Dear Umeda: I just have one comments on Umeda_3ca_1 In page 10, all the power are announced with the linear unit “mW”;
In page 6, the “example” of power are in unit “dBm”. The current threshold calculation formulas must be based on logarithm unit “dBm”, otherwise, the “+” and “-“ operators should be “*” and “/”,
respectively . Such as thx_10G = THx * OLT_Tx / ONU_Tx10G, if all the unit are in “mW”. I think here needs a clear statement on unit to avoid confusing.
Best regards Dekun Liu ____________________________________________________ Advanced Access Technologies Dept.
网络研究接入技术部 Huawei Technologies Co., Ltd.
华为技术有限公司 武汉东湖高新技术开发区九峰三路207号A2栋
邮编:430074 A2 Block, 207 Jiufeng Third Road, East Lake High-Tech Development Zone, Wuhan, China
From: Daisuke Umeda [mailto:umeda@xxxxxxxxx]
Dear Curtis-san, Dear Colleagues,
--
Daisuke Umeda
Sumitomo Electric Industries, Ltd.
1-1-3, Shimaya, Konohana-ku, Osaka 554-0024, Japan