[10GBASE-CX4] comments on latest CX4 revision





54.7.3.6 Differential Output Template and Figure 54-3
The interconnect from the MDI to the scope for measuring against this 
template has not been adequately described.  I could not find any 
information on the plumbing.  A tight template like this one must be spec'd 
along with the interconnect hardware.

Please consider readily available adapters and cables for this.  I suggest 
that the test interface be comprised of a 1m, 24AWG cable to connect 
between the MDI and a GigaCN-to-SMA adapter board.  If you don't have one 
of these boards yet, you will soon!  From the SMA to the scope, we can use 
short, high quality cable.  This is easy and convenient.