Hi all,

 

D0.2 says

The CRC field is transmitted from c4 to c7 with c7 first

 

But SFD says

The CRC bits of HE-SIG-A and each coding group of HE-SIG-B are generated as 4 LSB of HT CRC generator output.

[PHY Motion 105, January 2016, see [35]]

 

It seems contradictory of each other. Hence I want to make a clarification here that I will stick to the later motion as it is shown in D0.2. That is from c4 to c7 with c7 first.

 

Thanks Bin for pointing this issue out.

 

Regards

 

Ross

 

 