Hi Jinyoung, Thanks for deferring this CID, and providing the explanation. But an EHT STA can support HT/VHT/HE/EHT PPDU, so no reason to disallow HT/VHT variant of HT control. So I don’t agree
with the comment. Regards, Yunbo 发件人: Jinyoung Chun [mailto:jiny.chun@xxxxxxx]
Hi, Yunbo and Abdel, RDG/More PPDU subfield is in HT control for HT/VHT variant, and in CAS control among A-Control for HE variant as below. The target STA in a MU-RTS TXS Trigger frame, that is newly defined, is an EHT STA. So RDG/More PPDU subfield for the target STA in a MU-RTS TXS Trigger
frame is present in the CAS Control subfield as below resolution.