Re: PCS Management Counters
Vivek,
Since, according to the state machine conventions and figure 49-14,
the state is actually re-entered on every clock edge, the counter
would be incremented twice (in your case) or once for every clock
cycle spent in that state (in general).
Ben
> Vivek Mishra wrote:
>
> Hi all,
>
> Just a small clarification.....
>
> The counter "ERRORED FRAME COUNTER" in PCS management counters is
> said to be incrementing when the "RX_E" state is entered.
>
> Lets say that the state machine is in "RX_E" state for two clocks.
>
> Will the counter increment by two or will it increment
> by one since the state was entered only once?
>
> Regards,
> Vivek
--
-----------------------------------------
Benjamin Brown
AMCC
2 Commerce Park West
Suite 104
Bedford NH 03110
603-641-9837 - Work
603-491-0296 - Cell
603-626-7455 - Fax
603-798-4115 - Home Office
bbrown@xxxxxxxx
-----------------------------------------