Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

RE: PMD discussion




Ed:

As far as I am concerned comparing 850 nm WDM with 1310 nm WDM is like 
comparing apples and oranges because they no not address the same customer 
segment.

My customers want to run 10 GbE in the following spaces:

1) Very, very short reach for connections between switches in the same 
room. For this application,parallel solutions seem to work fine

2) Building backbone on installed 62.5 micron MM fiber. For this 
application, only one proposal works: 1310 nm WDM
There is no threshold of pain in regard to cost, since if I cannot sell to 
my installed base THIS BUSINESS IS DEAD ON ARRIVAL.

The 850 nm WDM PMD could cost 1/10 that of the 1310 nm part but that does 
me no good because the market is much smaller.

Even if there were a substantial cost difference, because I expect cost to 
be a function of the experience curve, and the costs of the 1300 nm WDM to 
come down as volume ramps.

And volume should ramp more quickly for a part that supports  the installed 
base of 62..5 MM fiber.  Remember, customers resist FORKLIFT UPGRADES.  If 
you examine all the demonstrations to date of 10 gbE technology at trade 
shows, they are all demonstrations of upgrades to technology and products 
customers already have installed.  This is no accident. We must support the 
installed base to have this market take off quickly.

And by the way, if I am going to recommend new fiber for future proofing, I 
might as well recommend SM fiber.

3) Medium long reach ( 10 to 40 km). Several PMDs cover portions of this 
spectrum. 1300 nm serial seems most optimal.

4) Very long reach (over 50 km).  1550 nm serial seems the most optimal.

Thanks for listening

Bruce

Bruce Tolley
Enterprise Line of Business
Cisco Systems

At 03:25 PM 5/30/00 -0400, Cornejo, Edward (Edward) wrote:

