Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Re: PCS Management Counters





Vivek,

Since, according to the state machine conventions and figure 49-14,
the state is actually re-entered on every clock edge, the counter
would be incremented twice (in your case) or once for every clock
cycle spent in that state (in general).

Ben

> Vivek Mishra wrote:
> 
> Hi all,
> 
> Just a small clarification.....
> 
> The counter "ERRORED FRAME COUNTER" in PCS management counters is
> said to be incrementing when the "RX_E" state is entered.
> 
> Lets say that the state machine is in "RX_E" state for two clocks.
> 
> Will the counter increment by two or will it increment
> by one since the state was entered only once?
> 
> Regards,
> Vivek


-- 
-----------------------------------------
Benjamin Brown
AMCC
2 Commerce Park West
Suite 104 
Bedford NH 03110
603-641-9837 - Work
603-491-0296 - Cell
603-626-7455 - Fax
603-798-4115 - Home Office
bbrown@xxxxxxxx
-----------------------------------------