Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: [STDS-802-11-TGBF] TGbf Teleconference on January 12, 13, 14 (Tuesday, Wednesday, Thursday), 9:00 – 11:00am ET



Hi Tony,

 

The correct wording format for the motion text should be as follows. Sorry for the confusion.

 

Motion 1:

Move to add the following to 11bf SFD:  

A sensing procedure allows a STA to perform WLAN sensing and obtain measurement results. A sensing session is an instance of a sensing procedure with associated operational parameters of that instance.

 

Motion 2:

Move to add the following to 11bf SFD:  

    • Sensing initiator and sensing responder
      • Sensing initiator: a STA that initiates a WLAN sensing session
      • Sensing responder: a STA that participates in a WLAN sensing session initiated by a sensing initiator
    • Sensing transmitter and sensing receiver
      • Sensing transmitter: a STA that transmits PPDUs used for sensing measurements in a sensing session
      • Sensing receiver: a STA that receives PPDUs sent by a sensing transmitter and performs sensing measurements in a sensing session
    • A STA can assume multiple roles in one sensing session.

 

Best,

Cheng

 

 

 

 

 

From: Chen, Cheng <cheng.chen@xxxxxxxxx>
Sent: Thursday, January 14, 2021 6:38 AM
To: Chen, Cheng <cheng.chen@xxxxxxxxx>; STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: RE: TGbf Teleconference on January 12, 13, 14 (Tuesday, Wednesday, Thursday), 9:00 – 11:00am ET

 

Here is the requested Motion text corresponding to the two SPs:

  • Do you agree with the following definitions?
    • A sensing procedure allows a STA to perform WLAN sensing and obtain measurement results. A sensing session is an instance of a sensing procedure with associated operational parameters of that instance.

 

  • Do you agree with the following definitions?
    • Sensing initiator and sensing responder
      • Sensing initiator: a STA that initiates a WLAN sensing session
      • Sensing responder: a STA that participates in a WLAN sensing session initiated by a sensing initiator
    • Sensing transmitter and sensing receiver
      • Sensing transmitter: a STA that transmits PPDUs used for sensing measurements in a sensing session
      • Sensing receiver: a STA that receives PPDUs sent by a sensing transmitter and performs sensing measurements in a sensing session
    • A STA can assume multiple roles in one sensing session.

Best,

Cheng

 

 

From: Chen, Cheng <cheng.chen@xxxxxxxxx>
Sent: Thursday, January 14, 2021 6:23 AM
To: STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-11-TGBF] TGbf Teleconference on January 12, 13, 14 (Tuesday, Wednesday, Thursday), 9:00 – 11:00am ET

 

Hi Tony,

 

I would like to submit a motion request to run the motions corresponding to the two SPs I already ran in contribution 20/1849r4. Please queue them in the agenda of the next applicable 11bf call. Thanks.

 

Best,

Cheng

 

From: Hanxiao (Tony, WT Lab) <tony.hanxiao@xxxxxxxxxx>
Sent: Tuesday, January 5, 2021 11:56 PM
To: STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBF] TGbf Teleconference on January 12, 13, 14 (Tuesday, Wednesday, Thursday), 9:00 – 11:00am ET

 

Dear all,

This is a reminder and call for submissions for the upcoming teleconference call on January 12, 13, 14 (Tuesday, Wednesday, Thursday), 9:00 – 11:00am ET

 

         The initial agenda document is posted:

                  https://mentor.ieee.org/802.11/dcn/20/11-20-1913-01-00bf-tgbf-meeting-agenda-2021-01-interim.pptx

 

Please note:

  1. Please send the agenda request at least 24 hours prior to the call, following the format below:

     DCN, Title, Author (affiliation), Time duration

  1. I will cancel the call if there is no request received 24 hours prior to a call.
  2. Please upload your submissions (revision 0) on mentor 24 hours prior to the meeting so that members would have a chance to review those submissions offline. Otherwise,
    1. If there is not enough time during the meeting, the presentation will be delayed to the next meeting.
    2. If there is enough time during the meeting, the presentation will be moved to the end of the queue and be presented in the end. However, any related SP should be delayed to the next meeting.
  3. Please send the motion request around 10+5 days before the meeting, so that the TG chair could send the 10 day advance notice to the 802.11 reflector, after getting the approval from the WG chair.
  4. Dial-in information:

January 12

Join the Webex meeting here: https://ieeesa.webex.com/ieeesa/j.php?MTID=mb0af2f51edcf22cba8985233a15fb0bd

Meeting number: 179 993 7016

Meeting password: wireless (94735377 from phones and video systems)

Join by phone: Tap to call in from a mobile device (attendees only) +1-408-418-9388 USA Toll
Global call-in numbers

Access code: 179 993 7016

Join from a video system or application Dial 1799937016@xxxxxxxxxxxxxxxx You can also dial 173.243.2.68 and enter your meeting number.

Join using Microsoft Lync or Microsoft Skype for Business Dial 1799937016.ieeesa@xxxxxxxxxxxxxx

Need help? Go to http://help.webex.com

 

January 13

Join the Webex meeting here: https://ieeesa.webex.com/ieeesa/j.php?MTID=m171f78292b0ce217d180b564d62df15d

Meeting number: 179 489 9044

Meeting password: wireless (94735377 from phones and video systems)

Join by phone: Tap to call in from a mobile device (attendees only) +1-408-418-9388 USA Toll
Global call-in numbers

Access code: 179 489 9044

Join from a video system or application Dial 1794899044@xxxxxxxxxxxxxxxx You can also dial 173.243.2.68 and enter your meeting number.

Join using Microsoft Lync or Microsoft Skype for Business Dial 1794899044.ieeesa@xxxxxxxxxxxxxx

Need help? Go to http://help.webex.com

 

January 14

Join the Webex meeting here: https://ieeesa.webex.com/ieeesa/j.php?MTID=md2fbbbefb05455ccbc2577f414c52607

Meeting number: 179 669 2289

Meeting password: wireless (94735377 from phones and video systems)

Join by phone: Tap to call in from a mobile device (attendees only) +1-408-418-9388 USA Toll
Global call-in numbers

Access code: 179 669 2289

Join from a video system or application Dial 1796692289@xxxxxxxxxxxxxxxx You can also dial 173.243.2.68 and enter your meeting number.

Join using Microsoft Lync or Microsoft Skype for Business Dial 1796692289.ieeesa@xxxxxxxxxxxxxx

Need help? Go to http://help.webex.com

 

 

Best Regards : )

Tony Xiao Han


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1