Re: [STDS-802-11-TGBF] Updated PDT for Sensing Measurement Setup Procedure and Frame Format



Insun,

The text
"Request denied because the requested sensing measurement setup is unacceptable, but suggests a preferred sensing measurement parameters that will be acceptable" 
in Table 9.78 Status codes are misleading. Suggest to change to
Request denied because the requested sensing measurement setup is unacceptable,; but suggests a set of preferred and acceptable sensing measurement parameters that will be acceptableare suggested.

Thanks,
Oscar

On Thu, Feb 24, 2022 at 7:36 PM 장인선 <insun.jang@xxxxxxx> wrote:

Hi TTT members and All

 

I’ve revised and uploaded the PDT for sensing measurement setup procedure and frame format based on additional comments in the call/offline.

https://mentor.ieee.org/802.11/dcn/22/11-22-0229-02-00bf-pdt-for-sensing-measurement-setup.docx

It mainly changed the format of measurement setup frames by adding “subtype” field and the existing “Status Code” field in baseline

 

Please let me know if you have further comments on the PDT.

 

Thanks

Best Regards

Insun

 

From: 장인선 [mailto:insun.jang@xxxxxxx]
Sent: Friday, February 18, 2022 1:57 PM
To: 'STDS-802-11-TGBF@xxxxxxxxxxxxxxxxx'
Subject: Updated PDT for Sensing Measurement Setup Procedure and Frame Format

 

Hi All

 

I’ve revised and uploaded the PDT for sensing measurement setup procedure and frame format based on the comments in the call/offline.

https://mentor.ieee.org/802.11/dcn/22/11-22-0229-01-00bf-pdt-for-sensing-measurement-setup.docx

Please let me know if you have further comments on the PDT

 

Thanks

Best Regards

Insun


To unsubscribe from the STDS-802-11-TGBF list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBF&A=1