[802.3ae_Serial] Serial PMD call Tuesday - new test methods
There will be a PMD teleconference tomorrow at the usual time where we will
continue work on the alternative optical test methods discussed at last
week's face to face meeting.
Briefly, these are:
Replace jitter bathtub with:
Longer lower eye mask to screen for high probability events, and
Transmitter and dispersion penalty measurement using bit-error ratio
tester to screen for low probability events.
Simplify stressed receiver generation: simulate high probability vertical
and horizontal eye closure, and sinusoidal jitter, only. Suggested method
of adding a PRBS and an interfering sine wave.
I will try to get some notes to the reflector from last week's meeting
before tomorrow's, which will be at:
Usual coordinates:
4:15 pm GMT = 17:15 CET = 11:15 am EST = 8:15 am PST, Tuesday
+1(816)650-0631 Access code 39209
Piers