guys, There was some discussion during the teleconference about the relative channel losses of various channels provided by me and simulated by joe and matt. I looked at several of them ad fit them to Amax per 69A and found: channel loss at Nyquist fit at Nyquist AgilentITTC_1016 25.1 25.6dB "Agilent TC Measured" 26.4 26.4dB modITTC23withCoupler.s4p 22.3dB 22.6dB ITTC_23 23.1dB 23.0dB The simulations joe did which i was citing were on "Agilent TC Measured" and ITTC_23, which differ in fit (smoothed) loss at Nyquist by 3.4dB. Note some channels differ from their nominal loss at Nyquist because i picked channels with an Mtc which would give the correct loss but they have Btc values which shifts the whole line a bit. The ISI should still be the same as expected with the nominal loss. charles -- |--------------------------------------------------------------------| | Charles Moore | Avago Technologies | Image Solutions Division | charles.moore@avagotech.com | (970) 288-4561 |--------------------------------------------------------------------| |