Hi Alfred,

 

Could you please add the following SPs to the agenda? Thanks!

 

SP1: Do you support to include in the 11bn SFD:

  • In Coordinated Spatial Reuse:
    • An AP that intends to initiate a Coordinated Spatial Reuse transmission shall transmit a Trigger frame to initiate concurrent CSR transmissions with one other AP within its obtained TXOP BW;
    • When all addressed non-AP STAs are UHR STAs, the concurrent CSR transmission starts SIFS after the Trigger frame
    • Which trigger frame is TBD

Note-it is TBD whether to allow more than one other AP to be identified by the Trigger frame

Supporting document: 11-23/1868

 

SP2: Do you support to include in the 11bn SFD:

  • In Coordinated Spatial Reuse, the following information shall be carried in the Trigger frame that initiates concurrent CSR transmissions of the 2 APs
    • The duration of the data PPDU transmitted by the sharing AP and of the data PPDU transmitted by the shared AP, which are the same, after the Trigger frame
    • Other parameters TBD

Supporting document: 11-23/1868

 

Best,

Jason

 

 

发件人: Frank Hsu (徐建芳) <00001a0499b52dff-dmarc-request@xxxxxxxxxxxxxxxxx>
发送时间: 2025112 21:29
收件人: STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx
主题: Re: [STDS-802-11-TGBN] Updated TGbn Agenda Posted

 

Hi, Alfred,

 

Could you help to add the SP as below to a MAC session on Tuesday?

 

     Do you agree to define an Enhanced BSR Control subfield in A-ctrl to report a larger per TID queue size?

     The Enhanced BSR Control subfield consists of at least a TID subfield and an unsigned value subfield to report the larger queue size (QS) of the TID

     The reported QS is equal to 2147328 Octets + the value reported in the Queue Size field of the defined Enhanced BSR Control subfield

     When the QoS Control with the same TID as the Enhanced BSR Control subfield is present in the same MPDU, the QS subfield of the QoS Control is set to value 254

     TBD if the Enhanced BSR Control subfield shares the control ID with other Control subfield proposals in UHR

     Note: The baseline rules which regulate HT control field to be the same in all MPDUs of the same frame type in an A-MPDU do not change

     Note: Encoding of the baseline QS subfield in QoS Control does not change.

     Note: Length of the Enhanced BSR Control subfield allows to aggregate the UPH in the same A-Control subfield

 

Reference documents: 11-24/0963, 11-23/2007

 

Thank you!

 

BRs,

Frank

 

From: Alfred Asterjadhi <asterjadhi@xxxxxxxxx>
Sent: Sunday, January 12, 2025 6:00 PM
To: STDS-802-11-TGBN@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-11-TGBN] Updated TGbn Agenda Posted

 

External email : Please do not click links or open attachments until you have verified the sender or the content.

Hello all,

 

I posted an updated version of the agenda (here).

 

It contains the most up to data queues and the allocations for the week. Please review and let me know if I have missed anything. 

 

PS: I have yet to populate the SPs with the usual format for PHY/MAC/Joint. I expect to do so for the next revision of the agenda.

 

Regards,


Alfred

 

--

Alfred Asterjadhi, PhD

IEEE802.11 TGbe/TGbn Chair,

Qualcomm Technologies Inc.

Cell #:    +1 858 263 9445

Office #: +1 858 658 5302


To unsubscribe from the STDS-802-11-TGBN list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBN&A=1


To unsubscribe from the STDS-802-11-TGBN list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBN&A=1


To unsubscribe from the STDS-802-11-TGBN list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGBN&A=1