Suggested baseline for T3/T4 updated to better match T1/T2 text. Note the following changes to baseline text (i.e., presentation slides 10 and 12):
From:
(Slide 10) - "A Type 3 or Type 4 PSE, when connected to a single-signature PD, may consider the DC MPS component to be either present or absent if neither of the above conditions are met."
(Slide 12) - "A Type 3 or Type 4 PSE, when connected to a dual -signature PD, may consider the DC MPS component on a pairset to be either present or absent if neither of the above conditions are met."
To:
(Slide 10) - "A Type 3 or Type 4 PSE, when connected to a single-signature PD, may consider the DC MPS component to be either present or absent if IPort-2P of the pairset with the highest current or the sum of IPort-2P of both pairsets of the same polarity is within the range of the applicable IHold."
(Slide 12) - "A Type 3 or Type 4 PSE, when connected to a dual-signature PD, may consider the DC MPS component on a pairset to be either present or absent if IPort-2P is within the range of the applicable IHold."