-GROUP OBJECTS { dot11CurrentFrequency, dot11TIThreshold, dot11FrequencyBandsImplemented, dot11ChannelStartingFactor, dot11FiveMHzOperationImplemented, dot11TenMHzOperationImplemented, dot11TwentyMHzOperationImplemented, dot11PhyOFDMChannelWidth } STATUS deprecated DESCRIPTION "Superseded by dot11PhyOFDMComplianceGroup3. Attributes that configure the OFDM PHY for IEEE Std 802.11." ::= { dot11Groups 35} dot11SMTbase7 OBJECT-GROUP OBJECTS{ dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11SpectrumManagementImplemented, dot11SpectrumManagementRequired, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired, dot11QosOptionImplemented, dot11ImmediateBlockAckOptionImplemented, dot11DelayedBlockAckOptionImplemented, dot11DirectOptionImplemented, dot11APSDOptionImplemented, dot11QAckOptionImplemented, dot11QBSSLoadImplemented, dot11QueueRequestOptionImplemented, dot11TXOPRequestOptionImplemented, dot11MoreDataAckOptionImplemented, dot11AssociateInNQBSS, dot11DLSAllowedInQBSS, dot11DLSAllowed, dot11AssociateStation, dot11AssociateID, dot11AssociateFailStation, dot11AssociateFailStatus, dot11ReassociateStation, dot11ReassociateID, dot11ReassociateFailStation, dot11ReassociateFailStatus, dot11RadioMeasurementImplemented, dot11RadioMeasurementActivated, dot11RMMeasurementNavSync, dot11RMMeasurementPilotPeriod, dot11RMLinkMeasurementActivated, dot11RMNeighborReportActivated, dot11RMParallelMeasurementsActivated, dot11RMRepeatedMeasurementsActivated, dot11RMBeaconPassiveMeasurementActivated, dot11RMBeaconActiveMeasurementActivated, dot11RMBeaconTableMeasurementActivated, dot11RMBeaconMeasurementReportingConditionsActivated, dot11RMFrameMeasurementActivated, dot11RMChannelLoadMeasurementActivated, dot11RMNoiseHistogramMeasurementActivated, dot11RMStatisticsMeasurementActivated, dot11RMLCIMeasurementActivated, dot11RMLCIAzimuthActivated, dot11RMTransmitStreamCategoryMeasurementActivated, dot11RMTriggeredTransmitStreamCategoryMeasurementActivated, dot11RMAPChannelReportActivated, dot11RMMIBActivated, dot11RMMaxMeasurementDuration, dot11RMNonOperatingChannelMaxMeasurementDuration, dot11RMMeasurementPilotTransmissionInformationActivated, dot11RMMeasurementPilotActivated, dot11RMNeighborReportTSFOffsetActivated, dot11RMRCPIMeasurementActivated, dot11RMRSNIMeasurementActivated, dot11RMBSSAverageAccessDelayActivated, dot11RMBSSAvailableAdmissionCapacityActivated, dot11RMAntennaInformationActivated} STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase8. The SMTbase7 object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network, when the STA is capable of multidomain operation. This object group should be implemented when the multidomain capability option is implemented." ::= { dot11Groups 36 } dot11SMTRMRequest OBJECT-GROUP OBJECTS { dot11RMRqstRowStatus, dot11RMRqstToken, dot11RMRqstRepetitions, dot11RMRqstIfIndex, dot11RMRqstType, dot11RMRqstTargetAdd, dot11RMRqstTimeStamp, dot11RMRqstChanNumber, dot11RMRqstOperatingClass, dot11RMRqstRndInterval, dot11RMRqstDuration, dot11RMRqstParallel, dot11RMRqstEnable, dot11RMRqstRequest, dot11RMRqstReport, dot11RMRqstDurationMandatory, dot11RMRqstBeaconRqstMode, dot11RMRqstBeaconRqstDetail, dot11RMRqstFrameRqstType, dot11RMRqstBssid, dot11RMRqstSSID, dot11RMRqstBeaconReportingCondition, dot11RMRqstBeaconThresholdOffset, dot11RMRqstSTAStatRqstGroupID, dot11RMRqstLCIRqstSubject, dot11RMRqstLCIAzimuthType, dot11RMRqstLCIAzimuthResolution, dot11RMRqstPauseTime, dot11RMRqstTransmitStreamPeerQSTAAddress, dot11RMRqstTransmitStreamTrafficIdentifier, dot11RMRqstTransmitStreamBin0Range, dot11RMRqstTrigdQoSAverageCondition, dot11RMRqstTrigdQoSConsecutiveCondition, dot11RMRqstTrigdQoSDelayCondition, dot11RMRqstTrigdQoSAverageThreshold, dot11RMRqstTrigdQoSConsecutiveThreshold, dot11RMRqstTrigdQoSDelayThresholdRange, dot11RMRqstTrigdQoSDelayThreshold, dot11RMRqstTrigdQoSMeasurementCount, dot11RMRqstTrigdQoSTimeout, dot11RMRqstChannelLoadReportingCondition, dot11RMRqstChannelLoadReference, dot11RMRqstNoiseHistogramReportingCondition, dot11RMRqstAnpiReference, dot11RMRqstAPChannelReport, dot11RMRqstSTAStatPeerSTAAddress, dot11RMRqstFrameTransmitterAddress, dot11RMRqstVendorSpecific } STATUS current DESCRIPTION "The SMTRMRequest package is a set of attributes that are present if the STA supports the Radio Measurement service." ::= { dot11Groups 37 } dot11SMTRMReport OBJECT-GROUP OBJECTS { dot11ChannelLoadRprtRqstToken, dot11ChannelLoadRprtIfIndex, dot11ChannelLoadMeasuringSTAAddr, dot11ChannelLoadRprtChanNumber, dot11ChannelLoadRprtOperatingClass, dot11ChannelLoadRprtActualStartTime, dot11ChannelLoadRprtMeasurementDuration, dot11ChannelLoadRprtChannelLoad, dot11ChannelLoadRprtVendorSpecific, dot11ChannelLoadRprtMeasurementMode, dot11NoiseHistogramRprtRqstToken, dot11NoiseHistogramRprtIfIndex, dot11NoiseHistogramMeasuringSTAAddr, dot11NoiseHistogramRprtChanNumber, dot11NoiseHistogramRprtOperatingClass, dot11NoiseHistogramRprtActualStartTime, dot11NoiseHistogramRprtMeasurementDuration, dot11NoiseHistogramRprtAntennaID, dot11NoiseHistogramRprtANPI, dot11NoiseHistogramRprtIPIDensity0, dot11NoiseHistogramRprtIPIDensity1, dot11NoiseHistogramRprtIPIDensity2, dot11NoiseHistogramRprtIPIDensity3, dot11NoiseHistogramRprtIPIDensity4, dot11NoiseHistogramRprtIPIDensity5, dot11NoiseHistogramRprtIPIDensity6, dot11NoiseHistogramRprtIPIDensity7, dot11NoiseHistogramRprtIPIDensity8, dot11NoiseHistogramRprtIPIDensity9, dot11NoiseHistogramRprtIPIDensity10, dot11NoiseHistogramRprtVendorSpecific, dot11NoiseHistogramRprtMeasurementMode, dot11BeaconRprtRqstToken, dot11BeaconRprtIfIndex, dot11BeaconMeasuringSTAAddr, dot11BeaconRprtChanNumber, dot11BeaconRprtOperatingClass, dot11BeaconRprtActualStartTime, dot11BeaconRprtMeasurementDuration, dot11BeaconRprtPhyType, dot11BeaconRprtReportedFrameType, dot11BeaconRprtRCPI, dot11BeaconRprtRSNI, dot11BeaconRprtBSSID, dot11BeaconRprtAntennaID, dot11BeaconRprtParentTSF, dot11BeaconRprtReportedFrameBody, dot11BeaconRprtVendorSpecific, dot11BeaconRprtMeasurementMode, dot11FrameRprtIfIndex, dot11FrameRprtRqstToken, dot11FrameRprtChanNumber, dot11FrameRprtOperatingClass, dot11FrameRprtActualStartTime, dot11FrameRprtMeasurementDuration, dot11FrameRprtTransmitSTAAddress, dot11FrameRprtBSSID, dot11FrameRprtPhyType, dot11FrameRprtAvgRCPI, dot11FrameRprtLastRSNI, dot11FrameRprtLastRCPI, dot11FrameRprtAntennaID, dot11FrameRprtNumberFrames, dot11FrameRprtVendorSpecific, dot11FrameRptMeasurementMode, dot11STAStatisticsReportToken, dot11STAStatisticsIfIndex, dot11STAStatisticsSTAAddress, dot11STAStatisticsMeasurementDuration, dot11STAStatisticsGroupID, dot11STAStatisticsTransmittedFragmentCount, dot11STAStatisticsGroupTransmittedFrameCount, dot11STAStatisticsFailedCount, dot11STAStatisticsRetryCount, dot11STAStatisticsMultipleRetryCount, dot11STAStatisticsFrameDuplicateCount, dot11STAStatisticsRTSSuccessCount, dot11STAStatisticsRTSFailureCount, dot11STAStatisticsAckFailureCount, dot11STAStatisticsQosTransmittedFragmentCount, dot11STAStatisticsQosFailedCount, dot11STAStatisticsQosRetryCount, dot11STAStatisticsQosMultipleRetryCount, dot11STAStatisticsQosFrameDuplicateCount, dot11STAStatisticsQosRTSSuccessCount, dot11STAStatisticsQosRTSFailureCount, dot11STAStatisticsQosAckFailureCount, dot11STAStatisticsQosReceivedFragmentCount, dot11STAStatisticsQosTransmittedFrameCount, dot11STAStatisticsQosDiscardedFrameCount, dot11STAStatisticsQosMPDUsReceivedCount, dot11STAStatisticsQosRetriesReceivedCount, dot11STAStatisticsReceivedFragmentCount, dot11STAStatisticsGroupReceivedFrameCount, dot11STAStatisticsFCSErrorCount, dot11STAStatisticsTransmittedFrameCount, dot11STAStatisticsAPAverageAccessDelay, dot11STAStatisticsAverageAccessDelayBestEffort, dot11STAStatisticsAverageAccessDelayBackground, dot11STAStatisticsAverageAccessDelayVideo, dot11STAStatisticsAverageAccessDelayVoice, dot11STAStatisticsStationCount, dot11STAStatisticsChannelUtilization, dot11STAStatisticsVendorSpecific, dot11STAStatisticsRprtMeasurementMode, dot11LCIReportToken, dot11LCIIfIndex, dot11LCISTAAddress, dot11LCILatitudeUncertainty, dot11LCILatitudeInteger, dot11LCILatitudeFraction, dot11LCILongitudeUncertainty, dot11LCILongitudeInteger, dot11LCILongitudeFraction, dot11LCIAltitudeType, dot11LCIAltitudeUncertainty, dot11LCIAltitude, dot11LCIDatum, dot11LCIAzimuthType, dot11LCIAzimuthResolution, dot11LCIAzimuth, dot11LCIVendorSpecific, dot11LCIRprtMeasurementMode, dot11TransmitStreamRprtRqstToken, dot11TransmitStreamRprtIfIndex, dot11TransmitStreamMeasuringSTAAddr, dot11TransmitStreamRprtActualStartTime, dot11TransmitStreamRprtMeasurementDuration, dot11TransmitStreamRprtPeerSTAAddress, dot11TransmitStreamRprtTID, dot11TransmitStreamRprtAverageQueueDelay, dot11TransmitStreamRprtAverageTransmitDelay, dot11TransmitStreamRprtTransmittedMSDUCount, dot11TransmitStreamRprtMSDUDiscardedCount, dot11TransmitStreamRprtMSDUFailedCount, dot11TransmitStreamRprtMultipleRetryCount, dot11TransmitStreamRprtCFPollsLostCount, dot11TransmitStreamRprtBin0Range, dot11TransmitStreamRprtDelayHistogram, dot11TransmitStreamRprtReason, dot11TransmitStreamRprtVendorSpecific, dot11TransmitStreamRprtMeasurementMode } STATUS deprecated DESCRIPTION "Superseded by dot11SMTRMReport2.The SMTRMReport package is a set of attributes that are present if the STA supports the Radio Measurement service." ::= { dot11Groups 38 } dot11SMTRMConfig OBJECT-GROUP OBJECTS { dot11APChannelReportIfIndex, dot11APChannelReportOperatingClass, dot11APChannelReportChannelList, dot11RMNeighborReportIfIndex, dot11RMNeighborReportBSSID, dot11RMNeighborReportAPReachability, dot11RMNeighborReportSecurity, dot11RMNeighborReportCapSpectrumMgmt, dot11RMNeighborReportCapQoS, dot11RMNeighborReportCapAPSD, dot11RMNeighborReportCapRM, dot11RMNeighborReportCapDelayBlockAck, dot11RMNeighborReportCapImmediateBlockAck, dot11RMNeighborReportKeyScope, dot11RMNeighborReportChannelNumber, dot11RMNeighborReportOperatingClass, dot11RMNeighborReportPhyType, dot11RMNeighborReportNeighborTSFInfo, dot11RMNeighborReportPilotInterval, dot11RMNeighborReportPilotMultipleBSSID, dot11RMNeighborReportRMEnabledCapabilities, dot11RMNeighborReportVendorSpecific, dot11RMNeighborReportRowStatus, dot11RMNeighborReportCapHT, dot11RMNeighborReportHTLDPCCodingCap, dot11RMNeighborReportHTSupportedChannelWidthSet, dot11RMNeighborReportHTSMPowerSave, dot11RMNeighborReportHTGreenfield, dot11RMNeighborReportHTShortGIfor20MHz, dot11RMNeighborReportHTShortGIfor40MHz, dot11RMNeighborReportHTTxSTBC, dot11RMNeighborReportHTRxSTBC, dot11RMNeighborReportHTDelayedBlockAck, dot11RMNeighborReportHTMaxAMSDULength, dot11RMNeighborReportHTDSSCCKModein40MHz, dot11RMNeighborReportHTFortyMHzIntolerant, dot11RMNeighborReportHTLSIGTXOPProtectionSupport, dot11RMNeighborReportHTMaxAMPDULengthExponent, dot11RMNeighborReportHTMinMPDUStartSpacing, dot11RMNeighborReportHTRxMCSBitMask, dot11RMNeighborReportHTRxHighestSupportedDataRate, dot11RMNeighborReportHTTxMCSSetDefined, dot11RMNeighborReportHTTxRxMCSSetNotEqual, dot11RMNeighborReportHTTxMaxNumberSpatialStreamsSupported, dot11RMNeighborReportHTTxUnequalModulationSupported, dot11RMNeighborReportHTPCO, dot11RMNeighborReportHTPCOTransitionTime, dot11RMNeighborReportHTMCSFeedback, dot11RMNeighborReportHTCSupport, dot11RMNeighborReportHTRDResponder, dot11RMNeighborReportHTImplictTransmitBeamformingReceivingCap, dot11RMNeighborReportHTReceiveStaggeredSoundingCap, dot11RMNeighborReportHTTransmitStaggeredSoundingCap, dot11RMNeighborReportHTReceiveNDPCap, dot11RMNeighborReportHTTransmitNDPCap, dot11RMNeighborReportHTImplicitTransmitBeamformingCap, dot11RMNeighborReportHTTransmitBeamformingCalibration, dot11RMNeighborReportHTExplicitCSITransmitBeamformingCap, dot11RMNeighborReportHTExplicitNonCompressedSteeringCap, dot11RMNeighborReportHTExplicitCompressedSteeringCap, dot11RMNeighborReportHTExplicitTransmitBeamformingFeedback, dot11RMNbRprtHTExplicitNonCompressedBeamformingFeedbackCap, dot11RMNeighborReportHTExplicitCompressedBeamformingFeedbackCap, dot11RMNeighborReportHTTransmitBeamformingMinimalGrouping, dot11RMNbRprtHTCSINumberofTxBeamformingAntennasSuppt, dot11RMNbRprtHTNonCompressedSteeringNumofTxBmfmingAntennasSuppt, dot11RMNbRprtHTCompressedSteeringNumberofTxBmfmingAntennasSuppt, dot11RMNbRprtHTCSIMaxNumberofRowsTxBeamformingSuppt, dot11RMNeighborReportHTTransmitBeamformingChannelEstimationCap, dot11RMNeighborReportHTAntSelectionCap, dot11RMNeighborReportHTExplicitCSIFeedbackBasedTxASELCap, dot11RMNeighborReportHTAntIndicesFeedbackBasedTxASELCap, dot11RMNeighborReportHTExplicitCSIFeedbackBasedCap, dot11RMNeighborReportHTAntIndicesFeedbackCap, dot11RMNeighborReportHTRxASELCap, dot11RMNeighborReportHTTxSoundingPPDUsCap, dot11RMNeighborReportHTInfoPrimaryChannel, dot11RMNeighborReportHTInfoSecChannelOffset, dot11RMNeighborReportHTInfoSTAChannelWidth, dot11RMNeighborReportHTInfoRIFSMode, dot11RMNeighborReportHTInfoProtection, dot11RMNeighborReportHTInfoNonGreenfieldHTSTAsPresent, dot11RMNeighborReportHTInfoOBSSNonHTSTAsPresent, dot11RMNeighborReportHTInfoDualBeacon, dot11RMNeighborReportHTInfoDualCTSProtection, dot11RMNeighborReportHTInfoSTBCBeacon, dot11RMNeighborReportHTInfoLSIGTXOPProtectionSup, dot11RMNeighborReportHTInfoPCOActive, dot11RMNeighborReportHTInfoPCOPhase, dot11RMNeighborReportHTInfoBasicMCSSet, dot11RMNeighborReportHTSecChannelOffset, dot11RMNeighborReportExtCapPSMPSupport, dot11RMNeighborReportExtCapSPSMPSup, dot11RMNeighborReportExtCapServiceIntervalGranularity } STATUS deprecated DESCRIPTION "Superseded by dot11SMTRMConfig2. The SMTRMConfig package is a set of attributes that are present if the STA supports the Radio Measurement service." ::= { dot11Groups 39 } dot11FTComplianceGroup OBJECT-GROUP OBJECTS { -- Dot11FastBSSTransitionConfigEntry dot11FastBSSTransitionActivated, dot11FTMobilityDomainID, dot11FTOverDSActivated, dot11FTResourceRequestSupported, dot11FTR0KeyHolderID, dot11FTR0KeyLifetime, dot11FTR1KeyHolderID, dot11FTReassociationDeadline, -- Dot11RMNeighborReportEntry dot11RMNeighborReportMobilityDomain } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage fast BSS transition functionality. Note that additional objects for managing this functionality are located in the dot11FastBSS TransitionConfigTable." ::= { dot11Groups 40} dot11SMTbase8 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11SpectrumManagementImplemented, dot11SpectrumManagementRequired, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired, dot11QosOptionImplemented, dot11ImmediateBlockAckOptionImplemented, dot11DelayedBlockAckOptionImplemented, dot11DirectOptionImplemented, dot11APSDOptionImplemented, dot11QAckOptionImplemented, dot11QBSSLoadImplemented, dot11QueueRequestOptionImplemented, dot11TXOPRequestOptionImplemented, dot11MoreDataAckOptionImplemented, dot11AssociateInNQBSS, dot11DLSAllowedInQBSS, dot11DLSAllowed, dot11AssociateStation, dot11AssociateID, dot11AssociateFailStation, dot11AssociateFailStatus, dot11ReassociateStation, dot11ReassociateID, dot11ReassociateFailStation, dot11ReassociateFailStatus, dot11RadioMeasurementImplemented, dot11RadioMeasurementActivated, dot11RMMeasurementNavSync, dot11RMMeasurementPilotPeriod, dot11RMLinkMeasurementActivated, dot11RMNeighborReportActivated, dot11RMParallelMeasurementsActivated, dot11RMRepeatedMeasurementsActivated, dot11RMBeaconPassiveMeasurementActivated, dot11RMBeaconActiveMeasurementActivated, dot11RMBeaconTableMeasurementActivated, dot11RMBeaconMeasurementReportingConditionsActivated, dot11RMFrameMeasurementActivated, dot11RMChannelLoadMeasurementActivated, dot11RMNoiseHistogramMeasurementActivated, dot11RMStatisticsMeasurementActivated, dot11RMLCIMeasurementActivated, dot11RMLCIAzimuthActivated, dot11RMTransmitStreamCategoryMeasurementActivated, dot11RMTriggeredTransmitStreamCategoryMeasurementActivated, dot11RMAPChannelReportActivated, dot11RMMIBActivated, dot11RMMaxMeasurementDuration, dot11RMNonOperatingChannelMaxMeasurementDuration, dot11RMMeasurementPilotTransmissionInformationActivated, dot11RMMeasurementPilotActivated, dot11RMNeighborReportTSFOffsetActivated, dot11RMRCPIMeasurementActivated, dot11RMRSNIMeasurementActivated, dot11RMBSSAverageAccessDelayActivated, dot11RMBSSAvailableAdmissionCapacityActivated, dot11RMAntennaInformationActivated, dot11FastBSSTransitionImplemented } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase9. The SMTbase8 object class provides the necessary support at the STA to manage the processes in the STA so that the STA may work cooperatively as a part of an IEEE 802.11 network, when the STA is capable of multidomain operation. This object group should be implemented when the multidomain capability option is implemented." ::= { dot11Groups 41 } dot11PhyOFDMComplianceGroup3 OBJECT-GROUP OBJECTS { dot11CurrentFrequency, dot11FrequencyBandsImplemented, dot11ChannelStartingFactor, dot11FiveMHzOperationImplemented, dot11TenMHzOperationImplemented, dot11TwentyMHzOperationImplemented, dot11PhyOFDMChannelWidth, dot11OFDMCCAEDImplemented, dot11OFDMCCAEDRequired, dot11OFDMEDThreshold, dot11STATransmitPowerClass, dot11ACRType } STATUS current DESCRIPTION "Attributes that configure the OFDM PHY for IEEE Std 802.11." ::= { dot11Groups 42} dot11SMTbase9 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired, dot11QosOptionImplemented, dot11ImmediateBlockAckOptionImplemented, dot11DelayedBlockAckOptionImplemented, dot11DirectOptionImplemented, dot11APSDOptionImplemented, dot11QAckOptionImplemented, dot11QBSSLoadImplemented, dot11QueueRequestOptionImplemented, dot11TXOPRequestOptionImplemented, dot11MoreDataAckOptionImplemented, dot11AssociateInNQBSS, dot11DLSAllowedInQBSS, dot11DLSAllowed, dot11RadioMeasurementImplemented, dot11RadioMeasurementActivated, dot11FastBSSTransitionImplemented, dot11LCIDSEImplemented, dot11LCIDSERequired, dot11DSERequired, dot11ExtendedChannelSwitchActivated } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase10. The SMTbase9 object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network, when the STA is capable of multidomain operation. This object group should be implemented when the multidomain capability option is implemented." ::= { dot11Groups 43 } dot11PhyAntennaComplianceGroup2 OBJECT-GROUP OBJECTS { dot11CurrentTxAntenna, dot11DiversitySupportImplemented, dot11CurrentRxAntenna, dot11AntennaSelectionOptionImplemented, dot11TransmitExplicitCSIFeedbackASOptionImplemented, dot11TransmitIndicesFeedbackASOptionImplemented, dot11ExplicitCSIFeedbackASOptionImplemented, dot11TransmitIndicesComputationASOptionImplemented, dot11ReceiveAntennaSelectionOptionImplemented } STATUS current DESCRIPTION "Attributes for Data Rates for IEEE Std 802.11." ::= { dot11Groups 44 } dot11MACbase3 OBJECT-GROUP OBJECTS { dot11MACAddress, dot11GroupAddress, dot11GroupAddressesStatus, dot11RTSThreshold, dot11ShortRetryLimit, dot11LongRetryLimit, dot11FragmentationThreshold, dot11MaxTransmitMSDULifetime, dot11MaxReceiveLifetime, dot11ManufacturerID, dot11ProductID, dot11CAPLimit, dot11HCCWmin, dot11HCCWmax, dot11HCCAIFSN, dot11ADDBAResponseTimeout, dot11ADDTSResponseTimeout, dot11ChannelUtilizationBeaconIntervals, dot11ScheduleTimeout, dot11DLSResponseTimeout, dot11QAPMissingAckRetryLimit, dot11EDCAAveragingPeriod, dot11HTProtection, dot11RIFSMode, dot11PSMPControlledAccess, dot11ServiceIntervalGranularity, dot11DualCTSProtection, dot11LSIGTXOPFullProtectionActivated, dot11NonGFEntitiesPresent, dot11PCOActivated, dot11PCOFortyMaxDuration, dot11PCOTwentyMaxDuration, dot11PCOFortyMinDuration, dot11PCOTwentyMinDuration } STATUS deprecated DESCRIPTION "Superseded by dot11MACbase4. The MAC object class provides the necessary support for the access control, generation, and verification of frame check sequences (FCSs), and proper delivery of valid data to upper layers." ::= { dot11Groups 45 } dot11CountersGroup3 OBJECT-GROUP OBJECTS { dot11TransmittedFragmentCount, dot11TransmittedFrameCount, dot11FailedCount, dot11ReceivedFragmentCount, dot11GroupReceivedFrameCount, dot11FCSErrorCount, dot11WEPUndecryptableCount, dot11TransmittedFrameCount, dot11QosDiscardedFragmentCount, dot11AssociatedStationCount, dot11QosCFPollsReceivedCount, dot11QosCFPollsUnusedCount, dot11QosCFPollsUnusableCount, dot11QosCFPollsLostCount, dot11TransmittedAMSDUCount, dot11FailedAMSDUCount, dot11RetryAMSDUCount, dot11MultipleRetryAMSDUCount, dot11TransmittedOctetsInAMSDUCount, dot11AMSDUAckFailureCount, dot11ReceivedAMSDUCount, dot11ReceivedOctetsInAMSDUCount, dot11TransmittedAMPDUCount, dot11TransmittedMPDUsInAMPDUCount, dot11TransmittedOctetsInAMPDUCount, dot11AMPDUReceivedCount, dot11MPDUInReceivedAMPDUCount, dot11ReceivedOctetsInAMPDUCount, dot11AMPDUDelimiterCRCErrorCount, dot11ImplicitBARFailureCount, dot11ExplicitBARFailureCount, dot11ChannelWidthSwitchCount, dot11TwentyMHzFrameTransmittedCount, dot11FortyMHzFrameTransmittedCount, dot11TwentyMHzFrameReceivedCount, dot11FortyMHzFrameReceivedCount, dot11PSMPUTTGrantDuration, dot11PSMPUTTUsedDuration, dot11GrantedRDGUsedCount, dot11GrantedRDGUnusedCount, dot11TransmittedFramesInGrantedRDGCount, dot11TransmittedOctetsInGrantedRDGCount, dot11BeamformingFrameCount, dot11DualCTSSuccessCount, dot11DualCTSFailureCount, dot11STBCCTSSuccessCount, dot11STBCCTSFailureCount, dot11nonSTBCCTSSuccessCount, dot11nonSTBCCTSFailureCount, dot11RTSLSIGSuccessCount, dot11RTSLSIGFailureCount} STATUS deprecated DESCRIPTION "Superseded by dot11CountersGroup4. Attributes from the dot11CountersGroup that are not described in the dot11MACStatistics group. These objects are mandatory." ::= { dot11Groups 46 } dot11SMTbase10 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired, dot11QosOptionImplemented, dot11ImmediateBlockAckOptionImplemented, dot11DelayedBlockAckOptionImplemented, dot11DirectOptionImplemented, dot11APSDOptionImplemented, dot11QAckOptionImplemented, dot11QBSSLoadImplemented, dot11QueueRequestOptionImplemented, dot11TXOPRequestOptionImplemented, dot11MoreDataAckOptionImplemented, dot11AssociateInNQBSS, dot11DLSAllowedInQBSS, dot11DLSAllowed, dot11AssociateStation, dot11AssociateID, dot11AssociateFailStation, dot11AssociateFailStatus, dot11ReassociateStation, dot11ReassociateID, dot11ReassociateFailStation, dot11ReassociateFailStatus, dot11RadioMeasurementImplemented, dot11RadioMeasurementActivated, dot11FastBSSTransitionImplemented, dot11LCIDSEImplemented, dot11LCIDSERequired, dot11DSERequired, dot11ExtendedChannelSwitchActivated, dot11HighThroughputOptionImplemented, dot11RSNAPBACRequired, dot11PSMPOptionImplemented } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase 11. The SMTbase10 object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network." ::= { dot11Groups 47 } dot11PhyMCSGroup OBJECT-GROUP OBJECTS { dot11SupportedHTMCSTxValue, dot11SupportedHTMCSRxValue } STATUS current DESCRIPTION "Attributes for MCS for IEEE 802.11 HT." ::= { dot11Groups 48 } dot11PhyHTComplianceGroup OBJECT-GROUP OBJECTS { dot11HighThroughputOptionImplemented, dot11FortyMHzOperationImplemented, dot11FortyMHzOperationActivated, dot11FortyMHzIntolerant, dot11FortyMHzOptionImplemented, dot11CurrentPrimaryChannel, dot11CurrentSecondaryChannel, dot11HTGreenfieldOptionImplemented, dot11HTGreenfieldOptionActivated, dot11ShortGIOptionInTwentyImplemented, dot11ShortGIOptionInTwentyActivated, dot11ShortGIOptionInFortyImplemented, dot11ShortGIOptionInFortyActivated, dot11LDPCCodingOptionImplemented, dot11LDPCCodingOptionActivated, dot11TxSTBCOptionImplemented, dot11TxSTBCOptionActivated, dot11RxSTBCOptionImplemented, dot11RxSTBCOptionActivated, dot11BeamFormingOptionImplemented, dot11BeamFormingOptionActivated, dot11NumberOfSpatialStreamsImplemented, dot11NumberOfSpatialStreamsActivated, dot11HighestSupportedDataRate, dot11TxMCSSetDefined, dot11TxRxMCSSetNotEqual, dot11TxMaximumNumberSpatialStreamsSupported, dot11TxUnequalModulationSupported, dot11TransmitSoundingPPDUOptionImplemented, dot11NumberOfActiveRxAntennas } STATUS current DESCRIPTION "Attributes that configure the HT PHY for IEEE Std 802.11." ::= { dot11Groups 49 } dot11HTMACAdditions OBJECT-GROUP OBJECTS { dot11HTOperationalMCSSet, dot11MIMOPowerSave, dot11NDelayedBlockAckOptionImplemented, dot11MaxAMSDULength, dot11STBCControlFrameOptionImplemented, dot11LsigTxopProtectionOptionImplemented, dot11MaxRxAMPDUFactor, dot11MinimumMPDUStartSpacing, dot11PCOOptionImplemented, dot11TransitionTime, dot11MCSFeedbackOptionImplemented, dot11HTControlFieldSupported, dot11RDResponderOptionImplemented, dot11BSSWidthTriggerScanInterval, dot11BSSWidthChannelTransitionDelayFactor, dot11OBSSScanPassiveDwell, dot11OBSSScanActiveDwell, dot11OBSSScanPassiveTotalPerChannel, dot11OBSSScanActiveTotalPerChannel, dot112040BSSCoexistenceManagementSupport, dot11OBSSScanActivityThreshold, dot11SPPAMSDUCapable, dot11SPPAMSDURequired } STATUS deprecated DESCRIPTION "Superseded by dot11HTMACAdditions2 as dot11HTMACAdditions contains an object no longer used by IEEE Std 802.11 Attributes that configure the HT PHY for IEEE Std 802.11." ::= { dot11Groups 50 } dot11TransmitBeamformingGroup OBJECT-GROUP OBJECTS { dot11ReceiveStaggerSoundingOptionImplemented, dot11TransmitStaggerSoundingOptionImplemented, dot11ReceiveNDPOptionImplemented, dot11TransmitNDPOptionImplemented, dot11ImplicitTransmitBeamformingOptionImplemented, dot11CalibrationOptionImplemented, dot11ExplicitCSITransmitBeamformingOptionImplemented, dot11ExplicitNonCompressedBeamformingMatrixOptionImplemented, dot11ExplicitTransmitBeamformingCSIFeedbackOptionImplemented, dot11ExplicitNonCompressedBeamformingFeedbackOptionImplemented, dot11ExplicitCompressedBeamformingFeedbackOptionImplemented, dot11NumberBeamFormingCSISupportAntenna, dot11NumberNonCompressedBeamformingMatrixSupportAntenna, dot11NumberCompressedBeamformingMatrixSupportAntenna } STATUS current DESCRIPTION "Attributes that configure the Beamforming for IEEE 802.11 HT." ::= { dot11Groups 51 } dot11SMTbase11 