Re: [802.3_400G] Breakout Functionality Objective



Paul,

As demonstrated in the CFI 40G servers are already being deployed.  This will grow.

 

One thing I would note though is something that Brad brought up earlier, which I support. The aggregate of higher density support for 40G does not mean that the aggregate itself would necessarily have to add up to 400G.  Think 8x50 for example.  We could run that at 8 ports of 40G, the aggregate is not 400G, but the breakout function has been supported.

 

John

 

From: Kolesar, Paul [mailto:PKOLESAR@xxxxxxxxxxxxx]
Sent: Wednesday, October 16, 2013 3:17 PM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: Re: [802.3_400G] Breakout Functionality Objective

 

I am in favor of an objective for break-out functionality. That said, the challenge of breaking out 40G interfaces from a system based on 25G electrical lanes does not appear trivial.  Fortunately this is not the case for 100G break-outs.  While the proposed objective language does not mandate 40G break-out, I am concerned that stating it as a possibility could become a distraction, consuming time and resources.  Can someone state a case that supports keeping 40G in the proposed objective?

 

Regards,

Paul

 

From: John D'Ambrosia [mailto:John_DAmbrosia@xxxxxxxx]
Sent: Wednesday, October 16, 2013 11:23 AM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: Re: [802.3_400G] Breakout Functinoality Objective

 

Chris,

There are a number of ways to enable breakout, which could be via the architecture itself.  Also, note that there is no timing related to this.  It might apply to a future PMD.  And as Mike noted in his response, there is nothing in here that says all PMD variants have to support break out.

 

John

 

From: Chris Cole [mailto:chris.cole@xxxxxxxxxxx]
Sent: Wednesday, October 16, 2013 11:06 AM
To: DAmbrosia, John; STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: RE: [802.3_400G] Breakout Functinoality Objective

 

John,

 

Does this objective preclude a duplex SMF (pair) PMD, for example 8x50G or 4x100G WDM?

 

Chris

 

From: John D'Ambrosia [mailto:John_DAmbrosia@xxxxxxxx]
Sent: Wednesday, October 16, 2013 6:15 AM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: [802.3_400G] Breakout Functinoality Objective

 

All,

Per our call last week, what are the thoughts on the wording of this as a proposed objective –

 

Provide appropriate support for breakout functionality to 40G and / or 100G

 

There was some concern about potential impact or unintended consequences that people wanted to see this wording to discuss further.

 

Regards,

 

John