Thread Links Date Links
Thread Prev Thread Next Thread Index Date Prev Date Next Date Index

Assymmetry of setup and hold times



Hi, Justin,

 

It appears that Clause 51 D2.1 specifies assymmetrical setup/hold times for the PMA
input timing (see Table 51.4) vs the PMA client input timing (see Table 51.8). For one

case it is 250 ps, while in the other case it is 300 ps.  Is there some reason behind this?

This seems to depart from the OIF SFI-4 spec. (Apologies in advance in case I have

inadvertently raked up any heated discussions.)

 

Best regards,

 

- Tom Alexander

PMC-Sierra, Inc.