[802.3_ISOLATION] 1.2/50 generator voltage



Thanks everyone for listening to my TC 109 presentation.

The last question we had was on the 1.2/50 generator voltage.
The practice in the ITU-T is to quote the generator capacitor charge voltage. This catches some people out as the IEC 60060-1 quotes the peak open-circuit 1.2/50 waveform voltage.
I did a run with my 1.2/50-8/20 combination wave generator simulation with the capacitor charge voltage set to 2.5 kV. The resulting peak open-circuit 1.2/50 voltage was 2.31 kV, some 4 % lower than the 2.4 kV in 802.3.
A small difference that I wouldn't lose any sleep over.