22.2.2.5 TX_ER (transmit coding error) TX_ER shall transition synchronously with respect to the TX_CLK. When TX_ER is asserted for one or more TX_CLK periods while TX_EN is also asserted, the PHY shall emit one or more symbols that are not part of the valid data or delimiter set somewhere in the frame being transmitted. The relative position of the error within the frame need not be preserved. Assertion of the TX_ER signal shall not affect the transmission of data when a PHY is operating at 10Mb/s, or when TX_EN is deasserted.