PCBs drive the network
Ron,
If I understand correctly, we are designing a network
standard based on the capabilities of FR-4 to support
the backplane. This may be a relevant approach. You
are the first person with the courage to admit it.
However, we have to be careful with this design approach.
We might wind up with a very nice backplane extender.
Pat Gilliland
patgil@xxxxxxxxxxx
----------------------------------------------------------
Edward
I agree with Joel on this. I am presently designing 2 GBS traces on FR4
and see no
problem with 3.125 GBS or there-abouts.
As Joel has indicated one must pay careful attention to the geometrys,
further one
must use good connectors that stay at 50 ohms up to several Ghz.
Of special intrest:
1. relieve ground/power planes under all component pads to the height
required for the pad to look like a 50 ohm line.
2. relieve the ground/power planes far enough out to eliminate fringing
capacitance to a unimportant consideration, or relieve the
ground/power
planes all the way through and depend on the fringing capacitance.
It may
be necessary to use a field solver to simulate it or to make a
model and
measure impedances.
3. relieve via ground/power layers far enough away to keep them from
being less than 50 ohms.
4. pay careful attention to via stubs. Blind vias and the like may be
required.
5. pay careful attention to power line bypassing, simulate on-chip
capacitance,
package capacitance, PCB capacitance and discrete bypass capacitors.
Do these all well and you should be ok. Note that the Hari interface was
designed
to meet the need to provide a geometry that works using FR4 to 10 GBS with
real-world PCB traces. The frequency dependent loss and reflections at 10 GBS
raw would be nearly impossible to compensate. At 3.125 GBS we still have a
workable solution.
Ron Miller
Joel Goergen wrote:
> I am not sure Ed got the right name in here, because I don't agree with
most of
> it. :)
>
> > However, it violates a lot of high-frequency circuit design rules; as a
> > result, it may make HARI a unreliable block in a system.
>
> I don't see it violating any rules.
>
> > Furthermore, additional circuit, HARI, is working against our successful,
> > Ethernet practice of keeping it simple, and low-cost -- unless we prove
HARI
> > is a "MUST" for 10GbE product, it should be an optional block.
> >
> > For an extremely high frequency PC layout, the path-length should be
kept as
> > short as possible. The PCB characteristic impedance has about +/- 20%
> > tolerance which will cause waveform distortion being severe enough at 2.5
> > Gbps data rate to cause excessive errors. Even the skew is minimized by
> > deskew circuit, the waveform distortion by reflection will cause excessive
> > JITTER by altering the bit-timing information of each bit (bit-cell timing
> > near 300 ps), which provides the deskew circuit a wrong data. This is one
> > of the reasons that high frequency transceiver and PLL are preferred to be
> > in one chip.
>
> I really think what this boils down to if you agree with the above
statement is
> that you don't have a current understanding of circuit board geometry,
how it is
> developed, and what kind of control can be used to over come these issues in
> 'the circuit board of today'. From my point of view, I can remove all the
issues
> in this email through careful understanding of the pcb construction. ie,
Ed's
> points are mostly true if you through the gerber over the wall and take
what the
> board shop sends back.
>
> > Over 2.5 Gbps, and at 20" PC run length, the signal amplitude will be
> > drastically reduced for each inch the signal travels to cause the
> > destination data without sufficient Signal-to-Noise ratio -- inviting for
> > excessive errors. In addition, the rise time will be drastically
increased
> > to add further jitter to cause wrong data into deskew circuit.
> >
> > The higher the data rate, the capacitive and inductive coupling noise are
> > higher which are linearly proportional to data rate, and the parallel
> > length (20" parallel is excessive at 2.5 Gbps). A ground plan between two
> > adjacent signals may reduce crosswalk but not necessarily eliminate it
-- no
> > absolute assurance of eliminating the crosswalk effect. Furthermore, the
> > radiation issues will much tougher to resolve.
> >
> > The PC runs through the backplane have to go through connectors to create
> > waveform distortion caused by impedance mis-match of connectors. At
300 pc
> > cell time, any glitch could be the sauce of errors.
> >
> > Unfortunately, circuit problems are very difficult to debug, which show up
> > as excessive random errors. Some time, it takes over six months to find
> > it, then there is no simple cure.
>
> Not sure about this .... all of the issues I have seen in high speed
> differential resulting in the failures listed above have been the result
of poor
> power design at the source and destination. The only high frequency
desing rules
> I have followed are: modeling, good power design, test cards, good power
design,
> trace and via geometry testing/verification, and good power design.
>
> > I further agree with Joel, that HARI will unnecessarily use up the most
> > valuable area of a PC board; namely, high frequency area. I also agree
that
> > HARI will add more power consumption to what we are struggling to reduce.
> > All of these are counter productive, unless HAIR is "MUST" for the
product.
> > Perhaps, HARI can be an option feature.
