| Thread Links | Date Links | ||||
|---|---|---|---|---|---|
| Thread Prev | Thread Next | Thread Index | Date Prev | Date Next | Date Index |
|
Hi Folks, Rubén, Thanks for the detailed explanation. It could be interesting to look at this from a simpler COM perspective. Hossein, perhaps there is also a statistical way to look at this. Development of PDF/CDF methods seems prudent for the negative delta COM, with the present COM_PR(1,1) result serving as the asymptotic reference point.
Regards,
Sent: Wednesday, November 11, 2026 11:21 PM To: STDS-802-3-COM@xxxxxxxxxxxxxxxxx From: Ruben Perez - Aranda (rupereza) <0000679251f2c15c-dmarc-request@xxxxxxxxxxxxxxxxx>
Hi Hossein, I would like to make some amendments to my comments to your contribution yesterday and express my concerns. MLSE does not need a monic, causal, minimum-phase target. The Viterbi algorithm needs only two things:
Let’s assume as example g(z) = a + z⁻¹ + a z⁻²
symmetric because it a case that appears in the contributions. Causality and minimum phase are requirements of the DFE, not of MLSE. A non-causal target is a delayed causal one, z⁻¹g(z)
= a + z⁻¹ + a z⁻², so the detector runs on the 3-tap target
[a 1 a]. This has memory 2 (N² states) and adds one symbol of latency. Full-state MLSE performance depends only on |G(e^{iω})|. So, all targets with the same magnitude response have the same distance spectrum, the same d²min and the same union bound. Phase does not matter (either
linear phase or minimum phase). The noise colouring after the FFE also depends only on |G|: a ZF FFE W = G/H gives a noise PSD proportional to |G|²/|H|². So, until here everything seems OK. A symmetric 3-tap target can never beat the best constrained monic 3-tap causal target, and it is usually worse. It is only lossless if |1 + 2a cos ω| happens to match the whitened folded channel magnitude. Otherwise,
the FFE output noise is coloured and the Euclidean Viterbi is no longer ML, the same issue as with any constrained target. In other words, Forney’s MLSE is based on joint ZF calculation of FFE and DFE, with FFE being the whitened matched filter of the sampled channel and DFE monic, min-phase, stable. It is white noise, i.e., Viterbi
is ML, provided target response is unconstrained (3-tap is constrained). MMSE in general will not produce white noise, but will have some residual ISI, even with unconstrained g(z). However, unbiased MMSE solution will provide similar solution of ZF at high
SNR regime, our PAM4 with KP4 RS FEC scenario and is a very good choice for jointly optimize FFE and DFE. Any of these solutions will produce a monic, min-phase stable target response, never a linear phase solution as the g(z) of the example. So, a linear
phase solution is equivalent to colored noise, where Viterbi is not ML. In addition, a practical MLSE issue is that reduced-state detectors and DFE fallback rely on the target’s energy being concentrated in the first taps. Of all targets with a given magnitude, the minimum-phase one
is the most front-loaded, so the symmetric target is the poor choice here. Therefore, my feedback is that, by considering any phase type of PR in COM model we might consider solutions as good ones that later are not realistic from MLSE implementation point of view. I support extending
the MLSE to second order, but min-phase. I suggest the target response can be calculated jointly with the FFE under the same MMSE problem, so min-phase is guaranteed, instead of being an input to the MMSE problem that only adapts the FFE taps. On top of that,
maximizing the output SNR of the joint MMSE is equivalent to maximize the effective SNR of sampled channel, therefore optimal from sampling phase point of view (if not because the constraints, it will be close). Maximization of the joint MMSE SNR also strongly
penalizes the phase-induced Nyquist null, which governs MLSE error events and DFE error propagation. I just wanted to advise on this issue so you may consider it in COM. Regards, Rubén To unsubscribe from the STDS-802-3-COM list, click the following link:
https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-COM&A=1 To unsubscribe from the STDS-802-3-COM list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-COM&A=1 |