Hi All,

 

In COM 4.4 there are 2 selections to compute the floating taps controlled by the following spreadsheet table entry

 

RXFFE FLOAT CTL

ISI

 

FOM o ISI

 

If there are 1 or 2 groups of tap the FOM method may be as good or better than the ISI method invoked respectively by functions “ findbankloc” and “ FOM_rxffe_floating_taps”.

 

However, 3 or more groups may exhibit a search blocking issue for FOM which ISI method does not have.

 

In many cases I have seen the ISI method yield a slightly better ( a few hundredths of dB)  FOM than the FOM method.

I was thinking of checking both methods unless someone has a better idea for the FOM method that accounts for blocking better.

 

Thoughts,

 

… Rich

 