Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-11-TGBA] TGba ad-hoc meeting (4/17-18): call for submissions



Yunsong,

 

                Thanks for taking a look at the comment resolution.

 

                The issue raised in the comment is that “…multiple BSS sending the same WUR-SYNC signal would cause the WUR receivers listen to the wrong WUR wake-up messages and reduce their battery life.”

 

                STAs may detect a WUR PPDU from another BSS.   That is true even if we were to somehow change the preamble.   The WUR receiver will check the address fields and then determine that the PPDU is not intended for this STA.  So it will not wake-up the main radio.

 

                So in my personal opinion, this is not an issue.

 

                When we discuss this at the Ad Hoc, maybe we will choose to add some comments like this into the resolution.

 

Regards,

Steve

 

From: Yangyunsong <yangyunsong@xxxxxxxxxx>
Sent: Tuesday, April 16, 2019 11:53 AM
To: Steve Shellhammer <sshellha@xxxxxxxxxxxxxxxx>; STDS-802-11-TGBA@xxxxxxxxxxxxxxxxx
Subject: RE: [STDS-802-11-TGBA] TGba ad-hoc meeting (4/17-18): call for submissions

 

CAUTION: This email originated from outside of the organization.

Hi Steve,

Thank you for preparing doc. 11-19-0651r0. For CID 2776, I agree that the comment is an invalid comment as the commenter didn’t identify changes in sufficient detail so that the specific wording of the changes that will satisfy the commenter can be determined by the CRC.

 

However, comment resolution guideline (11-11-1625) suggests that

“Before rejecting any comment on the basis of its formal validity, the CRC should first consider whether there is, in fact, something that needs to be fixed.   If there is(,) the CRC should consider fixing it, regardless of the formal validity of the comment.   Failure to do so might simply cause delay, with the issue remaining for the next ballot.”

 

So, the question is: do we agree that the issue raised by the commenter is an issue?

 

Thanks,

Yunsong Yang

Futurewei Technologies

10180 Telesis Court, STE 400

San Diego, CA 92121

Phone: +1-858-754-3638

 

From: *** 802.11 TGba - WUR- Wake-up Radio Operation *** [mailto:STDS-802-11-TGBA@xxxxxxxxxxxxxxxxx] On Behalf Of Steve Shellhammer
Sent: Monday, April 15, 2019 3:05 PM
To: STDS-802-11-TGBA@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBA] TGba ad-hoc meeting (4/17-18): call for submissions

 

Minyoung,

 

                Here is one submission.  I will work on some more.

 

                802.11-19/651r1, CR on Sync Field Comments, Steve Shellhammer

 

Regards,

Steve

 

From: *** 802.11 TGba - WUR- Wake-up Radio Operation *** <STDS-802-11-TGBA@xxxxxxxxxxxxxxxxx> On Behalf Of Minyoung Park
Sent: Thursday, April 11, 2019 10:57 PM
To: STDS-802-11-TGBA@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBA] TGba ad-hoc meeting (4/17-18): call for submissions

 

CAUTION: This email originated from outside of the organization.

Dear all,

 

TGba ad-hoc meeting is scheduled next week, 4/17 and 4/18 as shown below. If you plan to attend in f2f but haven't responded to the epoll, please respond to the epoll so that I have a correct count.

 

Please send me the following information if you have submissions on the comment resolution on LB237.

  • DCN, title, presenter

Regards,

Minyoung

 

 

 

On Tue, Mar 19, 2019 at 2:30 PM Minyoung Park <mpark.ieee@xxxxxxxxx> wrote:

Dear all,

 

Please find the logistics for the ad-hoc meeting:

  • Dates: April 17-18, 2019
  • Location: Intel Santa Clara campus
  • Day 1 (April 17, Wednesday) 
  • Start/End time: 10:00 – 18:00 PT
  • RNB building
  • Address: 2200 Mission College Boulevard, Santa Clara, CA, 95054
  • Day 2 (April 18, Thursday)  
  • Start/End time: 9:00 – 18:00 PT
  • SC12 building
  • Address: 3600 Juliette Ln, Santa Clara, CA 95054

A conference call will be setup for the meetings.

 

Regards,

Minyoung

 

 