[BP] Parameter input to signaling spreadsheet



Title: Parameter input to signaling spreadsheet

Additional parameters for signaling spreadsheet

(1) Input referred device noise

(2) Input referred offset

(3) Input referred environmental noise

(4) Reference level sampling error

(5) Reference level generation error

(6) Ensuring that eye-width is measured at the 1/2 eye height point.

(7) Listing of all tap values after adaptation

(4) and (5) are specific imperfections that result from multi-level

signaling.  To set a multi-level threshold, a circuit needs to measure

something (4) and a circuit needs to use the measurement to generate

the threshold (5).  Both of these will have errors.

(6) is also a multi-level issue.  Multi-level eyes are symmetric in

voltage and time but not simultaneously.  The widest eye-width is not

at the center of the eye-height.  We need to ensure the results are

not the result of taking the best of both.

Thanks,

Brian T. Brunn

Xilinx, Communications Technology Division

805 Las Cimas Pkwy #250

Austin, TX  78746

brian.brunn@xilinx.com

512-634-1304