With the Target TWT Wake Time referring to the TSF time of the link where the TWT Setup frame is transmitted, the frame content of frame needs to be changed if the retransmission
of the frame is in a different link. Is it possible to refer the start time to a fixed link? Best Regards, Liwen From: Ganming(Ming Gan) <000017d5b1a95115-dmarc-request@xxxxxxxxxxxxxxxxx>
Caution:
EXT Email
Thanks Minyoung. The following text sounds good to me. 发件人:
Minyoung Park [mailto:mpark.ieee@xxxxxxxxx]
Hi Ming, If I understand correctly, what you want is to derive the TWT times of the other links from the TWT time indicated in the TWT element transmitted on one of the links so that the TWT start times across multiple links are aligned. Maybe better
to spell that out as follows? "• If multiple links are indicated in the Link ID Bitmap subfield of the TWT element, then multiple TWT agreements are requested to be setup; A TWT agreement is requested on behalf of each of the STAs affiliated
with the same MLD and that is operating on each of the indicated links.
Regards, Minyoung On Mon, Apr 25, 2022 at 12:41 AM Ganming(Ming Gan) <000017d5b1a95115-dmarc-request@xxxxxxxxxxxxxxxxx> wrote:
To unsubscribe from the STDS-802-11-TGBE list, click the following link: