[10GBT] Nov. '04 presentation golden_1_1104.pdf




Re: Nov. '04 presentation golden_1_1104.pdf

  * The ordering of slides 4 and 5 may be confusing. They will be presented
    in the opposite order.

  * The attached plot may help to clarify the results shown on slides 4 & 5:
    In contrast to slide 4 (which shows slicer SNR vs. length for a given
    THP filter, with the power held constant at the power backoff value
    appropriate for that filter), this plot shows shows SNR vs. length for
    each filter, but with the power backoff value set as appropriate for
    each length.


Glenn Golden
Principal Engineer
Teranetics, Inc.
ggolden@teranetics.com


plot.gif