Re: XAUI rate on UTP CAT 5 transmission experiment.
Benny,
Just a thought. What is the EU equivalent of the FCC? What kind of
radiation might these cables generate?
I appreciate your provocative submission. Cables are of course one major
part of the equation. Connectors are also important. Have you tried this
with RJ-45 connectors? :-) What would you suggest which is a low cost
connector, in keeping with the CAT-5 thought?
Bill
At 08:40 AM 3/7/01 -0800, Christensen, Benny wrote:
>Hi XAUI specialists
>
>
>Here is an 3.125 Gb/s 2^31-1 PRBS differential transmission example on a 2
>meter 24AWG * 4 pair UTP cable used for ethernet connections.
>The specs on the cable says 100 MHz.
>
>I cut off the connectors and applied SMA connectors for a differential pair.
>THe other wires are used for GND on both ends.
>
>GIGA lite CDR GD 41644 operates error free on this differential eye. 65
>mVpp.
>
>Removing the SDH filters and using 2*250 mVpp, the differential swing will
>be 125 mVpp inner eye opening.
>
>Tomorrow, I will investigate the jitter tolerance on this system.
>
>
>
>
>
>Benny
>--------------------------------------------
> llllllll ii llllllll llllll
>ll ll ll ll
>ll llll ll ll llll llllllllll
>ll ll ll ll ll ll ll
> llllllll ll llllllll ll ll
>
>GIGA, an Intel company
>Benny Christensen, M.Sc.E.E, Ph.D.
>Mileparken 22, DK-2740 Skovlunde, Denmark
>Tel: +45 7010 1062, Fax: +45 7010 1063
>e-mail: benny.christensen@intel.com, http://www.giga.dk
>
>
>
>
>
>
>
Bill Woodruff Velio
888 Tasman Dr. 408 474-0735
Milpitas CA 95035 Mobile 408 206-0017
bill.woodruff@velio.com
www.velio.com