Thankyou Antonio, for pointing out the need to address the failure cases where Device ID and IRM checks produce different outcomes. The added text still doesn't inform the implementer what behavior is expected. Saying they are not linked still can produce
different results, with different potentially conflicting actions. Is the intention that it be implementation specific which is given precedence? Or am I incorrect in thinking there is a conflict in behavior?
Thanks for clarifying.
Ben
From: ANTONIO DE LA OLIVA DELGADO <aoliva@xxxxxxxxxx>
Sent: Thursday, July 27, 2023 11:44 PM To: STDS-802-11-TGBH@xxxxxxxxxxxxxxxxx <STDS-802-11-TGBH@xxxxxxxxxxxxxxxxx> Subject: [STDS-802-11-TGBH] CIDs 23, 135 and 224 Dear all,
as promised during the last AC I am providing new text for the resolution of these CIDs.
Current text agreed during comment resolution for these CIDs is the following:
I think this explanation lacks information on how to proceed if both mechanisms while used concurrently yield to different results. In addition, the above paragraph seems to indicate IRM provides identification, while it is not. I am proposing the following text, let me know what do you think
NOTE: Device ID and IRM are independent schemes that can be used concurrently. The device ID is allocated by an AP, and enables identification of the STA during association. IRM enables an AP to recognize that a STA has been associated previously to the AP, therefore not providing any identification. If an AP and a non-AP STA both support both IRM and device ID, the non-AP STA might provide both an IRM and a device ID. Both mechanisms are not related and their failure or success is not linked. Br
Antonio
--
Antonio de la Oliva
Associate Professor
Telematics Department Universidad Carlos III de Madrid E-mail: aoliva@xxxxxxxxxx Phone: +34 91 624 8803 Fax: +34 91 624 8749 To unsubscribe from the STDS-802-11-TGBH list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBH&A=1 To unsubscribe from the STDS-802-11-TGBH list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBH&A=1 |