Paul 

I said by "the time server and silicon technology catches where 400 GbE is integrated on the TOR”!  In 1-2 silicon generation when 400 GbE is integrated on the TOR then you will also see 50 GbE on the server.

We are developing 25GbE because 10G is not sufficient for a segment of market and 25 GbE cost less than the alternative the 40 GbE.  The same economic will apply to 50 GbE later on!

Thanks,
Ali Ghiasi
Ghiasi Quantum LLC



On Jun 24, 2015, at 12:31 PM, Kolesar, Paul <PKOLESAR@xxxxxxxxxxxxx> wrote:

Ali,
In order for 50G lanes to make sense for ToR switches, servers must be able to use that rate.  I think the market will put 25G servers to several years of use before 50G servers overtake them.  Witness the time lag for 10G servers to overtake sub-10G servers.  10G is now in its prime with 25G up and coming.  If this is not true, why are we bothering to develop 25GE?
 
Paul
 
From: Ali Ghiasi [mailto:aghiasi@xxxxxxxxx] 
Sent: Wednesday, June 24, 2015 1:59 PM
To: Kolesar, Paul
Cc: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-3-400G] one comment about 4x100G breakout RE: IEEE P802.3bs 400 Gb/s Ethernet Task Force Logic Ad Hoc
 
Paul 
 
Initial application of 400 GbE will follow 100 GbE early deployment SMF ports on Routers and Spin switches.  Du Wenhua statement is correct to say 400 GbE will not be integrated initially on TOR.  By the time server and silicon technology catches where 400 GbE will be integrated on TOR then we will have 50 GbE on single lane of SMF/MMF. 
 
So 16x25G MMF has limited life/application and soon to be obsolete with emergence of 50G eco-system.
 
Thanks,
Ali Ghiasi
Ghiasi Quantum LLC
 

<image001.png>
 
On Jun 24, 2015, at 7:25 AM, Kolesar, Paul <PKOLESAR@xxxxxxxxxxxxx> wrote:


Du Wenhua,
I thanks for your thoughts.  This is a valuable discussion.  

I do not disagree with your points on KP4 and KR4 FEC at 100G, but I have a different view on your conclusion point 3). I think 16x25G and 8x50G break-outs can play a role in ToR switch ports facing the servers.  A port that delivers 16 lanes of 25G can provide transceiver cost advantages compared to discrete transceivers. It also provides electrical signal routing advantages because all electrical lanes can be of nearly the same minimal length rather than spread out to reach ports across the entire switch faceplate which alleviates the need for repeater chips saving cost and power.

Regards,
Paul Kolesar

-----Original Message-----
From: Duwenhua [mailto:duwenhua@xxxxxxxxxxxxx] 
Sent: Wednesday, June 24, 2015 3:36 AM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-3-400G] one comment about 4x100G breakout RE: IEEE P802.3bs 400 Gb/s Ethernet Task Force Logic Ad Hoc

Hi, Martin

400GE FEC Breakout: (langhammer_02_0615_logic.pdf)  pag5 said:
1x400G KP4 ASIC: 55645
1x400G KP4 & 4x100G KR4 ASIC: 61518 
  11% area increase

My comments: 
 1) What is the size of 1x400G KP4 & 4x100G KP4 FEC? 
 2) today 100GbE choose KR4but I think that the breakout 100GbE will need KP4 FEC if the 100GbE SMF PMD choose 100G PAM4 in future.
     --In long term, serial is better than parallel. For 100GbE,  100G PAM4 SMF PMD is better than 4x25G SMF PMD.
 3) same idea can be seen at page29 of http://www.ieee802.org/3/bs/public/14_05/maki_3bs_01a_0514.pdf   QSFP28 has a DSP&FEC which convert 4x25G to 1x100G.

My conclusions:
 1) 4x100G breakout, the FEC should be able to dynamic changed: 4x100G KR4, or 4x100G KP4.
 2) 4x100G breakout is very important in data center switch at the positions of Spine switch and Core switch, because face port density and flexibility.
 3) 8x50G and 16x25G breakout is not important, because only TOR switch need 50G/25GE, but TOR switch do not have 400GE port.

                         --Du Wenhua



-----Original Message-----
From: Mark Gustlin [mailto:mark.gustlin@xxxxxxxxxx]
Sent: Saturday, June 20, 2015 8:09 AM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: Re: [STDS-802-3-400G] IEEE P802.3bs 400 Gb/s Ethernet Task 
Force Logic Ad Hoc

All,

Presentations are now up on the logic ad hoc web site from today's ad hoc call:
http://www.ieee802.org/3/bs/public/adhoc/logic/index.shtml

Thanks, Mark


-----Original Message-----
From: Mark Gustlin
Sent: Monday, June 15, 2015 10:59 AM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: RE: IEEE P802.3bs 400 Gb/s Ethernet Task Force Logic Ad Hoc

All,

Just a reminder of the upcoming logic ad hoc call.
The current agenda is:
400GE FEC Implementation - Martin Langhammer Considerations for 
breakout - Martin Langhammer 1x400G vs 4x100G FEC Implications - 
Bill Wilkie

Requests are due by end of day Wednesday. There is room for only one 
more presentation for this call, so the next request will get the last slot.
There is another opportunity on June 29th.

Thanks, Mark Gustlin


From: Mark Gustlin [mailto:mark.gustlin@xxxxxxxxxx]
Sent: Thursday, June 04, 2015 2:49 PM
To: STDS-802-3-400G@xxxxxxxxxxxxxxxxx
Subject: [STDS-802-3-400G] IEEE P802.3bs 400 Gb/s Ethernet Task 
Force Logic Ad Hoc

All,

This is an announcement of the next IEEE P802.3bs 400 Gb/s Ethernet 
Task Force Logic Ad Hoc conference call opportunity.

The next call will take place on Friday June 19th from 8am-10am PDT.

If you are interested in presenting, please request a timeslot by 
the end of Wednesday June 17th. A separate calendar invite will also follow.

In addition there will be another opportunity on Monday June 29th at
8am- 10am PDT.

Thanks, Mark Gustlin


-- Do not delete or change any of the following text. --

Join WebEx meeting
Meeting number: 492 414 237
Meeting password: four123!
Join by phone
Call-in toll-free number: 1-(877) 582-3182 (US) Call-in number:
1-(770) 657-
9791 (US) Show global numbers Conference Code: 568 245 6486