Hi Pei,


Thank you for your contribution.

 

I am still concerned about security. I don’t have a clear solution yet.

 

I have a few comments/suggestions embedded in the attached doc.

Could you please take a look?

Regards,
Abhi

 

From: ** STDS-802-11-TGbc -- Enhanced Broadcast Service ** <STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx> On Behalf Of ??(Zhou Pei)
Sent: Thursday, May 27, 2021 6:06 AM
To: STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBC]
答复: Discussion on EBCS Request ANQP-element

 

CAUTION: This email originated from outside of the organization.

Hi Mark,

 

Thanks for your comments.

 

> Thanks for the update.  I attach further comments.

Attached please find a revised version based on your comments. Please let me know If you have further comments.

I would be great if you can add your suggested content into our text proposal.

 

> Well, 11.100.5 is about responding to a notice of termination, where

obviously what you'd want to do is to extend the session.  I don't

think that means that all you can use the Requested Time To Termination

field is for extension.  As I said, if that's the case, I would like

to see that stated explicitly, and I'd also like to understand why

a stream should be kept running even if no-one is listening to it.

 

I agree that the Requested Time To Termination subfield can be used to extend and/or shorten the EBCS services.

I think both are OK, and I didnt put any restrictions in our text.

 

 

Best regards,

 

Pei Zhou

 

发件人: Mark Rison <m.rison@xxxxxxxxxxx>
发送时间: 2021527 19:54
收件人: 周培(Zhou Pei) <zhoupei1@xxxxxxxx>; Xiaofei.wang@xxxxxxxxxxxxxxxx; STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx
抄送: HUANG LEI <huang.lei1@xxxxxxxx>
主题: RE: Discussion on EBCS Request ANQP-element

 

Hello Pei,

 

> Attached please find a revised text proposal. Some updates are made based on Marks comments.

 

> Please let me know if you have further comments or if you have additional content to be added to the text proposal, thanks!

 

Thanks for the update.  I attach further comments.

 

> As for the case of using Time To Termination to extend the TTT, I found some related content in Clause 11.100.5 EBCS Termination Notice Procedure (page 58 of D1.02) attached below. I didnt find the case of using Time To Termination request to shorten the TTT as well.

 

Well, 11.100.5 is about responding to a notice of termination, where

obviously what you'd want to do is to extend the session.  I don't

think that means that all you can use the Requested Time To Termination

field is for extension.  As I said, if that's the case, I would like

to see that stated explicitly, and I'd also like to understand why

a stream should be kept running even if no-one is listening to it.

 

Thanks,

 

Mark

 

--

Mark RISON, Standards Architect, WLAN   English/Esperanto/Français

Samsung Cambridge Solution Centre       Tel: +44 1223  434600

Innovation Park, Cambridge CB4 0DS      Fax: +44 1223  434601

ROYAUME UNI                             WWW: http://www.samsung.com/uk

 

From: 周培(Zhou Pei) <zhoupei1@xxxxxxxx>
Sent: Thursday, 27 May 2021 02:53
To: Mark Rison <m.rison@xxxxxxxxxxx>; Xiaofei.wang@xxxxxxxxxxxxxxxx; STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx
Cc: HUANG LEI <huang.lei1@xxxxxxxx>
Subject:
答复: Discussion on EBCS Request ANQP-element

 

Hi Mark and Xiaofei,

 

Thank you for your valuable comments and discussions.

 

Attached please find a revised text proposal. Some updates are made based on Marks comments.

 

Please let me know if you have further comments or if you have additional content to be added to the text proposal, thanks!

 

As for the case of using Time To Termination to extend the TTT, I found some related content in Clause 11.100.5 EBCS Termination Notice Procedure (page 58 of D1.02) attached below. I didnt find the case of using Time To Termination request to shorten the TTT as well.

 

Best regards,

 

Pei Zhou

 

 

发件人: ** STDS-802-11-TGbc -- Enhanced Broadcast Service ** <STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx> 代表 Mark Rison
发送时间: 2021527 3:56
收件人: STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx
主题: Re: [STDS-802-11-TGBC] Discussion on EBCS Request ANQP-element

 

> I don’t think that in the existing spec we have discussed the case of using Time To Termination request to shorten the TTT, it has been used to extend the TTT, at least that is my impression. I suppose it is a case we can consider or we can be more specific about it in the protocol description. 

