Re: LAN/WAN




Haim,

The reality is that GbE is today an optical networking protocol
standard.  Whether you are using in a LAN or a MAN or a WAN is
irrevalent.  Several people are using it for WAN applications.  Bill
wrote about someone from UUNet installing a link between Canada and the
US using GbE.  The only problem is that GbE does not provide any
operations support over the WAN link.

10GbE will most definately be an optical networking protocol.  There is
a lot of working going on in other standards groups that are looking a
the support issues of optical networking.  This needs to be addressed
before you dismiss the WAN implications of 10GbE by making a restriction
of using it only within LAN systems.

The reason that telcos have historically provided only connection based
sevices is because of the TDM nature of voice services.  One of the
distiction between LAN and WAN systems today is that LAN systems, 802.3
in particular, are based on modulo 10 data rates, while WAN systems, in
the US are based on modulo 64k.  Europe has a different WAN data rate
standard.

Optical networking provides directly connected, customer premise
equpment (CPE) to CPE services without the telco data rate restriction.
It is this type of WAN environment that 10GbE will play in. 
Transparent  LAN data services that will replace the ATM and Frame Relay
systems that are in place today are some of the changes that might take
place.  

Please do not restrict the distances that 10GbE will be used over. 
Please allow for changes in the way that WAN systems are being
implemented and supported.

