Hi Tim, I hate to be difficult, but as I noted in comment #321, subclause 30.1 'Overview' says, 'Implementation of part or all of Layer Management is not a requirement for conformance
to any other clause of this standard.'. As a result, I believe that the D-PLCA state diagram should be specified to operate in the absence of management attributes. Based on this, I'd like to suggest that following changes. Thanks, and best regards, David ----- soft_aging_cycles Defines the number of BEACON cycles before the SOFT claims over the transmit opportunities expire.
When clause 30 management is implemented, t Values:
Default: 50 hard_aging_cycles Defines the number of BEACON cycles before the HARD claims over the transmit opportunities expire.
When clause 30 management is implemented, t Values:
Default: 1000 From: Tim Baggett <000015f075877453-dmarc-request@xxxxxxxxxxxxxxxxx>
Proposed text changes: P26 L2 30.16.1.1.8 aDPLCASoftAgingCycles ATTRIBUTE APPROPRIATE SYNTAX: INTEGER BEHAVIOUR DEFINED AS: Controls the aging time in BEACON cycles of D-PLCA SOFT claims as defined by the P26 L12 30.16.1.1.9 aDPLCAHardAgingCycles ATTRIBUTE APPROPRIATE SYNTAX: INTEGER BEHAVIOUR DEFINED AS: Controls the aging time in BEACON cycles of D-PLCA HARD claims as defined by the P26 L23 30.16.1.1.10 aDPLCACoordinatorRoleAllowed ATTRIBUTE APPROPRIATE SYNTAX: BOOLEAN BEHAVIOUR DEFINED AS: Controls whether the D-PLCA enabled node is allowed to take the coordinator role, mapping to --
Tim Baggett
Technical Staff Engineer - Applications --------------------------------------------------------------------------------- Microchip Technology, Inc. Automotive Information Systems 8601 Ranch Rd 2222, Park Centre, Bldg. 3, Austin, TX 78730 Office: 512-334-8450 Tim.Baggett@xxxxxxxxxxxxx
www.microchip.com --------------------------------------------------------------------------------- To unsubscribe from the STDS-802-3-SPMD list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-SPMD&A=1 To unsubscribe from the STDS-802-3-SPMD list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-SPMD&A=1 |