RE: [802.3ae] Oc-192 rate control




Ben:

I also hope it is validated as part of technical feasibility proofs, but
this is insignificant compared to the technical feasibility challenges for
our PMDs.  I am not worried about the ability to implement the rate
adaptation algorithm or that it will interoperate with another
implementation.  The rate adaptation was never on my list of technical
feasibility concerns.  I'm comfortable with the technical feasibility and
and plans to demonstrate interoperability of XAUI, but am aware of no
similar efforts for the MDI specifications of our PMDs.  That's why I will
be flipping my vote from Approve to Disapprove on this recirculation ballot.

--Bob Grow


-----Original Message-----
From: Ben Brown [mailto:bbrown@xxxxxxxx]
Sent: Friday, June 29, 2001 10:49 AM
To: Danielle Lemay
Cc: 'stds-802-3-hssg@xxxxxxxx'
Subject: Re: [802.3ae] Oc-192 rate control




Danielle,

That's what we hope implementors will do as part
of the Technical Feasibility portion of the standard
process. :)

Ben

Danielle Lemay wrote:
> 
> Hello,
> 
> Has the Oc-192 rate control algorithm (Clause 4) been validated ?
> Specifically, has it been tested on a stream of minimum size frames ?
> 
> thanks,
> Danielle
> 
> *******************************************
> Danielle Lemay
> Design Engineer, Nishan Systems
> dlemay@xxxxxxxxxxxxxxxxx
> 408-519-3985


-- 
-----------------------------------------
Benjamin Brown
AMCC
2 Commerce Park West
Suite 104 
Bedford NH 03110
603-641-9837 - Work
603-491-0296 - Cell
603-626-7455 - Fax
603-798-4115 - Home Office
bbrown@xxxxxxxx
-----------------------------------------