 

Hm, I've just grepped D1.02 and I can't find anything that indicates it's

only used to extend the duration of a TS.  Am I missing something?

 

If this is indeed the intent, then I think it definitely needs some words,

because to me it's very counter-intuitive (if there is only one subscriber

to a TS, and they've said they only need it for 5 more minutes, why would

you keep broadcasting it for the next hour?).

 

Thanks,

 

Mark

 

--

Mark RISON, Standards Architect, WLAN   English/Esperanto/Français

Samsung Cambridge Solution Centre       Tel: +44 1223  434600

Innovation Park, Cambridge CB4 0DS      Fax: +44 1223  434601

ROYAUME UNI                             WWW: http://www.samsung.com/uk

 


From: ** STDS-802-11-TGbc -- Enhanced Broadcast Service ** <STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx> on behalf of Mark Rison <m.rison@xxxxxxxxxxx>
Sent: Wednesday, May 26, 2021 7:26:03 AM
To: STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx <STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx>
Subject: Re: [STDS-802-11-TGBC] Discussion on EBCS Request ANQP-element

 



Thanks, Pei.  I attach my comments.

Also, this mechanism has no protection against an attacker causing
premature termination of an EBCS TS by forging an EBCS req ANQP-element
with a short Requested Time To Termination, right?

Thanks,

Mark

--
Mark RISON, Standards Architect, WLAN   English/Esperanto/Français
Samsung Cambridge Solution Centre       Tel: +44 1223  434600
Innovation Park, Cambridge CB4 0DS      Fax: +44 1223  434601
ROYAUME UNI                             WWW: http://www.samsung.com/uk


> -----Original Message-----
> From: ** STDS-802-11-TGbc -- Enhanced Broadcast Service ** <STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx> On
> Behalf Of ??(Zhou Pei)
> Sent: Wednesday, 26 May 2021 11:25
> To: STDS-802-11-TGBC@xxxxxxxxxxxxxxxxx
> Subject: [STDS-802-11-TGBC] Discussion on EBCS Request ANQP-element
>
> Hi all,
>
> I presented a contribution titled "Text Proposal for EBCS Request ANQP-element" (doc: 11-21-0600-02-
> 00bc-text-proposal-for-enhanced-broadcast-request-anqp-element) in the last teleconference.
> Some members raised the security issue of adding Requested Time to Termination subfield to the EBCS
> Request ANQP-element, since one unassociated non-AP STA may maliciously request a long time, which
> will have negative effects on the other non-AP STAs.
> I think this issue can be solved by limiting the time duration and/or frequency of ECBS services
> requested by unassociated non-AP STAs. That is to say, the EBCS transmitter of an EBCS has the
> authority to determine the time to termination of the EBCS.
>
> Attached pleased find a revised version of my proposal. I added a new Clause 11.100.5 EBCS Negotiation
> Procedure for Unassociated STAs.
> Please let me know if you have any comment, thanks!
>
>
> Best regards,
>
> Pei Zhou
> ________________________________
> OPPO
>
>
电子邮件及其附件含有OPPO公司的保密信息,仅限于邮件指明的收件人使用(包含个人及群组)。禁止任何人在未经授权的情况
>
下以任何形式使用。如果您错收了本邮件,请立即以电子邮件通知发件人并删除本邮件及其附件。
>
> This e-mail and its attachments contain confidential information from OPPO, which is intended only for
> the person or entity whose address is listed above. Any use of the information contained herein in any
> way (including, but not limited to, total or partial disclosure, reproduction, or dissemination) by
> persons other than the intended recipient(s) is prohibited. If you receive this e-mail in error,
> please notify the sender by phone or email immediately and delete it!
>
> ________________________________________________________________________
> To unsubscribe from the STDS-802-11-TGBC list, click the following link:
> https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBC&A=1

________________________________________________________________________
To unsubscribe from the STDS-802-11-TGBC list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBC&A=1


To unsubscribe from the STDS-802-11-TGBC list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBC&A=1

图像已被发件人删除。


To unsubscribe from the STDS-802-11-TGBC list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBC&A=1

图像已被发件人删除。

 


To unsubscribe from the STDS-802-11-TGBC list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBC&A=1