>Jack, et al,
>
>I could almost live with the list you have below, however, I thought Mr.
>Tolley mentioned the importance of the embedded base(62.5um) up to 300m. If
>this is the case, I would change the WDM from the 850 to 1310 window. The
>only issue is cost between the two WDM solutions and I am sure there is a
>difference, but by how much?
>
>Also, systems folks need to tell us what their threshold of pain is for
>delta differences in cost. Is it 10%, 15%, 20% or 25%(0% is not an option,
>sorry). This could make our decision easier.
>
>Regards,
>Ed
>
>
>
> > ----------
> > From:         Jack Jewell[SMTP:jljewell@xxxxxxxxxxxxx]
> > Sent:         Tuesday, May 30, 2000 2:59 PM
> > To:   '802.3ae'
> > Subject:      RE: PMD discussion
> >
> >
> > Walt (and others who have responded in the interim),
> >
> > Although I am encouraged that the group will come to some agreement
> > without
> > delaying our schedule, there is still some way to go.  Given the breadth
> > of
> > the 5 objectives set forth, it seems almost certain that a 3-PMD set will
> > leave at least one objective being greatly under-optimized.  I would hate
> > for that to be the highest volume product.  Following the theme of
> > optimizing for each space presented Thursday by Steve Haddock (and
> > departing
> > from his presentation of only 3 spaces), I would see the following as the
> > optimal solutions for each Objective.  Given the concensus that the 2km
> > and
> > 10km objectives are best served by a common PMD, we are really discussing
> > 4
> > distinct Objectives.  Most of the debate is focused on the
> > shorter-distance
> > objectives, so this note focuses on them.  I recommend the 4-PMD set
> > below.
> >
> > SMF up to 40km - 1550nm Serial
> >
> > SMF up to 10km (incl 2km) - 1310nm Serial
> >
> > MMF up to 300m - 850nm Serial
> >
> > Installed MMF up to 100m - 850 CWDM
> >
> > Highest Volume Product Space
> > The highest-volume product space here is almost certainly the MMF up to
> > 300m.  This is due to most of the transceivers being put into new products
> > with new fibers.  An interesting comment was made last Thursday regarding
> > 100Mb Ethernet in which 3 PMDs were spec'd in order to accommodate TX
> > grade
> > cable as well as the installed base of T2 and T4 cable.  Subsequently the
> > T2
> > and T4 were more or less abandoned and virtually the entire market went
> > for
> > the TX-based PMD.  [I did not participate in that process; this is my
> > interpretation of the comments made last Thursday.  If this is inaccurate,
> > I
> > apologize.]
> >
> > Cost "Survey"
> > There have been several comments today regarding costs of different PMDs.
> > The cost comparisons which I (and Paul K) presented were NOT the result of
> > an "unscientific survey."  They are the average of estimates which were
> > circulated on the reflector.  No one was excluded from presenting their
> > own
> > numbers.  I believe a great deal of thought was put into each estimate.
> > Are
> > the numbers accurate? Of course not.  Are they all consistent enough to
> > represent the general picture (which is how they were presented)?
> > Absolutely.  They have been presented publicly and privately with no
> > voiced
> > disagreement.
> >
> > Relative Costs of Serial and WDM
> > It has been suggested and sometimes even stated outright that a WDM
> > solution
> > will be as low-cost or even lower-cost than a serial solution.  This is
> > unsupportable.  I put this question to (and look for responses from)
> > vendors
> > who have manufactured and sold transceivers in any reasonable volume.
> > (These are the ones who know transceiver costs better than anyone.)  Does
> > your optical subassembly cost more than your ICs?  In expectation of a
> > unanimous "Yes" to that question, comes the next question.  In order to
> > move
> > to higher performance levels while minimizing the cost increase should
> > you:
> > 1) increase the complexity of your optics; or 2) increase the complexity
> > of
> > your ICs?  This is why we aren't seriously discussing a WDM-only set of
> > PMDs.  WDM is a good way to get more data over a fiber than otherwise
> > possible - but it's used only when simpler approaches cannot be used.  As
> > for the ICs, there were a lot of IC vendors at the meeting having
> > aggressive
> > goals and impressive capabilities.  Assuming a "market entry" for 10GbE
> > products at the end of this year, it is reasonable to forecast that the
> > cost
> > to produce a serial product will be less than its equivalent WDM product
> > at
> > the time of market entry or within 6 months after that.  I.e. for
> > essentially the entire product lifetime.
> >
> > The 4 PMDs recommended above are not biased in order to favor my company's
> > choice of PMDs; rather my company's choice of PMDs is based on a hard view
> > of the markets and technologies required to address them in an economical
> > fashion.
> >
> > Jack
> >
> >
> >
> > -----Original Message-----
> > From: Walter Thirion [mailto:wthirion@xxxxxxxxxxxx]
> > Sent: Sunday, May 28, 2000 11:58 AM
> > To: '802.3ae'
> > Subject: PMD discussion
> >
> >
> >
> > First of all, thanks to everybody that presented PMD proposals at the last
> > meeting. I've sent my presentation to David Law, so it should be available
> > on the web site in the next couple of days.
> >
> > In listening to the discussion after my presentation and then going around
> > and talking to people, it feels to me like we're starting to converge. Not
> > there, yet, but making progress.
> >
> > The equipment manufacturers made it pretty clear they would like to see no
> > more than 3 PMDs in the standard. The PMD vendors have some concern that
> > using only 3 PMDs may sub-optimize certain objectives, however, they could
> > support the 3 PMD position if it is made clear which 3 PMDs the equipment
> > oems want.
> >
> > Based on an informal straw poll and anecdotal evidence, my opinion is the
> > first choice would be the set:
> > ________________
> > 850 nm WWDM
> > 1310 nm WWDM
> > 1550 nm Serial
> > ________________
> >
> > If that set isn't feasible, then the 2nd most popular choice is:
> > ________________
> > 850 nm WWDM
> > 1310 nm Serial
> > 1550 nm Serial
> > ________________
> >
> > Thoughts, feedback?
> >
> > Walt
> > ___________________
> > Walter Thirion
> > Chair, IEEE 802.3ae PMD Sub-Task Force
> > 301 Congress Ave.
> > Suite 2050
> > Austin, Texas 78701
> > Voice:        512-236-6951
> > Fax:  512-236-6959
> > wthirion@xxxxxxxxxxxx
> > ___________________
> >