Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

[STDS-802-11-TGBE] 答复: CR on Trigger frame and puncturing



Hi Laurent,

 

Attached please find my comments. Basically OBSS PD spatial reuse met similar issues as PSR based spatial reuse, regarding the received signal strength level measurement. The STA which intends to do OBSS PD SR operation may have different bandwidth capability from the received PPDU bandwidth, the STA may also don’t know the exact puncture info of the received PPDU.

 

The proposed change is to follow PSR based spatial reuse, define the received signal strength level in dBm/20MHz. Then we solve the normalization issue for OBSS PD level too.

 

Please find the details in the attached doc.

 

Ross Jian Yu 于健

Huawei Technologies

 

发件人: Cariou, Laurent [mailto:laurent.cariou@xxxxxxxxx]
发送时间: 202229 0:08
收件人: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
主题: Re: [STDS-802-11-TGBE] CR on Trigger frame and puncturing

 

Hi Alfred,

Can you please add 22/0083r0 to the joint queue?

Thanks,

Laurent

 

 

From: Yanjun Sun <yanjuns@xxxxxxxxxxxxxxxx>
Sent: Tuesday, February 8, 2022 3:32 AM
To: STDS-802-11-TGBE@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBE] CR on Trigger frame and puncturing

 

Hi Alfred and all,

 

Could you help add 22/0237r0 to the joint queue?

 

The changes are mostly editorial for clarifications and please let me know if you have any comments/suggestions.

 

Thanks

Yanjun

 


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1

---------------------------------------------------------------------
Intel Corporation SAS (French simplified joint stock company)
Registered headquarters: "Les Montalets"- 2, rue de Paris,
92196 Meudon Cedex, France
Registration Number:  302 456 199 R.C.S. NANTERRE
Capital: 4,572,000 Euros

This e-mail and any attachments may contain confidential material for
the sole use of the intended recipient(s). Any review or distribution
by others is strictly prohibited. If you are not the intended
recipient, please contact the sender and delete all copies.


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1


To unsubscribe from the STDS-802-11-TGBE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBE&A=1

Attachment: 11-22-0083-00-00be-cc36-resolution-to-cids-for-35-9-rossyu.docx