Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

RE: XGMII New Electrical Characteristics




James,

HSTL Class I was adopted.  The clause will refer to EIA/JESD8-6.  Class I
provides for optional 50 ohm termination to 0.75V.  It is not believed that
the termination will be needed for XGMII applications.

Ted


> -----Original Message-----
> From:	James Colin [SMTP:james_colin_j@xxxxxxxxx]
> Sent:	Monday, November 13, 2000 5:05 AM
> To:	stds-802-3-hssg@xxxxxxxx
> Cc:	James_Colin_J@xxxxxxxxx
> Subject:	XGMII New Electrical Characteristics
> 
> 
> Hello There,
> Can someone update me in regards to XGMII electrical
> characteristics? Did it went back to SSTL_2 levels or
> HSTL 1.5v or anything else?
> 
> Thanks,
> James
> 
> 
> __________________________________________________
> Do You Yahoo!?
> Yahoo! Calendar - Get organized for the holidays!
> http://calendar.yahoo.com/