Hi Ruchen, Can you clarify why we need two different operating class in Annex E for 320-1 and 320-2?
I think the comment just wants to have some description of what is 320-1 and what is 320-2. You can add some description, which is similar as in SFD. In addition to four entries for 20/40/80/160MHz, there exists two entries in U-SIG BW field for 320 MHz:
・
320-1 if PPDU channel center frequency is 31, 95, 159.
・
320-2 if PPDU channel center frequency is 63, 127, 191.
[Motion 135, #SP237, [48] and [80]] regards 于健
Ross Jian Yu Huawei Technologies 发件人: Ruchen Duan [mailto:r.duan@xxxxxxxxxxx]
Hi, Alfred, Sigurd and Tianyu Please add the following document to the PHY queue.
https://mentor.ieee.org/802.11/dcn/21/11-21-0424-00-00be-cr-for-36-3-22-and-annex-e.doc
Thank you and best, Ruchen To unsubscribe from the STDS-802-11-TGBE list, click the following link: