Clause 49, Figure 49-7 - //T// followed by //O//
Hi,
Figure 49-7 does not include input data frames, containing XGXS's T column
(T0, T1, T2, or T3) followed by an O column (O4), are valid frames. From
what I've gathered from the D2.1, I just don't see how occurrences of the
above frames at the PCS input are not considered as normal.
Thanks,
Tuan Hoang
****************************************
Tuan Hoang
Optical Transport Unit
49 Discovery
Irvine, CA 92618
Phone: (949) 585-6888