Re: [802.3_10SPE] Proposed response to MDI connector comment r02-14



Yong, 


To aid in the discussion, please see IEEE Std 802.3-2018, IEEE Standard for Ethernet section one MDI definition (1.4.324 Medium Dependent Interface (MDI)) and compatibility interfaces (1.1.3.2 Compatibility interfaces) defined including MDI ((a) Medium Dependent Interfaces (MDI))

Regards, Chris


1.4.324 Medium Dependent Interface (MDI): The mechanical and electrical or optical interface between
the transmission medium and the MAU (e.g., 10BASE-T) or the PHY (e.g., 1000BASE-T) and also between
the transmission medium and any associated (optional per IEEE Std 802.3, Clause 33) Powered Device (PD)
or Endpoint Power Sourcing Equipment (PSE).

1.1.3.2 Compatibility interfaces
The following important compatibility interfaces are defined within what is architecturally the Physical
Layer.
a) Medium Dependent Interfaces (MDI). To communicate in a compatible manner, all stations shall
adhere rigidly to the exact specification of physical media signals defined in the appropriate clauses
in this standard, and to the procedures that define correct behavior of a station. The medium-independent
aspects of the LLC sublayer and the MAC sublayer should not be taken as detracting from
this point; communication in an Ethernet Local Area Network requires complete compatibility at the
Physical Medium interface (that is, the physical cable interface).


-----Original Message-----
From: Yong Kim <yongkim.mail@xxxxxxxxx>
To: STDS-802-3-10SPE <STDS-802-3-10SPE@xxxxxxxxxxxxxxxxx>
Sent: Thu, Aug 15, 2019 6:08 pm
Subject: Re: [802.3_10SPE] Proposed response to MDI connector comment r02-14

Hi CRG,

Despite my ressoable efforts to stand firm on the use of the traditional and formal definition of MDI that MDI is a mandatory interoperability interface - functional, mechanical, etc., this response uses MDI to mean informative referenced mechanical connector.   So I'll submit a disapprove comment on this aspect of this response, should the sponsor ballot goes through another recalculation.

best regards,

Yong Kim, affiliation: NIO


On Wed, Aug 14, 2019 at 4:12 PM George Zimmerman <george@xxxxxxxxxxxxxxxxxxxx> wrote:
Thank you all for a productive day.  Tomorrow we start at 8am (please begin arriving at 7:15), to formally close this comment as well as the remaining state diagram and new late comments.
Please review this response (approved per motion 5) overnight and email me any necessary corrections.
-george

----
PROPOSED ACCEPT IN PRINCIPLE.
---
add Annex A (Bibliography) into the draft, with the editing instruction:

Insert the following references and associated editor's notes in alphanumeric order as follows:

Editor's Note (to be removed prior to publication):
IEC 63171-1 is in the FDIS stage. The publication date for IEC 63171-1 will need to be inserted prior to publication of IEEE Std 802.3cg.

IEC 63171-1 Ed.1:201x, Connectors for Electrical and Electronic Equipment -
Part 1: Detail specification for 2-way, shielded or unshielded, free and fixed connectors: mechanical mating information, pin assignment and additional requirements for type 1 / Copper LC Style

Editor's Note (to be removed prior to publication):
IEC 63171-6 is in the FDIS stage. The publication date for IEC 63171-6 will need to be inserted prior to publication of IEEE Std 802.3cg.

IEC 63171-6 Ed.1:201x Connectors for Electrical and Electronic Equipment -
Detail specification for 2-way and 4-way (data/power), shielded, free and fixed connectors for power and data transmission with frequencies up to 600 MHz
---

146.8.1 MDI connectors -Page 171, Line 52 add new paragraph;
Connectors meeting the mechanical requirements of IEC 63171-1 or IEC 63171-6 may be used as the mechanical interface to the balanced cabling. The plug connector is used on the balanced cabling and the MDI jack connector on the PHY. The IEC 63171-1 plug and jack are depicted (for informational use only) in Figure 146-29 and Figure 146-30 respectively, and the mating interface is depicted in Figure 146-31. The IEC 63171-6 plug and jack are depicted (for informational use only) in Figure 146-32 and Figure 146-33 respectively, and the mating interface is depicted in Figure 146-34. These connectors should support link segment DCR characteristics for 1.02 mm (18 AWG) to 0.40 mm (26 AWG) in Table 146B-1.

Re-instate IEC 63171-1 plug and jack figures from D3.1 as Figures 146-29, 146-30, and 146-31.
Re-instate IEC 63171-6 plug and jack figures from D3.1 as Figures 146-31, 146-32, and 146-33.


147.9.1 MDI connectors -Page 220, Line 52 add new paragraph;
Connectors meeting the mechanical requirements of IEC 63171-1 or IEC 63171-6 may be used as the mechanical interface to the balanced cabling. The plug connector is used on the balanced cabling and the MDI jack connector on the PHY. The IEC 63171-1 plug and jack are depicted (for informational use only) in Figure 147-21 and Figure 147-22 respectively and the mating interface is depicted in Figure 147-23. The IEC 63171-6 plug and jack are depicted (for informational use only) in Figure 147-24 and Figure 147-25 respectively and the mating interface is depicted in Figure 147-26.  These connectors should support link segment DCR characteristics for 1.02 mm (18 AWG) to 0.40 mm (26 AWG) in Table 146B-1.

Re-instate IEC 63171-1 plug and jack figures from D3.1. as Figures 147-21, 147-22, and 147-23.
Re-instate IEC 63171-6 plug and jack figures from D3.1 as as Figures 147-24, 147-25, and 147-26.

Editorial license to revise figure numbers as needed.

Motion #5:
Move to respond to comment r02-14 with Alternative B: (see straw polls, ACCEPT IN PRINCIPLE - Same text as "A", but with -6 as well.  (Return to the draft 3.0 text, with references corrected))
M:  Chris Diminico
S:  Ron Nordin
(Technical >= 75%)
Y:13  N: 4 A: 7
Motion Passes

George A. Zimmerman, Ph.D.
President & Principal Consultant
CME Consulting, Inc.
Experts in PHYsical Layer Communications
1-310-920-3860
george@xxxxxxxxxxxxxxxxxxxx<mailto:george@xxxxxxxxxxxxxxxxxxxx>


________________________________________________________________________
To unsubscribe from the STDS-802-3-10SPE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-10SPE&A=1

To unsubscribe from the STDS-802-3-10SPE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-10SPE&A=1

To unsubscribe from the STDS-802-3-10SPE list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=STDS-802-3-10SPE&A=1