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11SpectrumManagementImplemented, dot11SpectrumManagementRequired, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired, dot11QosOptionImplemented, dot11ImmediateBlockAckOptionImplemented, dot11DelayedBlockAckOptionImplemented, dot11DirectOptionImplemented, dot11APSDOptionImplemented, dot11QAckOptionImplemented, dot11QBSSLoadImplemented, dot11QueueRequestOptionImplemented, dot11TXOPRequestOptionImplemented, dot11MoreDataAckOptionImplemented, dot11AssociateInNQBSS, dot11DLSAllowedInQBSS, dot11DLSAllowed, dot11AssociateStation, dot11AssociateID, dot11AssociateFailStation, dot11AssociateFailStatus, dot11ReassociateStation, dot11ReassociateID, dot11ReassociateFailStation, dot11ReassociateFailStatus, dot11RadioMeasurementImplemented, dot11RadioMeasurementActivated, dot11RMMeasurementNavSync, dot11RMMeasurementPilotPeriod, dot11RMLinkMeasurementActivated, dot11RMNeighborReportActivated, dot11RMParallelMeasurementsActivated, dot11RMRepeatedMeasurementsActivated, dot11RMBeaconPassiveMeasurementActivated, dot11RMBeaconActiveMeasurementActivated, dot11RMBeaconTableMeasurementActivated, dot11RMBeaconMeasurementReportingConditionsActivated, dot11RMFrameMeasurementActivated, dot11RMChannelLoadMeasurementActivated, dot11RMNoiseHistogramMeasurementActivated, dot11RMStatisticsMeasurementActivated, dot11RMLCIMeasurementActivated, dot11RMLCIAzimuthActivated, dot11RMTransmitStreamCategoryMeasurementActivated, dot11RMTriggeredTransmitStreamCategoryMeasurementActivated, dot11RMAPChannelReportActivated, dot11RMMIBActivated, dot11RMMaxMeasurementDuration, dot11RMNonOperatingChannelMaxMeasurementDuration, dot11RMMeasurementPilotTransmissionInformationActivated, dot11RMMeasurementPilotActivated, dot11RMNeighborReportTSFOffsetActivated, dot11RMRCPIMeasurementActivated, dot11RMRSNIMeasurementActivated, dot11RMBSSAverageAccessDelayActivated, dot11RMBSSAvailableAdmissionCapacityActivated, dot11FastBSSTransitionImplemented, dot11LCIDSEImplemented, dot11LCIDSERequired, dot11DSERequired, dot11ExtendedChannelSwitchActivated, dot11HighThroughputOptionImplemented, dot11WirelessManagementImplemented, dot11RSNAPBACRequired, dot11PSMPOptionImplemented } STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase12. The SMTbase11 object class provides the necessary support at the STA to manage the processes in the STA so that the STA may work cooperatively as a part of an IEEE 802.11 network, when the STA is capable of multidomain operation. This object group should be implemented when the multidomain capability option is implemented." ::= { dot11Groups 53 } dot11SMTWNMRequest OBJECT-GROUP OBJECTS { dot11WNMRqstRowStatus, dot11WNMRqstToken, dot11WNMRqstIfIndex, dot11WNMRqstType, dot11WNMRqstTargetAdd, dot11WNMRqstTimeStamp, dot11WNMRqstRndInterval, dot11WNMRqstDuration, dot11WNMRqstMcstGroup, dot11WNMRqstMcstTrigCon, dot11WNMRqstMcstTrigInactivityTimeout, dot11WNMRqstMcstTrigReactDelay, dot11WNMRqstLCRRqstSubject, dot11WNMRqstLCRIntervalUnits, dot11WNMRqstLCRServiceInterval, dot11WNMRqstLIRRqstSubject, dot11WNMRqstLIRIntervalUnits, dot11WNMRqstLIRServiceInterval, dot11WNMRqstEventToken, dot11WNMRqstEventType, dot11WNMRqstEventResponseLimit, dot11WNMRqstEventTargetBssid, dot11WNMRqstEventSourceBssid, dot11WNMRqstEventTransitTimeThresh, dot11WNMRqstEventTransitMatchValue, dot11WNMRqstEventFreqTransitCountThresh, dot11WNMRqstEventFreqTransitInterval, dot11WNMRqstEventRsnaAuthType, dot11WNMRqstEapType, dot11WNMRqstEapVendorId, dot11WNMRqstEapVendorType, dot11WNMRqstEventRsnaMatchValue, dot11WNMRqstEventPeerMacAddress, dot11WNMRqstOperatingClass, dot11WNMRqstChanNumber, dot11WNMRqstDiagToken, dot11WNMRqstDiagType, dot11WNMRqstDiagTimeout, dot11WNMRqstDiagBssid, dot11WNMRqstDiagProfileId, dot11WNMRqstDiagCredentials, dot11WNMRqstLocConfigLocIndParams, dot11WNMRqstLocConfigChanList, dot11WNMRqstLocConfigBcastRate, dot11WNMRqstLocConfigOptions, dot11WNMRqstBssTransitQueryReason, dot11WNMRqstBssTransitReqMode, dot11WNMRqstBssTransitDisocTimer, dot11WNMRqstBssTransitSessInfoURL, dot11WNMRqstBssTransitCandidateList, dot11WNMRqstColocInterfAutoEnable, dot11WNMRqstColocInterfRptTimeout, dot11WNMRqstVendorSpecific } STATUS current DESCRIPTION "The SMTWNMRequest package is a set of attributes that shall be present if the STA supports the WNM service." ::= { dot11Groups 54 } dot11SMTWNMReport OBJECT-GROUP OBJECTS { dot11WNMVendorSpecificRprtRqstToken, dot11WNMVendorSpecificRprtIfIndex, dot11WNMVendorSpecificRprtContent, dot11WNMMulticastDiagnosticRprtRqstToken, dot11WNMMulticastDiagnosticRprtIfIndex, dot11WNMMulticastDiagnosticRprtMeasurementTime, dot11WNMMulticastDiagnosticRprtDuration, dot11WNMMulticastDiagnosticRprtMcstGroup, dot11WNMMulticastDiagnosticRprtReason, dot11WNMMulticastDiagnosticRprtRcvdMsduCount, dot11WNMMulticastDiagnosticRprtFirstSeqNumber, dot11WNMMulticastDiagnosticRprtLastSeqNumber, dot11WNMMulticastDiagnosticRprtMcstRate, dot11WNMLocationCivicRprtRqstToken, dot11WNMLocationCivicRprtIfIndex, dot11WNMLocationCivicRprtCivicLocation, dot11WNMLocationIdentifierRprtRqstToken, dot11WNMLocationIdentifierRprtIfIndex, dot11WNMLocationIdentifierRprtExpirationTSF, dot11WNMLocationIdentifierRprtPublicIdUri, dot11WNMEventTransitRprtRqstToken, dot11WNMEventTransitRprtIfIndex, dot11WNMEventTransitRprtEventStatus, dot11WNMEventTransitRprtEventTSF, dot11WNMEventTransitRprtUTCOffset, dot11WNMEventTransitRprtTimeError, dot11WNMEventTransitRprtSourceBssid, dot11WNMEventTransitRprtTargetBssid, dot11WNMEventTransitRprtTransitTime, dot11WNMEventTransitRprtTransitReason, dot11WNMEventTransitRprtTransitResult, dot11WNMEventTransitRprtSourceRCPI, dot11WNMEventTransitRprtSourceRSNI, dot11WNMEventTransitRprtTargetRCPI, dot11WNMEventTransitRprtTargetRSNI, dot11WNMEventRsnaRprtRqstToken, dot11WNMEventRsnaRprtIfIndex, dot11WNMEventRsnaRprtEventStatus, dot11WNMEventRsnaRprtEventTSF, dot11WNMEventRsnaRprtUTCOffset, dot11WNMEventRsnaRprtTimeError, dot11WNMEventRsnaRprtTargetBssid, dot11WNMEventRsnaRprtAuthType, dot11WNMEventRsnaRprtEapMethod, dot11WNMEventRsnaRprtResult, dot11WNMEventRsnaRprtRsnElement, dot11WNMEventPeerRprtRqstToken, dot11WNMEventPeerRprtIfIndex, dot11WNMEventPeerRprtEventStatus, dot11WNMEventPeerRprtEventTSF, dot11WNMEventPeerRprtUTCOffset, dot11WNMEventPeerRprtTimeError, dot11WNMEventPeerRprtPeerMacAddress, dot11WNMEventPeerRprtOperatingClass, dot11WNMEventPeerRprtChanNumber, dot11WNMEventPeerRprtStaTxPower, dot11WNMEventPeerRprtConnTime, dot11WNMEventPeerRprtPeerStatus, dot11WNMEventWNMLogRprtRqstToken, dot11WNMEventWNMLogRprtIfIndex, dot11WNMEventWNMLogRprtEventStatus, dot11WNMEventWNMLogRprtEventTSF, dot11WNMEventWNMLogRprtUTCOffset, dot11WNMEventWNMLogRprtTimeError, dot11WNMEventWNMLogRprtContent, dot11WNMDiagMfrInfoRprtRqstToken, dot11WNMDiagMfrInfoRprtIfIndex, dot11WNMDiagMfrInfoRprtEventStatus, dot11WNMDiagMfrInfoRprtMfrOi, dot11WNMDiagMfrInfoRprtMfrIdString, dot11WNMDiagMfrInfoRprtMfrModelString, dot11WNMDiagMfrInfoRprtMfrSerialNumberString, dot11WNMDiagMfrInfoRprtMfrFirmwareVersion, dot11WNMDiagMfrInfoRprtMfrAntennaType, dot11WNMDiagMfrInfoRprtCollocRadioType, dot11WNMDiagMfrInfoRprtDeviceType, dot11WNMDiagMfrInfoRprtCertificateID, dot11WNMDiagConfigProfRprtRqstToken, dot11WNMDiagConfigProfRprtIfIndex, dot11WNMDiagConfigProfRprtEventStatus, dot11WNMDiagConfigProfRprtProfileId, dot11WNMDiagConfigProfRprtSupportedOperatingClasses, dot11WNMDiagConfigProfRprtTxPowerMode, dot11WNMDiagConfigProfRprtTxPowerLevels, dot11WNMDiagConfigProfRprtCipherSuite, dot11WNMDiagConfigProfRprtAkmSuite, dot11WNMDiagConfigProfRprtEapType, dot11WNMDiagConfigProfRprtEapVendorID, dot11WNMDiagConfigProfRprtEapVendorType, dot11WNMDiagConfigProfRprtCredentialType, dot11WNMDiagConfigProfRprtSSID, dot11WNMDiagConfigProfRprtPowerSaveMode, dot11WNMDiagAssocRprtRqstToken, dot11WNMDiagAssocRprtIfIndex, dot11WNMDiagAssocRprtEventStatus, dot11WNMDiagAssocRprtBssid, dot11WNMDiagAssocRprtOperatingClass, dot11WNMDiagAssocRprtChannelNumber, dot11WNMDiagAssocRprtStatusCode, dot11WNMDiag8021xAuthRprtRqstToken, dot11WNMDiag8021xAuthRprtIfIndex, dot11WNMDiag8021xAuthRprtEventStatus, dot11WNMDiag8021xAuthRprtBssid, dot11WNMDiag8021xAuthRprtOperatingClass, dot11WNMDiag8021xAuthRprtChannelNumber, dot11WNMDiag8021xAuthRprtEapType, dot11WNMDiag8021xAuthRprtEapVendorID, dot11WNMDiag8021xAuthRprtEapVendorType, dot11WNMDiag8021xAuthRprtCredentialType, dot11WNMDiag8021xAuthRprtStatusCode, dot11WNMLocConfigRprtRqstToken, dot11WNMLocConfigRprtIfIndex, dot11WNMLocConfigRprtLocIndParams, dot11WNMLocConfigRprtLocIndChanList, dot11WNMLocConfigRprtLocIndBcastRate, dot11WNMLocConfigRprtLocIndOptions, dot11WNMLocConfigRprtStatusConfigSubelemId, dot11WNMLocConfigRprtStatusResult, dot11WNMLocConfigRprtVendorSpecificRprtContent, dot11WNMBssTransitRprtRqstToken, dot11WNMBssTransitRprtIfIndex, dot11WNMBssTransitRprtStatusCode, dot11WNMBssTransitRprtBSSTerminationDelay, dot11WNMBssTransitRprtTargetBssid, dot11WNMBssTransitRprtCandidateList, dot11WNMColocInterfRprtRqstToken, dot11WNMColocInterfRprtIfIndex, dot11WNMColocInterfRprtPeriod, dot11WNMColocInterfRprtInterfLevel, dot11WNMColocInterfRprtInterfAccuracy, dot11WNMColocInterfRprtInterfIndex, dot11WNMColocInterfRprtInterfInterval, dot11WNMColocInterfRprtInterfBurstLength, dot11WNMColocInterfRprtInterfStartTime, dot11WNMColocInterfRprtInterfCenterFreq, dot11WNMColocInterfRprtInterfBandwidth } STATUS current DESCRIPTION "The SMTWNMReport package is a set of attributes that shall be present if the STA supports the WNM service." ::= { dot11Groups 55 } dot11SMTbase12 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11AuthenticationResponseTimeout, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11SpectrumManagementImplemented, dot11SpectrumManagementRequired, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired, dot11QosOptionImplemented, dot11ImmediateBlockAckOptionImplemented, dot11DelayedBlockAckOptionImplemented, dot11DirectOptionImplemented, dot11APSDOptionImplemented, dot11QAckOptionImplemented, dot11QBSSLoadImplemented, dot11QueueRequestOptionImplemented, dot11TXOPRequestOptionImplemented, dot11MoreDataAckOptionImplemented, dot11AssociateInNQBSS, dot11DLSAllowedInQBSS, dot11DLSAllowed, dot11AssociateStation, dot11AssociateID, dot11AssociateFailStation, dot11AssociateFailStatus, dot11ReassociateStation, dot11ReassociateID, dot11ReassociateFailStation, dot11ReassociateFailStatus, dot11RadioMeasurementImplemented, dot11RadioMeasurementActivated, dot11RMMeasurementNavSync, dot11RMMeasurementPilotPeriod, dot11RMLinkMeasurementActivated, dot11RMNeighborReportActivated, dot11RMParallelMeasurementsActivated, dot11RMRepeatedMeasurementsActivated, dot11RMBeaconPassiveMeasurementActivated, dot11RMBeaconActiveMeasurementActivated, dot11RMBeaconTableMeasurementActivated, dot11RMBeaconMeasurementReportingConditionsActivated, dot11RMFrameMeasurementActivated, dot11RMChannelLoadMeasurementActivated, dot11RMNoiseHistogramMeasurementActivated, dot11RMStatisticsMeasurementActivated, dot11RMLCIMeasurementActivated, dot11RMLCIAzimuthActivated, dot11RMTransmitStreamCategoryMeasurementActivated, dot11RMTriggeredTransmitStreamCategoryMeasurementActivated, dot11RMAPChannelReportActivated, dot11RMMIBActivated, dot11RMMaxMeasurementDuration, dot11RMNonOperatingChannelMaxMeasurementDuration, dot11RMMeasurementPilotTransmissionInformationActivated, dot11RMMeasurementPilotActivated, dot11RMNeighborReportTSFOffsetActivated, dot11RMRCPIMeasurementActivated, dot11RMRSNIMeasurementActivated, dot11RMBSSAverageAccessDelayActivated, dot11RMBSSAvailableAdmissionCapacityActivated, dot11FastBSSTransitionImplemented, dot11LCIDSEImplemented, dot11LCIDSERequired, dot11DSERequired, dot11ExtendedChannelSwitchActivated, dot11HighThroughputOptionImplemented, dot11WirelessManagementImplemented, dot11MeshActivated, dot11RSNAPBACRequired, dot11PSMPOptionImplemented} STATUS deprecated DESCRIPTION "Superseded by dot11SMTbase13. The SMTbase12 object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network." ::= { dot11Groups 57 } dot11OperatingClassesGroup OBJECT-GROUP OBJECTS { dot11OperatingClass, dot11CoverageClass } STATUS current DESCRIPTION "Attributes that configure the OFDM PHY for IEEE Std 802.11 in many regulatory domains." ::= { dot11Groups 58 } dot11PhyOperationComplianceGroup2 OBJECT-GROUP OBJECTS { dot11PHYType, dot11CurrentRegDomain } STATUS current DESCRIPTION "PHY operations attributes." ::= { dot11Groups 59 } dot11MeshComplianceGroup OBJECT-GROUP OBJECTS { -- dot11MeshSTAConfigTable dot11MeshID, dot11MeshNumberOfPeerings, dot11MeshAcceptingAdditionalPeerings, dot11MeshConnectedToMeshGate, dot11MeshSecurityActivated, dot11MeshActiveAuthenticationProtocol, dot11MeshMaxRetries, dot11MeshRetryTimeout, dot11MeshConfirmTimeout, dot11MeshHoldingTimeout, dot11MeshActivePathSelectionProtocol, dot11MeshActivePathSelectionMetric, dot11MeshForwarding, dot11MeshTTL, dot11MeshGateAnnouncements, dot11MeshActiveCongestionControlMode, dot11MeshActiveSynchronizationMethod, dot11MeshNbrOffsetMaxNeighbor, dot11MBCAActivated, dot11MCCAImplemented, dot11MCCAActivated } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage mandatory mesh functionality. Note that additional objects for managing mesh functionality are located in