According to the Table:309 of the 802.16-2004 specification, the variable and constant pilots collide for the odd numbered FUSC symbols. There are collisions at the following subcarriers when the variable pilots are offset by +6.
726
1158
342
918
1206
330
522
1530Could you please direct me to the resolution of this problem or the preferred alternative.