Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: Clause 48 Comments




Boaz,

I realize that a response to this note is long overdue, but I'm finally
getting back to it. Here are my responses to your clause 48 comments.

Boaz Shahar wrote:
> 
> Section 48.2.4.3 P.135
> f) I think it Should be: ...The error code group is converted to XGMII Error
> control character

Done. 

> Figure 48-5
> Is not coordinated with the machine in Fig. 48-7
> In Fig. 48-5, if Cose_sel=1 its either /A/ or /R/.
> In the machine in Fig. 48-7, if A_CNT_0, then its /A/, regardless of the
> value of Code_Sel (I think that the description in the machine is the
> accurate one)
> I assume you ment that /K/ is transmitted when code-sel=0. This also should
> be fixed.

Done.
 
> Figure 48-7 (PCS Transmit state diagram):
> I think that there should be no dependency in A_CNT_0 for the first IPG
> column. If code_sel=0 Tx /K/, if code-sel=1 transmit /A/
> Fix the values of code-sel in th exits from SEND_RANDOM_R and SEND_RANDOM_K
> states

Done.
 
> Boaz

-- 

Best Regards,
Rich
                                      
------------------------------------------------------- 
Richard Taborek Sr.                 Phone: 408-845-6102       
Chief Technology Officer             Cell: 408-832-3957
nSerial Corporation                   Fax: 408-845-6114
2500-5 Augustine Dr.        mailto:rtaborek@xxxxxxxxxxx
Santa Clara, CA 95054            http://www.nSerial.com