Re: [802.3_NGBIDI] Draft 0.1 is uploaded



Duane,

I see that in D0.1 you have placeholder PHY names:

10GBASE-BLR-D and 10GBASE-BLR-U
10GBASE-BMR-D and 10GBASE-BMR-U
10GBASE-BER-D and 10GBASE-BER-U

25GBASE-BLR-D and 10GBASE-BLR-U
25GBASE-BMR-D and 10GBASE-BMR-U
25GBASE-BER-D and 10GBASE-BER-U

50GBASE-BLR-D and 10GBASE-BLR-U
50GBASE-BMR-D and 10GBASE-BMR-U
50GBASE-BER-D and 10GBASE-BER-U

However, when I look at the naming for existing bi-directional PHYs in 802.3, I see:
100BASE-BX10-D and 100BASE-BX10-U
1000BASE-BX10-D and 1000BASE-BX10-U

Wouldn't it therefore be more consistent to give the new PHYs the names:

10GBASE-BR10-D and 10GBASE-BR10-U
10GBASE-BR20-D and 10GBASE-BR20-U
10GBASE-BR40-D and 10GBASE-BR40-U

25GBASE-BR10-D and 10GBASE-BR10-U
25GBASE-BR20-D and 10GBASE-BR20-U
25GBASE-BR40-D and 10GBASE-BR40-U

50GBASE-BR10-D and 10GBASE-BR10-U
50GBASE-BR20-D and 10GBASE-BR20-U
50GBASE-BR40-D and 10GBASE-BR40-U

Regards,
Pete Anslow

On Sat, Apr 6, 2019 at 9:00 AM frank effenberger <frank.effenberger@xxxxxxxxxx> wrote:

Duane Remein has prepared the first version of our draft.  

It can be found at: http://www.ieee802.org/3/cp/private/drafts/8023cp_D0p1.pdf

 

Please read it over, and work on contributions to complete and improve it.

 

As a reminder, we are scheduled to have a call on April 18, 13:30 – 15:00 New York time.

This would be a great chance to socialize on these topics.

 

Sincerely,

Frank Effenberger, VP fixed access networks lab, Futurewei Technologies

Chair IEEE P802.3cp Bidirectional 10, 25, and 50 Gb/s Optical Access PHYs Task Force

Rapporteur ITU-T Q2/15 Optical Access Networks Question

For urgent matters, contact sophie.johnson1@xxxxxxxxxx

 