Discussion:
A definition of the basic rate set (and ditto basic MCS set) is indeed needed, as currently the meaning is not explicitly defined. There are several points to be clear on:
The basic rate set is selected at BSS start (that is the only place where it can be passed over the MLME SAP) and hence is fixed for the lifetime of the BSS
All STAs in the BSS are expected to support tx and rx of all rates in the basic rate set (though for Class 2 STAs this might not in fact be the case)
There are requirements on APs and PCPs to deny association to STAs that don’t declare support for all the rates in the basic rate set (11.3.5.3/5), and ditto mesh STAs to deny mesh peering (10.6.4 and 14.3.6.2)
The basic rate set is independent of the mandatory rates for the PHY of the STA that started the BSS (this is already specified). Similarly, the operational rate set, already defined as “[the] set of data rates that a station (STA) is capable of receiving”, is independent of the mandatory rates of the STA
To unsubscribe from the STDS-802-11-TGM list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-11-TGM&A=1