| Thread Links | Date Links | ||||
|---|---|---|---|---|---|
| Thread Prev | Thread Next | Thread Index | Date Prev | Date Next | Date Index | 
| 
 Dear all, Below SP in doc 11-20/1062r3 is failed in today’s MAC call. But I didn’t get people’s concern, it will be appreciate for the people who has concern
 to send me an e-mail. I am glad to have further discussion with you. 
•   
Do you agree that after two PPDUs with end time alignment are transmitted by a NSTR MLD on link 1 and link2 respectively, STA 1 affiliated
 with this NSTR MLD may use a greater than SIFS time interval between the ending of successful response frame and following PPDU within a TXOP on link1 when PHY-RXSTART.indication is received but FCS is not correct for response frame on link 2? 
– 
STA 1 shall transmit the following PPDU only if the CS mechanism indicates that the medium is idle; 
– 
The usage is to leave enough time for PIFS sensing on link 2; 
– 
Note: it is for R1 Regards, Yunbo To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1  |