the dot11MeshOptionGroup, dot11MeshHWMPComplianceGroup, and dot11PasswordAuthComplianceGroup." ::= { dot11Groups 56} dot11MeshOptionGroup OBJECT-GROUP OBJECTS { -- dot11MeshSTAConfigTable dot11MeshConfigGroupUpdateCount, dot11MeshGateAnnouncementInterval, dot11MeshBeaconTimingReportInterval, dot11MeshBeaconTimingReportMaxNum, dot11MeshDelayedBeaconTxInterval, dot11MeshDelayedBeaconTxMaxDelay, dot11MeshDelayedBeaconTxMinDelay, dot11MeshAverageBeaconFrameDuration, dot11MeshSTAMissingAckRetryLimit, dot11MeshAwakeWindowDuration, dot11MAFlimit, dot11MCCAScanDuration, dot11MCCAAdvertPeriodMax, dot11MCCATrackStatesCapable, dot11MCCATrackStatesActive, dot11MCCAOPtimeout, dot11MCCACWmin, dot11MCCACWmax, dot11MCCAAIFSN } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage optional mesh functionality. Note that other objects for managing mesh functionality are located in the dot11MeshComplianceGroup, dot11MeshHWMPComplianceGroup, and dot11PasswordAuthComplianceGroup." ::= { dot11Groups 60 } dot11MeshHWMPComplianceGroup OBJECT-GROUP OBJECTS { -- dot11MeshHWMPConfigTable dot11MeshHWMPmaxPREQretries, dot11MeshHWMPnetDiameter, dot11MeshHWMPnetDiameterTraversalTime, dot11MeshHWMPpreqMinInterval, dot11MeshHWMPperrMinInterval, dot11MeshHWMPactivePathToRootTimeout, dot11MeshHWMPactivePathTimeout, dot11MeshHWMProotMode, dot11MeshHWMProotInterval, dot11MeshHWMPrannInterval, dot11MeshHWMPtargetOnly, dot11MeshHWMPmaintenanceInterval, dot11MeshHWMPconfirmationInterval } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage HWMP path selection functionality. Note that other objects for managing mesh functionality are located in the dot11MeshComplianceGroup, dot11MeshOptionGroup, and dot11PasswordAuthComplianceGroup." ::= { dot11Groups 61 } dot11PasswordAuthComplianceGroup OBJECT-GROUP OBJECTS { -- dot11RSNAConfigTable dot11RSNASAERetransPeriod, dot11RSNASAEAntiCloggingThreshold, dot11RSNASAESync, -- dot11RSNAConfigPasswordValueTable -- dot11RSNAConfigPasswordValueIndex, dot11RSNAConfigPasswordCredential, dot11RSNAConfigPasswordPeerMac, -- dot11RSNAConfigDLCGroupTable -- dot11RSNAConfigDLCGroupIndex, dot11RSNAConfigDLCGroupIdentifier } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage password authentication. Note that other objects for managing mesh functionality are located in the dot11MeshComplianceGroup, dot11MeshOptionGroup, and dot11MeshHWMPComplianceGroup." ::= { dot11Groups 62 } dot11QMFComplianceGroup OBJECT-GROUP OBJECTS { dot11QMFActivated, dot11QMFReconfigurationActivated, dot11QMFPolicyChangeTimeout } STATUS current DESCRIPTION "This object group provides the objects from the IEEE 802.11 MIB required to manage QoS Management Frame functionality." ::= { dot11Groups 63 } dot11DMGComplianceGroup OBJECT-GROUP OBJECTS { dot11MultibandImplemented, dot11DMGOptionImplemented, dot11RelayActivated, dot11REDSActivated, dot11RDSActivated, dot11RSNAProtectedManagementFramesActivated, dot11MultipleMACActivated, dot11ClusteringActivated, dot11LowPowerSCPHYImplemented, dot11LowPowerSCPHYActivated, dot11RSNAOperatingChannelValidationActivated } STATUS current DESCRIPTION "Attributes that configure the DMG Group for IEEE Std 802.11." ::= { dot11Groups 64 } dot11DMGOperationsComplianceGroup OBJECT-GROUP OBJECTS { dot11MaxLostBeacons, dot11MinBHIDuration, dot11PSRequestSuspensionInterval, dot11BroadcastSTAInfoDuration, dot11NbrOfChangeBeacons, dot11ImplicitHandoverLostBeacons, dot11MinPPDuration, dot11SPIdleTimeout, dot11QABTimeout, dot11ClusterEnableTime, dot11PNWarningThresholdLow,dot11PNWarningThresholdHigh, dot11BeaconSPDuration, dot11PNExhaustionThresholdLow,dot11PNExhaustionThresholdHigh, dot11MaxNumberOfClusteringMonitoringPeriods, dot11DMGEcssPolicyDetailUpdateDurationMax, dot11DMGEcssClusterReportDurationMin, dot11DMGNavSync } STATUS current DESCRIPTION "Attributes that configure the DMG Operation for IEEE Std 802.11." ::= { dot11Groups 65 } dot11DMGBeamformingComplianceGroup OBJECT-GROUP OBJECTS { dot11MaxBFTime, dot11BFTXSSTime, dot11MaximalSectorScan, dot11ABFTRTXSSSwitch, dot11RSSRetryLimit, dot11RSSBackoff, dot11BFRetryLimit, dot11BFTXSSTime, dot11BeamLinkMaintenanceTime,dot11BeamTrackingTimeLimit } STATUS current DESCRIPTION "Attributes that configure the DMG Beamforming functionality for IEEE Std 802.11." ::= { dot11Groups 66 } dot11DMGCountersComplianceGroup OBJECT-GROUP OBJECTS { dot11RSNAStatsGCMPReplays, dot11RSNAStatsRobustMgmtGCMPReplays } STATUS current DESCRIPTION "Attributes that are used as counters for a DMG STA for IEEE Std 802.11." ::= { dot11Groups 67 } dot11AVSBase OBJECT-GROUP OBJECTS { dot11RobustAVStreamingImplemented, dot11GCRActivated, dot11AdvancedGCRImplemented, dot11AdvancedGCRActivated, dot11SCSImplemented, dot11SCSActivated, dot11QLoadReportActivated, dot11AlternateEDCAActivated, dot11PublicHCCATXOPNegotiationActivated, dot11GCRGroupMembershipAnnouncementActivated, dot11MeshGCRImplemented, dot11MeshGCRActivated, dot11PublicHCCATXOPNegotiationImplemented, dot11PublicHCCATXOPNegotiationActivated, dot11ProtectedHCCATXOPNegotiationImplemented, dot11ProtectedHCCATXOPNegotiationActivated, dot11ProtectedQLoadReportImplemented, dot11ProtectedQLoadReportActivated, dot11QLoadReportIntervalDTIM, dot11HCCATXOPBeaconTimeout, dot11GCRConcealmentAddress, dot11GCRPolicyChangeTimeout, dot11QLoadReportDelay, dot11DefaultSurplusBandwidthAllowance, dot11ShortDEIRetryLimit, dot11LongDEIRetryLimit, dot11UnsolicitedRetryLimit, dot11STAStatisticsAverageMSDUSizeVideo, dot11STAStatisticsAverageMSDUSizeVoice, dot11STAStatisticsAverageBitrateVideo, dot11STAStatisticsAverageBitrateVoice } STATUS deprecated DESCRIPTION "Superseded by dot11AVSBase2. The AVSBase package is a set of attributes that are present if the STA supports the robust audio video streaming features." ::= { dot11Groups 68 } dot11AVSAPCGroup OBJECT-GROUP OBJECTS { dot11APCEntryAvoidanceDuration, dot11APCEntryAvoidanceServiceInterval, dot11APCEntryAvoidanceOffset, dot11APCEntryMACAddress } STATUS current DESCRIPTION "The AVSAPCGroup package is a set of attributes that are present if the STA supports HCCA TXOP negotiation." ::= { dot11Groups 69 } dot11TVWSComplianceGroup OBJECT-GROUP OBJECTS { dot11ChannelScheduleManagementActivated, dot11ContactVerificationSignalActivated, dot11NetworkChannelControlActivated, dot11WhiteSpaceMapActivated, dot11GDDActivated, dot11TVHTOptionImplemented } STATUS current DESCRIPTION "Attributes that configure the TVWS Group for IEEE Std 802.11." ::= { dot11Groups 70 } dot11SpectrumManagementGroup OBJECT-GROUP OBJECTS { -- Dot11SpectrumManagementEntry -- dot11SpectrumManagementIndex, dot11ChannelSwitchTime, dot11PowerCapabilityMaxImplemented, dot11PowerCapabilityMinImplemented } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB for spectrum management." ::= { dot11Groups 72 } dot11ProtectedManagementFrameGroup OBJECT-GROUP OBJECTS { -- Dot11StationConfigEntry dot11RSNAProtectedManagementFramesActivated, dot11RSNAUnprotectedManagementFramesAllowed, dot11AssociationSAQueryMaximumTimeout, dot11AssociationSAQueryRetryTimeout, -- dot11RSNAStatsEntry dot11RSNAStatsCMACReplays, dot11RSNAStatsRobustMgmtCCMPReplays, dot11RSNAStatsBIPMICErrors, dot11RSNAOperatingChannelValidationActivated} STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to operate management frame protection." ::= { dot11Groups 73 } dot11LCIDSEGroup OBJECT-GROUP OBJECTS { -- Dot11LCIDSEEntry -- dot11LCIDSEIndex, dot11LCIDSEIfIndex, dot11LCIDSECurrentOperatingClass, dot11LCIDSELatitudeUncertainty, dot11LCIDSELatitudeInteger, dot11LCIDSELatitudeFraction, dot11LCIDSELongitudeUncertainty, dot11LCIDSELongitudeInteger, dot11LCIDSELongitudeFraction, dot11LCIDSEAltitudeType, dot11LCIDSEAltitudeUncertainty, dot11LCIDSEAltitude, dot11LCIDSEDatum, dot11RegLocAgreement, dot11RegLocDSE, dot11DependentSTA, dot11DependentEnablementIdentifier, dot11DSEEnablementTimeLimit, dot11DSEEnablementFailHoldTime, dot11DSERenewalTime, dot11DSETransmitDivisor } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to enable 3650-3700 MHz Operation in USA." ::= { dot11Groups 74 } dot11TDLSComplianceGroup OBJECT-GROUP OBJECTS { -- Dot11StationConfigEntry dot11TunneledDirectLinkSetupImplemented, dot11TDLSPeerUAPSDBufferSTAActivated, dot11TDLSPeerPSMActivated, dot11TDLSPeerUAPSDIndicationWindow, dot11TDLSChannelSwitchingActivated, dot11TDLSPeerSTAMissingAckRetryLimit, dot11TDLSResponseTimeout, dot11OCBActivated, dot11TDLSNavSync, dot11TDLSDiscoveryRequestWindow, dot11TDLSACDeterminationInterval } STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to operate tunneled direct link setup." ::= { dot11Groups 75 } dot11VHTTransmitBeamformingGroup OBJECT-GROUP OBJECTS { dot11VHTSUBeamformeeOptionImplemented, dot11VHTSUBeamformerOptionImplemented, dot11VHTMUBeamformeeOptionImplemented, dot11VHTMUBeamformerOptionImplemented, dot11VHTNumberSoundingDimensions, dot11VHTBeamformeeNTxSupport } STATUS current DESCRIPTION "Attributes that configure VHT transmit beamforming for IEEE Std 802.11." ::= { dot11Groups 76 } dot11PhyVHTComplianceGroup OBJECT-GROUP OBJECTS { dot11VHTChannelWidthOptionImplemented, dot11CurrentChannelWidth, dot11CurrentChannelCenterFrequencyIndex0, dot11CurrentChannelCenterFrequencyIndex1, dot11VHTShortGIOptionIn80Implemented, dot11VHTShortGIOptionIn80Activated, dot11VHTShortGIOptionIn160and80p80Implemented, dot11VHTShortGIOptionIn160and80p80Activated, dot11VHTLDPCCodingOptionImplemented, dot11VHTLDPCCodingOptionActivated, dot11VHTTxSTBCOptionImplemented, dot11VHTTxSTBCOptionActivated, dot11VHTRxSTBCOptionImplemented, dot11VHTRxSTBCOptionActivated, dot11VHTMUMaxUsersImplemented, dot11VHTMUMaxNSTSPerUserImplemented, dot11VHTMUMaxNSTSTotalImplemented, dot11VHTMaxNTxChainsImplemented, dot11VHTMaxNTxChainsActivated} STATUS current DESCRIPTION "Attributes that configure the VHT PHY." ::= { dot11Groups 77 } dot11VHTMACAdditions OBJECT-GROUP OBJECTS { dot11VHTOptionImplemented, dot11OperatingModeNotificationImplemented, dot11MaxMPDULength, dot11VHTMaxRxAMPDUFactor, dot11VHTControlFieldOptionImplemented, dot11VHTTXOPPowerSaveOptionImplemented, dot11VHTRxVHTMCSMap, dot11VHTRxHighestDataRateSupported, dot11VHTTxVHTMCSMap, dot11VHTTxHighestDataRateSupported, dot11VHTOBSSScanCount, dot11VHTExtendedNSSBWCapable } STATUS current DESCRIPTION "Attributes that configure the VHT MAC." ::= { dot11Groups 78 } dot11PhyTxPowerComplianceGroup2 OBJECT-GROUP OBJECTS { dot11TxPowerLevelExtended, dot11CurrentTxPowerLevelExtended } STATUS current DESCRIPTION "Additional attributes for Control and Management of transmit power." ::= { dot11Groups 79 } dot11TVHTTransmitBeamformingGroup OBJECT-GROUP OBJECTS { dot11TVHTSUBeamformeeOptionImplemented, dot11TVHTSUBeamformerOptionImplemented, dot11TVHTMUBeamformeeOptionImplemented, dot11TVHTMUBeamformerOptionImplemented, dot11TVHTNumberSoundingDimensions, dot11TVHTBeamformeeNTxSupport } STATUS current DESCRIPTION "Attributes that configure TVHT transmit beamforming for IEEE Std 802.11." ::= { dot11Groups 80 } dot11PhyTVHTComplianceGroup OBJECT-GROUP OBJECTS { dot11TVHTChannelWidthOptionImplemented, dot11TVHTCurrentChannelWidth, dot11TVHTCurrentChannelCenterFrequencyIndex0, dot11TVHTCurrentChannelCenterFrequencyIndex1, dot11TVHTShortGIOptionIn4WImplemented, dot11TVHTShortGIOptionIn4WActivated, dot11TVHTLDPCCodingOptionImplemented, dot11TVHTLDPCCodingOptionActivated, dot11TVHTTxSTBCOptionImplemented, dot11TVHTTxSTBCOptionActivated, dot11TVHTRxSTBCOptionImplemented, dot11TVHTRxSTBCOptionActivated, dot11TVHTMUMaxUsersImplemented, dot11TVHTMUMaxNSTSPerUserImplemented, dot11TVHTMUMaxNSTSTotalImplemented, dot11TVHTMaxNTxChainsImplemented, dot11TVHTMaxNTxChainsActivated } STATUS current DESCRIPTION "Attributes that configure the TVHT PHY." ::= { dot11Groups 81 } dot11MACbase4 OBJECT-GROUP OBJECTS { dot11MACAddress, dot11GroupAddress, dot11GroupAddressesStatus, dot11RTSThreshold, dot11ShortRetryLimit, dot11LongRetryLimit, dot11FragmentationThreshold, dot11MaxTransmitMSDULifetime, dot11MaxReceiveLifetime, dot11ManufacturerID, dot11ProductID, dot11CAPLimit, dot11HCCWmin, dot11HCCWmax, dot11HCCAIFSN, dot11ChannelUtilizationBeaconIntervals, dot11ScheduleTimeout, dot11DLSResponseTimeout, dot11QAPMissingAckRetryLimit, dot11EDCAAveragingPeriod, dot11HTProtection, dot11RIFSMode, dot11PSMPControlledAccess, dot11ServiceIntervalGranularity, dot11DualCTSProtection, dot11LSIGTXOPFullProtectionActivated, dot11NonGFEntitiesPresent, dot11PCOActivated, dot11PCOFortyMaxDuration, dot11PCOTwentyMaxDuration, dot11PCOFortyMinDuration, dot11PCOTwentyMinDuration } STATUS deprecated DESCRIPTION " Superseded by dot11MACbase5. The MAC object class provides the necessary support for the access control, generation, and verification of frame check sequences (FCSs), and proper delivery of valid data to upper layers." ::= { dot11Groups 84 } dot11CountersGroup4 OBJECT-GROUP OBJECTS { dot11TransmittedFragmentCount, dot11TransmittedFrameCount, dot11FailedCount, dot11ReceivedFragmentCount, dot11GroupReceivedFrameCount, dot11FCSErrorCount, dot11WEPUndecryptableCount, dot11TransmittedFrameCount, dot11QosDiscardedFragmentCount, dot11AssociatedStationCount, dot11QosCFPollsReceivedCount, dot11QosCFPollsUnusedCount, dot11QosCFPollsUnusableCount, dot11QosCFPollsLostCount, dot11TransmittedAMSDUCount, dot11FailedAMSDUCount, dot11RetryAMSDUCount, dot11MultipleRetryAMSDUCount, dot11TransmittedOctetsInAMSDUCount, dot11AMSDUAckFailureCount, dot11ReceivedAMSDUCount, dot11ReceivedOctetsInAMSDUCount, dot11TransmittedAMPDUCount, dot11TransmittedMPDUsInAMPDUCount, dot11TransmittedOctetsInAMPDUCount, dot11AMPDUReceivedCount, dot11MPDUInReceivedAMPDUCount, dot11ReceivedOctetsInAMPDUCount, dot11AMPDUDelimiterCRCErrorCount, dot11ImplicitBARFailureCount, dot11ExplicitBARFailureCount, dot11ChannelWidthSwitchCount, dot11TwentyMHzFrameTransmittedCount, dot11FortyMHzFrameTransmittedCount, dot11TwentyMHzFrameReceivedCount, dot11FortyMHzFrameReceivedCount, dot11PSMPUTTGrantDuration, dot11PSMPUTTUsedDuration, dot11GrantedRDGUsedCount, dot11GrantedRDGUnusedCount, dot11TransmittedFramesInGrantedRDGCount, dot11TransmittedOctetsInGrantedRDGCount, dot11BeamformingFrameCount, dot11DualCTSSuccessCount, dot11DualCTSFailureCount, dot11STBCCTSSuccessCount, dot11STBCCTSFailureCount, dot11nonSTBCCTSSuccessCount, dot11nonSTBCCTSFailureCount, dot11RTSLSIGSuccessCount, dot11RTSLSIGFailureCount, dot11TransmittedMSDUOctetsCount, dot11ReceivedMSDUOctetsCount } STATUS deprecated DESCRIPTION " Superseded by dot11CountersGroup5. Attributes from the dot11CountersGroup that are not described in the dot11MACStatistics group. These objects are mandatory." ::= { dot11Groups 85 } dot11BSSStatisticsGroup OBJECT-GROUP OBJECTS { dot11AssociatedStationCount, dot11BSSLoadChannelUtilization, dot11BSSLoadAvailableAdmissionCapacity, dot11BSSLoadAssocAttemptCount, dot11BSSLoadAssocFailCount, dot11BSSLoadReassocAttemptCount, dot11BSSLoadReassocFailCount } STATUS current DESCRIPTION "The BSS Statistics group defines those objects that provide access to local measurements by an AP of its BSS." ::= { dot11Groups 86 } dot11HTMACAdditions2 OBJECT-GROUP OBJECTS { dot11MIMOPowerSave, dot11NDelayedBlockAckOptionImplemented, dot11MaxAMSDULength, dot11STBCControlFrameOptionImplemented, dot11LsigTxopProtectionOptionImplemented, dot11MaxRxAMPDUFactor, dot11MinimumMPDUStartSpacing, dot11PCOOptionImplemented, dot11TransitionTime, dot11MCSFeedbackOptionImplemented, dot11HTControlFieldSupported, dot11RDResponderOptionImplemented, dot11BSSWidthTriggerScanInterval, dot11BSSWidthChannelTransitionDelayFactor, dot11OBSSScanPassiveDwell, dot11OBSSScanActiveDwell, dot11OBSSScanPassiveTotalPerChannel, dot11OBSSScanActiveTotalPerChannel, dot112040BSSCoexistenceManagementSupport, dot11OBSSScanActivityThreshold, dot11SPPAMSDUCapable, dot11SPPAMSDURequired } STATUS deprecated DESCRIPTION "Superseded by dot11HTMACAdditions3. Attributes that configure the HT PHY for IEEE Std 802.11." ::= { dot11Groups 87 } dot11S1GTransmitBeamformingGroup OBJECT-GROUP OBJECTS { dot11S1GSUBeamformerOptionImplemented, dot11S1GSUBeamformeeOptionImplemented, dot11S1GMUBeamformerOptionImplemented, dot11S1GMUBeamformeeOptionImplemented, dot11S1GNumberSoundingDimensions, dot11S1GBeamformeeNTxSupport } STATUS current DESCRIPTION "Attributes that configure S1G transmit beamforming for IEEE 802.11." ::= { dot11Groups 88 } dot11PhyS1GComplianceGroup OBJECT-GROUP OBJECTS { dot11S1GChannelWidthOptionImplemented, dot11S1GCurrentPrimaryChannel, dot11S1GCurrentChannelWidth, dot11S1GCurrentChannelCenterFrequencyIndex, dot11ShortGIOptionIn1MImplemented, dot11ShortGIOptionIn1MActivated, dot11ShortGIOptionIn2MImplemented, dot11ShortGIOptionIn2MActivated, dot11ShortGIOptionIn4MImplemented, dot11ShortGIOptionIn4MActivated, dot11ShortGIOptionIn8MImplemented, dot11ShortGIOptionIn8MActivated, dot11ShortGIOptionIn16MImplemented, dot11ShortGIOptionIn16MActivated, dot11S1GLDPCCodingOptionImplemented, dot11S1GLDPCCodingOptionActivated, dot11S1GTxSTBCOptionImplemented, dot11S1GTxSTBCOptionActivated, dot11S1GRxSTBCOptionImplemented, dot11S1GRxSTBCOptionActivated, dot11S1GMUMaxUsersImplemented, dot11S1GMUMaxNSTSPerUserImplemented, dot11S1GMUMaxNSTSTotalImplemented, dot11S1GMaxNTxChainsImplemented, dot11S1GMaxNTxChainsActivated, dot11S1GTravelingPilotOptionImplemented, dot11S1GTravelingPilotOptionActivated, dot11S1GLONGOptionImplemented, dot11S1GLONGOptionActivated } STATUS current DESCRIPTION "Attributes that configure the S1G PHY." ::= { dot11Groups 89 } dot11S1GComplianceGroup OBJECT-GROUP OBJECTS { dot11S1GOptionImplemented, dot11S1GMaxMPDULength, dot11S1GMaxRxAMPDUFactor, dot11S1GControlFieldOptionImplemented, dot11S1GRxS1GMCSMap, dot11S1GTxS1GMCSMap, dot11S1GOBSSScanCount, dot11ShortBeaconInterval, dot11ShortBeaconPeriod, dot11ShortBeaconDTIMPeriod, dot11PV1MACHeaderOptionImplemented, dot11PV1ProbeResponseOptionImplemented, dot11HeaderCompressionResponseTimeout, dot11TSFTimerAccuracyImplemented, dot11NonTIMModeActivated, dot11PageSlicingImplemented, dot11PageSlicingActivated, dot11DynamicAIDActivated, dot11GroupAIDActivated, dot11AMSDUImplemented, dot11AMPDUImplemented, dot11MCSNegotiation, dot11AsymmetricBlockAckActivated, dot11FragmentBAOptionImplemented, dot11RAWOperationImplemented, dot11RAWOperationActivated, dot11S1GUplinkSyncOptionImplemented, dot11TWTOptionActivated, dot11BATImplemented, dot11PollTACKResponseImplemented, dot11NDPProbingActivated, dot11NDPPSPollSupport, dot11RelayAPImplemented, dot11RelayAPOperationActivated, dot11RelaySTAImplemented, dot11RelaySTAOperationActivated, dot11RelayDiscoveryOptionImplemented, dot11TXOPSharingImplicitACKImplemented, dot11S1GELOperationActivated, dot11S1GCentralizedAuthenticationControlActivated, dot11S1GDistributedAuthenticationControlActivated, dot11SubchannelSelectiveTransmissionActivated, dot11S1GSectorImplemented, dot11S1GSectorizationActivated, dot11S1GSectorTrainingOperationImplemented, dot11NDPBeamformingReportPollImplemented, dot11UnsolicitedDynamicAIDActivated, dot11TIMADEImplemented, dot11SelectiveSubchannelTransmissionPermitted, dot11MaxAwayDuration, dot11APPMActivated, dot11BDTImplemented, dot11S1GCACDeferral, dot11S1GCACThreshold, dot11S1GDACTac, dot11S1GDACTImin, dot11S1GDACTImax } STATUS current DESCRIPTION "Attributes that configure the S1G Group for IEEE 802.11." ::= { dot11Groups 90 } dot11FILSComplianceGroup OBJECT-GROUP OBJECTS { dot11FILSActivated, dot11FILSFDFrameBeaconMinimumInterval, dot11FILSFDFrameBeaconMaximumInterval, dot11FILSBeaconResponseWindow, dot11FILSOmitReplicateProbeResponses, dot11DILSImplemented, dot11FILSProbeDelay, dot11HLPWaitTime, dot11CacheIdentifier } STATUS current DESCRIPTION "The FILS Compliance group defines those objects that provide fast initial link setup for IEEE Std 802.11." ::= { dot11Groups 91 } -- dot11SMTbase13 includes all changes made between IEEE Std 802.11-2012 and IEEE Std 802.11-2016. -- Amendments to Std 802.11-2016 should not make any modifications to dot11SMTbase13. The first amendment needing to modify the dot11SMTbase object should deprecate dot11SMTbase13 and define a replacement to hold changes. dot11SMTbase13 OBJECT-GROUP OBJECTS { dot11MediumOccupancyLimit, dot11CFPollable, dot11CFPPeriod, dot11CFPMaxDuration, dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11SpectrumManagementImplemented, dot11SpectrumManagementRequired, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired, dot11QosOptionImplemented, dot11ImmediateBlockAckOptionImplemented, dot11DelayedBlockAckOptionImplemented, dot11DirectOptionImplemented, dot11APSDOptionImplemented, dot11QAckOptionImplemented, dot11QBSSLoadImplemented, dot11QueueRequestOptionImplemented, dot11TXOPRequestOptionImplemented, dot11MoreDataAckOptionImplemented, dot11AssociateInNQBSS, dot11DLSAllowedInQBSS, dot11DLSAllowed, dot11AssociateStation, dot11AssociateID, dot11AssociateFailStation, dot11AssociateFailStatus, dot11ReassociateStation, dot11ReassociateID, dot11ReassociateFailStation, dot11ReassociateFailStatus, dot11RadioMeasurementImplemented, dot11RadioMeasurementActivated, dot11RMMeasurementNavSync, dot11RMMeasurementPilotPeriod, dot11RMLinkMeasurementActivated, dot11RMNeighborReportActivated, dot11RMParallelMeasurementsActivated, dot11RMRepeatedMeasurementsActivated, dot11RMBeaconPassiveMeasurementActivated, dot11RMBeaconActiveMeasurementActivated, dot11RMBeaconTableMeasurementActivated, dot11RMBeaconMeasurementReportingConditionsActivated, dot11RMFrameMeasurementActivated, dot11RMChannelLoadMeasurementActivated, dot11RMNoiseHistogramMeasurementActivated, dot11RMStatisticsMeasurementActivated, dot11RMLCIMeasurementActivated, dot11RMLCIAzimuthActivated, dot11RMTransmitStreamCategoryMeasurementActivated, dot11RMTriggeredTransmitStreamCategoryMeasurementActivated, dot11RMAPChannelReportActivated, dot11RMMIBActivated, dot11RMMaxMeasurementDuration, dot11RMNonOperatingChannelMaxMeasurementDuration, dot11RMMeasurementPilotTransmissionInformationActivated, dot11RMMeasurementPilotActivated, dot11RMNeighborReportTSFOffsetActivated, dot11RMRCPIMeasurementActivated, dot11RMRSNIMeasurementActivated, dot11RMBSSAverageAccessDelayActivated, dot11RMBSSAvailableAdmissionCapacityActivated, dot11FastBSSTransitionImplemented, dot11LCIDSEImplemented, dot11LCIDSERequired, dot11DSERequired, dot11ExtendedChannelSwitchActivated, dot11HighThroughputOptionImplemented, dot11WirelessManagementImplemented, dot11MeshActivated, dot11RSNAPBACRequired, dot11PSMPOptionImplemented, dot11MaxMSDULength, dot11ExtendedSpectrumManagementImplemented, dot11EstimatedServiceParametersInboundOptionImplemented, dot11FutureChannelGuidanceActivated } STATUS deprecated DESCRIPTION " Superseded by dot11SMTbase15. The SMTbase13 object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network." ::= { dot11Groups 92 } dot11FineTimingMeasurement OBJECT-GROUP OBJECTS { dot11WirelessManagementImplemented, dot11FineTimingMsmtRespActivated, dot11FineTimingMsmtInitActivated, dot11LciCivicInNeighborReport, dot11RMFineTimingMsmtRangeRepImplemented, dot11RMFineTimingMsmtRangeRepActivated, dot11RMLCIMeasurementActivated, dot11RMLCIConfigured, dot11RMCivicMeasurementActivated, dot11RMCivicConfigured } STATUS current DESCRIPTION "Attributes that configure the Fine Timing Measurement feature for IEEE Std 802.11." ::= { dot11Groups 93 } dot11PADComplianceGroup OBJECT-GROUP OBJECTS { dot11SolicitedPADActivated, dot11UnsolicitedPADActivated } STATUS current DESCRIPTION "This object group provides the objects from the IEEE 802.11 MIB required to manage preassociation discovery functionality." ::= { dot11Groups 94 } dot11CDMGComplianceGroup OBJECT-GROUP OBJECTS { dot11CDMGOptionImplemented, dot11DynamicChannelTransferImplemented, dot11DynamicChannelTransferActivated, dot11CDMGSpatialsharingActivated, dot11CDMGClusteringActivated } STATUS deprecated DESCRIPTION "Superseded by dot11CDMGComplianceGroup1. Attributes that configure the CDMG Group for IEEE Std 802.11." ::= { dot11Groups 95 } dot11CDMGOperationsComplianceGroup OBJECT-GROUP OBJECTS {dot11DCSTimeout } STATUS current DESCRIPTION "Attributes that configure the CDMG Operation for IEEE Std 802.11." ::= { dot11Groups 96 } dot11CMMGComplianceGroup OBJECT-GROUP OBJECTS { dot11CMMGOptionImplemented, dot11CMMGClusteringActivated } STATUS current DESCRIPTION "Attributes that configure the CMMG Group for IEEE Std 802.11." ::= { dot11Groups 97 } dot11RSNBase2 OBJECT-GROUP OBJECTS { dot11RSNAConfigVersion, dot11RSNAConfigPairwiseKeysImplemented, dot11RSNAConfigGroupCipher, dot11RSNAConfigGroupRekeyMethod, dot11RSNAConfigGroupRekeyTime, dot11RSNAConfigGroupRekeyPackets, dot11RSNAConfigGroupRekeyStrict, dot11RSNAConfigPSKValue, dot11RSNAConfigPSKPassPhrase, dot11RSNAConfigGroupUpdateCount, dot11RSNAConfigPairwiseUpdateCount, dot11RSNAConfigGroupCipherSize, dot11RSNAConfigPairwiseCipherImplemented, dot11RSNAConfigPairwiseCipherActivated, dot11RSNAConfigPairwiseCipherSizeImplemented, dot11RSNAConfigAuthenticationSuiteImplemented, dot11RSNAConfigAuthenticationSuiteActivated, dot11RSNAConfigNumberOfPTKSAReplayCounters, dot11RSNAConfigSATimeout, dot11RSNAConfigNumberOfGTKSAReplayCounters, dot11RSNAAuthenticationSuiteSelected, dot11RSNAPairwiseCipherSelected, dot11RSNAGroupCipherSelected, dot11RSNAPMKIDUsed, dot11RSNAAuthenticationSuiteRequested, dot11RSNAPairwiseCipherRequested, dot11RSNAGroupCipherRequested, dot11RSNATKIPCounterMeasuresInvoked, dot11RSNA4WayHandshakeFailures, dot11RSNAStatsSTAAddress, dot11RSNAStatsVersion, dot11RSNAStatsSelectedPairwiseCipher, dot11RSNAStatsTKIPICVErrors, dot11RSNAStatsTKIPLocalMICFailures, dot11RSNAStatsTKIPRemoteMICFailures, dot11RSNAStatsCCMPReplays, dot11RSNAStatsCCMPDecryptErrors, dot11RSNAStatsTKIPReplays, dot11RSNAPreauthenticationImplemented, dot11RSNAStatsGCMPReplays, dot11RSNAStatsRobustMgmtGCMPReplays} STATUS current DESCRIPTION "The dot11RSNBase2 object class provides the necessary support for managing RSNA functionality in the STA." ::= { dot11Groups 104 } dot11HTMACAdditions3 OBJECT-GROUP OBJECTS { dot11MIMOPowerSave, dot11MaxAMSDULength, dot11STBCControlFrameOptionImplemented, dot11MaxRxAMPDUFactor, dot11MinimumMPDUStartSpacing, dot11TransitionTime, dot11MCSFeedbackOptionImplemented, dot11HTControlFieldSupported, dot11RDResponderOptionImplemented, dot11BSSWidthTriggerScanInterval, dot11BSSWidthChannelTransitionDelayFactor, dot11OBSSScanPassiveDwell, dot11OBSSScanActiveDwell, dot11OBSSScanPassiveTotalPerChannel, dot11OBSSScanActiveTotalPerChannel, dot112040BSSCoexistenceManagementSupport, dot11OBSSScanActivityThreshold, dot11SPPAMSDUCapable, dot11SPPAMSDURequired } STATUS current DESCRIPTION "Attributes that configure the HT PHY for IEEE Std 802.11." ::= { dot11Groups 105 } dot11SMTRMConfig2 OBJECT-GROUP OBJECTS { dot11APChannelReportIfIndex, dot11APChannelReportOperatingClass, dot11APChannelReportChannelList, dot11RMNeighborReportIfIndex, dot11RMNeighborReportBSSID, dot11RMNeighborReportAPReachability, dot11RMNeighborReportSecurity, dot11RMNeighborReportCapSpectrumMgmt, dot11RMNeighborReportCapQoS, dot11RMNeighborReportCapAPSD, dot11RMNeighborReportCapRM, dot11RMNeighborReportCapImmediateBlockAck, dot11RMNeighborReportKeyScope, dot11RMNeighborReportChannelNumber, dot11RMNeighborReportOperatingClass, dot11RMNeighborReportPhyType, dot11RMNeighborReportNeighborTSFInfo, dot11RMNeighborReportPilotInterval, dot11RMNeighborReportPilotMultipleBSSID, dot11RMNeighborReportRMEnabledCapabilities, dot11RMNeighborReportVendorSpecific, dot11RMNeighborReportRowStatus, dot11RMNeighborReportCapHT, dot11RMNeighborReportHTLDPCCodingCap, dot11RMNeighborReportHTSupportedChannelWidthSet, dot11RMNeighborReportHTSMPowerSave, dot11RMNeighborReportHTGreenfield, dot11RMNeighborReportHTShortGIfor20MHz, dot11RMNeighborReportHTShortGIfor40MHz, dot11RMNeighborReportHTTxSTBC, dot11RMNeighborReportHTRxSTBC, dot11RMNeighborReportHTDelayedBlockAck, dot11RMNeighborReportHTMaxAMSDULength, dot11RMNeighborReportHTDSSCCKModein40MHz, dot11RMNeighborReportHTFortyMHzIntolerant, dot11RMNeighborReportHTMaxAMPDULengthExponent, dot11RMNeighborReportHTMinMPDUStartSpacing, dot11RMNeighborReportHTRxMCSBitMask, dot11RMNeighborReportHTRxHighestSupportedDataRate, dot11RMNeighborReportHTTxMCSSetDefined, dot11RMNeighborReportHTTxRxMCSSetNotEqual, dot11RMNeighborReportHTTxMaxNumberSpatialStreamsSupported, dot11RMNeighborReportHTTxUnequalModulationSupported, dot11RMNeighborReportHTMCSFeedback, dot11RMNeighborReportHTCSupport, dot11RMNeighborReportHTRDResponder, dot11RMNeighborReportHTImplictTransmitBeamformingReceivingCap, dot11RMNeighborReportHTReceiveStaggeredSoundingCap, dot11RMNeighborReportHTTransmitStaggeredSoundingCap, dot11RMNeighborReportHTReceiveNDPCap, dot11RMNeighborReportHTTransmitNDPCap, dot11RMNeighborReportHTImplicitTransmitBeamformingCap, dot11RMNeighborReportHTTransmitBeamformingCalibration, dot11RMNeighborReportHTExplicitCSITransmitBeamformingCap, dot11RMNeighborReportHTExplicitNonCompressedSteeringCap, dot11RMNeighborReportHTExplicitCompressedSteeringCap, dot11RMNeighborReportHTExplicitTransmitBeamformingFeedback, dot11RMNbRprtHTExplicitNonCompressedBeamformingFeedbackCap, dot11RMNeighborReportHTExplicitCompressedBeamformingFeedbackCap, dot11RMNeighborReportHTTransmitBeamformingMinimalGrouping, dot11RMNbRprtHTCSINumberofTxBeamformingAntennasSuppt, dot11RMNbRprtHTNonCompressedSteeringNumofTxBmfmingAntennasSuppt, dot11RMNbRprtHTCompressedSteeringNumberofTxBmfmingAntennasSuppt, dot11RMNbRprtHTCSIMaxNumberofRowsTxBeamformingSuppt, dot11RMNeighborReportHTTransmitBeamformingChannelEstimationCap, dot11RMNeighborReportHTAntSelectionCap, dot11RMNeighborReportHTExplicitCSIFeedbackBasedTxASELCap, dot11RMNeighborReportHTAntIndicesFeedbackBasedTxASELCap, dot11RMNeighborReportHTExplicitCSIFeedbackBasedCap, dot11RMNeighborReportHTAntIndicesFeedbackCap, dot11RMNeighborReportHTRxASELCap, dot11RMNeighborReportHTTxSoundingPPDUsCap, dot11RMNeighborReportHTInfoPrimaryChannel, dot11RMNeighborReportHTInfoSecChannelOffset, dot11RMNeighborReportHTInfoSTAChannelWidth, dot11RMNeighborReportHTInfoRIFSMode, dot11RMNeighborReportHTInfoProtection, dot11RMNeighborReportHTInfoNonGreenfieldHTSTAsPresent, dot11RMNeighborReportHTInfoOBSSNonHTSTAsPresent, dot11RMNeighborReportHTInfoDualBeacon, dot11RMNeighborReportHTInfoDualCTSProtection, dot11RMNeighborReportHTInfoSTBCBeacon, dot11RMNeighborReportHTInfoBasicMCSSet, dot11RMNeighborReportHTSecChannelOffset, dot11RMNeighborReportExtCapPSMPSupport, dot11RMNeighborReportExtCapSPSMPSup, dot11RMNeighborReportExtCapServiceIntervalGranularity } STATUS current DESCRIPTION "Superseded by dot11SMTRMConfig3. The SMTRMConfig package is a set of attributes that are present if the STA supports the Radio Measurement service." ::= { dot11Groups 106 } dot11CountersGroup5 OBJECT-GROUP OBJECTS { dot11TransmittedFragmentCount, dot11TransmittedFrameCount, dot11FailedCount, dot11ReceivedFragmentCount, dot11GroupReceivedFrameCount, dot11FCSErrorCount, dot11WEPUndecryptableCount, dot11TransmittedFrameCount, dot11QosDiscardedFragmentCount, dot11AssociatedStationCount, dot11QosCFPollsReceivedCount, dot11QosCFPollsUnusedCount, dot11QosCFPollsUnusableCount, dot11QosCFPollsLostCount, dot11TransmittedAMSDUCount, dot11FailedAMSDUCount, dot11RetryAMSDUCount, dot11MultipleRetryAMSDUCount, dot11TransmittedOctetsInAMSDUCount, dot11AMSDUAckFailureCount, dot11ReceivedAMSDUCount, dot11ReceivedOctetsInAMSDUCount, dot11TransmittedAMPDUCount, dot11TransmittedMPDUsInAMPDUCount, dot11TransmittedOctetsInAMPDUCount, dot11AMPDUReceivedCount, dot11MPDUInReceivedAMPDUCount, dot11ReceivedOctetsInAMPDUCount, dot11AMPDUDelimiterCRCErrorCount, dot11ImplicitBARFailureCount, dot11ExplicitBARFailureCount, dot11ChannelWidthSwitchCount, dot11TwentyMHzFrameTransmittedCount, dot11FortyMHzFrameTransmittedCount, dot11TwentyMHzFrameReceivedCount, dot11FortyMHzFrameReceivedCount, dot11PSMPUTTGrantDuration, dot11PSMPUTTUsedDuration, dot11GrantedRDGUsedCount, dot11GrantedRDGUnusedCount, dot11TransmittedFramesInGrantedRDGCount, dot11TransmittedOctetsInGrantedRDGCount, dot11BeamformingFrameCount, dot11DualCTSSuccessCount, dot11DualCTSFailureCount, dot11STBCCTSSuccessCount, dot11STBCCTSFailureCount, dot11nonSTBCCTSSuccessCount, dot11nonSTBCCTSFailureCount, dot11TransmittedMSDUOctetsCount, dot11ReceivedMSDUOctetsCount } STATUS current DESCRIPTION "Attributes from the dot11CountersGroup that are not described in the dot11MACStatistics group. These objects are mandatory." ::= { dot11Groups 107 } dot11MACbase5 OBJECT-GROUP OBJECTS { dot11MACAddress, dot11GroupAddress, dot11GroupAddressesStatus, dot11RTSThreshold, dot11ShortRetryLimit, dot11FragmentationThreshold, dot11MaxTransmitMSDULifetime, dot11MaxReceiveLifetime, dot11ManufacturerID, dot11ProductID, dot11CAPLimit, dot11HCCWmin, dot11HCCWmax, dot11HCCAIFSN, dot11ChannelUtilizationBeaconIntervals, dot11ScheduleTimeout, dot11DLSResponseTimeout, dot11QAPMissingAckRetryLimit, dot11EDCAAveragingPeriod, dot11HTProtection, dot11RIFSMode, dot11PSMPControlledAccess, dot11ServiceIntervalGranularity, dot11DualCTSProtection, dot11NonGFEntitiesPresent} STATUS current DESCRIPTION "The MAC object class provides the necessary support for the access control, generation, and verification of frame check sequences (FCSs), and proper delivery of valid data to upper layers." ::= { dot11Groups 108 } dot11SMTbase15 OBJECT-GROUP OBJECTS { dot11PrivacyOptionImplemented, dot11PowerManagementMode, dot11DesiredSSID, dot11DesiredBSSType, dot11OperationalRateSet, dot11BeaconPeriod, dot11DTIMPeriod, dot11AssociationResponseTimeout, dot11DisassociateReason, dot11DisassociateStation, dot11DeauthenticateReason, dot11DeauthenticateStation, dot11AuthenticateFailStatus, dot11AuthenticateFailStation, dot11MultiDomainCapabilityImplemented, dot11MultiDomainCapabilityActivated, dot11CountryString, dot11SpectrumManagementImplemented, dot11SpectrumManagementRequired, dot11RSNAOptionImplemented, dot11OperatingClassesImplemented, dot11OperatingClassesRequired, dot11QosOptionImplemented, dot11ImmediateBlockAckOptionImplemented, dot11DirectOptionImplemented, dot11APSDOptionImplemented, dot11QAckOptionImplemented, dot11QBSSLoadImplemented, dot11QueueRequestOptionImplemented, dot11TXOPRequestOptionImplemented, dot11MoreDataAckOptionImplemented, dot11AssociateInNQBSS, dot11AssociateStation, dot11AssociateID, dot11AssociateFailStation, dot11AssociateFailStatus, dot11ReassociateStation, dot11ReassociateID, dot11ReassociateFailStation, dot11ReassociateFailStatus, dot11RadioMeasurementImplemented, dot11RadioMeasurementActivated, dot11RMMeasurementNavSync, dot11RMMeasurementPilotPeriod, dot11RMLinkMeasurementActivated, dot11RMNeighborReportActivated, dot11RMParallelMeasurementsActivated, dot11RMRepeatedMeasurementsActivated, dot11RMBeaconPassiveMeasurementActivated, dot11RMBeaconActiveMeasurementActivated, dot11RMBeaconTableMeasurementActivated, dot11RMBeaconMeasurementReportingConditionsActivated, dot11RMFrameMeasurementActivated, dot11RMChannelLoadMeasurementActivated, dot11RMNoiseHistogramMeasurementActivated, dot11RMStatisticsMeasurementActivated, dot11RMLCIMeasurementActivated, dot11RMLCIAzimuthActivated, dot11RMTransmitStreamCategoryMeasurementActivated, dot11RMTriggeredTransmitStreamCategoryMeasurementActivated, dot11RMAPChannelReportActivated, dot11RMMIBActivated, dot11RMMaxMeasurementDuration, dot11RMNonOperatingChannelMaxMeasurementDuration, dot11RMMeasurementPilotTransmissionInformationActivated, dot11RMMeasurementPilotActivated, dot11RMNeighborReportTSFOffsetActivated, dot11RMRCPIMeasurementActivated, dot11RMRSNIMeasurementActivated, dot11RMBSSAverageAccessDelayActivated, dot11RMBSSAvailableAdmissionCapacityActivated, dot11FastBSSTransitionImplemented, dot11LCIDSEImplemented, dot11LCIDSERequired, dot11DSERequired, dot11ExtendedChannelSwitchActivated, dot11HighThroughputOptionImplemented, dot11WirelessManagementImplemented, dot11MeshActivated, dot11RSNAPBACRequired, dot11PSMPOptionImplemented, dot11MaxMSDULength, dot11ExtendedSpectrumManagementImplemented, dot11EstimatedServiceParametersInboundOptionImplemented, dot11EstimatedServiceParametersOutboundOptionImplemented, dot11FutureChannelGuidanceActivated } STATUS current DESCRIPTION "The SMTbase15 object class provides the necessary support at the STA to manage the processes in the STA such that the STA may work cooperatively as a part of an IEEE 802.11 network." ::= { dot11Groups 109 } dot11SMTRMReport2 OBJECT-GROUP OBJECTS { dot11ChannelLoadRprtRqstToken, dot11ChannelLoadRprtIfIndex, dot11ChannelLoadMeasuringSTAAddr, dot11ChannelLoadRprtChanNumber, dot11ChannelLoadRprtOperatingClass, dot11ChannelLoadRprtActualStartTime, dot11ChannelLoadRprtMeasurementDuration, dot11ChannelLoadRprtChannelLoad, dot11ChannelLoadRprtVendorSpecific, dot11ChannelLoadRprtMeasurementMode, dot11NoiseHistogramRprtRqstToken, dot11NoiseHistogramRprtIfIndex, dot11NoiseHistogramMeasuringSTAAddr, dot11NoiseHistogramRprtChanNumber, dot11NoiseHistogramRprtOperatingClass, dot11NoiseHistogramRprtActualStartTime, dot11NoiseHistogramRprtMeasurementDuration, dot11NoiseHistogramRprtAntennaID, dot11NoiseHistogramRprtANPI, dot11NoiseHistogramRprtIPIDensity0, dot11NoiseHistogramRprtIPIDensity1, dot11NoiseHistogramRprtIPIDensity2, dot11NoiseHistogramRprtIPIDensity3, dot11NoiseHistogramRprtIPIDensity4, dot11NoiseHistogramRprtIPIDensity5, dot11NoiseHistogramRprtIPIDensity6, dot11NoiseHistogramRprtIPIDensity7, dot11NoiseHistogramRprtIPIDensity8, dot11NoiseHistogramRprtIPIDensity9, dot11NoiseHistogramRprtIPIDensity10, dot11NoiseHistogramRprtVendorSpecific, dot11NoiseHistogramRprtMeasurementMode, dot11BeaconRprtRqstToken, dot11BeaconRprtIfIndex, dot11BeaconMeasuringSTAAddr, dot11BeaconRprtChanNumber, dot11BeaconRprtOperatingClass, dot11BeaconRprtActualStartTime, dot11BeaconRprtMeasurementDuration, dot11BeaconRprtPhyType, dot11BeaconRprtReportedFrameType, dot11BeaconRprtRCPI, dot11BeaconRprtRSNI, dot11BeaconRprtBSSID, dot11BeaconRprtAntennaID, dot11BeaconRprtParentTSF, dot11BeaconRprtReportedFrameBody, dot11BeaconRprtVendorSpecific, dot11BeaconRprtMeasurementMode, dot11FrameRprtIfIndex, dot11FrameRprtRqstToken, dot11FrameRprtChanNumber, dot11FrameRprtOperatingClass, dot11FrameRprtActualStartTime, dot11FrameRprtMeasurementDuration, dot11FrameRprtTransmitSTAAddress, dot11FrameRprtBSSID, dot11FrameRprtPhyType, dot11FrameRprtAvgRCPI, dot11FrameRprtLastRSNI, dot11FrameRprtLastRCPI, dot11FrameRprtAntennaID, dot11FrameRprtNumberFrames, dot11FrameRprtVendorSpecific, dot11FrameRptMeasurementMode, dot11STAStatisticsReportToken, dot11STAStatisticsIfIndex, dot11STAStatisticsSTAAddress, dot11STAStatisticsMeasurementDuration, dot11STAStatisticsGroupID, dot11STAStatisticsTransmittedFragmentCount, dot11STAStatisticsGroupTransmittedFrameCount, dot11STAStatisticsFailedCount, dot11STAStatisticsRetryCount, dot11STAStatisticsMultipleRetryCount, dot11STAStatisticsFrameDuplicateCount, dot11STAStatisticsRTSSuccessCount, dot11STAStatisticsRTSFailureCount, dot11STAStatisticsAckFailureCount, dot11STAStatisticsQosTransmittedFragmentCount, dot11STAStatisticsQosFailedCount, dot11STAStatisticsQosRetryCount, dot11STAStatisticsQosMultipleRetryCount, dot11STAStatisticsQosFrameDuplicateCount, dot11STAStatisticsQosRTSSuccessCount, dot11STAStatisticsQosRTSFailureCount, dot11STAStatisticsQosAckFailureCount, dot11STAStatisticsQosReceivedFragmentCount, dot11STAStatisticsQosTransmittedFrameCount, dot11STAStatisticsQosDiscardedFrameCount, dot11STAStatisticsQosMPDUsReceivedCount, dot11STAStatisticsQosRetriesReceivedCount, dot11STAStatisticsReceivedFragmentCount, dot11STAStatisticsGroupReceivedFrameCount, dot11STAStatisticsFCSErrorCount, dot11STAStatisticsTransmittedFrameCount, dot11STAStatisticsAPAverageAccessDelay, dot11STAStatisticsAverageAccessDelayBestEffort, dot11STAStatisticsAverageAccessDelayBackground, dot11STAStatisticsAverageAccessDelayVideo, dot11STAStatisticsAverageAccessDelayVoice, dot11STAStatisticsStationCount, dot11STAStatisticsChannelUtilization, dot11STAStatisticsVendorSpecific, dot11STAStatisticsRprtMeasurementMode, dot11LCIReportToken, dot11LCIIfIndex, dot11LCISTAAddress, dot11LCILatitudeUncertainty, dot11LCILatitudeInteger, dot11LCILatitudeFraction, dot11LCILongitudeUncertainty, dot11LCILongitudeInteger, dot11LCILongitudeFraction, dot11LCIAltitudeType, dot11LCIAltitudeUncertainty, dot11LCIAltitude, dot11LCIDatum, dot11LCIAzimuthType, dot11LCIAzimuthResolution, dot11LCIAzimuth, dot11LCIVendorSpecific, dot11LCIRprtMeasurementMode, dot11TransmitStreamRprtRqstToken, dot11TransmitStreamRprtIfIndex, dot11TransmitStreamMeasuringSTAAddr, dot11TransmitStreamRprtActualStartTime, dot11TransmitStreamRprtMeasurementDuration, dot11TransmitStreamRprtPeerSTAAddress, dot11TransmitStreamRprtTID, dot11TransmitStreamRprtAverageQueueDelay, dot11TransmitStreamRprtAverageTransmitDelay, dot11TransmitStreamRprtTransmittedMSDUCount, dot11TransmitStreamRprtMSDUDiscardedCount, dot11TransmitStreamRprtMSDUFailedCount, dot11TransmitStreamRprtMultipleRetryCount, dot11TransmitStreamRprtBin0Range, dot11TransmitStreamRprtDelayHistogram, dot11TransmitStreamRprtReason, dot11TransmitStreamRprtVendorSpecific, dot11TransmitStreamRprtMeasurementMode } STATUS current DESCRIPTION "The SMTRMReport package is a set of attributes that are present if the STA supports the Radio Measurement service." ::= { dot11Groups 110 } dot11AVSBase2 OBJECT-GROUP OBJECTS { dot11RobustAVStreamingImplemented, dot11GCRActivated, dot11AdvancedGCRImplemented, dot11AdvancedGCRActivated, dot11SCSImplemented, dot11SCSActivated, dot11QLoadReportActivated, dot11AlternateEDCAActivated, dot11PublicHCCATXOPNegotiationActivated, dot11GCRGroupMembershipAnnouncementActivated, dot11MeshGCRImplemented, dot11MeshGCRActivated, dot11PublicHCCATXOPNegotiationImplemented, dot11PublicHCCATXOPNegotiationActivated, dot11ProtectedHCCATXOPNegotiationImplemented, dot11ProtectedHCCATXOPNegotiationActivated, dot11ProtectedQLoadReportImplemented, dot11ProtectedQLoadReportActivated, dot11QLoadReportIntervalDTIM, dot11HCCATXOPBeaconTimeout, dot11GCRConcealmentAddress, dot11GCRPolicyChangeTimeout, dot11QLoadReportDelay, dot11DefaultSurplusBandwidthAllowance, dot11ShortDEIRetryLimit, dot11UnsolicitedRetryLimit, dot11STAStatisticsAverageMSDUSizeVideo, dot11STAStatisticsAverageMSDUSizeVoice, dot11STAStatisticsAverageBitrateVideo, dot11STAStatisticsAverageBitrateVoice } STATUS current DESCRIPTION "The AVSBase package is a set of attributes that are present if the STA supports the robust audio video streaming features." ::= { dot11Groups 118 } dot11SMTRMConfig3 OBJECT-GROUP OBJECTS { dot11APChannelReportIfIndex, dot11APChannelReportOperatingClass, dot11APChannelReportChannelList, dot11RMNeighborReportIfIndex, dot11RMNeighborReportBSSID, dot11RMNeighborReportAPReachability, dot11RMNeighborReportSecurity, dot11RMNeighborReportCapSpectrumMgmt, dot11RMNeighborReportCapQoS, dot11RMNeighborReportCapAPSD, dot11RMNeighborReportCapRM, dot11RMNeighborReportCapImmediateBlockAck, dot11RMNeighborReportKeyScope, dot11RMNeighborReportChannelNumber, dot11RMNeighborReportOperatingClass, dot11RMNeighborReportPhyType, dot11RMNeighborReportNeighborTSFInfo, dot11RMNeighborReportPilotInterval, dot11RMNeighborReportPilotMultipleBSSID, dot11RMNeighborReportRMEnabledCapabilities, dot11RMNeighborReportVendorSpecific, dot11RMNeighborReportRowStatus, dot11RMNeighborReportCapHT, dot11RMNeighborReportHTLDPCCodingCap, dot11RMNeighborReportHTSupportedChannelWidthSet, dot11RMNeighborReportHTSMPowerSave, dot11RMNeighborReportHTGreenfield, dot11RMNeighborReportHTShortGIfor20MHz, dot11RMNeighborReportHTShortGIfor40MHz, dot11RMNeighborReportHTTxSTBC, dot11RMNeighborReportHTRxSTBC, dot11RMNeighborReportHTMaxAMSDULength, dot11RMNeighborReportHTDSSCCKModein40MHz, dot11RMNeighborReportHTFortyMHzIntolerant, dot11RMNeighborReportHTMaxAMPDULengthExponent, dot11RMNeighborReportHTMinMPDUStartSpacing, dot11RMNeighborReportHTRxMCSBitMask, dot11RMNeighborReportHTRxHighestSupportedDataRate, dot11RMNeighborReportHTTxMCSSetDefined, dot11RMNeighborReportHTTxRxMCSSetNotEqual, dot11RMNeighborReportHTTxMaxNumberSpatialStreamsSupported, dot11RMNeighborReportHTTxUnequalModulationSupported, dot11RMNeighborReportHTMCSFeedback, dot11RMNeighborReportHTCSupport, dot11RMNeighborReportHTRDResponder, dot11RMNeighborReportHTImplictTransmitBeamformingReceivingCap, dot11RMNeighborReportHTReceiveStaggeredSoundingCap, dot11RMNeighborReportHTTransmitStaggeredSoundingCap, dot11RMNeighborReportHTReceiveNDPCap, dot11RMNeighborReportHTTransmitNDPCap, dot11RMNeighborReportHTImplicitTransmitBeamformingCap, dot11RMNeighborReportHTTransmitBeamformingCalibration, dot11RMNeighborReportHTExplicitCSITransmitBeamformingCap, dot11RMNeighborReportHTExplicitNonCompressedSteeringCap, dot11RMNeighborReportHTExplicitCompressedSteeringCap, dot11RMNeighborReportHTExplicitTransmitBeamformingFeedback, dot11RMNbRprtHTExplicitNonCompressedBeamformingFeedbackCap, dot11RMNeighborReportHTExplicitCompressedBeamformingFeedbackCap, dot11RMNeighborReportHTTransmitBeamformingMinimalGrouping, dot11RMNbRprtHTCSINumberofTxBeamformingAntennasSuppt, dot11RMNbRprtHTNonCompressedSteeringNumofTxBmfmingAntennasSuppt, dot11RMNbRprtHTCompressedSteeringNumberofTxBmfmingAntennasSuppt, dot11RMNbRprtHTCSIMaxNumberofRowsTxBeamformingSuppt, dot11RMNeighborReportHTTransmitBeamformingChannelEstimationCap, dot11RMNeighborReportHTAntSelectionCap, dot11RMNeighborReportHTExplicitCSIFeedbackBasedTxASELCap, dot11RMNeighborReportHTAntIndicesFeedbackBasedTxASELCap, dot11RMNeighborReportHTExplicitCSIFeedbackBasedCap, dot11RMNeighborReportHTAntIndicesFeedbackCap, dot11RMNeighborReportHTRxASELCap, dot11RMNeighborReportHTTxSoundingPPDUsCap, dot11RMNeighborReportHTInfoPrimaryChannel, dot11RMNeighborReportHTInfoSecChannelOffset, dot11RMNeighborReportHTInfoSTAChannelWidth, dot11RMNeighborReportHTInfoRIFSMode, dot11RMNeighborReportHTInfoProtection, dot11RMNeighborReportHTInfoNonGreenfieldHTSTAsPresent, dot11RMNeighborReportHTInfoOBSSNonHTSTAsPresent, dot11RMNeighborReportHTInfoDualBeacon, dot11RMNeighborReportHTInfoDualCTSProtection, dot11RMNeighborReportHTInfoSTBCBeacon, dot11RMNeighborReportHTInfoBasicMCSSet, dot11RMNeighborReportHTSecChannelOffset, dot11RMNeighborReportExtCapPSMPSupport, dot11RMNeighborReportExtCapSPSMPSup, dot11RMNeighborReportExtCapServiceIntervalGranularity } STATUS current DESCRIPTION "The SMTRMConfig3 package is a set of attributes that are present if the STA supports the Radio Measurement service." ::= { dot11Groups 119 } dot11CDMGComplianceGroup1 OBJECT-GROUP OBJECTS { dot11CDMGOptionImplemented, dot11DynamicChannelTransferActivated, dot11OpportunisticTransmissionsImplemented } STATUS deprecated DESCRIPTION "Attributes that configure the CDMG Group for IEEE Std 802.11." ::= { dot11Groups 12 } -- ********************************************************************** -- * Compliance Statements -- ********************************************************************** dot11Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE 802.11 MIB." MODULE -- this module MANDATORY-GROUPS { dot11SMTbase15, dot11MACbase5, dot11CountersGroup5, dot11SmtAuthenticationAlgorithms, dot11ResourceTypeID, dot11PhyOperationComplianceGroup2} GROUP dot11PhyDSSSComplianceGroup DESCRIPTION "Implementation of this group is required when object dot11PHYType is dsss. This group is mutually exclusive to the following groups: dot11PhyOFDMComplianceGroup3 dot11PhyHRDSSSComplianceGroup dot11PhyERPComplianceGroup dot11PhyHTComplianceGroup dot11DMGComplianceGroup dot11PhyVHTComplianceGroup dot11PhyTVHTComplianceGroup dot11PhyS1GComplianceGroup dot11CDMGComplianceGroup1 dot11CMMGComplianceGroup" GROUP dot11PhyOFDMComplianceGroup3 DESCRIPTION "Implementation of this group is required when object dot11PHYType is ofdm. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyHRDSSSComplianceGroup dot11PhyERPComplianceGroup dot11PhyHTComplianceGroup dot11DMGComplianceGroup dot11PhyVHTComplianceGroup dot11PhyTVHTComplianceGroup dot11PhyS1GComplianceGroup dot11CDMGComplianceGroup1 dot11CMMGComplianceGroup" GROUP dot11PhyHRDSSSComplianceGroup DESCRIPTION "Implementation of this group is required when object dot11PHYType is hrdsss. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyOFDMComplianceGroup3 dot11PhyERPComplianceGroup dot11PhyHTComplianceGroup dot11DMGComplianceGroup dot11PhyVHTComplianceGroup dot11PhyTVHTComplianceGroup dot11PhyS1GComplianceGroup dot11CDMGComplianceGroup1 dot11CMMGComplianceGroup" GROUP dot11PhyERPComplianceGroup DESCRIPTION "Implementation of this group is required when object dot11PHYType is erp. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyOFDMComplianceGroup3 dot11PhyHRDSSSComplianceGroup dot11PhyHTComplianceGroup dot11DMGComplianceGroup dot11PhyVHTComplianceGroup dot11PhyTVHTComplianceGroup dot11PhyS1GComplianceGroup dot11CDMGComplianceGroup1 dot11CMMGComplianceGroup" GROUP dot11PhyHTComplianceGroup DESCRIPTION "Implementation of this group is required when object dot11PHYType is ht. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyOFDMComplianceGroup3 dot11PhyHRDSSSComplianceGroup dot11PhyERPComplianceGroup dot11DMGComplianceGroup dot11PhyVHTComplianceGroup dot11PhyTVHTComplianceGroup dot11PhyS1GComplianceGroup dot11CDMGComplianceGroup1 dot11CMMGComplianceGroup" GROUP dot11PhyVHTComplianceGroup DESCRIPTION "Implementation of this group is required when object dot11PHYType is vht. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyOFDMComplianceGroup3 dot11PhyHRDSSSComplianceGroup dot11PhyERPComplianceGroup dot11DMGComplianceGroup dot11PhyHTComplianceGroup dot11PhyTVHTComplianceGroup dot11PhyS1GComplianceGroup dot11CDMGComplianceGroup1 dot11CMMGComplianceGroup" GROUP dot11PhyTVHTComplianceGroup DESCRIPTION "Implementation of this group is required when object dot11PHYType is tvht. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyOFDMComplianceGroup3 dot11PhyHRDSSSComplianceGroup dot11PhyERPComplianceGroup dot11PhyHTComplianceGroup dot11DMGComplianceGroup dot11PhyVHTComplianceGroup dot11PhyS1GComplianceGroup dot11CDMGComplianceGroup1 dot11CMMGComplianceGroup" GROUP dot11PhyS1GComplianceGroup DESCRIPTION "Implementation of this group is required when object dot11PHYType is s1g. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyOFDMComplianceGroup3 dot11PhyHRDSSSComplianceGroup dot11PhyERPComplianceGroup dot11PhyHTComplianceGroup dot11DMGComplianceGroup dot11PhyVHTComplianceGroup dot11PhyTVHTComplianceGroup dot11CDMGComplianceGroup1 dot11CMMGComplianceGroup" GROUP dot11HTMACAdditions3 DESCRIPTION "The dot11HTMACAdditions3 group is optional." GROUP dot11SMTprivacy DESCRIPTION "The dot11SMTprivacy group is optional." GROUP dot11MACStatistics DESCRIPTION "The dot11MACStatistics group is optional." GROUP dot11PhyTxPowerComplianceGroup DESCRIPTION "The dot11PhyTxPowerComplianceGroup group is optional." GROUP dot11PhyTxPowerComplianceGroup2 DESCRIPTION "The dot11PhyTxPowerComplianceGroup2 group is optional, but dependent on dot11PhyTxPowerComplianceGroup." GROUP dot11PhyRegDomainsSupportGroup DESCRIPTION "The dot11PhyRegDomainsSupportGroup group is optional." GROUP dot11PhyAntennasListGroup DESCRIPTION "The dot11PhyAntennasListGroup group is optional." GROUP dot11PhyRateGroup DESCRIPTION "The dot11PhyRateGroup group is optional." GROUP dot11MultiDomainCapabilityGroup DESCRIPTION "The dot11MultiDomainCapabilityGroup group is optional." GROUP dot11RSNAadditions DESCRIPTION "The dot11RSNAadditions group is optional." GROUP dot11OperatingClassesGroup DESCRIPTION "The dot11OperatingClassesGroup group is optional." GROUP dot11Qosadditions DESCRIPTION "The dot11Qosadditions group is optional." GROUP dot11FTComplianceGroup DESCRIPTION "The dot11FTComplianceGroup group is optional." GROUP dot11PhyAntennaComplianceGroup2 DESCRIPTION "The dot11PhyAntennaComplianceGroup2 group is optional." GROUP dot11PhyMCSGroup DESCRIPTION "The dot11PhyMCSGroup group is optional." GROUP dot11TransmitBeamformingGroup DESCRIPTION "The dot11TransmitBeamformingGroup group is optional." GROUP dot11VHTTransmitBeamformingGroup DESCRIPTION "The dot11VHTTransmitBeamformingGroup group is optional." GROUP dot11VHTMACAdditions DESCRIPTION "The dot11VHTMACAdditions group is optional." GROUP dot11S1GTransmitBeamformingGroup DESCRIPTION "The dot11S1GTransmitBeamformingGroup group is optional." GROUP dot11S1GComplianceGroup DESCRIPTION "The dot11S1GComplianceGroup group is optional." GROUP dot11DMGComplianceGroup DESCRIPTION "Implementation of this group is required when the object dot11PHYType is dmg. