Re: [STDS-802-11-TGBE] Feedback Requested for CRs related to NSTR operation - 11-21-0558r0



 

Hi Matthew,

 

I feel a bit of your warlike attitude on this doc not adding “please”, while your polite in the other one (21/530). :0

 

Anyway…

For CID 2980, I’ll say that the main load of cross-pair monitoring will be at the AP MLD, and when the AP MLD itself was able to initiate a TXOP on a non-anchor link, it can know without monitoring the links that it should not start nonsimultaneous transmission to the peer device of the NSTR link pair.

And the peer device cannot carrier sense on the anchor link while it is responding to the AP MLD on the non-anchor link, so it cannot initiate transmission on the anchor link.

 

Best regards,

tomo

 

From: Matthew Fischer <00000959766b2ff5-dmarc-request@xxxxxxxxxxxxxxxxx>
Sent: Tuesday, March 30, 2021 5:08 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBE] Feedback Requested for CRs related to NSTR operation - 11-21-0558r0

 


see:

 

 

Matthew Fischer

Nice Guy

Broadcom Inc.

+1 408 543 3370 office


This electronic communication and the information and any files transmitted with it, or attached to it, are confidential and are intended solely for the use of the individual or entity to whom it is addressed and may contain information that is confidential, legally privileged, protected by privacy laws, or otherwise restricted from disclosure to anyone else. If you are not the intended recipient or the person responsible for delivering the e-mail to the intended recipient, you are hereby notified that any use, copying, distributing, dissemination, forwarding, printing, or copying of this e-mail is strictly prohibited. If you received this e-mail in error, please return the e-mail to the sender, delete it from your computer, and destroy any printed copy of it.


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1