Thread Links | Date Links | ||||
---|---|---|---|---|---|
Thread Prev | Thread Next | Thread Index | Date Prev | Date Next | Date Index |
Well said ! I can only add that I love my Mum, and apple pie is nice. J From: Brad Booth [mailto:bbooth@xxxxxxxx] Jonathan, No disagreement on doing things for the right reasons. The issue is, which reason is the right one? :-) For some applications, latency is a big issue. For others, power could be an issue. And was mentioned on Monday, the ability to not have to create an engineered link could address issues. The great thing is that the task force is considering these things and truly looking at if we can do a 3m no FEC. The task force is not ignoring the ask, and that's great because for 25G Ethernet, that server to switch link is going to be the dominant volume. I know I'm preaching to the choir when I say that getting this right will be a big win for the specification and the market. I believe that's why we're seeing the passion and dedication from our fellow colleagues to bring us data. :-) All goodness in my books. Cheers, On Wed, Jul 15, 2015 at 12:34 PM, Jonathan King <jonathan.king@xxxxxxxxxxx> wrote: Hi Brad, I understood there’s a case to be made for 3m based on latency, and enlarging the application area for the standard. Likewise, I was just addressing the power argument. Let’s do things for the right reasons. Best wishes jonathan From: Brad Booth [mailto:bbooth@xxxxxxxx] Jonathan, I was only providing clarification relative to the FEC power information. You may have missed the points my colleague made yesterday about latency and BMP being ranked higher on the list than power. FEC increases latency, and in some applications latency is a measured performance parameter. Therefore, to be competitive with a 3m solution, the end user may have to consider doing an engineered link. Once that reach becomes an engineering, it is no longer a standards-based commodity component which impacts the market size for the standard. It is beneficial to the market and to end users to maximize the volume for a standards-based solution, and that can be achieved with a little more work for a 3m no FEC solution. Cheers, On Tue, Jul 14, 2015 at 8:28 PM, Jonathan King <jonathan.king@xxxxxxxxxxx> wrote: Hi Brad, I don’t disagree with any of your points 1 to 4 and…. if you remove the FEC gain, the SNR has to be made up in other ways – FEC is an efficient way of buying SNR. Agree, using FEC means adding the power for implementing the code/decode circuitry, but it allows power reduction in other parts of the link. Net result, less power burn for ‘with FEC’ links, leaving more power for the things customers really care about etc… best wishes jonathan From: Brad Booth [mailto:bbooth@xxxxxxxx] I think there a few factors that have to be considered, but unfortunately there was so much discussion about the validity of the data, that the key points were truly missed. 1) Datacenters have a power constraint. There is not unlimited power. 2) Even if the power is 25 mW for FEC, FEC has to be used on both ends of the link; therefore, the power number is double. 3) The power supplied is about 5-6x the power used due to losses inherent in electronics, transformers, etc. 4) Power is amplified by the scale. What seems small at a single point in the architecture is amplified when you move to hyper-scale. At 1M servers, that's 50 kW for FEC which is equivalent to about 4-5 server racks. Finally, power spent on FEC (if not required) takes power away from other things that customers really care about like VMs, security, etc. Just some extra food for thought. Thanks, On Tue, Jul 14, 2015 at 4:26 PM, Scott Kipp <skipp@xxxxxxxxxxx> wrote: 802.3by, Yesterday, there was considerable debate about power consumption due to the RS-FEC used in 25GbE. In goergen_3by_02_0715.pdf, the power consumption for RS-FEC was approximated to be 300mW. I did a quick search and found these estimates: http://www.ieee802.org/3/bm/public/sep12/wang_01_0912_optx.pdf = 45mW on slide 3 http://www.ieee802.org/3/bj/public/mar12/gustlin_01_0312.pdf = 90 mW on page 6 http://www.ieee802.org/3/bs/public/adhoc/logic/oct21_14/wangz_01_1014_logic.pdf, Wangz concludes: In practice, either KR4 or KP4 FEC is easy to implement and not much power-consuming. A conservative estimate is 100mW for 100GBASE-KR4. 25GBASE-KR4 will consume 1/4 of this power or 25mW based on a one of the four lanes. I propose that 25mW is a practical power consumption for RS-FEC. Let’s calculate the cost of the power consumption for the server over a 3-year lifespan.
Another correction that I wanted to make is to the estimate is the cost of electricity. Hyperscale data centers that consume megawatts of power buy electricity at wholesale rates. Many are located near electric power plants so that Google pays about $0.04/kWh according to this article: http://www.oregonlive.com/silicon-forest/index.ssf/2013/09/google_reaches_new_data_center.html The wholesale electricity industry is regulated and current pricing is available for this site and shows electricity ranges in 2015 has varied from $0.036/MWh to $0.065/MWh. Read more here: http://www.eia.gov/electricity/wholesale/ I used a conservative $0.05/kWh. My estimate is that the cost of RS-FEC per server is about $0.03 over the life of the server. Three cents is basically in the noise for our purposes and should not be a fundamental driver for 3m cabling without FEC. Kind regards, Scott Kipp |