Hi Ron Thank you all for your comments. The PDT for DATA scrambler and descrambler is updated to r3 BRs Chenchen Liu 发件人: Ron Porat [mailto:ron.porat@xxxxxxxxxxxx]
Hi Chenchen, A few more comments: The SERVICE field of EHT PPDU:
propose to specifically say “EHT DATA field, ….” Since so far everything else had same scrambler and to avoid confusion. “when the all 1s initial state is used” - propose to revise to “when the all 1s initial state, set
by the 11 initialization bits as shown in figure 34-x, is used” “the 7 LSB bits of the SERVICE field shoud not be set to all zeros” - propose “the first 7 initialization