>
> Not sure I agree with this, either. I don't see the power consumption
being an
> issue because I don't know what it is yet, but I have not seen what the SiGe
> technology is going to consume, either. As far as the 'high frequency
area', I
> stand by this statement -> The lower the speed between connection points,
the
> less board fabrication design I have to develop. So, I would rather deal
with a
> few more longer pairs of 3.125 then one long run of 10 because the board
fab is
> much easier to implement. The cost for me will be the same, either way,
but one
> is a lot less work.
>
> > The system architecture are flexible. There are so many ways to
achieve the
> > same result. I am not sure that to integrate all channels which are
> > inherently distributed in one big chip is the most cost-effective way
to do
> > it, considering all the potential problems. I would think a modular
> > approach with scalability may prove to be more cost-effective and more
> > flexible to use from architecture point of view.
> >
> > I would hope some one will present test data to assure the performance,
> > before we have to vote with some reservations.
> >
> > Regards,
> >
> > Ed Chang
> > NetWorth Technologies, Inc.
> > EChang@xxxxxxxxxxxxxxxx
> >
> > -----Original Message-----
> > From: owner-stds-802-3-hssg@xxxxxxxx
> > [mailto:owner-stds-802-3-hssg@xxxxxxxx]On Behalf Of Joel Goergen
> > Sent: Tuesday, November 23, 1999 8:59 AM
> > To: HSSG
> > Subject: HARI Systems Design
> >
> > Hello all and Happy Holidays.
> >
> > I am very perplexed about a few issues that really bother me. First,
> > and for most, the comment: "Don't you think that this is either a
> > little early, or does someone have a hidden agenda?" from Roy's email
> > this morning in one of the many HARI threads. Unless I am mistaken, I
> > have not viewed this, nor any proposal by anyone as a hidden agenda. If
> > you did call HARI a hidden agenda, then you could call two phys a hidden
> > agenda, SONET a hidden agenda, etc, etc. Correct me if I am wrong,
> > people, but I thought all the presentations were from people who believe
> > they have a good idea to offer to the standard, might benifit them a
> > little, but still a good presentation - or have I just stayed on the
> > farm a little too long?
> >
> > In terms of systems design, "As for real estate on the PC board.
> > Vendors need to think about reducing the size
> > of their boards and systems. More and more floor space is being taken
> > by these systems as well as power and cooling. Reducing the size of the
> > boards, reducing the amount of electronics, reducing power requirements,
> > and increasing the density of the connections is becoming an issue in
> > large installations, like those that will use P802.3ae. Hari tends to
> > take exactly the opposite direction in system design. Hari makes it
> > easy for the system designer to become sloppy, not requiring them to
> > become tighter and better." I think I would like to take this line by
> > line.
> >
> > Vendors need to think about reducing the size of their boards and
> > systems : Well, how about customers should require less features. Then
> > I wouldn't have to go to extraordinary means to get all the components
> > shoved into a small bucket. If you want less power, less space, less
> > connections, then drop some features.
> >
> > Board Size: We fit more onto boards today on a gate per sq in level
> > then we ever have at a lower price. We are beginning to abandon fr-4
> > for newer materials at less cost per route length and more routing
> > density.
> >
> > Thermal and power: Reducing voltages to 2.5v and 3.3v have helped.
> > Power bricks are getting much more efficient. Using CMOS over GaAs and
> > Bipolar have helped. We are all required to meet Telcordia
> > requirements, so there is only so much heat per sq foot we are allowed
> > to produce. Space and thermal and weight ARE already a standard.
> >
> > Hari makes it easy for the system designer to become sloppy, not
> > requiring them to become tighter and better: Wow! Hari or something
> > similar does no such thing. It allows the designer the ability to
> > re-partition the problem. But, on the other hand, maybe I should be
> > against Hari because then that would force most people to think about
> > 10gig serial streams for long distances on copper traces ( which most
> > companies can not aford to develop ) and go with very wide 622mhz data
> > paths so my boards get thicker and more expensive - this allows the
> > designer the greater headache of routing and board fab issues. I don't
> > know, if sloppy were true, all of us would be out of business. I have
> > seen most of the systems available today and we all pretty much design
> > the same, have the same issues, and make the same trade-offs to supply
> > the customer all the features they require to make the sale.
> >
> > So, in summary, Hari is a starting place, as I have mentioned before.
> > Even the GMII and MII, etc have issues. But we have a proposal(s) of a
> > start .... how about we try to constructively look at what hari solves
> > or doesn't solve. So how do we design Hari to be 'phy independent'?
> > Because at the moment, Hari solves most of my SI issues. Oh yeah, the
> > job description for the SI guy is as follows : Comes up with last minute
> > desperate solutions to impossible problems caused by the System
> > Architect.
> >
> > Joel
>
> --
> Joel Goergen
> Lucent Technologies
> High Performance Networking Division
> 10250 Valley View, Suite 113
> Eden Prairie, MN, 55344
>
> Email: goergen@xxxxxxxxxx http://www.lucent.com
> Phone: (612) 943-8990 Cell: (612) 670-5930
> Direct: (612) 996-6932 Pager: (800) 200-0586
> Fax: (612) 996-6695