Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-11-TGBE] Action item on proposed change of SFD subclauses related to OMN element and OM indication in A-control



Hello Wook Bong,

Thank you very much for your effort that I appreciate!!

re your request to be the TTT members, I will do on January 21 if I receive no objection as per the email I have sent (below).  

re EHT OM vs. Extended OM, I am sorry but I cannot comment as of now as I do not have a chance to read your contribution yet.   Maybe you would also discuss with Po-Kai, Liwen, and Young Hoon offline.

Regards,
Edward

On Fri, Jan 15, 2021 at 2:53 PM Wook Bong Lee <wookbong.lee@xxxxxxxxxxx> wrote:

Hi Edward, Po-Kai, Liwen and all,

 

I have a contribution related to this topic.

11-21/0102 Considerations on Capabilities and Operation Mode: MU-MIMO.

Will upload soon.

I feel that my contribution need to be discussed in PHY first, so I put it in the PHY queue for now.

Anyway plan is to present it in joint as well.

 

Second, I don’t know which one is better as a name, EHT OM or Extended OM as it could be used in future amendments.

 

Third, please add me in the TTT of both sections.

 

Thanks.

Best regards,

Wook Bong Lee

 

From: Edward Au [mailto:edward.ks.au@xxxxxxxxx]
Sent: Friday, January 15, 2021 7:11 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBE] Action item on proposed change of SFD subclauses related to OMN element and OM indication in A-control

 

Hello,


As discussed in the joint call yesterday, there is an action item for Po-Kai, Young Hoon, and me to locate an appropriate subclause (of the SFD) for operating mode notification element and operating mode indication in A-Control because both are better not included in subclause 5 of the SFD.

 

The following is a proposal suggested by Po-Kai and supported by Young Hoon.  Please do review and see if you have any comments.   I will update the SFD and volunteer assignment if I do not hear any concern by 11am ET, January 22, 2021 (Friday):

 

First, create the following subclause in SFD.
3 EHT MAC
3.5 operating mode
3.5.1 Operating mode notification element
3.5.2 Operating mode indication in A-ctrl

Second, change the location of the following motion from 12.2 EHT operation element to 3.5.1 Operating mode notification element in SFD
The EHT operating mode change is announced by adding the additional fields (EHT Channel Width, Additional EHT Rx Nss) to the Operating Mode Notification element.
[Motion 144, #SP328, [26] and [299]]

Third, Change the location of the following motion from 5.4 Operating mode indication of 5. Wideband and noncontiguous spectrum utilization to 3.5.2 Operating mode indication in A-ctrl in SFD
A new Control ID in A-Control is defined for EHT Operating mode (OM) that enables indication of 320 MHz, Tx NSTS larger than 8, and Rx NSS larger than 8.
Signaling TBD.
[Motion 137, #SP277, [3] and [167]]

Fourth, create a separate row of 3.5.1 Operating mode notification element and 3.5.2 Operating mode indication in A-ctrl in volunteer status document. Assign Liwen as the POC for 3.5.1, and Po-Kai to be the POC of 3.5.2.

Regards,
Edward