Hello Alfred,
 
Could you please add 21/1224r6 (CC 36 CR for Restricted TWT Setup) into the MAC agenda for running SP? 

Thanks,
Kumail
 


On Oct 13, 2021, at 10:38 AM, Abhishek Patil <appatil@xxxxxxxxxxxxxxxx> wrote:

 
Hi Ming, Laurent,
 
We must not increment the BPCC when the 5 elements listed in 35.3.10.2 (of D1.2) are updated on any link. Per 35.3.10.2, updates to any of these IEs for an affiliated AP will cause other (affiliated) APs to include the corresponding IE(s) in the ML IE carried in its Beacon & Probe Resp frame. As a result, the updated are directly available to the non-AP MLD on each link and don’t need to be part of the critical updates procedure.
 
I had submitted a comment to address this issue:
 
4064
Abhishek Patil
35.3.9
264.64
Since the 5 elements are directly included in the Beacon and Probe Response frame transmitted on other (reporting) links, these element should not cause the BSS Parameters Change Count subfield of the affected AP to increment. Add exception in clause 35.3.8 to exclude these elements. NOTE the element would still cause the Check Beacon field of the TIM frame to increment per baseline (see 11.2.3.15).
As in comment
 
Regards,
Abhi
 
 
From: Cariou, Laurent <laurent.cariou@xxxxxxxxx> 
Sent: Wednesday, October 13, 2021 5:54 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBE] 答复: [STDS-802-11-TGBE] TGbe Teleconferences [10/11/2021 and 10/13/2021]: Agenda Posted
 

WARNING: This email originated from outside of Qualcomm. Please be wary of any links or attachments, and do not enable macros.

Hi Ming,
Looks in the good direction for non-special scenarios. See attached some editorial to make things clearer.
 
For special scenario:
There is the case where the information of the critical updates are included in the frame on which the Critical Update flag is set (Quiet element, CSA, eCSA, …).
We need to see what is the procedure here: as the STA already received all the info of the critical update in the frame, it doesn’t make sense to be forced to retrieve one more time the information. We likely need a flag in that case that indicates that all info of the critical update is included in the frame. 
This will have impact on this procedure here so we need to address that.
Maybe one way is to add one condition, something like:
Unless the non-AP MLD has received the updated elements and fields corresponding to the critical update.
 
Thanks,
Laurent
 
 
From: Ganming(Ming Gan) <ming.gan@xxxxxxxxxx> 
Sent: Wednesday, October 13, 2021 2:25 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBE] 答复: [STDS-802-11-TGBE] 答复: [STDS-802-11-TGBE] TGbe Teleconferences [10/11/2021 and 10/13/2021]: Agenda Posted
 
Hi Alfred
 
Sorry, I made a mistake. The document # is not correct, it is 21/1443r0 CC36 CR for Retrieving Critical Update.
 
Best wishes
Ming
 
发件人: Ganming(Ming Gan) [mailto:ming.gan@xxxxxxxxxx] 
发送时间: 20211012 21:36
收件人: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
主题: [STDS-802-11-TGBE] 答复: [STDS-802-11-TGBE] TGbe Teleconferences [10/11/2021 and 10/13/2021]: Agenda Posted
 
Hello Alfred
 
Could your help add the SP for 21/1587r0  into the agenda? Thanks.
 
Best wishes
Ming Gan
发件人: Gaurang Naik [mailto:gnaik@xxxxxxxxxxxxxxxx] 
发送时间: 20211012 0:50
收件人: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
主题: Re: [STDS-802-11-TGBE] TGbe Teleconferences [10/11/2021 and 10/13/2021]: Agenda Posted
 
Hi Alfred,
 
Could you kindly add document 11-21/1659 to the MAC queue? 
 
All,
 
Document 11-21/1659 proposes a resolution for CID 4002 and is related to the inclusion of the ML element in Authentication frames. Kindly let me know if you have any feedback.
 
Thanks,
Gaurang
 
From: Alfred Asterjadhi <asterjadhi@xxxxxxxxx> 
Sent: Monday, October 11, 2021 9:33 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBE] TGbe Teleconferences [10/11/2021 and 10/13/2021]: Agenda Posted
 

WARNING: This email originated from outside of Qualcomm. Please be wary of any links or attachments, and do not enable macros.

Hello all,
 
I uploaded an updated version of the agendas, which contains the agenda for the next conference calls, scheduled on Monday October 11 (MAC/PHY), 19:00-21:00 ET and Wednesday October 13 (Joint), 10:00-12:00 ET.
 
The agendas can be found here:
 
Note for CR documents: Please update the baseline to TGbe D1.2 (available in the member's area) for the CR documents. Alternatively, please ensure that there are no conflicts between the proposed changes in the CR documents and TGbe D1.2.
 
DIAL IN DETAILS FOR MONDAY:
Meeting number: 234 895 70425 Meeting password: wireless (94735377 from phones and video systems)
 
Meeting number: 234 742 12243 Meeting password: wireless (94735377 from phones and video systems)
 
DIAL IN DETAILS FOR WEDNESDAY:
Meeting number: 233 296 78733 Meeting password: wireless (94735377 from phones and video systems)
 
Let me know if you have any questions and/or suggestions.
 
Best Regards,
 
Alfred
 
-- 
Alfred Asterjadhi, PhD
IEEE802.11 TGbe Chair,
Qualcomm Technologies Inc.
Cell #:    +1 858 263 9445
Office #: +1 858 658 5302

To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1

---------------------------------------------------------------------
Intel Corporation SAS (French simplified joint stock company)
Registered headquarters: "Les Montalets"- 2, rue de Paris, 
92196 Meudon Cedex, France
Registration Number:  302 456 199 R.C.S. NANTERRE
Capital: 4,572,000 Euros

This e-mail and any attachments may contain confidential material for
the sole use of the intended recipient(s). Any review or distribution
by others is strictly prohibited. If you are not the intended
recipient, please contact the sender and delete all copies.


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1



To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1