Thread Links | Date Links | ||||
---|---|---|---|---|---|
Thread Prev | Thread Next | Thread Index | Date Prev | Date Next | Date Index |
Steve, I’m not sure that I understand. The downstream will send a burst when it transmits in the slots used by the upstream. It can’t be continuous. A burst start
and end is determined by the transmitting station (not the receiving station). In this case, the upstream and downstream are bursty. What is the difference to the PHYs? I agree that there is interest in TDD solutions but there are also many TDD solutions in other standards groups. The question is whether adding another project
to support TDD is needed for the EPoC task force. Is it feasible, is it compatible, and does it have a distinct identity. If it is a new PHY and a new MAC, it clearly is another project. If we can start by saying that the PHY is the same, it shows more
hope than earlier ideas of 2 different PHYs. Thanks, Ed… From: Shellhammer, Steve [mailto:sshellha@xxxxxxxxxxxx]
Ed, It is not clear to me that the downstream in TDD is bursty. That does not seem very efficient. I would think it would be a stream of symbols
during the downstream time window. It is a little like the FDD downstream, but maybe a little different. That I why I prefer the term “mode” so that people know it is not a “big” change, but also maybe not identical. I think there is support in the study group for both FDD and TDD, and I think it is important for the study group to make that clear to the working
group in the objectives. Regards, Steve From: Ed (Edward) Boyd
[mailto:ed.boyd@xxxxxxxxxxxx] Hi Jorge, In my mind, we will have a burst PHY defined for the upstream operation of EPoC or EPON. I think that downstream of a half duplex system would be the same
burst PHY. I don’t even see the need for the FDD or TDD description that Steve proposed. In EPON, the data detector in the PHY determines when to enable the laser and send data upstream. The half duplex PHY would enable the same function in the downstream.
I agree that we are defining a PHY for Coax that supports burst mode and continuous mode of operation. I think that could cover our objectives for the PHY. I think that all of the changes needed for half duplex (TDD) are in the MAC and MAC Control. This is traditionally where duplex is handled in 802.3. Hope that helps, Ed…. From: Salinger, Jorge
[mailto:Jorge_Salinger@xxxxxxxxxxxxxxxxx]
Steve, From: Shellhammer, Steve
[mailto:sshellha@xxxxxxxxxxxx]
Chano and Jorge, The terminology we have started to use is a PHY with both FDD and TDD modes. That conveys the idea that FDD and TDD are very similar but they
may have some differences. Maybe that wording would work in the objectives. -------------- Kevin, Nice job in stimulating email traffic.
J Will we be discussing the objectives on Friday? Regards, Steve From: Gomez Chano (LQNA MED)
[mailto:Chano.Gomez@xxxxxxxxxx]
Hi Jorge, thanks for the clarification. I tend to agree that supporting both FDD and TDD would be a good justification for having two PHY - although hopefully both PHYs would have enough commonalities that silicon vendors could easily implement both in the same chip without much
duplication. Chano On May 8, 2012, at 3:17 PM, Salinger, Jorge wrote: As one of the advocates for this objective, I'd like to clarify that the goal we are after is to have TDD system operation for passive coax plant and FDD for
active coax plant. This is what might drive the need for 2 PHYs, and not the spectrum range. From: Marek Hajduczenia
[mailto:marek.hajduczenia@xxxxxxxxx] In that case, “Specify at most two PHYs … “ should be simpler to parse … I guess nobody will specify 0 PHYs … From: Hal
Roberts [mailto:Hal.Roberts@xxxxxxxxx] Marek, I agree there is no worry about more than two PHYs. So here is a modified proposal. Specify at least one PHY and
two PHYs if necessary to support subscriber access networks using the EPON protocol
and operating on point--‐to--‐multipoint RF distribution plants comprised of all--‐coaxial cable or hybrid fiber/coaxial media. If others think the current wording will not be confusing when going to IEEE for SG approval then I am not adamant about it. I know the EPoC group has this
understanding, it is outside readers who may find the current text indicating a preference for more than one PHY. Hal From: Marek
Hajduczenia [mailto:marek.hajduczenia@xxxxxxxxx] Never before was there a problem with such an “understanding”. I would not be averse to the change you propose, but see it as unnecessary nonetheless. We have
spoken until now about two cable plant types (at most) so it would be a clear indication for two PHYs (at most) From: Hal
Roberts [mailto:Hal.Roberts@xxxxxxxxx] If you think “at least one PHY” must remain, then we should have more than an ‘understanding’ that the industry is driving towards a single PHY solution. The
way it reads now, one might think that if we define one PHY we meet our objectives and if we define multiple PHYs we exceed our objectives. The following wording does not preclude two PHYs but doesn’t require the reader to have ‘an understanding’ that the industry is driving to a single PHY solution. Specify at least one PHY and
at most two PHYs if necessary to support subscriber access networks using the
EPON protocol and operating on point--‐to--‐multipoint RF distribution plants comprised of all--‐coaxial cable or hybrid fiber/coaxial media, with a goal to limit From: Marek
Hajduczenia [mailto:marek.hajduczenia@xxxxxxxxx] Neither are my preferred choices of words – I would certainly like to have them nailed down further. However, given the discussion we had at the last meeting, I think leaving the option of doing two PHYs is OK as long as we understand that the industry is driving
