(1) Input referred device noise
(2) Input referred offset
(3) Input referred environmental noise
(4) Reference level sampling error
(5) Reference level generation error
(6) Ensuring that eye-width is measured at the 1/2 eye height point.
(7) Listing of all tap values after adaptation
(4) and (5) are specific imperfections that result from multi-level
signaling. To set a multi-level threshold, a circuit needs to measure
something (4) and a circuit needs to use the measurement to generate
the threshold (5). Both of these will have errors.
(6) is also a multi-level issue. Multi-level eyes are symmetric in
voltage and time but not simultaneously. The widest eye-width is not
at the center of the eye-height. We need to ensure the results are
not the result of taking the best of both.