Colleagues, Coming out of the March meeting (see link below to minutes), we have identified 26 AWG stranded as a "target" cable gauge to consider based on RTPGE survey responses (see link below). Please note, I expect, consistent with other copper IEEE 802.3 link segments, other cable gauge sizes (e.g., 24 AWG, 28 AWG, 30 AWG) may be used to build compliant RTPGE link segments (i.e., link segments have been specified without a requirement for cable gauge). The maximum link segment insertion losses for the 15 meter topology listed in the RTPGE objectives is characterized using 26 AWG stranded in order to address the survey response requests.
Regards, Chris DiMinico MC Communications Channel definitions Ad hoc co-chair
meeting minutes (unconfirmed) http://www.ieee802.org/3/bp/public/mar13/minutes_3bp_u_0313.pdf
The survey is targeted at
automotive OEMs and suppliers to be used Reduced Twisted Pair Gigabit Ethernet Link Segment Characteristics Reduced Twisted Pair Gigabit Ethernet PHY Study Group
Objectives