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyOFDMComplianceGroup3 dot11PhyHRDSSSComplianceGroup dot11PhyERPComplianceGroup dot11PhyHTComplianceGroup dot11PhyVHTComplianceGroup dot11PhyTVHTComplianceGroup dot11PhyS1GComplianceGroup dot11CDMGComplianceGroup1 dot11CMMGComplianceGroup" GROUP dot11DMGOperationsComplianceGroup DESCRIPTION "DMG Operations Compliance Group" GROUP dot11DMGBeamformingComplianceGroup DESCRIPTION "DMG Beamforming Compliance Group" GROUP dot11DMGCountersComplianceGroup DESCRIPTION "DMG Counters Compliance Group." GROUP dot11TVWSComplianceGroup DESCRIPTION "The dot11TVWSComplianceGroup is optional." GROUP dot11BSSStatisticsGroup DESCRIPTION "Implementation of this group is optional by an AP." GROUP dot11FILSComplianceGroup DESCRIPTION "FILS Compliance Group." GROUP dot11CDMGComplianceGroup1 DESCRIPTION "Implementation of this group is required when the object dot11PHYType has the value of CDMG. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyOFDMComplianceGroup3 dot11PhyHRDSSSComplianceGroup dot11PhyERPComplianceGroup dot11PhyHTComplianceGroup dot11PhyVHTComplianceGroup dot11PhyTVHTComplianceGroup dot11PhyDMGComplianceGroup dot11PhyCMMGComplianceGroup" GROUP dot11CDMGOperationsComplianceGroup DESCRIPTION "CDMG Operations Compliance Group" GROUP dot11CMMGComplianceGroup DESCRIPTION "Implementation of this group is required when the object dot11PHYType has the value of CMMG. This group is mutually exclusive to the following groups: dot11PhyDSSSComplianceGroup dot11PhyOFDMComplianceGroup3 dot11PhyHRDSSSComplianceGroup dot11PhyERPComplianceGroup dot11PhyHTComplianceGroup dot11PhyVHTComplianceGroup dot11PhyTVHTComplianceGroup dot11PhyDMGComplianceGroup dot11PhyCDMGComplianceGroup" --GROUP dot11CMMGOperationsComplianceGroup --DESCRIPTION -- "CMMG Operations Compliance Group" -- OPTIONAL-GROUPS { -- dot11SMTprivacy, -- dot11MACStatistics, -- dot11PhyTxPowerComplianceGroup, -- dot11PhyRegDomainsSupportGroup, -- dot11PhyAntennasListGroup, -- dot11PhyRateGroup, -- dot11MultiDomainCapabilityGroup, -- dot11RSNAadditions, -- dot11OperatingClassesGroup, -- dot11Qosadditions, -- dot11RMCompliance, -- dot11FTComplianceGroup, -- dot11PhyAntennaComplianceGroup2, -- dot11HTMACadditions3, -- dot11PhyMCSGroup, -- dot11TransmitBeamformingGroup, -- dot11TVHTTransmitBeamformingGroup, -- dot11PhyTVHTComplianceGroup, -- dot11S1GTransmitBeamformingGroup, -- dot11PhyS1GComplianceGroup, -- dot11S1GComplianceGroup, -- dot11WNMCompliance, -- dot11BSSStatisticsGroup, -- dot11VHTTransmitBeamformingGroup, -- dot11PhyVHTComplianceGroup, -- dot11VHTMACAdditions, -- dot11TVWSComplianceGroup, -- dot11FILSComplianceGroup, -- dot11PADComplianceGroup} ::= { dot11Compliances 1 } -- ******************************************************************** -- * Compliance Statements - RSN -- ******************************************************************** dot11RSNCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE 802.11 RSN MIB." MODULE -- this module MANDATORY-GROUPS { dot11RSNBase2 } -- OPTIONAL-GROUPS { dot11RSNPMKcachingGroup } ::= { dot11Compliances 2 } -- ******************************************************************** -- * Compliance Statements - RM -- ******************************************************************** dot11RMCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE 802.11 MIB for Measurement Services." MODULE -- this module MANDATORY-GROUPS { dot11SMTRMRequest, dot11SMTRMReport, dot11SMTRMConfig3 } -- OPTIONAL-GROUPS { } ::= { dot11Compliances 3 } -- ******************************************************************** -- * Compliance Statements - Mesh -- ******************************************************************** dot11MeshCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE 802.11 MIB for Mesh." MODULE -- this module MANDATORY-GROUPS { dot11MeshComplianceGroup, dot11MeshHWMPComplianceGroup, dot11PasswordAuthComplianceGroup } -- OPTIONAL-GROUPS { dot11MeshOptionGroup } ::= { dot11Compliances 4 } -- ******************************************************************** -- * Compliance Statements - WNM -- ******************************************************************** dot11WNMCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION " This object class provides the objects from the IEEE 802.11 MIB required to manage wireless network management functionality. Note that additional objects for managing this functionality are located in the IEEE 802.11 WNM MIB." MODULE -- this module MANDATORY-GROUPS { dot11SMTRMRequest, dot11SMTRMReport, dot11SMTRMConfig3 } GROUP dot11SMTbase12 DESCRIPTION "At least the dot11WirelessManagementImplemented object is required from dot11SMTbase12" GROUP dot11FineTimingMeasurement DESCRIPTION "The dot11FineTimingMeasurement group is optional" OBJECT dot11WirelessManagementImplemented DESCRIPTION "Required object" ::= { dot11Compliances 5 } -- ******************************************************************** -- * Compliance Statements - QMF -- ******************************************************************** dot11QMFCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage QoS Management Frame functionality." MODULE -- this module MANDATORY-GROUPS { dot11QMFComplianceGroup } ::= { dot11Compliances 6 } -- ******************************************************************** -- * Compliance Statements - AVS -- ******************************************************************** dot11AVSCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE Std 802.11 Robust Audio/Video Streaming feature. Note that additional objects for managing this functionality are located in the IEEE 802.11 AVS MIB." MODULE -- this module GROUP dot11AVSBase2 DESCRIPTION "At least the dot11RobustAVStreamingImplemented object is required from dot11StationConfigEntry." OBJECT dot11RobustAVStreamingImplemented DESCRIPTION "Required object" ::= { dot11Compliances 7 } dot11AVSAPCCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE Std 802.11 HCCA TXOP Negotiation feature. Note that additional objects for managing this functionality are located in the IEEE 802.11 AVS MIB." MODULE -- this module MANDATORY-GROUPS { dot11AVSBase2 } GROUP dot11AVSAPCGroup DESCRIPTION "At least the dot11RobustAVStreamingImplemented object is required from dot11StationConfigEntry." OBJECT dot11RobustAVStreamingImplemented DESCRIPTION "Required object" ::= { dot11Compliances 8 } -- ******************************************************************* -- * Compliance Statements - DMG -- ******************************************************************* dot11DMGCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE 802.11 MIB for DMG operation." MODULE -- this module MANDATORY-GROUPS { dot11DMGComplianceGroup, dot11DMGOperationsComplianceGroup, dot11DMGBeamformingComplianceGroup, dot11DMGCountersComplianceGroup } ::= { dot11Compliances 9 } -- ******************************************************************** -- * Compliance Statements - Spectrum Management -- ******************************************************************** dot11SpectrumManagementCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB used to operate higher throughput." MODULE -- this module MANDATORY-GROUPS { dot11SpectrumManagementGroup } -- OPTIONAL-GROUPS { } ::= { dot11Compliances 10 } -- ******************************************************************** -- * Compliance Statements - Management frame protection -- ******************************************************************** dot11ProtectedManagementFrameCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to operate management frame protection." MODULE -- this module MANDATORY-GROUPS { dot11ProtectedManagementFrameGroup } -- OPTIONAL-GROUPS { } ::= { dot11Compliances 11 } -- ******************************************************************** -- * Compliance Statements - LCIDSE -- ******************************************************************** dot11LCIDSECompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to enable 3650-3700 MHz Operation in USA." MODULE -- this module MANDATORY-GROUPS { dot11LCIDSEGroup } -- OPTIONAL-GROUPS { } ::= { dot11Compliances 12 } -- ******************************************************************** -- * Compliance Statements - TDLS -- ******************************************************************** dot11TDLSCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage tunneled direct link setup." MODULE -- this module MANDATORY-GROUPS { dot11TDLSComplianceGroup } -- OPTIONAL-GROUPS { } ::= { dot11Compliances 13 } -- ******************************************************************** -- * Compliance Statements - VHT -- ******************************************************************** dot11VHTCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB used to operate at very high throughput." MODULE -- this module MANDATORY-GROUPS { dot11PhyVHTComplianceGroup, dot11PhyTxPowerComplianceGroup2, dot11VHTTransmitBeamformingGroup, dot11VHTMACAdditions } -- OPTIONAL-GROUPS { } ::= { dot11Compliances 14 } -- ******************************************************************** -- * Compliance Statements - TVWS -- ******************************************************************** dot11TVHTCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE 802.11 MIB for TVWS operation." MODULE -- this module MANDATORY-GROUPS { dot11PhyTVHTComplianceGroup, dot11PhyTxPowerComplianceGroup2, dot11TVHTTransmitBeamformingGroup, dot11VHTMACAdditions, dot11TVWSComplianceGroup } ::= { dot11Compliances 15 } -- ******************************************************************** -- * Compliance Statements - S1G -- ******************************************************************** dot11S1GCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB used to operate at sub 1 GHz." MODULE -- this module MANDATORY-GROUPS { dot11PhyS1GComplianceGroup, dot11PhyTxPowerComplianceGroup2, dot11S1GTransmitBeamformingGroup, dot11S1GComplianceGroup } -- OPTIONAL-GROUPS { } ::= { dot11Compliances 16 } -- ******************************************************************** -- * Compliance Statements - FILS -- ******************************************************************** dot11FILSCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE 802.11 MIB for FILS operation." MODULE -- this module MANDATORY-GROUPS { dot11FILSComplianceGroup } -- OPTIONAL-GROUPS { } ::= { dot11Compliances 17 } -- ********************************************************************** -- * Compliance Statements - CDMG -- ********************************************************************** dot11CDMGCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE Std 802.11 MIB for CDMG operation." MODULE -- this module MANDATORY-GROUPS { dot11CDMGComplianceGroup1, dot11CDMGOperationsComplianceGroup} ::= { dot11Compliances 18 } -- ********************************************************************** -- * Compliance Statements - CMMG -- ********************************************************************** dot11CMMGCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities that implement the IEEE Std 802.11 MIB for CMMG operation." MODULE -- this module MANDATORY-GROUPS { dot11CMMGComplianceGroup} --dot11CMMGOperationsComplianceGroup} ::= { dot11Compliances 19 } -- ******************************************************************** -- * Compliance Statements- PAD -- ******************************************************************** dot11PADCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage preassociation discovery functionality." MODULE -- this module MANDATORY-GROUPS { dot11PADComplianceGroup } ::= { dot11Compliances 20 } -- *************************************************************** -- * Compliance Statements - GLK -- *************************************************************** dot11GLKComplianceGroup OBJECT-GROUP OBJECTS { dot11GLKImplemented, dot11GLKRequired, dot11EPDImplemented, dot11EPDRequired, dot11GLKLinkRateSamples, dot11GLKLinkRateWindowSize, dot11GLKLinkRateWmin, dot11GLKLinkRateWavg, dot11GLKLinkRateWgeo, dot11GLKLinkRateScaling, dot11GLKLinkRateHysteresis, dot11GLKGCRImplemented } STATUS current DESCRIPTION "This object group provides the objects from the IEEE 802.11 MIB required to manage General Link functionality." ::= { dot11Groups 99 } dot11GLKCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "This object class provides the objects from the IEEE 802.11 MIB required to manage General Link functionality." MODULE -- this module MANDATORY-GROUPS { dot11GLKComplianceGroup } ::= { dot11Compliances 21 } -- ********************************************************************** -- * End of IEEE 802.11 MIB -- ********************************************************************** END