towards a single PHY solution. Put it in other words. If we write down “one PHY” and a year from now we figure out we need two, we need at least to modify objectives, which is not as easy as it seems. If we write down “at least one PHY” right now and one year
from now we figure out we can do everything with a single PHY, we are good to go. From the safety perspective, I think it is prudent to leave it as it is and work diligently to make sure no more than one PHY is needed. Marek From: Hal
Roberts [mailto:Hal.Roberts@xxxxxxxxx] Marek, Define “minimal augmentation to MPCP” for me please. There are plenty of undefined terms in the document, I don’t see why the term “flexibility” has a higher burden than other terms. We will define flexibility more precisely when we know what the channel models are. If you are still confused what flexibility means it means variable “QAM
constellation density, FEC, guard interval and frame structure”. We should eliminate the opening for multiple PHYs until someone can show that we can’t do what other standards 802.16e, LTE have done with more difficult channel
model variations. Hal From: Marek
Hajduczenia [mailto:marek.hajduczenia@xxxxxxxxx] Hal, Define “enough flexibility” for me, please. Marek From: Hal
Roberts [mailto:Hal.Roberts@xxxxxxxxx] Charaf, Yes, I have heard the same and would submit the same reasoning I sent out before, “If a single PHY can operate over the wildly varying conditions found in wireless
transmission (i.e. LTE or Wi-Fi with huge swings in signal strength, interference, multipath etc) surely a single PHY should suffice within the more controlled cable environment”. Obviously the PHY parameters would have to be adjustable, i.e. QAM constellation density, FEC, guard interval and others. This is what is done in LTE and Wi-Fi. What shouldn’t need to change is subcarrier spacing, symbol duration and other more difficult to change parameters. As I sent out before, “The burden of proof should be on demonstrating the need for two PHYs.” Having said all of that, it is much more likely that two PHYs might be considered to work well with TDD vs FDD. With FDD the downstream would be a continuous signal (with idle patterns when no data is sent) just like DOCSIS which allows easy synchronization to the downlink
and eliminates the need for preambles at the beginning of a burst (i.e. there are no bursts in the downstream). Whereas with TDD we have to define downstream frames and upstream frames along with guard times. LTE solves this with two types of frame structures, Type 1 for FDD and Type 2 for TDD (see below). As long as we consider two frame structures as defined under one single PHY then we still need only one PHY. “The burden of proof should be on demonstrating the need for two PHYs.” Therefore I would suggest a variation on Gomez’ suggestion: "Specify one PHY to support subscriber access networks using the EPON protocol and operating on point-‐to-‐multipoint
RF distribution plants comprised of all-‐coaxial cable or hybrid fiber/coaxial media, with enough flexibility to operate both below and above 1GHz and in TDD or FDD duplexing modes." Thanks, Hal <image001.png> From: Charaf
HANNA [mailto:charaf.hanna@xxxxxx] Gentlemen, From the 5 Criteria discussion, it seems to me the reference to more than 1 PHY has to do with passive versus active coax plants rather than below versus above
1 GHz. Charaf From: Hal
Roberts [mailto:Hal.Roberts@xxxxxxxxx] Kevin, If a single PHY can operate over the wildly varying conditions found in wireless transmission (i.e. LTE or Wi-Fi with huge swings in signal strength, interference,
multipath etc) surely a single PHY should suffice within the more controlled cable environment. Hal From: Noll,
Kevin [mailto:kevin.noll@xxxxxxxxxxx] There is some concern that operating in the lower bands is significantly different than operating above 1GHz, thus the PHY might need to be different. The reason for
"at least one" is not to have equal and competing specifications, but to allow for two implementations that address multiple sets of coaxial conditions. If the same goal can be attained by a single configurable PHY, then we would probably be okay with that. --kan-- From: "Gomez Chano (LQNA
MED)" <Chano.Gomez@xxxxxxxxxx> Hi, I did not attend the last conference calls, but I have been following progress through the reflector. I have a question about the wording in Objective 1, which is now "Specify at least one PHY to support subscriber access […]" while previous proposal was: "Specify a PHY to support subscriber access networks […] " Can somebody clarify the rationale for the new wording, which seems to "almost" encourage the group to develop more than one PHY? We have all seen other IEEE groups
that quickly yielded to the temptation of adopting multiple PHYs as soon as they realized that having the group agree on a single PHY was hard work. I would hate to see the same thing happening in EPoC, as this would cause market fragmentation and slow down
adoption. The objective should be "one PHY". Only if the group finds at a later stage a very good reason to develop more than one PHY then that option should be considered. Just to be clear, for me it would be OK if the PHY for downstream and upstream channels have different parameters. As long as vendors do not have to face the decision
of choosing between multiple and equally valid PHY options when implementing their products, that would still qualify as "one PHY" for me. Best Regards Chano Gómez Lantiq North America On May 8, 2012, at 9:38 AM, Noll, Kevin wrote: <epoc_objectives_for_may_2012.pdf> <="" p=""> <="" p=""> <="" p=""> <="" p=""> <="" p=""> <="" p="">
|