					Thank you,
					Roy Bynum


Haim Shafir wrote:
> 
> I agree completely with Bill,
> the distinction between LAN and WAN
> is artificial , there is no technical barrier
> to provide city wide "LAN". More and more fiber
> is available and bandwidth is a commodity.
> ( look at news of Enron's new market, symbol ENE ).
> 
> The distinction is true today.
> mostly because the telecos developed a connection based
> synchronous network. It all change if you use
> a connection-less packet based "Ethernet" like network.
> 
> Selection of Jitter ad BER performance implies a decision
> on distance, 10GBE could be the standard for
> metropolitan Wide networks, you do not need
> the complexity of Sonet for a packet switched, asynchronous,
> network.
> 
> So we can start from the Sonet spec and scale it
> down but still be able to send data across a city
> or we can use the Fibre Channel spec and limit the scope of
> a 10BGE network to a building.
> 
> >From the PHY point of view, the selection of the PHY/ASIC interface
> ( single ended or diff ) have an impact on jitter performance
> to get good jitter performance ( closer to Sonet spec )
> one needs a diff interface.
> 
> >
> 
> At 08:51 AM 5/28/99 -0400, Bill St. Arnaud wrote:
> >
> >All:
> >I have been following the interesting debate about BER. Let me bring some
> >further issues into the debate.
> >
> >I am assuming that on WAN and long haul GbE the upper layer protocol will
> >only be IP.
> >
> >On most IP links, even ones with BERs of 10^-15 there is about 1-3% packet
> >loss and retransmission.  This is due to a number of factors but most
> >typically it relates to TCP flow control mechanism from server bound
> >congestion (not network congestion) and the use of WRED in routers.
> >
> >So, on most IP links the packet loss due to BER is significantly less than
> >that due to normal TCP congestion.  As long as that ratio is maintained it
> >is largely irrelevant what the absolute BER value is.  There will be many
> >more retransmissions from the IP layer than there will be at the physical
> >layer due to BER.
> >
> >Other protocols like Frame Relay and SNA are a lot more sensitive to high
> >BERs.  IP ( in particular TCP/IP) is significantly more robust and can work
> >quite effectively in high BER environments e.g. TCP/IP over barbed wire.
> >
> >I would like to suggest that the 802.3 HSSG group consider an 2 solutions
> >for 10xGbE WAN:
> >(1) native 10xGbE using 8b/10b; and
> >(2)10xGbE mapped to a SONET STS OC-192 frame
> >
> >For extreme long haul solutions SONET makes a lot of sense as a transport
> >technology.  However for intermediate long haul (up to 1000 km) and WAN
> >native 10xGbE is more attractive. Native GbE can be either transported on a
> >transparent optical network or carried directly on a CWDM system with
> >transceivers. In medium range networks coding efficiency is not as important
> >as it is in long haul networks. If coding efficiency is important then in my
> >opinion, it does not make sense to invent a new coding scheme for 10xGbE
> >when it would be just as easy to map it to a SONET frame.
> >
> >The attraction of native 10xGbE for the WAN is that it is a "wide area
> >networking solution for the rest of us".  You don't need to hire specialized
> >SONET engineers to run and manage your networks.  The 18 year old kid who is
> >running your LAN can now easily learn to operate and manage a WAN.
> >
> >In Canada and the US, there are several vendors who are willing to sell dark
> >fiber at a very reasonable cost.  Right now the cost of building a WAN with
> >10xGbE and CWDM is substantially less (for comparable data rates) than using
> >SONET equipment.
> >
> >Bill
> >
> >
> >
> >
> >
> >-------------------------------------------
> >Bill St Arnaud
> >Director Network Projects
> >CANARIE
> >bill.st.arnaud@xxxxxxxxxx
> >http://tweetie.canarie.ca/~bstarn
> >
> >
> >
> >
> >
> >
> >
> >> -----Original Message-----
> >> From: owner-stds-802-3-hssg@xxxxxxxxxxxxxxxxxx
> >> [mailto:owner-stds-802-3-hssg@xxxxxxxxxxxxxxxxxx]On Behalf Of
> >> bin.guo@xxxxxxx
> >> Sent: Thursday, May 27, 1999 7:28 PM
> >> To: rtaborek@xxxxxxxxxxxxxxxx; dwmartin@xxxxxxxxxxxxxxxxxx
> >> Cc: stds-802-3-hssg@xxxxxxxx; sachs@xxxxxxxxxxxxxx; "widmer@xxxxxxxxxx
> >> widmer@xxxxxxxxxx widmer"@us.ibm.com
> >> Subject: RE: 1000BASE-T PCS question
> >>
> >>
> >>
> >> Rich,
> >>
> >> The DC balance can be directly translated into jitter (when timing is
> >> concerned) and offset (when threshold slicing is concerned).  You
> >> only need
> >> to deal with the former if the signal is 2-level NRZI, while you need to
> >> deal with both if multi-level signal modulation is used.
> >>
> >> For long term DC imbalance, it translates into low frequency jitter and if
> >> it's low enough(<1 KHz ?), it's called baseline wonder.  For
> >> short term, it
> >> relates to Data Dependent Jitter, which is more difficult for timing
> >> recovery to handle since it's not from system or channel imparity, and
> >> therefore it's harder to compensate.
> >>
> >> When you have a lot of jitter margin, for example in lower speed clocking,
> >> the amount of jitter, translated from DC drift resulted from data
> >> imbalance
> >> coupled by AC circuit, percentage wise is a small portion of the clock
> >> period and therefore does not contribute to much of the eye
> >> closing.  On the
> >> other hand, for high speed clocking at 10G (100 ps?), the jitter
> >> translated
> >> from the same amount of DC drift can be a significant portion of the clock
> >> period, so contributes to much large percentage wise jitter which
> >> results in
> >> reduced eye opening -- higher BER.
> >>
> >> Dave said in his mail that "The limiting factor is enough RX optical power
> >> to provide a sufficiently open eye." but you still have to deal with the
> >> data dependent jitter due to DC imbalance generated after O/E, that can
> >> close the eye further again.
> >>
> >> Bin
> >>
> >> ADL, AMD
> >>
> >> > -----Original Message-----
> >> > From:      Rich Taborek [SMTP:rtaborek@xxxxxxxxxxxxxxxx]
> >> > Sent:      Thursday, May 27, 1999 3:23 PM
> >> > To:        David Martin
> >> > Cc:        HSSG_reflector; Sachs,Marty; Widmer,Albert_X
> >> > Subject:   Re: 1000BASE-T PCS question
> >> >
> >> >
> >> > Dave,
> >> >
> >> > Do you know of any research or other proofs in this area? You say that
> >> > lower speed SONET links regularly achieves BERs of < 10 E-15. I have
> >> > substantial experience with mainframe serial links such as ESCON(tm)
> >> > where the effective system BERs are in the same ballpark. SONET uses
> >> > scrambling with long term DC balance and ESCON uses 8B/10B with short
> >> > term DC balance. The following questions come to mind:
> >> >
> >> > - How important is DC balance?
> >> > - How does this importance scale in going to 10 Gbps?
> >> >
> >> > I'll see if I can get some 8B/10B experts to chime in here if you can
> >> > get scrambling experts to bear down on the same problem.
> >> >
> >> > --
> >> >
> >> > >(text deleted)
> >> > >
> >> > >The point here is that the SONET scrambler is not the limiting issue in
> >> > >achieving low error rates. The issue is having enough photons/bit, or
> >> > >optical SNR (eye-Q) to accurately recover the data.
> >> > >
> >> > >...Dave
> >> > >
> >> > >David W. Martin
> >> > >Nortel Networks
> >> > >+1 613 765-2901
> >> > >+1 613 763-2388 (fax)
> >> > >dwmartin@xxxxxxxxxxxxxxxxxx
> >> > >========================
> >>
> >
> 
> Haim Shafir
> e9 Inc.
> PH 408-343-0192 cell 408-892-1838 fax 408-873-2642
> hshafir@xxxxxxx