[802.3ae_Serial] Revised: Call for Stressed eye and TDP Data for anonymous compilation




Revisions suggested by Piers and Greg.

Timeline:

April 1st: Suggested submission date for results to Stretch
April 2 conf call: discussion of initial compilation
April 5: due date for for getting revised data to Stretch
April 8th- presentation at Vancouver meeting 

It was suggested by Raj Savara and others that Agilent Test and Measurement
collect and compile anonymously the test data collected over the next few
weeks by the Section 52 members to help prove the methodology.

I have listed a suggested list of measurements at the end of this message.

Suggestions and comments are welcome.

Please send the information to me, mailto:stretch_camnitz@agilent.com, and I
will compile the data for presentation.

Stretch

Lovell (Stretch) Camnitz

Department Scientist
Lightwave Division MS A2UA
3910 Brickway Blvd
Agilent Technologies
Santa Rosa, CA 95403

Phone (707) 636-9121
FAX   (707) 636-9117
stretch_camnitz@agilent.com 


-------------------------------------------------------------- 


*************** General Parameters ******************

Wavelength (1550, 1310, 850 nm):
Bit Rate (9.95328 Gb/s, 10.3125 Gb/s):
Scope Filter BW- Model #

measure pk-pk jitter and VECP to 1% of distribution


******************* Clean reference TX ***************

Scope shot filter on, filter off
Jitter (pk-pk) to all but 1% of histogram ps:
VECP  dB to all but 1% of histogram:
Jitter BT curve-if available
eye opening opening at 1E-12:


******************  Stressed Eye *********************


*Filter only waveform performance (no AM or SJ)*

Filter BW:
Scope shot filter on, filter off
VECP dB to all but 1% of histogram:
Jitter p-p ps:
Risetime/Falltime (20-80%) ps:
Jitter BT curve if available
eye opening at 1E-12:


*AM interferer + Filter*

Scope shot
Electrical or optical combining?:
Frequency:
Amplitude (dB) relative to OMA:
Jitter p-p ps:


*Sinusoidal Jitter + Filter*

Scope shot
Frequency:
Amplitude p-p ps:



*Total Waveform = Filter + AM + SJ *

Scope shot
VECP dB:
Jitter p-p ps:
Jitter BT curve if available
eye opening at 1E-12:





****************** Baseline TDP measurements  *****************



BER threshold (default is 1E-12):
Decision point offset (default is +- 5 ps):
Reference receiver BW if available:


*Clean Reference TX to Reference Receiver*
Sensitivity (OMA):

* Stressed Eye to Reference Receiver*
Sensitivity (OMA):


****************** TX DUT #1 measurements  *****************

Scope shot
VECP
jitter p-p ps:
Jitter BT curve if available
eye opening at 1E-12:

*TX DUT #1 to Reference Receiver*
Sensitivity (OMA)



****************** RX DUT #1 measurements  *****************

*Clean Reference TX to RX DUT #1*
Sensitivity (OMA)

*Stressed eye to RX DUT #1*
Sensitivity (OMA)

*TX DUT #1 to RX DUT #1 (if possible)*
Sensitivity (OMA)

****************** TX DUT #2 measurements  *****************

Scope shot

*TX DUT #2 to Reference Receiver*
Sensitivity (OMA)



****************** RX DUT #2 measurements  *****************

*Clean Reference TX to RX DUT #2*
Sensitivity (OMA)

*Stressed eye to RX DUT #2*
Sensitivity (OMA)

*TX DUT #2 to RX DUT #1 (if possible)*
Sensitivity (OMA)